SourceMed · Shelf #8041 in the ask interface

Memory Impairment Screen family: the picture form falls from 95.4% / 99.2% in its Kerala derivation to 68% / 81% in a US memory centre — three forms, four reports, no merged pair

Shelf #8041 · Brain, stroke & mind

PREDICTIVE PERFORMANCE — form-specific: the original MIS derivation reports discriminative validity with no pair printed in its abstract (programme-labelled); by telephone (MIS-T), specificity 93% vs 78% / 80% for fluency / TICS at sensitivity fixed at 78%; the picture form (PMIS) scored 95.4% / 99.2% at cut-score 5 in its Kerala derivation sample (n = 304) but 68% / 81% in a US memory centre (n = 405 consecutive complainers); composition 4 reports across 3 forms of one family, derivation reports programme-labelled; a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 1999–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does the Memory Impairment Screen family (MIS — a four-item delayed free- and cued-recall test using controlled learning; its telephone form MIS-T; and its picture-based form PMIS, designed for low-literacy and ethnically diverse populations) detect dementia — what did the original criterion validation establish, how did the telephone form compare with telephone fluency and the TICS, and what accuracy did the picture-based form achieve in India and in a US memory-disorders centre?

Balance of the evidence

Composition prints: 4 reports across 3 forms of one instrument family — the original MIS criterion validation, the MIS-T telephone validation, and two PMIS (picture-based) validations — never four measurements of the same test; every figure prints with its form. A screening-accuracy shelf, not a treatment shelf. The derivation reports are programme-labelled (the Buschke / Einstein group), and the original MIS report's abstract prints no sensitivity / specificity pair, so none is printed from it. The PMIS pair collapses between its derivation spectrum (95.4% / 99.2% in a Kerala community sample with defined dementia cases) and the US clinic spectrum (68% / 81% in 405 consecutive complainers) — both print, and the gap is the headline. The MIS-T comparison fixes sensitivity at 78% by construction and prints as a specificity comparison at that fixed point (93% vs 78% / 80%), not as three independent pairs. Cross-points in prose only: SLUMS (#8037), 6CIT (#8038), Qmci (#8039), ACE-III (#8040), and MoCA / MMSE at pack #7807.

MeSH: Aged · Aged, 80 and over · Alzheimer Disease/diagnosis · Dementia/diagnosis · Diagnosis, Differential · Female · Humans · Male · Mass Screening/methods · Memory Disorders/diagnosis · Mental Recall · Neuropsychological Tests · Probability · ROC Curve · Reproducibility of Results · Sensitivity and Specificity · Cross-Sectional Studies · Longitudinal Studies · Predictive Value of Tests · Telephone · Dementia/complications,diagnosis · Diagnostic Techniques, Neurological · Memory Disorders/etiology · Photography · Prospective Studies · Cognitive Dysfunction/diagnosis · Cohort Studies · Mental Status and Dementia Tests/standards · Psychometrics

Cards (5)

Card 1 — Original criterion validation (Buschke 1999, Neurology — MIS derivation / criterion validation; 483 aged individuals, 50 with DSM-III-R dementia): the MIS had good alternate-forms reliability and discriminative validity, with normative data presented for settings of differing dementia prevalence — programme-labelled: the Buschke / Einstein group's own report; its abstract reports discriminative validity without printing a sensitivity / specificity pair, and none is printed from it

Study: Derivation / criterion validation — programme-labelled (the developers' own group)

Population: A criterion sample of 483 aged individuals, 50 of whom had dementia according to Diagnostic and Statistical Manual of Mental Disorders (3rd ed., revised) criteria; equivalent forms of the Memory Impairment Screen (MIS) — a 4-minute, four-item, delayed free- and cued-recall test using controlled learning — were given at the beginning and end of the testing session to assess alternate-forms reliability.

Summary: Original criterion validation (Buschke 1999, Neurology — MIS derivation / criterion validation; 483 aged individuals, 50 with DSM-III-R dementia): the MIS had good alternate-forms reliability and discriminative validity, with normative data presented for settings of differing dementia prevalence — programme-labelled: the Buschke / Einstein group's own report; its abstract reports discriminative validity without printing a sensitivity / specificity pair, and none is printed from it

Result: The MIS had good alternate forms reliability, high construct validity for memory impairment, and good discriminative validity in terms of sensitivity, specificity, and positive predictive value. Normative data are presented for use in settings with different base rates (prevalences) of Alzheimer's disease and dementia, as published — the abstract reports no numerical sensitivity / specificity pair, and none is printed on this card.

Watch out: Programme-labelled derivation: the founding report's near-qualitative wording ('good discriminative validity') prints as published, with no pair invented for it. Every accuracy pair on this shelf comes from the later forms and populations, and each prints with its form.

