SourceMed · Shelf #8072 in the ask interface

Neuropathic Pain Questionnaire (NPQ) and NPQ-SF accuracy — NO derivation card (the original derivation was not returned by any search form; this pack stands on validations): 5 reports, a short form that spreads from AUC 0.76 to 0.94, and 50% sensitivity in spinal cord injury

Shelf #8072 · Brain, stroke & mind

SCREENING ACCURACY — mixed, no derivation card: 5 reports (2 full NPQ + 2 NPQ-SF + 1 multi-tool SCI study); the original NPQ derivation was not returned by any search form and this pack stands on validations, printed as such; full NPQ Persian AUC 0.76 (0.84/0.64 at −0.3) and a Chinese comparison in which the NPQ's AUC was significantly below LANSS/ID Pain with no pair printed; NPQ-SF spread — Arabic AUC 0.76 with alpha 0.45–0.48 vs Polish AUC 0.94 (90.0%/88.0%); SCI NPQ sensitivity 50% / specificity 100% (N=40); a screening-accuracy stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2011–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does the Neuropathic Pain Questionnaire family (NPQ — 12 items combined by a discriminant function into a single score; and its 3-item short form, NPQ-SF) distinguish neuropathic from non-neuropathic pain — how did the NPQ and its fellow screeners perform in the Chinese three-questionnaire comparison and in spinal cord injury, and what discriminant ability did the Persian NPQ and the Arabic and Polish short forms find? (5 reports: 2 full NPQ + 2 NPQ-SF + 1 multi-tool study. The original NPQ derivation report was not returned by any search form tried — this pack stands on validations and says so.)

Balance of the evidence

This is a screening-accuracy shelf, not a treatment shelf. Composition printed on the face, exactly: 2 full-NPQ reports + 2 NPQ-SF reports + 1 multi-tool spinal-cord-injury study = 5 reports. NO DERIVATION CARD EXISTS ON THIS SHELF: the original NPQ derivation report (Krause/Backonja line) was not returned by any search form tried at mining or at build, and this pack stands on validations and says so on its title, question, balance, stamp and Synthesis — no derivation figure is printed anywhere, and none was invented. The two forms are different measurements (a 12-item discriminant-function score vs a 3-item subset) and no figure prints without its form. The short form's accuracy spread is the headline: AUC 0.76 with poor internal consistency (alpha 0.45–0.48) in the Arabic validation vs AUC 0.94 (sensitivity 90.0% / specificity 88.0%) in the Polish validation. Discriminant-function scores — including negative cut-offs (−0.3 in the Persian study; ≥0.52 in the Arabic short form, above the original study's recommended ≥0) — print exactly as published and are not symptom counts. Neighbouring screeners are different instruments, cross-pointed in prose: ID Pain (pack #8071), DN4 (pack #7812), painDETECT (pack #7968) and LANSS/S-LANSS (pack #8017); the NPQ also appears as a comparator limb inside pack #8017's Saudi three-questionnaire anchor, which is not carded here.

MeSH: Adult · Aged · China · Female · Humans · Language · Linguistics/statistics & numerical data · Male · Middle Aged · Neuralgia/classification/diagnosis · Pain Measurement · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires · Translations · Neuralgia/diagnosis · Psychometrics · Neuralgia/diagnosis/psychology · Poland · Quality of Life/psychology · Surveys and Questionnaires/standards · Pain Measurement/methods · Chronic Pain/diagnosis/psychology · Constipation/etiology · Neuralgia/diagnosis/etiology/psychology · Pain Measurement/methods/statistics & numerical data · ROC Curve · Regression Analysis · Retrospective Studies · Spinal Cord Injuries/complications/diagnosis/psychology · Sweden/epidemiology · Urinary Bladder Diseases/etiology

Cards (6)

Card 1 — Chinese three-questionnaire comparison — Li 2012 (prospective multicentre study, 140 patients: 70 neuropathic / 70 nociceptive; Chinese versions of LANSS, NPQ and ID Pain): the Chinese LANSS and ID Pain had sensitivity, specificity and predictive values above 80%, with the NPQ's figures lower and its AUC significantly lower than LANSS and ID Pain (P<0.05) — the abstract truncates before printing the NPQ's own sensitivity/specificity pair, and NO NPQ pair is printed from this report; reliability coefficients for all three exceeded 0.7, as published. This report's ID Pain limb is shared with the ID Pain question — carded here for its NPQ limb, printed as shared

Study: Validation/comparison study (prospective, multicentre) — full NPQ report 1 of 2; ID Pain limb shared with pack #8071's question

Population: 140 patients enrolled at 10 pain centres in China (70 with neuropathic pain, 70 with nociceptive pain; high-school degree or above) in a nonrandomised prospective multicentre linguistic-adaptation, validation and comparison study of the Chinese LANSS, NPQ and ID Pain; reliability (Cronbach alpha and Guttman split-half) and validity (sensitivity, specificity, predictive values, ROC/AUC) determined for all three.

