SourceMed · Shelf #8049 in the ask interface
RADAR for delirium: 73% / 67% against DSM-IV-TR in derivation vs 95% / 80% against the CAM in Italy — 2 delirium reports + 1 same-cohort secondary analysis
Shelf #8049 · Brain, stroke & mind
PREDICTIVE PERFORMANCE — reference-standard-dependent: sensitivity 73% / specificity 67% against DSM-IV-TR delirium in derivation vs sensitivity 95% / specificity 80% against CAM-defined delirium in the Italian validation; composition 2 delirium reports + 1 same-cohort secondary analysis (different target), counted as such — never 3 independent validations; a screening-accuracy stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2015–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does RADAR (Recognizing Acute Delirium As part of your Routine — three nurse-observation items assessed during medication rounds, taking seconds) detect delirium — what sensitivity and specificity did the original hospital / long-term-care validation find against DSM-IV-TR delirium, what did the Italian hospital validation find against the CAM, and how did the scale perform for its 'sixth vital sign' composite in the secondary analysis?
Balance of the evidence
Composition prints on the face: 2 delirium reports + 1 same-cohort secondary analysis — never 3 independent validations. The two delirium reports use different reference standards and their pairs may not be merged or averaged: the derivation (programme-labelled: the Voyer group's own report) found sensitivity 73% and specificity 67% against CAM-operationalised DSM-IV-TR delirium in 193 hospital / long-term-care participants, while the Italian validation found sensitivity 95%, specificity 80%, PPV 60% and NPV 98% against CAM-defined delirium — agreement with another screen in a 25%-prevalence ward sample, not accuracy against a DSM diagnosis. The third card is a secondary analysis of the same derivation cohort (n = 193) for a different target — a 'positive sixth vital sign' (altered consciousness plus inattention, CAM-assessed), not delirium itself — and is counted as such. A 7-second observation tool's ceiling is set by what medication-round observation can see: hypoactive presentations are the expected miss pattern, and the derivation's modest pair (73% / 67%) is the honest headline. This is a screening-accuracy shelf, not a treatment shelf. Cross-points: original CAM (#8046), bCAM (#8047), DOSS (#8048) and Nu-DESC (#7753) — different nurse-observation approaches, no anchor shared.
MeSH: Brief Psychiatric Rating Scale/standards · Cognitive Dysfunction/diagnosis · Delirium/diagnosis · Hospitals · Humans · Nursing Homes · Sensitivity and Specificity
Cards (4)
Card 1 — Derivation / validation (Voyer 2015, BMC Nursing — 142 hospital patients and 51 long-term-care residents aged ≥65, 193 total, assessed by 139 trained nurses against CAM-operationalised DSM-IV-TR delirium): sensitivity 73% and specificity 67%, item agreement between bedside nurses and research assistants 82%–98%, mean administration ~7 seconds, acceptability ≥98% — programme-labelled: the Voyer group's own report
Study: Derivation / validation study (primary delirium report 1 of 2) — programme-labelled
Population: 142 patients on three acute-care hospital units (medical, cardiology, coronary care) and 51 residents on five long-term-care units, all aged 65 years or over, with or without dementia; 139 nurses were trained to use RADAR during scheduled medication distribution over a 12-hour data-collection period; delirium was defined as meeting DSM-IV-TR criteria, with the CAM used by researchers to determine delirium symptoms.
Summary: Derivation / validation (Voyer 2015, BMC Nursing — 142 hospital patients and 51 long-term-care residents aged ≥65, 193 total, assessed by 139 trained nurses against CAM-operationalised DSM-IV-TR delirium): sensitivity 73% and specificity 67%, item agreement between bedside nurses and research assistants 82%–98%, mean administration ~7 seconds, acceptability ≥98% — programme-labelled: the Voyer group's own report
Result: Percentages of agreement between RADAR items administered by bedside nurses and by research assistants varied from 82% to 98%. Against DSM-IV-TR criterion-defined delirium, RADAR had sensitivity 73% and specificity 67%. Nursing staff took about seven seconds on average to complete the tool and it was very well received (≥98%) overall, as published.
Watch out: Programme-labelled derivation and the honest headline pair: 73% / 67% in the originator group's own mixed hospital / long-term-care sample. Its PubMed record carries no MeSH terms — the source line prints 'none in the record' verbatim.
Source: Voyer et al. Recognizing acute delirium as part of your routine [RADAR]: a validation study. BMC nursing. 2015. PMID: 25844067. Registry ID: none in the record. MeSH: none in the record
Card 2 — Italian hospital validation (Fabrizi 2024, Healthcare — 150 patients aged ≥70 against CAM-defined delirium as the reference standard, 25% CAM-positive): AUC 0.916; at the previously suggested cut-off sensitivity 95%, specificity 80%, PPV 60% and NPV 98%
Study: External validation against the CAM (primary delirium report 2 of 2)
Population: 150 hospitalised patients aged 70 years or older in an Italian hospital (60% female; median age 84 years); 37 (25%) were classified as experiencing delirium by the CAM and 58 (39%) by the RADAR scale.
