Qmci across languages: AUC 0.97 in the programme's own clinic vs 0.82 in US memory clinics — five validations, cut-offs from ≤57 to <67, no derivation carded

Shelf #8039 · Brain, stroke & mind

PREDICTIVE PERFORMANCE: Qmci AUC for cognitive impairment 0.97 in the programme's own Australian geriatric clinic (91% / 93% at ≤57) and 0.82 in US memory clinics (79% / 80% at <67); Dutch AUCs 0.86 / 0.73 / 0.95 by contrast; German AUC 0.96 in n = 80 defined groups; Chinese post-stroke AUCs 0.94 / 0.91 in n = 34; composition 5 validations, no derivation carded, two programme-linked; cut-offs migrate by target and language; a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2015–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does the Qmci (Quick Mild Cognitive Impairment screen — six subtests including clock drawing and verbal fluency, scored to 100, designed to separate MCI from normal cognition and mild dementia in under five minutes) perform across languages and settings — what accuracy did the Dutch, Australian, American, German and Chinese post-stroke validations find against the MMSE / MoCA and clinical classification?

Balance of the evidence

Composition prints: 5 validations, no derivation carded — the original Irish derivation report was not returned by the mining desk's searches, so this shelf stands on five independent validations, two of them programme-linked (the Australian report is the O'Caoimh group's own and is programme-labelled on its card; the Dutch adaptation is by the programme's collaborators). A screening-accuracy shelf, not a treatment shelf. Spectrum is the headline: the programme clinic's AUC for cognitive impairment (0.97, at ≤57 sensitivity 91% / specificity 93%) and the US memory clinics' (0.82, at <67 79% / 80%) answer the same question in different spectra and are never merged. Cut-offs migrate (≤57 vs <67 vs ≤67) by target and language and print with their populations. The two small validations print with their Ns (German n = 80, defined groups; Chinese post-stroke n = 34). Cross-points in prose only: SLUMS (#8037), 6CIT (#8038), ACE-III (#8040), the Memory Impairment Screen family (#8041), and MoCA / MMSE at pack #7807.

MeSH: Aged · Aged, 80 and over · Cognitive Dysfunction/diagnosis,psychology · Dementia/diagnosis,epidemiology,psychology · Ethnicity · Female · Humans · Male · Middle Aged · Netherlands · Neuropsychological Tests/standards · Area Under Curve · Brief Psychiatric Rating Scale/standards · Geriatric Assessment/methods · Mental Status and Dementia Tests/standards · ROC Curve · Sensitivity and Specificity · Cognitive Dysfunction/diagnosis · Dementia/diagnosis · United States · Reproducibility of Results · Mass Screening/methods · Early Diagnosis · Retrospective Studies · Germany

Cards (6)

Card 1 — Dutch validation (Bunt 2015, BMC Geriatrics — Qmci-D, 90 geriatric-clinic participants: 25 dementia / 30 MCI / 35 normal, against the standardised MMSE): AUCs were 0.86 for MCI vs normal, 0.73 for MCI vs dementia and 0.95 for dementia vs normal, the last two significantly above the standardised MMSE's

Study: Validation study (primary report)

Population: 90 participants recruited from a hospital geriatric clinic in the Netherlands (25 with dementia, 30 with MCI, 35 with normal cognition); the Dutch Qmci (Qmci-D) and the Dutch standardised MMSE (SMMSE-D) were administered sequentially but randomly by the same trained rater, blind to the diagnosis.

Summary: Dutch validation (Bunt 2015, BMC Geriatrics — Qmci-D, 90 geriatric-clinic participants: 25 dementia / 30 MCI / 35 normal, against the standardised MMSE): AUCs were 0.86 for MCI vs normal, 0.73 for MCI vs dementia and 0.95 for dementia vs normal, the last two significantly above the standardised MMSE's

Result: The Qmci-D was more sensitive than the SMMSE-D in discriminating MCI from dementia, AUC 0.73 compared with 0.60 (p = 0.024), and in discriminating dementia from normal cognition, AUC 0.95 compared with 0.89 (p = 0.006). Both instruments discriminated MCI from normal cognition with an AUC of 0.86 (Qmci-D) and 0.84 (SMMSE-D), as published.

