T-MACS: NPV 99.3% ruling out 40.4% on its original troponin T — four reports, with troponin-I and point-of-care transfers printed as transfers

Shelf #8045 · Emergency & first hours

PREDICTIVE PERFORMANCE — assay-specific: on high-sensitivity troponin T, rule-out NPV 99.3% and sensitivity 98.1% in the three-cohort validation set (n = 1,459), ruling out 40.4%, c-statistic 0.91 (programme-labelled re-derivation); Australian / New Zealand validation sensitivity 99.1% for AMI with 19.8% very-low-risk; troponin-I transfer c-statistic 0.94 with 36.3% immediately dischargeable; point-of-care serial transfer ruled out 31.2% (sensitivity 99.0%, NPV 99.5%) and ruled in 10.4% (PPV 91.2%); composition 1 re-derivation + 3 validations, two of them assay transfers; a decision-aid accuracy stamp, not a pathway-implementation stamp

Stamped: 2026-11-28.

Evidence published: 2017–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does the T-MACS decision aid (Troponin-only Manchester Acute Coronary Syndromes — symptoms, ECG and a single arrival high-sensitivity troponin T, output as a probability grouping patients from very-low to high risk) rule out and rule in acute coronary syndrome — what performance did the re-derivation with external validation in three cohorts achieve, and what did the Australian / New Zealand validation, the troponin-I validation and the point-of-care validation find?

Balance of the evidence

Composition prints: 1 re-derivation with three-cohort external validation (programme-labelled; secondary analyses of prior cohorts) + 3 validations — one on the original high-sensitivity troponin T, two assay transfers (contemporary troponin I; point-of-care troponin I with serial testing) — counted as that composition. A decision-aid accuracy shelf, not a pathway-implementation shelf (implementation is live #806's territory for the HEART Pathway, a different aid). Assay prints with every figure — the aid was built on high-sensitivity troponin T, and the troponin-I and point-of-care validations are assay transfers whose pairs may not be printed as the original assay's. Outcome prints (ACS including 30-day events vs AMI alone in the Australian / New Zealand validation). The rule-in limb is small in every study (4.7%–10.4% of patients) and its PPV prints with its N. Cross-points in prose only to the chest-pain family: Vancouver Chest Pain Rule (#8044), EDACS (#7924), Marburg Heart Score (#7960), Gencer score (#7961), INTERCHEST (#7962) and the HEART Pathway at live #806 — the HEART score itself is NOT rowed and NOT carded here.

MeSH: Acute Coronary Syndrome/diagnosis · Adolescent · Adult · Aged · Aged, 80 and over · Biomarkers/analysis,blood · Cohort Studies · Decision Support Techniques · Emergency Service, Hospital/organization & administration · Fatty Acid Binding Protein 3/analysis,blood · Female · Humans · Logistic Models · Male · Middle Aged · Predictive Value of Tests · Prevalence · Prospective Studies · Troponin T/analysis,blood · Acute Coronary Syndrome/classification,diagnosis · Australia · Chest Pain/complications,diagnosis · Emergency Service, Hospital/organization & administration,statistics & numerical data · Myocardial Infarction/diagnosis · Troponin/analysis,blood · Troponin I/analysis,blood · Acute Coronary Syndrome/diagnosis,physiopathology · Biomarkers/blood · Chest Pain/diagnosis · Emergency Service, Hospital/statistics & numerical data · Fatty Acid-Binding Proteins/blood · Hospitalization/statistics & numerical data · Troponin T/blood · United Kingdom · Acute Coronary Syndrome/blood,diagnosis · Emergency Service, Hospital · England · Point-of-Care Testing · Reproducibility of Results · Risk Assessment · Risk Factors · Time Factors · Troponin I/blood · Up-Regulation · Workflow

Cards (5)

Card 1 — Re-derivation with external validation (Body 2017, Emergency Medicine Journal — re-derivation and external validation in three cohorts; secondary analyses of four prospective diagnostic cohorts): in the derivation set (n = 703) the rule-out threshold had NPV 99.3% and sensitivity 98.7%, ruling out 37.7%; in the three-cohort validation set (n = 1,459) NPV was 99.3% and sensitivity 98.1%, ruling out 40.4%, with c-statistic 0.91 — programme-labelled: the Body / Manchester group's own report

Study: Re-derivation and external validation — programme-labelled (the Manchester group's own report); secondary analyses of prior cohorts

Population: Secondary analyses from four prospective diagnostic cohort studies of patients presenting to the ED with suspected acute coronary syndromes, with high-sensitivity cardiac troponin T (hs-cTnT) measured on arrival. T-MACS was built in one cohort (derivation set, n = 703) and validated in three external cohorts (validation set, n = 1,459). The primary outcome was ACS, defined as prevalent acute MI or incident death, AMI or coronary revascularisation within 30 days.