Source: Buschke et al. Screening for dementia with the memory impairment screen. Neurology. 1999. PMID: 9932936. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Alzheimer Disease/diagnosis · Dementia/diagnosis · Diagnosis, Differential · Female · Humans · Male · Mass Screening/methods · Memory Disorders/diagnosis · Mental Recall · Neuropsychological Tests · Probability · ROC Curve · Reproducibility of Results · Sensitivity and Specificity

Card 2 — Telephone validation (Lipton 2003, Journal of the American Geriatrics Society — MIS-T nested in the Einstein Aging Study, 300 community volunteers, 27 with dementia on in-person evaluation): at cut-scores fixing sensitivity at 78% for all three telephone tests, the MIS-T's specificity (93%) significantly exceeded category fluency (78%) and the TICS (80%); administration 4 minutes — programme-labelled

Study: Validation study (telephone form) — programme-labelled

Population: Three hundred elderly community volunteers living in Bronx County, New York, nested within the longitudinal Einstein Aging Study; 27 were diagnosed with dementia (18 with Alzheimer's disease) based on in-person clinical evaluation. A telephone battery — the Memory Impairment Screen by telephone (MIS-T), the Category Fluency Test (CF-T) and the Telephone Instrument for Cognitive Status (TICS) — was administered before the in-person evaluation.

Summary: Telephone validation (Lipton 2003, Journal of the American Geriatrics Society — MIS-T nested in the Einstein Aging Study, 300 community volunteers, 27 with dementia on in-person evaluation): at cut-scores fixing sensitivity at 78% for all three telephone tests, the MIS-T's specificity (93%) significantly exceeded category fluency (78%) and the TICS (80%); administration 4 minutes — programme-labelled

Result: The MIS-T required 4 minutes, the CF-T 3 minutes and the TICS 10 minutes. Using cutscores on all three tests that provide a sensitivity of 78%, specificity was significantly higher for the MIS-T (93%) than for the CF-T (78%, P < .05) or the TICS (80%, P < .05). Combining the MIS-T and CF-T improved discriminative validity but increased screening time and scoring complexity. Normative data for settings with different dementia prevalences are presented, as published.

Watch out: Programme-labelled (the Einstein group validating its own instrument by telephone). The comparison fixes sensitivity at 78% by construction — this is a specificity comparison at that fixed point, not three independent accuracy pairs, and prints as such. Only 27 of 300 volunteers had dementia.

Source: Lipton et al. Screening for dementia by telephone using the memory impairment screen. Journal of the American Geriatrics Society. 2003. PMID: 14511157. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Alzheimer Disease/diagnosis · Cross-Sectional Studies · Female · Humans · Longitudinal Studies · Male · Mass Screening/methods · Neuropsychological Tests · Predictive Value of Tests · ROC Curve · Sensitivity and Specificity · Telephone

Card 3 — Picture-based form in India (Verghese 2012, Journal of the American Geriatrics Society — PMIS derivation / validation, 304 community-residing adults aged 55–94 in Kerala, India, 65 with dementia): at a cut-score of 5 sensitivity was 95.4% (95% CI 90.3 to 100.0) and specificity 99.2% (98.0 to 100.0), with better specificity than the MMSE especially at low education

Study: Derivation / validation study (picture-based form)

Population: Three hundred four community-residing adults aged 55 to 94 (mean education 8 years) attending outpatient clinics at Baby Memorial Hospital, Kozhikode, Kerala, India; 65 were diagnosed with dementia. The Picture-based Memory Impairment Screen (PMIS) — a culture-fair picture-based screen designed to be administered by nonspecialists, scored 0–8 — was assessed against dementia diagnosis, with the Mini-Mental State Examination (MMSE) as comparator.

Summary: Picture-based form in India (Verghese 2012, Journal of the American Geriatrics Society — PMIS derivation / validation, 304 community-residing adults aged 55–94 in Kerala, India, 65 with dementia): at a cut-score of 5 sensitivity was 95.4% (95% CI 90.3 to 100.0) and specificity 99.2% (98.0 to 100.0), with better specificity than the MMSE especially at low education

Result: PMIS scores were worse in participants with dementia (1.5) than in controls (7.7, P < .001). At the optimal cut-score of 5, the PMIS had sensitivity 95.4% (95% CI 90.3 to 100.0) and specificity 99.2% (95% CI 98.0 to 100.0) for detecting dementia. In the 167 participants with <10 years of education, a score of five or less had sensitivity 97.8% and specificity 99.2%. The PMIS had better specificity than the MMSE in detecting dementia, especially in older adults with low education, as published.

Watch out: A derivation-spectrum pair: defined dementia cases against community controls in the instrument's home population — compare the US memory-centre card below, where the same form's pair collapses to 68% / 81% in consecutive complainers. Both print; the gap between them is this shelf's headline.