Watch out: A defined-group clinic sample (25 / 30 / 35), not consecutive referrals — AUCs from such spectra read higher than in unselected clinics. The Dutch adaptation is by the Qmci programme's collaborators and prints as a programme-linked validation. The reference comparator is the standardised MMSE, a weaker standard than clinical classification.

Source: Bunt et al. Validation of the Dutch version of the quick mild cognitive impairment screen (Qmci-D). BMC geriatrics. 2015. PMID: 26431959. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cognitive Dysfunction/diagnosis,psychology · Dementia/diagnosis,epidemiology,psychology · Ethnicity · Female · Humans · Male · Middle Aged · Netherlands · Neuropsychological Tests/standards

Card 2 — Australian validation (Clarnette 2017, International Journal of Geriatric Psychiatry — geriatric-clinic comparison, 72 MCI / 109 dementia / 41 normal against comprehensive assessment): for cognitive impairment (MCI or dementia) the Qmci AUC was 0.97 vs the MoCA's 0.92, and at ≤57 sensitivity was 91% and specificity 93% — programme-labelled: the O'Caoimh group's own report

Study: Validation study — programme-labelled (the Qmci developers' own group)

Population: Consecutive referrals presenting with cognitive complaints to a teaching hospital geriatric clinic (Fremantle, Western Australia), classified after comprehensive assessment as MCI (n = 72) or dementia (n = 109); normal controls (n = 41) were a sample of convenience. The Qmci and MoCA were scored by trained geriatricians, in random order, blind to the diagnosis.

Summary: Australian validation (Clarnette 2017, International Journal of Geriatric Psychiatry — geriatric-clinic comparison, 72 MCI / 109 dementia / 41 normal against comprehensive assessment): for cognitive impairment (MCI or dementia) the Qmci AUC was 0.97 vs the MoCA's 0.92, and at ≤57 sensitivity was 91% and specificity 93% — programme-labelled: the O'Caoimh group's own report

Result: Median Qmci scores were 69 for normal controls, 52.5 for MCI and 36 for dementia. The Qmci more accurately identified cognitive impairment (MCI or dementia), AUC 0.97, than the MoCA (AUC 0.92, p = 0.04); at the optimal cut-off of ≤57 the Qmci had sensitivity 91% and specificity 93% for cognitive impairment, compared with 87% sensitivity and 80% specificity for the MoCA (≤23). For MCI vs controls the Qmci AUC was 0.91 vs the MoCA's 0.84 (not significant); for MCI vs dementia, 0.91 vs 0.88, as published.

Watch out: Programme-labelled: this is the Qmci group's own report, and its AUC of 0.97 is the highest on this shelf — memory-clinic spectra with convenience controls read higher than consecutive-clinic spectra (compare the US validation's 0.82). The ≤57 cut-off is this population's, not a universal Qmci threshold.

Source: Clarnette et al. Comparison of the Quick Mild Cognitive Impairment (Qmci) screen to the Montreal Cognitive Assessment (MoCA) in an Australian geriatrics clinic. International journal of geriatric psychiatry. 2017. PMID: 27427212. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Area Under Curve · Brief Psychiatric Rating Scale/standards · Cognitive Dysfunction/diagnosis,psychology · Female · Geriatric Assessment/methods · Humans · Male · Mental Status and Dementia Tests/standards · Neuropsychological Tests/standards · ROC Curve · Sensitivity and Specificity

Card 3 — US validation (Fernandez 2024, International Journal of Geriatric Psychiatry — 152 memory-clinic participants: 87 normal / 48 MCI / 17 mild dementia): AUC 0.82 vs the MMSE's 0.77 for normal vs impaired, and at <67 sensitivity was 79% and specificity 80%

Study: Validation study (primary report)

Population: 152 older adults from two memory specialty (secondary outpatient) clinics in the United States: 87 cognitively normal, 48 with mild cognitive impairment and 17 with mild dementia; classification accuracy of the Qmci and the Mini-Mental State Examination (MMSE) was compared in participants with and without cognitive impairment.

