SourceMed · Shelf #8055 in the ask interface

Heart-failure bedside examination in acute dyspnoea — FLOOR-RISK: exactly 2 overlapping syntheses; signs rule in (S3 LR+ 11, specificity 0.97) and cannot rule out (pooled sensitivities <0.55)

Shelf #8055 · Heart, vessels, blood pressure & clotting

DIAGNOSTIC ACCURACY — FLOOR-RISK, rule-in only, rule-out NOT ESTABLISHED: exactly 2 overlapping syntheses and no primary report (RCE PMID 16234501 + dyspnoea SR/MA PMID 29252938; overlap in question, population, signs and primary-study scope, scoped not enumerated); S3 positive likelihood ratio 11 (relative measure) and pooled specificity 0.97 rule in, while pooled sensitivities below 0.55 mean absence of signs cannot exclude heart failure; a diagnostic-accuracy stamp on the SCOFF / Amsler FLOOR-RISK precedent, not a management stamp

Stamped: 2026-11-28.

Evidence published: 2005–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults presenting with acute dyspnoea, how accurately do the bedside heart-failure signs — the third heart sound (S3 gallop), elevated jugular venous pressure, peripheral oedema, displaced apex and rales / crepitations — identify heart failure — what likelihood ratios does the Rational Clinical Examination give, and what pooled sensitivities, specificities and likelihood ratios does the acute-dyspnoea signs systematic review / meta-analysis give? FLOOR-RISK: this question rests on exactly 2 overlapping syntheses (PMIDs 16234501 and 29252938) and no primary report, on the SCOFF / Amsler precedent, with the overlap scoped rather than enumerated.

Balance of the evidence

FLOOR-RISK basis (exact): this shelf rests on exactly 2 overlapping syntheses and no primary report — the Rational Clinical Examination synthesis (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies with complete data, 4,737 patients). The two syntheses overlap in question, population (acute dyspnoea), signs (third heart sound, jugular venous pressure, oedema, rales / crepitations) and — given the small pre-2005 primary literature both draw on — in primary-study scope, although study-level overlap was scoped, not enumerated, from the abstracts. This is the SCOFF / Amsler precedent's composition, and the shelf is built only on that precedent. Every card on this shelf is a labelled slice of one of these two syntheses' component findings — the ≥4-card format is met by slicing, never by inventing a third source. Both syntheses agree the signs rule IN far better than they rule OUT: the dyspnoea meta-analysis's pooled sensitivities remained below 0.55, so no card may present absence of a third heart sound, normal jugular venous pressure or absent oedema as excluding heart failure. The RCE's likelihood-ratio headline (third heart sound positive LR 11, 95% CI 4.9 to 25.0 — a relative measure, labelled as such) comes from its included-study synthesis and prints with its interval. Radiographic pulmonary venous congestion inside the RCE (positive LR 12.0) is NOT a bedside sign and is not carded as one; the RCE's BNP and ECG findings are likewise non-examination tests and appear only as labelled context, never as examination accuracy. This is a diagnostic-accuracy shelf, not a management shelf. Cross-point in prose: the auscultation shelf (Slate 27 row S27-4-06) — a neighbouring examination-accuracy question, no anchor shared.

MeSH: Adult · Aged · Diagnostic Techniques, Cardiovascular · Dyspnea/etiology,physiopathology · Electrocardiography · Emergency Service, Hospital · Female · Heart Failure/diagnosis,physiopathology · Humans · Male · Middle Aged · Natriuretic Peptide, Brain/blood · Physical Examination · Radiography, Thoracic · Valsalva Maneuver · Acute Coronary Syndrome/diagnosis · Asthma/diagnosis · Dyspnea/diagnosis,epidemiology · Heart Failure/diagnosis · Physical Examination/statistics & numerical data · Pulmonary Disease, Chronic Obstructive/diagnosis

Cards (5)