Summary: Chinese three-questionnaire comparison — Li 2012 (prospective multicentre study, 140 patients: 70 neuropathic / 70 nociceptive; Chinese versions of LANSS, NPQ and ID Pain): the Chinese LANSS and ID Pain had sensitivity, specificity and predictive values above 80%, with the NPQ's figures lower and its AUC significantly lower than LANSS and ID Pain (P<0.05) — the abstract truncates before printing the NPQ's own sensitivity/specificity pair, and NO NPQ pair is printed from this report; reliability coefficients for all three exceeded 0.7, as published. This report's ID Pain limb is shared with the ID Pain question — carded here for its NPQ limb, printed as shared

Result: Chinese versions of all three questionnaires had good reliability (Cronbach alpha and Guttman split-half coefficients greater than 0.7). Sensitivity, specificity, positive and negative predictive values of the Chinese LANSS and ID Pain were considerably high (above 80%). The area under the ROC curve of the NPQ was significantly lower than those of LANSS and ID Pain (P<0.05); there was no significant difference between the LANSS and ID Pain AUCs. The abstract does not print the NPQ's own sensitivity/specificity pair, and none is carded here.

Watch out: No NPQ pair may be printed from this abstract — it truncates before giving one. The study population (high-school degree or above) limits application to patients with lower educational levels, as the authors state.

Source: Li J et al. Linguistic adaptation, validation and comparison of 3 routinely used neuropathic pain questionnaires. Pain physician. 2012. PMID: 22430656. Registry ID: none in the record. MeSH: Adult · Aged · China · Female · Humans · Language · Linguistics/statistics & numerical data · Male · Middle Aged · Neuralgia/classification/diagnosis · Pain Measurement · Prospective Studies · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires · Translations

Card 2 — Persian full NPQ — Shafiee 2022, NPQ-P (101 patients): alpha 0.81, ICC 0.94, AUC 0.76 (95% CI 0.66 to 0.84); at a total score of −0.3 sensitivity 0.84 and specificity 0.64; correlation with the DN4 was 0.42, as published

Study: Validation study — Persian version, full NPQ report 2 of 2

Population: 101 patients enrolled for translation, cross-cultural adaptation and validation of the Persian Neuropathic Pain Questionnaire (NPQ-P); internal consistency (Cronbach alpha), test–retest reliability (ICC), construct validity against the DN4 questionnaire and discriminant ability (ROC analysis) evaluated.

Summary: Persian full NPQ — Shafiee 2022, NPQ-P (101 patients): alpha 0.81, ICC 0.94, AUC 0.76 (95% CI 0.66 to 0.84); at a total score of −0.3 sensitivity 0.84 and specificity 0.64; correlation with the DN4 was 0.42, as published

Result: No modification was needed in translation and cultural adaptation. Cronbach alpha 0.81 and ICC 0.94 supported good reliability. The correlation between NPQ-P and DN4 was 0.42, indicating moderate construct validity. The NPQ-P demonstrated acceptable discriminant ability (AUC 0.76, 95% CI 0.66–0.84). A total score of −0.3 gave the highest Youden index, with sensitivity 0.84 and specificity 0.64, as published. The authors position the NPQ-P as a quick screening adjunct to physical examination and electrodiagnostic tests.

Watch out: A negative cut-off (−0.3) prints exactly as published: the NPQ total is a discriminant-function score, not a symptom count, and a negative threshold is a property of that scoring, not an error.

Source: Shafiee E et al. Psychometric properties of the Persian version of the neuropathic pain questionnaire. Disability and rehabilitation. 2022. PMID: 34498996. Registry ID: none in the record. MeSH: Humans · Language · Neuralgia/diagnosis · Psychometrics · Reproducibility of Results · Surveys and Questionnaires

Card 3 — Arabic NPQ-SF — Terkawi 2017 (142 chronic-pain patients at two tertiary centres): AUC 0.76 (95% CI 0.67 to 0.84), ICC 0.78, but internal consistency was poor (alpha 0.45–0.48), and the best cut-off (≥0.52, sensitivity and specificity both 71%) sat above the original study's recommended ≥0, as published

Study: Validation study — Arabic version, NPQ-SF report 1 of 2 (record carries no MeSH; source line says so)

Population: 142 subjects (68 men, 74 women) with chronic pain at two tertiary care centres, in the development and validation of the Arabic Neuropathic Pain Questionnaire-Short Form (the 3-item short form); reliability by internal consistency, test–retest and ICC; validity against the numeric pain scale, Brief Pain Inventory and S-LANSS; responsiveness assessed by repeat administration.