Summary: US validation (Fernandez 2024, International Journal of Geriatric Psychiatry — 152 memory-clinic participants: 87 normal / 48 MCI / 17 mild dementia): AUC 0.82 vs the MMSE's 0.77 for normal vs impaired, and at <67 sensitivity was 79% and specificity 80%

Result: The Qmci demonstrated higher classification accuracy in differentiating cognitively normal from cognitively impaired participants (MCI and mild dementia) (AUC = 0.82) than the MMSE (AUC = 0.77). The optimal Qmci cut-off was <67, achieving sensitivity 79% and specificity 80%; the optimal MMSE cut-off was <27, achieving sensitivity 97% and specificity 43%, as published.

Watch out: The mild-dementia group is only 17 participants, so this validation effectively answers MCI-vs-normal separation. Its AUC (0.82) and the Australian clinic's (0.97) answer the same question in different spectra and may not be merged; the <67 cut-off here vs ≤57 in Australia shows how far cut-offs migrate by target and population.

Source: Fernandez et al. Validation of the Quick Mild Cognitive Impairment Screen in an American Sample of Patients With Mild Cognitive Impairment and Mild Dementia. International journal of geriatric psychiatry. 2024. PMID: 39586819. Registry ID: none in the record. MeSH: Humans · Female · Cognitive Dysfunction/diagnosis · Male · Aged · Dementia/diagnosis · United States · Aged, 80 and over · Mental Status and Dementia Tests/standards · Neuropsychological Tests/standards · Sensitivity and Specificity · Reproducibility of Results · Mass Screening/methods · Middle Aged · Early Diagnosis

Card 4 — German validation (Manser 2024, BMC Geriatrics — retrospective analysis of 43 healthy older adults and 37 with biomarker-characterised mild neurocognitive disorder): at ≤67 AUC was 0.96, sensitivity 91.9% and specificity 90.7%, α 0.71 — small N prints on the face

Study: Validation study (primary report) — small N (n = 80)

Population: Retrospective analysis of data from healthy older adults (n = 43) and individuals with a clinical diagnosis of mild neurocognitive disorder (n = 37) with biomarker-supported characterisation of aetiology, from three studies of the 'Brain-IT' project in Germany; the German Qmci (Qmci-G) was assessed for diagnostic accuracy, internal consistency and construct validity.

Summary: German validation (Manser 2024, BMC Geriatrics — retrospective analysis of 43 healthy older adults and 37 with biomarker-characterised mild neurocognitive disorder): at ≤67 AUC was 0.96, sensitivity 91.9% and specificity 90.7%, α 0.71 — small N prints on the face

Result: The optimal cut-off for the Qmci-G was ≤67 (AUC = 0.96), providing sensitivity 91.9% and specificity 90.7%, with positive predictive value 89.5% and negative predictive value 92.9%. Cronbach's α was 0.71. The Qmci-G showed good construct validity for subtests measuring learning and memory; subtests measuring executive functioning and/or visuospatial skills showed mixed findings, as published.

Watch out: Small N prints: 80 participants in two defined groups (43 healthy / 37 disorder) — a case-control-style spectrum that inflates accuracy against consecutive-clinic samples, and a retrospective analysis, not a prospective clinic validation.

Source: Manser et al. Diagnostic accuracy, reliability, and construct validity of the German quick mild cognitive impairment screen. BMC geriatrics. 2024. PMID: 39026157. Registry ID: none in the record. MeSH: Humans · Cognitive Dysfunction/diagnosis,psychology · Aged · Male · Female · Retrospective Studies · Reproducibility of Results · Germany · Aged, 80 and over · Sensitivity and Specificity · Neuropsychological Tests/standards · Middle Aged · Mass Screening/methods

Card 5 — Chinese post-stroke validation (Xu 2021, Frontiers in Neurology — 34 rehabilitation patients: 11 post-stroke dementia / 15 post-stroke cognitive impairment without dementia / 8 normal): Qmci-CN AUCs were 0.94 for dementia vs normal and 0.91 for dementia vs impairment-no-dementia, comparable to the MoCA-CN at roughly half the administration time (329 vs 611 seconds), but relatively poor at separating impairment-no-dementia from normal — small N prints on the face; this record carries no MeSH in its PubMed record

Study: Validation study (primary report) — small N (n = 34), post-stroke population

Population: 34 patients who had recovered from a stroke, recruited in rehabilitation unit clinics in two university hospitals in China: 11 with post-stroke dementia (PSD), 15 with post-stroke cognitive impairment no dementia (PSCIND) and 8 with normal cognition; classification by clinician assessment supported by a neuropsychological battery, independent of the screening scores; the Qmci-CN, MoCA-CN and MMSE-CN were administered randomly by a trained rater blind to the diagnosis. Mean age 63 ± 13 years, 61.8% male.