Card 1 — FLOOR-RISK slice 1 of 2 syntheses — RCE rule-in examination signs (Wang 2005, JAMA — Rational Clinical Examination, 22 studies of dyspnoeic ED patients): the third heart sound (S3) gallop had the strongest examination sign, positive likelihood ratio 11 (95% CI 4.9 to 25.0), a relative measure labelled as such — labelled slice of synthesis 1 of exactly 2; not an independent source

Study: Labelled slice of synthesis 1 of exactly 2 (Rational Clinical Examination) — FLOOR-RISK composition

Population: 22 studies of various findings for diagnosing heart failure in adult patients presenting with dyspnoea to the emergency department, retained from MEDLINE (1966–July 2005), reference lists, prior reviews and physical-examination textbooks; two authors independently abstracted sensitivity, specificity and likelihood ratios and assessed methodological quality. Slice 1 of the RCE's component findings: examination signs that increase the probability of heart failure.

Summary: FLOOR-RISK slice 1 of 2 syntheses — RCE rule-in examination signs (Wang 2005, JAMA — Rational Clinical Examination, 22 studies of dyspnoeic ED patients): the third heart sound (S3) gallop had the strongest examination sign, positive likelihood ratio 11 (95% CI 4.9 to 25.0), a relative measure labelled as such — labelled slice of synthesis 1 of exactly 2; not an independent source

Result: Among examination signs, the presence of the third heart sound (S3) gallop best increased the probability of heart failure (positive likelihood ratio = 11; 95% CI 4.9 to 25.0 — a relative measure, labelled as such). For context within the same synthesis, the best history feature was past history of heart failure (positive LR 5.8; 95% CI 4.1 to 8.0) and the best symptom was paroxysmal nocturnal dyspnoea (positive LR 2.6; 95% CI 1.5 to 4.5), as published. The RCE's chest-radiograph finding (pulmonary venous congestion, positive LR 12.0) is not a bedside sign and is not carded as one.

Watch out: FLOOR-RISK basis (exact): this shelf rests on exactly 2 overlapping syntheses and no primary report — the Rational Clinical Examination synthesis (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies with complete data, 4,737 patients). The two syntheses overlap in question, population (acute dyspnoea), signs (third heart sound, jugular venous pressure, oedema, rales / crepitations) and — given the small pre-2005 primary literature both draw on — in primary-study scope, although study-level overlap was scoped, not enumerated, from the abstracts. This is the SCOFF / Amsler precedent's composition, and the shelf is built only on that precedent.

Source: Wang et al. Does this dyspneic patient in the emergency department have congestive heart failure? JAMA. 2005. PMID: 16234501. Registry ID: none in the record. MeSH: Adult · Aged · Diagnostic Techniques, Cardiovascular · Dyspnea/etiology,physiopathology · Electrocardiography · Emergency Service, Hospital · Female · Heart Failure/diagnosis,physiopathology · Humans · Male · Middle Aged · Natriuretic Peptide, Brain/blood · Physical Examination · Radiography, Thoracic · Valsalva Maneuver

Card 2 — FLOOR-RISK slice 2 of 2 syntheses — RCE rule-out limits (Wang 2005, JAMA — same Rational Clinical Examination synthesis, 22 studies): the examination's best probability-decreasing features were weak — absence of rales had negative likelihood ratio 0.51 (95% CI 0.37 to 0.70), a relative measure labelled as such — labelled slice of synthesis 1 of exactly 2; not an independent source

Study: Labelled slice of synthesis 1 of exactly 2 (Rational Clinical Examination) — FLOOR-RISK composition

Population: The same 22-study Rational Clinical Examination synthesis as slice 1 (adult ED patients presenting with dyspnoea). Slice 2 of the RCE's component findings: features whose ABSENCE decreases the probability of heart failure.

