SourceMed · Shelf #8017 in the ask interface
LANSS / S-LANSS for neuropathic pain: clinician LANSS 80.17% / 100% at ≥12 in a referred Spanish spectrum; S-LANSS AUC 0.9 in acute whiplash (N = 50) — cross-points DN4 #7812, painDETECT #7968, no shared anchors
Shelf #8017 · Brain, stroke & mind
PREDICTIVE PERFORMANCE — form-dependent: clinician LANSS 80.17% / 100% at ≥12 in a referred Spanish spectrum (AUC 0.973); S-LANSS self-report AUC 0.9 (75% / 85%) in acute whiplash at N = 50 and AUC 0.83 in a 188-patient three-questionnaire comparison; the LANSS derivation prints no accuracy pair and the S-LANSS derivation prints correct classification only; cross-point DN4 pack #7812 and painDETECT pack #7968 — no anchor shared with #7812; a screening-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2001–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately do the LANSS Pain Scale (Leeds Assessment of Neuropathic Symptoms and Signs — 5 symptom items plus 2 bedside sensory-examination items, scored 0–24; neuropathic mechanisms likely at ≥12) and its self-complete version the S-LANSS identify pain of predominantly neuropathic origin against expert clinical diagnosis — what did the two derivations establish, how did the LANSS perform in the 192-patient Spanish head-to-head against the DN4, and how did the S-LANSS perform in acute whiplash and in the three-questionnaire comparison?
Balance of the evidence
Ruled distinct from the DN4 shelf (pack #7812) under the painDETECT precedent: no anchor of this shelf is shared with #7812 — the 729-patient polyneuropathy cohort inside #7812, in which the S-LANSS appears as a competitor, is not carded here — and the DN4 figures on the head-to-head cards print as comparators only. Cross-point also to painDETECT pack #7968. The two forms are different measurements and every figure prints with its form: the clinician LANSS includes bedside sensory examination (allodynia, altered pin-prick threshold), the S-LANSS is self-report only. The derivations contribute the instruments, not transportable pairs — the LANSS derivation's abstract reports discriminant ability qualitatively with no sensitivity / specificity pair, and the S-LANSS derivation reports correct classification (75% self-completed, 80% by interview). The strongest pair (LANSS 80.17% / 100% at ≥12) comes from a referred Spanish spectrum against an expert reference standard; the whiplash study's N is 50 and prints on the face. This is a screening-accuracy shelf, not a treatment shelf.
MeSH: Female · Humans · Hyperalgesia/diagnosis · Male · Middle Aged · Neuralgia/diagnosis · Neurons, Afferent · Nociceptors · Pain Measurement/methods,standards · Reproducibility of Results · Chronic Disease · Postal Service · Sensitivity and Specificity · Surveys and Questionnaires/standards · Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Educational Status · Neuralgia/diagnosis,epidemiology · Pain Measurement · Peripheral Nervous System Diseases/complications · Physical Stimulation · ROC Curve · Sample Size · Socioeconomic Factors · Spain/epidemiology · Surveys and Questionnaires · Young Adult · Neuralgia/diagnosis,etiology · Whiplash Injuries/complications,diagnosis · Pain Measurement/methods
Cards (6)
Card 1 — LANSS derivation (Bennett 2001, Pain — two chronic-pain populations, derivation n = 60 and validation n = 40, contrasting neuropathic with nociceptive pain; programme-labelled: the Bennett group's own report): the 7-item scale combines grouped sensory descriptors with bedside sensory-examination items (allodynia, altered pin-prick threshold) — its abstract reports discriminant ability qualitatively and no sensitivity / specificity pair may be printed from it
Study: Derivation and validation — programme-labelled (originators' own report); qualitative accuracy only
Population: Two populations of chronic-pain patients: a derivation group (n = 60) in whom sensory descriptors and questions were compared between nociceptive and neuropathic pain combined with assessment of sensory function, and a validation group (n = 40) assessing discriminant ability, internal consistency and agreement by independent raters. Programme-labelled: the originators' own report.
Summary: LANSS derivation (Bennett 2001, Pain — two chronic-pain populations, derivation n = 60 and validation n = 40, contrasting neuropathic with nociceptive pain; programme-labelled: the Bennett group's own report): the 7-item scale combines grouped sensory descriptors with bedside sensory-examination items (allodynia, altered pin-prick threshold) — its abstract reports discriminant ability qualitatively and no sensitivity / specificity pair may be printed from it
Result: The Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) Pain Scale is based on analysis of sensory description and bedside examination of sensory dysfunction, providing immediate information in clinical settings. The derivation data were used to derive a seven-item pain scale consisting of grouped sensory description and sensory examination with a simple scoring system (0–24; neuropathic mechanisms likely at ≥12). The scale was validated in the second group for discriminant ability, internal consistency and inter-rater agreement, as published. No sensitivity / specificity pair for the finished scale is reported in the fetched abstract, and none is printed on this card.