Summary: Chinese post-stroke validation (Xu 2021, Frontiers in Neurology — 34 rehabilitation patients: 11 post-stroke dementia / 15 post-stroke cognitive impairment without dementia / 8 normal): Qmci-CN AUCs were 0.94 for dementia vs normal and 0.91 for dementia vs impairment-no-dementia, comparable to the MoCA-CN at roughly half the administration time (329 vs 611 seconds), but relatively poor at separating impairment-no-dementia from normal — small N prints on the face; this record carries no MeSH in its PubMed record

Result: The Qmci-CN had statistically similar diagnostic accuracy to the MoCA-CN and MMSE-CN in differentiating PSD from normal cognition (AUC 0.94 vs 0.99 and 0.99) and in separating PSD from PSCIND (AUC 0.91 vs 0.94 and 0.79). The MoCA-CN more accurately distinguished PSCIND from normal cognition than the Qmci-CN (p = 0.015). Administration times were 329 seconds for the Qmci-CN vs 611 seconds for the MoCA-CN, as published; the authors state the study is under-powered given the small sample size.

Watch out: Small N prints: 34 patients, only 8 of them cognitively normal — every AUC here rests on single-digit denominators in one arm. This is a post-stroke population study, not dementia case-finding in a memory clinic, and its pairs may not be merged with the clinic validations.

Source: Xu et al. Screening for Cognitive Impairment After Stroke: Validation of the Chinese Version of the Quick Mild Cognitive Impairment Screen. Frontiers in neurology. 2021. PMID: 33763012. Registry ID: none in the record. MeSH: none in the record

Card 6 — Synthesis: five validations, no derivation carded — the Qmci separates impairment from normal cognition with AUCs from 0.82 (US memory clinics) to 0.97 (the programme's own Australian clinic), cut-offs migrating from ≤57 to <67 / ≤67 by target and language, and the two smallest validations (n = 80 and n = 34) resting on defined-group and post-stroke spectra

Study: Synthesis

Population: All reports carded on this shelf: 5 validations — Dutch (Bunt 2015; n = 90), Australian (Clarnette 2017; n = 222, programme-labelled), US (Fernandez 2024; n = 152), German (Manser 2024; n = 80) and Chinese post-stroke (Xu 2021; n = 34). The original Irish derivation report was not returned by the mining desk's searches and is not carded — this shelf stands on the five validations, two of them programme-linked (the Australian report is the developers' own; the Dutch adaptation is by programme collaborators).

Summary: Synthesis: five validations, no derivation carded — the Qmci separates impairment from normal cognition with AUCs from 0.82 (US memory clinics) to 0.97 (the programme's own Australian clinic), cut-offs migrating from ≤57 to <67 / ≤67 by target and language, and the two smallest validations (n = 80 and n = 34) resting on defined-group and post-stroke spectra

Result: For cognitive impairment vs normal cognition: AUC 0.97 and 91% / 93% at ≤57 in the Australian geriatric clinic (programme-labelled); AUC 0.82 and 79% / 80% at <67 in US memory clinics. For MCI-separation targets: Dutch AUCs 0.86 (MCI vs normal), 0.73 (MCI vs dementia), 0.95 (dementia vs normal) against the standardised MMSE; German AUC 0.96 at ≤67 in 80 defined-group participants; Chinese post-stroke AUCs 0.94 / 0.91 for dementia contrasts in 34 patients, with poor PSCIND-vs-normal separation. Spectrum prints with every figure; cut-offs migrate by target and language and are never merged. This is a screening-accuracy shelf only.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.