Summary: FLOOR-RISK slice 2 of 2 syntheses — RCE rule-out limits (Wang 2005, JAMA — same Rational Clinical Examination synthesis, 22 studies): the examination's best probability-decreasing features were weak — absence of rales had negative likelihood ratio 0.51 (95% CI 0.37 to 0.70), a relative measure labelled as such — labelled slice of synthesis 1 of exactly 2; not an independent source

Result: The features that best decreased the probability of heart failure were the absence of past history of heart failure (negative LR 0.45; 95% CI 0.38 to 0.53), the absence of dyspnoea on exertion (negative LR 0.48; 95% CI 0.35 to 0.67) and the absence of rales (negative LR 0.51; 95% CI 0.37 to 0.70) — relative measures, labelled as such. Within the same synthesis, non-examination tests performed differently (chest radiograph cardiomegaly absence negative LR 0.33; serum BNP below 100 pg/mL negative LR 0.11) — printed here only as labelled non-bedside context, never as examination accuracy, as published.

Watch out: Rule-out weakness prints: an examination negative LR of ~0.5 halves the odds at best — absence of rales does not exclude heart failure. FLOOR-RISK basis (exact): this shelf rests on exactly 2 overlapping syntheses and no primary report — the Rational Clinical Examination synthesis (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies with complete data, 4,737 patients). The two syntheses overlap in question, population (acute dyspnoea), signs (third heart sound, jugular venous pressure, oedema, rales / crepitations) and — given the small pre-2005 primary literature both draw on — in primary-study scope, although study-level overlap was scoped, not enumerated, from the abstracts. This is the SCOFF / Amsler precedent's composition, and the shelf is built only on that precedent.

Source: Wang et al. Does this dyspneic patient in the emergency department have congestive heart failure? JAMA. 2005. PMID: 16234501. Registry ID: none in the record. MeSH: Adult · Aged · Diagnostic Techniques, Cardiovascular · Dyspnea/etiology,physiopathology · Electrocardiography · Emergency Service, Hospital · Female · Heart Failure/diagnosis,physiopathology · Humans · Male · Middle Aged · Natriuretic Peptide, Brain/blood · Physical Examination · Radiography, Thoracic · Valsalva Maneuver

Card 3 — FLOOR-RISK slice 1 of the second synthesis — dyspnoea SR/MA sensitivity failure (Renier 2018, European Journal of Emergency Medicine — systematic review / meta-analysis; 8 ED studies with complete data, 4,737 patients, heart-failure prevalence 25–59%): pooled sensitivities of individual signs remained poor (below 0.55) — elevated JVP 0.19–0.70, oedema 0.29–0.77, rales 0.32–0.88 across studies — labelled slice of synthesis 2 of exactly 2; not an independent source

Study: Labelled slice of synthesis 2 of exactly 2 (acute-dyspnoea SR/MA) — FLOOR-RISK composition

Population: 8 emergency-department studies with complete data (4,737 patients) from 24 identified studies of diagnostic accuracy of signs and symptoms in adult patients with a new episode of acute dyspnoea presenting to a GP or emergency physician; study quality assessed with QUADAS; results pooled with a random-effects model. Slice 1 of this synthesis's component findings: sensitivity of the bedside signs for heart failure.

Summary: FLOOR-RISK slice 1 of the second synthesis — dyspnoea SR/MA sensitivity failure (Renier 2018, European Journal of Emergency Medicine — systematic review / meta-analysis; 8 ED studies with complete data, 4,737 patients, heart-failure prevalence 25–59%): pooled sensitivities of individual signs remained poor (below 0.55) — elevated JVP 0.19–0.70, oedema 0.29–0.77, rales 0.32–0.88 across studies — labelled slice of synthesis 2 of exactly 2; not an independent source

Result: Sensitivity was poor for elevated jugular venous pressure (0.19–0.70), rales (0.32–0.88) and peripheral oedema (0.29–0.77) across studies, and the pooled sensitivities remained poor: below 0.55. Sensitivity was very poor for fever (0.05) and sputum production (0.06) and poor for fatigue (0.36–0.76), orthopnoea (0.2–0.76) and paroxysmal nocturnal dyspnoea (0.23–0.70). Heterogeneity was present in all analyses. The reviewers conclude no single sign or symptom had acceptable sensitivity to rule out heart failure, as published.