Summary: Arabic NPQ-SF — Terkawi 2017 (142 chronic-pain patients at two tertiary centres): AUC 0.76 (95% CI 0.67 to 0.84), ICC 0.78, but internal consistency was poor (alpha 0.45–0.48), and the best cut-off (≥0.52, sensitivity and specificity both 71%) sat above the original study's recommended ≥0, as published

Result: Cronbach alpha was 0.45 (95% CI 0.29 to 0.61) and 0.48 (95% CI 0.33 to 0.63) — poor internal consistency, printed as such — and the ICC was 0.78 (95% CI 0.72 to 0.85). The Arabic NPQ-SF was moderately to strongly associated with S-LANSS. Diagnostic accuracy was good by AUC (0.76, 95% CI 0.67 to 0.84), and ROC analysis identified ≥0.52 as the best cut-off to distinguish neuropathic from non-neuropathic pain — higher than the original study's recommended ≥0 — with sensitivity and specificity both 71%, as published. Most patients found the questionnaire clear and easy to understand.

Watch out: Poor internal consistency (alpha 0.45–0.48) prints beside this form's AUC — a 3-item discriminant subset can discriminate groups while cohering poorly as a scale, and both facts belong on the face.

Source: Terkawi AS et al. Development and validation of Arabic version of the Neuropathic Pain Questionnaire-Short Form. Saudi journal of anaesthesia. 2017. PMID: 28616004. Registry ID: none in the record. MeSH: none in the record

Card 4 — Polish NPQ-SF — Szewczyk 2025, NPQ-SF-PL (140 chronic-pain patients: 90 neuropathic / 50 non-neuropathic): AUC 0.94, sensitivity 90.0% and specificity 88.0%, alpha 0.76, ICC 0.631, as published — the strongest short-form figures on this shelf, against the Arabic form's AUC 0.76 with alpha 0.45–0.48

Study: Validation study — Polish version, NPQ-SF report 2 of 2

Population: 140 patients with chronic pain (90 with neuropathic pain, 50 with non-neuropathic pain; mean age 53.22 years; women predominated) in the translation, cultural adaptation and validation of the Polish NPQ-SF; reliability by internal consistency and ICC, validity by ROC analysis and comparison with S-LANSS and the Numerical Rating Scale, with SF-36 quality of life and depression screening also reported.

Summary: Polish NPQ-SF — Szewczyk 2025, NPQ-SF-PL (140 chronic-pain patients: 90 neuropathic / 50 non-neuropathic): AUC 0.94, sensitivity 90.0% and specificity 88.0%, alpha 0.76, ICC 0.631, as published — the strongest short-form figures on this shelf, against the Arabic form's AUC 0.76 with alpha 0.45–0.48

Result: Cronbach alpha for the entire scale was 0.76 and ICC for test–retest reliability was 0.631 (moderate reliability, as printed). ROC analysis gave sensitivity 90.0%, specificity 88.0% and area under the curve 0.94. The NPQ-SF-PL was moderately associated with S-LANSS and weakly with the Numerical Rating Scale. The authors conclude the Polish version is a valid screening tool with very good psychometric properties, as published.

Watch out: The short-form spread is the headline and prints unsmoothed: Polish AUC 0.94 vs Arabic AUC 0.76 — same 3-item form, different language versions and spectra; neither figure may be quoted as 'the NPQ-SF's accuracy' without its version.

Source: Szewczyk AK et al. Validation analysis of Polish version of Neuropathic Pain Questionnaire - Short Form (NPQ-SF-PL) and assessment of quality of life in patients with chronic neuropathic pain. Neurologia i neurochirurgia polska. 2025. PMID: 39530324. Registry ID: none in the record. MeSH: Humans · Female · Male · Neuralgia/diagnosis/psychology · Middle Aged · Poland · Quality of Life/psychology · Surveys and Questionnaires/standards · Reproducibility of Results · Psychometrics · Adult · Pain Measurement/methods · Chronic Pain/diagnosis/psychology · Aged

Card 5 — Spinal cord injury multi-tool study — Hallström 2011 (40 individuals with SCI and pain ≥6 months, assessed twice against specialised-physician classification; SMALL N prints on the face): the NPQ's sensitivity was 50% and specificity 100%, diagnostic accuracy 65%, with test–retest kappa within the 0.70–1.00 range shared by DN4/LANSS/NPQ, as published — the DN4, LANSS and painDETECT figures inside this study print as comparators only

Study: Multi-tool screening study in spinal cord injury — N=40, small N on the face

Population: 40 individuals with spinal cord injury ≥1 year and pain ≥6 months, examined by a specialised physician and assessed twice with four screening tools (DN4, LANSS, NPQ and painDETECT); reliability (test–retest) and validity (sensitivity, specificity, overall agreement) calculated against the physician classification, with an explorative cut-off analysis.