Watch out: Originators' report, small groups (60 + 40): the widely quoted LANSS accuracy pairs come from later validations carded beside this one, not from this abstract.
Source: Bennett M. The LANSS Pain Scale: the Leeds assessment of neuropathic symptoms and signs. Pain. 2001. PMID: 11323136. Registry ID: none in the record. MeSH: Female · Humans · Hyperalgesia/diagnosis · Male · Middle Aged · Neuralgia/diagnosis · Neurons, Afferent · Nociceptors · Pain Measurement/methods,standards · Reproducibility of Results
Card 2 — S-LANSS derivation (Bennett 2005, Journal of Pain — 200 chronic-pain patients completing the self-report version unaided and by interview against independent clinician pain-type diagnosis, plus a postal survey with 174 returns; programme-labelled: the Bennett group's own report): the scale correctly identified 75% of pain types self-completed and 80% by interview, with self-completed sensitivity 74%–78% depending on cut-off
Study: Derivation / validation of the self-report form — programme-labelled (originators' own report)
Population: 200 patients with chronic pain asked to complete the S-LANSS unaided, then administered the S-LANSS and the Neuropathic Pain Scale in interview format by a researcher, with an independent clinician determining pain type (neuropathic vs nociceptive) and rating diagnostic certainty; the scale was also posted within a chronic-pain questionnaire to 160 community patients and 150 newly referred patients (174 returns, 57%). Programme-labelled: the originators' own report.
Summary: S-LANSS derivation (Bennett 2005, Journal of Pain — 200 chronic-pain patients completing the self-report version unaided and by interview against independent clinician pain-type diagnosis, plus a postal survey with 174 returns; programme-labelled: the Bennett group's own report): the scale correctly identified 75% of pain types self-completed and 80% by interview, with self-completed sensitivity 74%–78% depending on cut-off
Result: The S-LANSS scale correctly identified 75% of pain types when self-completed and 80% when used in interview format. Sensitivity for self-completed S-LANSS scores ranged from 74% to 78% depending on the cut-off score. There were significant associations between Neuropathic Pain Scale items and total score and the S-LANSS score, and internal consistency and convergent validity of the postal-survey scores were confirmed. The authors concluded the S-LANSS is a valid and reliable self-report instrument for identifying neuropathic pain, also acceptable for postal survey research, as published.
Watch out: The S-LANSS is self-report only — a different measurement from the clinician LANSS, which includes bedside sensory examination. Correct-classification percentages (75% / 80%) are not sensitivity / specificity pairs and print as what they are.
Source: Bennett et al. The S-LANSS score for identifying pain of predominantly neuropathic origin: validation for use in clinical and postal research. The journal of pain. 2005. PMID: 15772908. Registry ID: none in the record. MeSH: Chronic Disease · Female · Humans · Male · Middle Aged · Neuralgia/diagnosis · Pain Measurement/methods,standards · Postal Service · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires/standards
Card 3 — Spanish head-to-head (Hamdan 2014, European Journal of Pain — 192 patients against clinical diagnosis of peripheral neuropathic pain): at ≥12 the LANSS had sensitivity 80.17% and specificity 100% (AUC 0.973 (95% CI 0.956 to 0.991)), against the DN4's 95.04% / 97.18% (AUC 0.989) as comparator — carded for its LANSS limb; the DN4's own shelf is pack #7812 and no anchor is shared with it
Study: Head-to-head validation — LANSS limb (DN4 figures as comparator)
Population: 192 patients enrolled in Spain for comparison of the LANSS pain scale and the DN4 questionnaire against clinical diagnosis of peripheral neuropathic pain, with item-level diagnostic quality analysed for both questionnaires.