Source: Verghese et al. Picture-based memory impairment screen for dementia. Journal of the American Geriatrics Society. 2012. PMID: 23039180. Registry ID: none in the record. MeSH: Aged · Cross-Sectional Studies · Dementia/complications,diagnosis · Diagnostic Techniques, Neurological · Female · Humans · Male · Memory Disorders/etiology · Photography · Prospective Studies

Card 4 — Picture-based form in a US memory centre (Malik 2018, Journal of the American Geriatrics Society — PMIS in a US multidisciplinary memory centre, 405 individuals with cognitive complaints: 194 dementia / 155 MCI / 56 subjective complaints): for all-cause dementia sensitivity was 68%, specificity 81%, PPV 77% and NPV 73%, with consistent performance across ethnicity, education, sex and language

Study: Validation study (picture-based form, US clinic spectrum)

Population: Individuals with cognitive complaints (N = 405; average age 76 ± 10, 66% female) at the Montefiore Center for Aging Brain, a multidisciplinary memory disorder centre serving an ethnically and educationally diverse community; a geriatrician or neurologist administered the PMIS, and a neuropsychologist administered the Blessed Information, Memory, and Concentration (BIMC) test and determined whether participants had dementia (n = 194), mild cognitive impairment (n = 155) or subjective cognitive complaints (n = 56).

Summary: Picture-based form in a US memory centre (Malik 2018, Journal of the American Geriatrics Society — PMIS in a US multidisciplinary memory centre, 405 individuals with cognitive complaints: 194 dementia / 155 MCI / 56 subjective complaints): for all-cause dementia sensitivity was 68%, specificity 81%, PPV 77% and NPV 73%, with consistent performance across ethnicity, education, sex and language

Result: Mean PMIS scores were 4.0 ± 2.6 in participants with dementia, 6.8 ± 1.5 in those with MCI and 7.0 ± 1.8 in those with subjective complaints (p < .001), with similar significant linear trends by ethnicity, education, sex and language. The PMIS had positive predictive value 77%, negative predictive value 73%, sensitivity 68% and specificity 81% to detect all-cause dementia in this population of individuals with cognitive complaints, as published.

Watch out: The spectrum-corrected headline: in consecutive complainers at a memory centre the PMIS pair is 68% / 81% — a different instrument in practice from the 95.4% / 99.2% derivation pair in Kerala. Predictive values (77% / 73%) belong to this centre's prevalence and do not travel.

Source: Malik et al. Picture-Based Memory Impairment Screen: Effective Cognitive Screen in Ethnically Diverse Populations. Journal of the American Geriatrics Society. 2018. PMID: 29808583. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cognitive Dysfunction/diagnosis · Cohort Studies · Cross-Sectional Studies · Dementia/diagnosis · Female · Humans · Male · Mass Screening/methods · Memory Disorders/diagnosis · Mental Status and Dementia Tests/standards · Photography · Predictive Value of Tests · Psychometrics · Reproducibility of Results · Sensitivity and Specificity

Card 5 — Synthesis: one family, three different measurements — the original MIS's derivation reports discriminative validity without a printed pair, the telephone form wins a fixed-sensitivity specificity comparison (93% vs 78% / 80%), and the picture form's pair collapses from 95.4% / 99.2% in its Kerala derivation spectrum to 68% / 81% in a US memory centre

Study: Synthesis

Population: All reports carded on this shelf: the original MIS criterion validation (Buschke 1999; n = 483, 50 with dementia, programme-labelled, no pair in its abstract), the MIS-T telephone validation (Lipton 2003; n = 300, 27 with dementia, programme-labelled), the PMIS derivation / validation in Kerala, India (Verghese 2012; n = 304, 65 with dementia) and the PMIS validation in a US memory centre (Malik 2018; n = 405 with cognitive complaints) — counted as 4 reports across 3 forms of one instrument family, never as four measurements of the same test.

Summary: Synthesis: one family, three different measurements — the original MIS's derivation reports discriminative validity without a printed pair, the telephone form wins a fixed-sensitivity specificity comparison (93% vs 78% / 80%), and the picture form's pair collapses from 95.4% / 99.2% in its Kerala derivation spectrum to 68% / 81% in a US memory centre

Result: By form: MIS (in-person word recall) — derivation with good alternate-forms reliability and discriminative validity, no numerical pair published in the abstract. MIS-T (telephone) — at sensitivity fixed at 78%, specificity 93% vs category fluency 78% and TICS 80%, in 4 minutes. PMIS (picture-based) — at cut-score 5, sensitivity 95.4% / specificity 99.2% in the Kerala community derivation sample, and sensitivity 68% / specificity 81% (PPV 77%, NPV 73%) in consecutive US memory-centre complainers, with consistent performance across ethnicity, education, sex and language in the US sample. Every figure prints with its form; the PMIS gap between derivation and clinic spectra is the headline. This is a screening-accuracy shelf only.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.