Watch out: This is the shelf's central caution: with pooled sensitivities below 0.55, a normal examination misses roughly half or more of heart failure in acute dyspnoea. FLOOR-RISK basis (exact): this shelf rests on exactly 2 overlapping syntheses and no primary report — the Rational Clinical Examination synthesis (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies with complete data, 4,737 patients). The two syntheses overlap in question, population (acute dyspnoea), signs (third heart sound, jugular venous pressure, oedema, rales / crepitations) and — given the small pre-2005 primary literature both draw on — in primary-study scope, although study-level overlap was scoped, not enumerated, from the abstracts. This is the SCOFF / Amsler precedent's composition, and the shelf is built only on that precedent.

Source: Renier et al. Signs and symptoms in adult patients with acute dyspnea: a systematic review and meta-analysis. European journal of emergency medicine : official journal of the European Society for Emergency Medicine. 2018. PMID: 29252938. Registry ID: none in the record. MeSH: Acute Coronary Syndrome/diagnosis · Adult · Asthma/diagnosis · Dyspnea/diagnosis,epidemiology · Emergency Service, Hospital · Heart Failure/diagnosis · Humans · Male · Physical Examination/statistics & numerical data · Pulmonary Disease, Chronic Obstructive/diagnosis

Card 4 — FLOOR-RISK slice 2 of the second synthesis — dyspnoea SR/MA rule-in specificity (Renier 2018, European Journal of Emergency Medicine — same systematic review / meta-analysis, 8 ED studies, 4,737 patients): specificity was good for elevated jugular venous pressure (0.75–0.97 across studies; pooled specificity 0.88, pooled odds ratio 7, labelled as such), the added third heart sound (specificity 0.97) and lung crepitations (pooled specificity 0.77, pooled odds ratio 11, labelled as such) — labelled slice of synthesis 2 of exactly 2; not an independent source

Study: Labelled slice of synthesis 2 of exactly 2 (acute-dyspnoea SR/MA) — FLOOR-RISK composition

Population: The same 8-study (4,737-patient) acute-dyspnoea systematic review / meta-analysis as the preceding slice. Slice 2 of this synthesis's component findings: specificity of the bedside signs for heart failure.

Summary: FLOOR-RISK slice 2 of the second synthesis — dyspnoea SR/MA rule-in specificity (Renier 2018, European Journal of Emergency Medicine — same systematic review / meta-analysis, 8 ED studies, 4,737 patients): specificity was good for elevated jugular venous pressure (0.75–0.97 across studies; pooled specificity 0.88, pooled odds ratio 7, labelled as such), the added third heart sound (specificity 0.97) and lung crepitations (pooled specificity 0.77, pooled odds ratio 11, labelled as such) — labelled slice of synthesis 2 of exactly 2; not an independent source

Result: Specificity was good for elevated jugular venous pressure (0.75–0.97 across studies) and peripheral oedema (0.67–0.89), moderate for rales (0.31–0.98 across studies). Pooled specificity of most signs ranged between 0.69 and 0.88; the positive likelihood ratio was between 0.64 and 4.11 and the negative likelihood ratio between 0.59 and 1.29, with one outlier (rales, pooled negative LR 0.35) — relative measures, labelled as such. The reviewers conclude elevated jugular venous pressure (pooled specificity 0.88, pooled odds ratio 7), added third heart sound (specificity 0.97) and lung crepitations (pooled specificity 0.77, pooled odds ratio 11) are useful in ruling IN heart failure, as published.