Summary: Re-derivation with external validation (Body 2017, Emergency Medicine Journal — re-derivation and external validation in three cohorts; secondary analyses of four prospective diagnostic cohorts): in the derivation set (n = 703) the rule-out threshold had NPV 99.3% and sensitivity 98.7%, ruling out 37.7%; in the three-cohort validation set (n = 1,459) NPV was 99.3% and sensitivity 98.1%, ruling out 40.4%, with c-statistic 0.91 — programme-labelled: the Body / Manchester group's own report

Result: At the rule-out threshold, in the derivation set T-MACS had negative predictive value 99.3% (95% CI 97.3% to 99.9%) and sensitivity 98.7% (95.3% to 99.8%), ruling out 37.7% of patients (specificity 47.6%, positive predictive value 34.0%). In the validation set, NPV was 99.3% (98.3% to 99.8%) and sensitivity 98.1% (95.2% to 99.5%), ruling out 40.4% (n = 590) (specificity 47.0%, PPV 23.9%). T-MACS would rule in 10.1% (derivation) and 4.7% (validation) of patients, of whom 100.0% and 91.3% had ACS. C-statistics for T-MACS (0.91) and the original MACS (0.90) were similar on validation, as published.

Watch out: Programme-labelled, and a secondary analysis of prior cohorts, printed as such: the derivation and its three validation cohorts were assembled by the group that built the aid. The aid was built on high-sensitivity troponin T — the troponin-I and point-of-care cards below are assay transfers, not the original assay's performance.

Source: Body et al. Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid: single biomarker re-derivation and external validation in three cohorts. Emergency medicine journal : EMJ. 2017. PMID: 27565197. Registry ID: none in the record. MeSH: Acute Coronary Syndrome/diagnosis · Adolescent · Adult · Aged · Aged, 80 and over · Biomarkers/analysis,blood · Cohort Studies · Decision Support Techniques · Emergency Service, Hospital/organization & administration · Fatty Acid Binding Protein 3/analysis,blood · Female · Humans · Logistic Models · Male · Middle Aged · Predictive Value of Tests · Prevalence · Prospective Studies · Troponin T/analysis,blood

Card 2 — Australian / New Zealand validation (Greenslade 2017, Emergency Medicine Journal — validation in two Australian / New Zealand EDs, 1,244 patients, 9.2% with AMI): T-MACS classed 19.8% very-low-risk with one false negative — sensitivity 99.1% (95.2 to 100) for AMI; its MACS limbs print as comparators

Study: Validation study (high-sensitivity troponin T)

Population: Prospectively collected data from two EDs in Australia and New Zealand (n = 1,244; 114 patients, 9.2%, diagnosed with AMI and 163, 13.1%, with major adverse cardiac events). Patients were assigned a probability of ACS based on the MACS and T-MACS rules, incorporating high-sensitivity troponin T, heart-type fatty acid-binding protein, ECG results and clinical symptoms; the primary endpoint was 30-day diagnosis of AMI and the secondary endpoint 30-day major adverse cardiac events including AMI, revascularisation or coronary stenosis >70%.

Summary: Australian / New Zealand validation (Greenslade 2017, Emergency Medicine Journal — validation in two Australian / New Zealand EDs, 1,244 patients, 9.2% with AMI): T-MACS classed 19.8% very-low-risk with one false negative — sensitivity 99.1% (95.2 to 100) for AMI; its MACS limbs print as comparators

Result: The MACS and T-MACS rules categorised 133 (10.7%) and 246 (19.8%) patients respectively as very low risk and potentially suitable for early discharge. There was one false negative case for both rules, making sensitivity 99.1% (95.2% to 100%). The authors concluded that MACS and T-MACS accurately risk-stratify very low risk patients, that T-MACS would allow more patients to be discharged early, and that the potential for missed major adverse cardiac events means further outpatient testing for coronary artery disease may be required for patients identified as very low risk, as published.

Watch out: Outcome prints: the primary endpoint here is AMI alone at 30 days, not the broader ACS composite (including 30-day events) of the derivation — the 99.1% sensitivities answer different outcomes and may not be merged. The MACS limbs of this study print as comparators only; MACS is a different (two-biomarker) aid.