Summary: Spanish head-to-head (Hamdan 2014, European Journal of Pain — 192 patients against clinical diagnosis of peripheral neuropathic pain): at ≥12 the LANSS had sensitivity 80.17% and specificity 100% (AUC 0.973 (95% CI 0.956 to 0.991)), against the DN4's 95.04% / 97.18% (AUC 0.989) as comparator — carded for its LANSS limb; the DN4's own shelf is pack #7812 and no anchor is shared with it
Result: At its accepted cut-off of ≥12 the LANSS had sensitivity 80.17% and specificity 100%, with an area under the ROC curve of 0.973 (95% CI 0.956 to 0.991). The DN4 comparator at ≥4 had sensitivity 95.04% and specificity 97.18% (AUC 0.989), a significantly larger AUC (p < 0.05). For the LANSS, light-touch pain and altered pinprick threshold were the most important neuropathic features. The authors concluded both questionnaires are good screening tools, with the DN4 particularly recommended, as published.
Watch out: The 100% specificity comes from a referred spectrum with an expert reference standard and prints with that spectrum; it is not a general-population figure. Carded for the LANSS limb only — cross-point DN4 pack #7812.
Source: Hamdan et al. Diagnostic accuracy of two questionnaires for the detection of neuropathic pain in the Spanish population. European journal of pain (London, England). 2014. PMID: 23776139. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cross-Sectional Studies · Educational Status · Female · Humans · Male · Middle Aged · Neuralgia/diagnosis,epidemiology · Pain Measurement · Peripheral Nervous System Diseases/complications · Physical Stimulation · ROC Curve · Reproducibility of Results · Sample Size · Socioeconomic Factors · Spain/epidemiology · Surveys and Questionnaires · Young Adult
Card 4 — Acute whiplash (Ríos-León 2024, Pain Medicine — 50 patients with acute whiplash-associated disorders against specialist-physician assessment; small N prints on the face): the S-LANSS had the highest AUC of the three tools (0.9), with sensitivity 75% and specificity 85%; DN4 sensitivity was 87% and painDETECT specificity 82% as comparators — carded for its S-LANSS limb; cross-points DN4 pack #7812 and painDETECT pack #7968
Study: Cross-sectional accuracy study in acute whiplash — S-LANSS limb (DN4 / painDETECT figures as comparators); N = 50
Population: 50 people (68% women, mean age 40.3 (SD 12.5) years; 52% grade III) with acute whiplash-associated disorders, of 188 eligible individuals, screened by specialised physicians for neuropathic-pain components as the reference standard, then assessed blinded with the DN4, S-LANSS and painDETECT within 2 weeks of their accident.
Summary: Acute whiplash (Ríos-León 2024, Pain Medicine — 50 patients with acute whiplash-associated disorders against specialist-physician assessment; small N prints on the face): the S-LANSS had the highest AUC of the three tools (0.9), with sensitivity 75% and specificity 85%; DN4 sensitivity was 87% and painDETECT specificity 82% as comparators — carded for its S-LANSS limb; cross-points DN4 pack #7812 and painDETECT pack #7968
Result: The three screening questionnaires showed excellent discriminant validity (AUC ≥0.8), especially the S-LANSS (AUC 0.9, p < .001). The DN4 demonstrated the highest sensitivity (87%), followed by the S-LANSS (75%), while the S-LANSS and painDETECT showed the highest specificity (85% and 82% respectively). All three correlated strongly with the reference standard (S-LANSS rho = 0.7). The authors concluded the tools — especially the S-LANSS — show excellent discriminant validity for neuropathic components in acute whiplash, as published.
Watch out: N = 50 in an acute, single-condition spectrum (whiplash within 2 weeks): these pairs describe acute whiplash only and print with that population. Carded for the S-LANSS limb only.
Source: Ríos-León et al. Usefulness of the DN4, S-LANSS, and painDETECT screening questionnaires to detect the neuropathic pain components in people with acute whiplash-associated disorders: a cross-sectional study. Pain medicine (Malden, Mass.). 2024. PMID: 38150190. Registry ID: none in the record. MeSH: Humans · Cross-Sectional Studies · Female · Male · Neuralgia/diagnosis,etiology · Whiplash Injuries/complications,diagnosis · Adult · Surveys and Questionnaires · Middle Aged · Pain Measurement/methods · Sensitivity and Specificity
Card 5 — Three-questionnaire comparison (Abolkhair 2021, Saudi Journal of Anaesthesia — prospective comparison in 188 patients, 141 with definite neuropathic and 47 with non-neuropathic pain against clinical diagnosis): S-LANSS AUC was 0.83 (95% CI 0.75 to 0.90) with Cronbach's α 0.65, and at optimal cut-offs the S-LANSS had the lowest sensitivity and highest specificity of the three tools (DN4 AUC 0.89, NPQ-SF AUC 0.82 as comparators) — carded for its S-LANSS limb; this record carries no MeSH in PubMed
Study: Prospective three-questionnaire comparison — S-LANSS limb (DN4 / NPQ-SF figures as comparators)
Population: 188 patients analysed prospectively: 141 (75%) with 'definite neuropathic' pain and 47 (25%) with 'nonneuropathic' pain, assessed with the S-LANSS, DN4 and Neuropathic Pain Questionnaire-Short Form (NPQ-SF) against the reference clinical diagnosis, with reliability (Cronbach's α, inter-item correlations), ROC and agreement (Cohen's κ) analyses.