Summary: Italian hospital validation (Fabrizi 2024, Healthcare — 150 patients aged ≥70 against CAM-defined delirium as the reference standard, 25% CAM-positive): AUC 0.916; at the previously suggested cut-off sensitivity 95%, specificity 80%, PPV 60% and NPV 98%
Result: The area under the ROC curve of the RADAR scale was 0.916. At the cut-off suggested by previous research, RADAR showed sensitivity 95%, specificity 80%, positive predictive value 60% and negative predictive value 98% against CAM criterion-defined delirium, as published.
Watch out: Reference standard is the CAM — another screen, not a DSM diagnosis: 95% / 80% measures agreement with the CAM in a 25%-prevalence ward sample and may not be merged with, averaged with, or ranked above the derivation's DSM-referenced 73% / 67%. Its PubMed record carries no MeSH terms — the source line prints 'none in the record' verbatim.
Source: Fabrizi et al. Diagnostic Accuracy of the Recognizing Acute Delirium as Part of Your Routine (RADAR) Scale for Delirium Assessment in Hospitalized Older Adults: A Cross-Sectional Study. Healthcare (Basel, Switzerland). 2024. PMID: 38998829. Registry ID: none in the record. MeSH: none in the record
Card 3 — Same-cohort secondary analysis (Voyer 2016, Clinical Nursing Research — secondary analysis of the derivation cohort, n = 193, for a different target: a 'positive sixth vital sign' — altered consciousness plus inattention, CAM-assessed — not delirium itself): sensitivity 70% and specificity 83%, PPV 71% — labelled a secondary analysis of the derivation cohort with a different target; it is not an independent delirium validation
Study: Secondary analysis of the derivation cohort — different target (sixth vital sign), NOT an independent delirium validation
Population: The same 193 participants as the derivation study (one acute-care hospital and one long-term care facility); the primary outcome was a positive sixth vital sign, defined as the presence of both an altered level of consciousness and inattention, assessed using the CAM; 43 participants had a positive sixth vital sign.
Summary: Same-cohort secondary analysis (Voyer 2016, Clinical Nursing Research — secondary analysis of the derivation cohort, n = 193, for a different target: a 'positive sixth vital sign' — altered consciousness plus inattention, CAM-assessed — not delirium itself): sensitivity 70% and specificity 83%, PPV 71% — labelled a secondary analysis of the derivation cohort with a different target; it is not an independent delirium validation
Result: RADAR identified 30 of the 43 participants with a positive sixth vital sign and 58 of 70 without, yielding sensitivity 70% and specificity 83% respectively, with positive predictive value 71%, as published.
Watch out: Composition discipline: this card shares its cohort with the derivation card and answers a different question (sixth-vital-sign composite, not delirium). The shelf's count is 2 delirium reports + 1 same-cohort secondary analysis — never 3 independent validations.
Source: Voyer et al. RADAR: A Measure of the Sixth Vital Sign? Clinical nursing research. 2016. PMID: 26337503. Registry ID: none in the record. MeSH: Brief Psychiatric Rating Scale/standards · Cognitive Dysfunction/diagnosis · Delirium/diagnosis · Hospitals · Humans · Nursing Homes · Sensitivity and Specificity
Card 4 — Synthesis: RADAR is a ~7-second medication-round observation screen whose delirium accuracy is modest against DSM criteria (73% / 67% in derivation) and higher against the CAM (95% / 80%) — two reference standards, two different claims, plus one same-cohort secondary analysis of a different target
Study: Synthesis
Population: Synthesis of the reports carded above: 2 delirium reports (193 derivation participants + 150 Italian validation patients) + 1 same-cohort secondary analysis of the derivation cohort (n = 193, not additional patients).
Summary: Synthesis: RADAR is a ~7-second medication-round observation screen whose delirium accuracy is modest against DSM criteria (73% / 67% in derivation) and higher against the CAM (95% / 80%) — two reference standards, two different claims, plus one same-cohort secondary analysis of a different target
Result: Against CAM-operationalised DSM-IV-TR delirium the derivation found sensitivity 73% and specificity 67% with ~7-second administration and ≥98% nurse acceptability. Against CAM-defined delirium the Italian validation found AUC 0.916 with sensitivity 95%, specificity 80%, PPV 60% and NPV 98%. The secondary analysis found sensitivity 70% and specificity 83% for a sixth-vital-sign composite in the derivation cohort. No pooled pair is printed: the two delirium pairs use different reference standards (DSM-IV-TR criteria vs the CAM) and may not be merged or averaged.
Watch out: Never present this shelf as 3 independent validations. Hypoactive presentations are the expected miss pattern for a seconds-long observation tool. Cross-points in prose only: original CAM (#8046), bCAM (#8047), DOSS (#8048), Nu-DESC (#7753).
Source: Synthesis of the reports carded above; no additional source.