Source: Greenslade et al. Validating the Manchester Acute Coronary Syndromes (MACS) and Troponin-only Manchester Acute Coronary Syndromes (T-MACS) rules for the prediction of acute myocardial infarction in patients presenting to the emergency department with chest pain. Emergency medicine journal : EMJ. 2017. PMID: 28363994. Registry ID: none in the record. MeSH: Acute Coronary Syndrome/classification,diagnosis · Adult · Aged · Australia · Chest Pain/complications,diagnosis · Decision Support Techniques · Emergency Service, Hospital/organization & administration,statistics & numerical data · Female · Humans · Male · Middle Aged · Myocardial Infarction/diagnosis · Prospective Studies · Troponin/analysis,blood · Troponin I/analysis,blood · Troponin T/analysis,blood

Card 3 — Troponin-I validation (Va Den Berg 2018, American Journal of Emergency Medicine — validation with a contemporary troponin I assay; secondary analysis, n = 405, 18.8% with ACS): T-MACS c-statistic 0.94 with sensitivity comparable to MACS but significantly greater specificity; 36.3% immediately dischargeable and one (0.7%) very-low-risk patient with ACS

Study: Validation study — assay transfer (contemporary troponin I); secondary analysis

Population: A secondary analysis from a prospective diagnostic cohort study at Stepping Hill Hospital, United Kingdom: patients presenting with chest pain of suspected cardiac nature warranting rule-out for ACS (n = 405; 76, 18.8%, had ACS, defined as prevalent AMI or incident major adverse cardiac events — death, AMI or coronary revascularisation — within 30 days). Both MACS and T-MACS were validated using the contemporary Siemens Advia Centaur cardiac troponin I assay.

Summary: Troponin-I validation (Va Den Berg 2018, American Journal of Emergency Medicine — validation with a contemporary troponin I assay; secondary analysis, n = 405, 18.8% with ACS): T-MACS c-statistic 0.94 with sensitivity comparable to MACS but significantly greater specificity; 36.3% immediately dischargeable and one (0.7%) very-low-risk patient with ACS

Result: MACS and T-MACS had similar c-statistics (0.94 for each, p = 0.36) and sensitivity (difference 1.3%, 95% CI −1.3 to 3.9%, p = 1.00), but T-MACS had significantly greater specificity (difference 16.7%, 95% CI 14.6 to 18.9%, p < 0.0001). T-MACS and MACS would have allowed 36.3% and 22.5% of patients to be immediately discharged respectively. Of patients classified as very low risk, none had ACS when MACS was used, compared with one (0.7%) with T-MACS, as published.

Watch out: Assay transfer prints: T-MACS was built on high-sensitivity troponin T; this validation substitutes a contemporary troponin I assay, and its figures are that assay's performance with the aid, not the original assay's. A secondary analysis of a prior cohort, printed as such.

Source: Va Den Berg et al. Validation of the (Troponin-only) Manchester ACS decision aid with a contemporary cardiac troponin I assay. The American journal of emergency medicine. 2018. PMID: 29079376. Registry ID: none in the record. MeSH: Acute Coronary Syndrome/diagnosis,physiopathology · Aged · Aged, 80 and over · Biomarkers/blood · Chest Pain/diagnosis · Decision Support Techniques · Emergency Service, Hospital/statistics & numerical data · Fatty Acid-Binding Proteins/blood · Female · Hospitalization/statistics & numerical data · Humans · Male · Middle Aged · Predictive Value of Tests · Prospective Studies · Troponin T/blood · United Kingdom

Card 4 — Point-of-care validation (Body 2019, Heart — prospective diagnostic-accuracy study of T-MACS with a point-of-care troponin I assay at eight EDs, 716 patients, 14.7% with ACS): serial point-of-care testing ruled out 31.2% with sensitivity 99.0% (94.4 to 100.0) and NPV 99.5%, and ruled in 10.4% with PPV 91.2% and specificity 98.9% — programme-labelled: the Manchester group's own report

Study: Validation study — assay transfer (point-of-care troponin I, serial testing); programme-linked report

Population: A prospective diagnostic accuracy study at eight EDs in England including patients with suspected acute coronary syndromes (n = 716; 105, 14.7%, had ACS). Blood drawn on arrival and 3 hours later was analysed for point-of-care cardiac troponin I (i-Stat, Abbott Point of Care). The primary outcome was a diagnosis of ACS, including an adjudicated diagnosis of AMI based on serial laboratory troponin testing and major adverse cardiac events (death, AMI or coronary revascularisation) within 30 days.