Summary: Three-questionnaire comparison (Abolkhair 2021, Saudi Journal of Anaesthesia — prospective comparison in 188 patients, 141 with definite neuropathic and 47 with non-neuropathic pain against clinical diagnosis): S-LANSS AUC was 0.83 (95% CI 0.75 to 0.90) with Cronbach's α 0.65, and at optimal cut-offs the S-LANSS had the lowest sensitivity and highest specificity of the three tools (DN4 AUC 0.89, NPQ-SF AUC 0.82 as comparators) — carded for its S-LANSS limb; this record carries no MeSH in PubMed
Result: The S-LANSS demonstrated acceptable reliability (Cronbach's α 0.65 (95% CI 0.57 to 0.72)) and an area under the ROC curve of 0.83 (0.75 to 0.90); comparators were DN4 α 0.74 with AUC 0.89 (0.83 to 0.95) and NPQ-SF α 0.54 with AUC 0.82 (0.75 to 0.89) — all three described by the authors as showing excellent diagnostic ability. Based on their optimal cut-off values, the DN4 had the highest sensitivity and lowest specificity of the three, while the S-LANSS had the lowest sensitivity and highest specificity; the fetched abstract reports this ordering qualitatively and gives no numerical sensitivity / specificity pair for the S-LANSS, and none is printed on this card, as published.
Watch out: An enriched spectrum (75% definite neuropathic) and a qualitative sensitivity / specificity ordering: no pair may be attached to the S-LANSS from this report. Source line states 'MeSH: none in the record' — this PubMed record carries no MeSH terms.
Source: Abolkhair et al. Psychometric and accuracy comparison of three commonly used questionnaires for the diagnosis of neuropathic pain. Saudi journal of anaesthesia. 2021. PMID: 34658728. Registry ID: none in the record. MeSH: none in the record
Card 6 — Synthesis: the LANSS family discriminates well in referred spectra and modestly elsewhere — clinician LANSS 80.17% / 100% at ≥12 in Spain (AUC 0.973), S-LANSS AUC 0.9 in acute whiplash (N = 50) and 0.83 in a 188-patient comparison, with the derivations contributing the instruments rather than transportable pairs; every figure belongs to its form (clinician examination vs self-report)
Study: Synthesis
Population: All reports carded on this shelf: Bennett 2001 LANSS derivation (n = 60 + 40), Bennett 2005 S-LANSS derivation (200 patients + 174 postal returns), Hamdan 2014 (192 patients), Ríos-León 2024 (50 patients) and Abolkhair 2021 (188 patients). No anchor is shared with pack #7812 (DN4) or pack #7968 (painDETECT).
Summary: Synthesis: the LANSS family discriminates well in referred spectra and modestly elsewhere — clinician LANSS 80.17% / 100% at ≥12 in Spain (AUC 0.973), S-LANSS AUC 0.9 in acute whiplash (N = 50) and 0.83 in a 188-patient comparison, with the derivations contributing the instruments rather than transportable pairs; every figure belongs to its form (clinician examination vs self-report)
Result: Clinician LANSS: 80.17% / 100% at ≥12, AUC 0.973, in a referred Spanish spectrum (DN4 comparator 95.04% / 97.18%). S-LANSS: 75% correct classification self-completed at derivation (sensitivity 74%–78% by cut-off); AUC 0.9 with 75% / 85% in acute whiplash (N = 50); AUC 0.83 with the lowest sensitivity and highest specificity of three tools in the 188-patient comparison. Cross-points: DN4 pack #7812 and painDETECT pack #7968 — different instruments; the gated 729-patient polyneuropathy cohort inside #7812 is not carded here. This is a screening-accuracy shelf only; no card implies LANSS-guided treatment improves outcomes.
Watch out: Reference standards differ across reports (clinician pain-type diagnosis, specialist assessment, definite-neuropathic grading) and print with their figures.
Source: Synthesis of the reports carded above; no additional source.