Summary: Spinal cord injury multi-tool study — Hallström 2011 (40 individuals with SCI and pain ≥6 months, assessed twice against specialised-physician classification; SMALL N prints on the face): the NPQ's sensitivity was 50% and specificity 100%, diagnostic accuracy 65%, with test–retest kappa within the 0.70–1.00 range shared by DN4/LANSS/NPQ, as published — the DN4, LANSS and painDETECT figures inside this study print as comparators only

Result: Reliability was good to very good for DN4, LANSS and NPQ (Cohen kappa 0.70–1.00). Comparator figures, printed as comparators: DN4 sensitivity 93%, painDETECT 68%, NPQ 50%, LANSS 36%; specificity LANSS and NPQ 100%, painDETECT 83%, DN4 75%; diagnostic accuracy DN4 88%, painDETECT 78%, NPQ 65%, LANSS 55%. A final model found hypoesthesia to touch, burning pain and numbness discriminated pain type in this cohort, as published.

Watch out: Small N (40) and a specialised SCI population: the NPQ's 50% sensitivity here is the weakest in its own comparison and prints as such — half of physician-classified neuropathic pain in SCI screened negative on the NPQ.

Source: Hallström H et al. Screening tools for neuropathic pain: can they be of use in individuals with spinal cord injury?. Pain. 2011. PMID: 21272997. Registry ID: none in the record. MeSH: Adult · Aged · Constipation/etiology · Female · Humans · Male · Middle Aged · Neuralgia/diagnosis/etiology/psychology · Pain Measurement/methods/statistics & numerical data · ROC Curve · Regression Analysis · Reproducibility of Results · Retrospective Studies · Spinal Cord Injuries/complications/diagnosis/psychology · Surveys and Questionnaires · Sweden/epidemiology · Urinary Bladder Diseases/etiology

Card 6 — Synthesis — 5 reports (2 full NPQ + 2 NPQ-SF + 1 multi-tool SCI study) and NO derivation card: the original NPQ derivation was not returned by any search form tried, so this pack stands on validations and says so; the short form's spread (Arabic AUC 0.76, alpha 0.45–0.48 vs Polish AUC 0.94) is the headline, and the NPQ's SCI sensitivity was 50%

Study: Synthesis

Population: Synthesis of the 5 reports carded above (140 + 101 + 142 + 140 + 40 participants). NO DERIVATION: the original Neuropathic Pain Questionnaire derivation report was not returned by this desk's searches under any form tried — it is not carded, no derivation figure is printed anywhere on this shelf, and the pack's evidence base is validations and comparisons only, stated here, in the title, question, balance and stamp. Cross-points in prose only: ID Pain (pack #8071), DN4 (pack #7812), painDETECT (pack #7968) and LANSS/S-LANSS (pack #8017) are different screeners; the Chinese comparison carded above is shared with the ID Pain question for its ID Pain limb, printed as shared on its card.

Summary: Synthesis — 5 reports (2 full NPQ + 2 NPQ-SF + 1 multi-tool SCI study) and NO derivation card: the original NPQ derivation was not returned by any search form tried, so this pack stands on validations and says so; the short form's spread (Arabic AUC 0.76, alpha 0.45–0.48 vs Polish AUC 0.94) is the headline, and the NPQ's SCI sensitivity was 50%

Result: Read together: the full NPQ discriminates moderately where it has been validated (Persian AUC 0.76, 0.84/0.64 at a discriminant cut-off of −0.3; in the Chinese comparison its AUC was significantly below LANSS and ID Pain, with no pair printed in that abstract and none printed here), and the 3-item short form is unstable across versions (Arabic AUC 0.76 with poor internal consistency; Polish AUC 0.94 with 90.0%/88.0%). In spinal cord injury the NPQ was perfectly specific but missed half of neuropathic pain (sensitivity 50%, N=40). No single accuracy figure describes 'the NPQ' — form, language version and population move the result, and every figure on this shelf prints with all three.

Watch out: A screening-accuracy synthesis, not a treatment claim. Derivation absence is a fact of this pack, printed on the face — it is not filled by inference from the validations, and no card presents a validation as the derivation.