Summary: Point-of-care validation (Body 2019, Heart — prospective diagnostic-accuracy study of T-MACS with a point-of-care troponin I assay at eight EDs, 716 patients, 14.7% with ACS): serial point-of-care testing ruled out 31.2% with sensitivity 99.0% (94.4 to 100.0) and NPV 99.5%, and ruled in 10.4% with PPV 91.2% and specificity 98.9% — programme-labelled: the Manchester group's own report

Result: Using serial point-of-care troponin I concentrations over 3 hours could have ruled out ACS in 198 patients (31.2%) with sensitivity 99.0% (95% CI 94.4% to 100.0%) and negative predictive value 99.5% (95% CI 96.5% to 99.9%); no AMIs were missed. T-MACS ruled in ACS for 65 patients (10.4%) with positive predictive value 91.2% (95% CI 82.1% to 95.9%) and specificity 98.9% (97.6% to 99.6%), as published.

Watch out: Two transfers at once: a point-of-care troponin I assay (not the high-sensitivity troponin T the aid was built on) and serial testing over 3 hours (not the single arrival sample of the derivation) — its pairs are that pathway's, not the original single-test aid's. The rule-in limb is 65 patients (10.4%); its PPV prints with that N.

Source: Body et al. Diagnostic accuracy of the T-MACS decision aid with a contemporary point-of-care troponin assay. Heart (British Cardiac Society). 2019. PMID: 30636217. Registry ID: none in the record. MeSH: Acute Coronary Syndrome/blood,diagnosis · Adult · Aged · Aged, 80 and over · Biomarkers/blood · Decision Support Techniques · Emergency Service, Hospital · England · Female · Humans · Male · Middle Aged · Point-of-Care Testing · Predictive Value of Tests · Prospective Studies · Reproducibility of Results · Risk Assessment · Risk Factors · Time Factors · Troponin I/blood · Up-Regulation · Workflow

Card 5 — Synthesis: T-MACS rules out roughly a third to two-fifths of ED chest-pain patients at NPV 99.3%–99.5% and sensitivity 98.1%–99.1% across its derivation-validation and three assay / outcome transfers — but each transfer (troponin I, point-of-care serial testing, AMI-only outcome) answers a slightly different question, and the figures print with their assay and outcome, never merged

Study: Synthesis

Population: All reports carded on this shelf: the re-derivation with three-cohort external validation (Body 2017; derivation n = 703, validation n = 1,459, programme-labelled, secondary analyses), the Australian / New Zealand validation (Greenslade 2017; n = 1,244, AMI outcome), the troponin-I validation (Va Den Berg 2018; n = 405, secondary analysis) and the point-of-care validation (Body 2019; n = 716, programme-linked) — 4 reports, counted as that composition.

Summary: Synthesis: T-MACS rules out roughly a third to two-fifths of ED chest-pain patients at NPV 99.3%–99.5% and sensitivity 98.1%–99.1% across its derivation-validation and three assay / outcome transfers — but each transfer (troponin I, point-of-care serial testing, AMI-only outcome) answers a slightly different question, and the figures print with their assay and outcome, never merged

Result: Rule-out: derivation set NPV 99.3% / sensitivity 98.7%, ruling out 37.7%; validation set NPV 99.3% / sensitivity 98.1%, ruling out 40.4%, c-statistic 0.91. ANZ validation: 19.8% very-low-risk, one false negative, sensitivity 99.1% for AMI. Troponin-I transfer: c-statistic 0.94, 36.3% immediately dischargeable, one (0.7%) very-low-risk patient with ACS. Point-of-care serial transfer: ruled out 31.2% (sensitivity 99.0%, NPV 99.5%) and ruled in 10.4% (PPV 91.2%, specificity 98.9%). The rule-in limb is small in every study (4.7%–10.4% of patients) and its PPV prints with its N. Cross-points in prose only to the chest-pain family: the Vancouver Chest Pain Rule (pack #8044), EDACS (#7924), the Marburg Heart Score (#7960), the Gencer score (#7961), INTERCHEST (#7962) and the HEART Pathway at live #806 — the HEART score itself is not rowed and not carded here; pathway implementation is live #806's territory for a different aid. This is a decision-aid accuracy shelf only.

Watch out: See the individual cards for each report's limits; this synthesis adds no new data.

Source: Synthesis of the reports carded above; no additional source.