Watch out: Rule-in only: high specificity with pooled sensitivity below 0.55 means these signs confirm far better than they exclude. Odds ratios and likelihood ratios are relative measures and print labelled as such. FLOOR-RISK basis (exact): this shelf rests on exactly 2 overlapping syntheses and no primary report — the Rational Clinical Examination synthesis (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies with complete data, 4,737 patients). The two syntheses overlap in question, population (acute dyspnoea), signs (third heart sound, jugular venous pressure, oedema, rales / crepitations) and — given the small pre-2005 primary literature both draw on — in primary-study scope, although study-level overlap was scoped, not enumerated, from the abstracts. This is the SCOFF / Amsler precedent's composition, and the shelf is built only on that precedent.

Source: Renier et al. Signs and symptoms in adult patients with acute dyspnea: a systematic review and meta-analysis. European journal of emergency medicine : official journal of the European Society for Emergency Medicine. 2018. PMID: 29252938. Registry ID: none in the record. MeSH: Acute Coronary Syndrome/diagnosis · Adult · Asthma/diagnosis · Dyspnea/diagnosis,epidemiology · Emergency Service, Hospital · Heart Failure/diagnosis · Humans · Male · Physical Examination/statistics & numerical data · Pulmonary Disease, Chronic Obstructive/diagnosis

Card 5 — Synthesis (FLOOR-RISK — exactly 2 overlapping syntheses, no primary report): bedside heart-failure signs in acute dyspnoea rule in (S3 positive LR 11 in the RCE; JVP pooled specificity 0.88 / odds ratio 7, S3 specificity 0.97 and crepitations odds ratio 11 in the dyspnoea meta-analysis) and cannot rule out (pooled sensitivities below 0.55)

Study: Synthesis

Population: Synthesis of exactly the 2 overlapping syntheses carded above — the Rational Clinical Examination (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies, 4,737 patients) — presented as 4 labelled slices (2 per synthesis) plus this Synthesis card. No primary report is carded and no third source exists on this shelf.

Summary: Synthesis (FLOOR-RISK — exactly 2 overlapping syntheses, no primary report): bedside heart-failure signs in acute dyspnoea rule in (S3 positive LR 11 in the RCE; JVP pooled specificity 0.88 / odds ratio 7, S3 specificity 0.97 and crepitations odds ratio 11 in the dyspnoea meta-analysis) and cannot rule out (pooled sensitivities below 0.55)

Result: Both syntheses agree: the third heart sound is the strongest rule-in examination sign (RCE positive likelihood ratio 11, 95% CI 4.9 to 25.0; dyspnoea meta-analysis specificity 0.97), elevated jugular venous pressure rules in (pooled specificity 0.88, pooled odds ratio 7 — relative measures labelled as such) with crepitations / rales also specific (pooled specificity 0.77, pooled odds ratio 11), while sensitivity fails throughout (pooled sensitivities below 0.55; JVP 0.19–0.70, oedema 0.29–0.77, rales 0.32–0.88 across studies) and the RCE's best examination rule-out (absence of rales) reaches only negative LR 0.51. Conclusion printed by both syntheses and adopted here: no single sign can rule heart failure out in acute dyspnoea.

Watch out: FLOOR-RISK basis (exact): this shelf rests on exactly 2 overlapping syntheses and no primary report — the Rational Clinical Examination synthesis (PMID 16234501, 22 studies) and the acute-dyspnoea signs systematic review / meta-analysis (PMID 29252938, 8 ED studies with complete data, 4,737 patients). The two syntheses overlap in question, population (acute dyspnoea), signs (third heart sound, jugular venous pressure, oedema, rales / crepitations) and — given the small pre-2005 primary literature both draw on — in primary-study scope, although study-level overlap was scoped, not enumerated, from the abstracts. This is the SCOFF / Amsler precedent's composition, and the shelf is built only on that precedent. Study-level overlap between the two syntheses was scoped, not enumerated, from the abstracts — stated here, on the balance, on the stamp and on every card of this shelf, exactly as the row directs.

Source: Synthesis of the reports carded above; no additional source.