SourceMed · Shelf #8077 in the ask interface

Epworth Sleepiness Scale: a reliable subjective-sleepiness measure (pooled α ≈ 0.82) that is not an apnoea test — OSA sensitivity 0.48 in its own meta-analysis — 4 reports

Shelf #8077 · Lungs, breathing & sleep

MEASUREMENT PROPERTIES — subjective sleepiness measured reliably at group level, apnoea detection NOT ESTABLISHED: internal consistency α 0.73–0.86 in the systematic review and pooled α ≈ 0.82 in the reliability-generalisation meta-analysis, but correlations with objective sleepiness and apnoea indices are weak, and OSA sensitivity was 0.48 (specificity 0.73) in the questionnaire meta-analysis — the weakest sensitivity of the questionnaires compared; composition 1 primary report + 3 syntheses; a measurement stamp, not an apnoea-screening or treatment stamp

Stamped: 2026-11-28.

Evidence published: 1991–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What does the Epworth Sleepiness Scale (ESS — eight everyday situations rated 0–3 for the chance of dozing, total 0–24) actually measure, and how well — what did its derivation establish against sleep-latency testing and sleep-study indices, what does the systematic review of its measurement properties conclude, what pooled internal consistency does the reliability-generalisation meta-analysis give, and how accurately does the ESS detect obstructive sleep apnoea in the comprehensive questionnaire meta-analysis?

Balance of the evidence

This shelf rests on 1 primary report + 3 syntheses, and that composition prints. The ESS was never homed before: it lived only as a comparator limb inside the Berlin and STOP-Bang syntheses, and comparator limbs in those packs (#7854, #7578) are NOT carded here. The two measurement syntheses tell one consistent story — adequate internal consistency, weak correlations with objective sleepiness and with apnoea indices — and that is the headline: a high ESS is a subjective-sleepiness measure, not an apnoea test; its OSA sensitivity (0.48) is the weakest of the questionnaires in its own meta-analysis, whose Berlin and STOP-Bang figures print as comparators only. The derivation report is programme-labelled (the Johns group's own report) and its abstract reports the correlations qualitatively — no correlation coefficient may be printed from it. The syntheses overlap in the literature they draw on and are counted as syntheses, never as independent confirmations. Cross-points in prose: the insomnia instruments shelf (#7967, ISI / PSQI) measures a different construct, and the Berlin (#7854) and STOP-Bang (#7578) shelves are apnoea-screening questions in their own right.

MeSH: Adult · Arousal · Circadian Rhythm · Disorders of Excessive Somnolence/diagnosis,psychology · Female · Humans · Male · Middle Aged · Narcolepsy/diagnosis,psychology · Psychometrics · Restless Legs Syndrome/diagnosis,psychology · Sleep Apnea Syndromes/diagnosis,psychology · Sleep Initiation and Maintenance Disorders/diagnosis,psychology · Sleep Wake Disorders/diagnosis,psychology · Snoring · Wakefulness · Checklist · Disorders of Excessive Somnolence/diagnosis · Reproducibility of Results · Surveys and Questionnaires · Sleepiness · Sleep Apnea, Obstructive/diagnosis · Mass Screening · Sensitivity and Specificity · Polysomnography

Cards (5)

Card 1 — Derivation (Johns 1991, Sleep — 180 adults: 30 controls, 150 with sleep disorders): total ESS scores significantly distinguished controls from patients with obstructive sleep apnoea syndrome, narcolepsy and idiopathic hypersomnia, and correlated significantly with sleep latency and, in OSA, with the respiratory disturbance index and minimum SaO2, while simple snorers did not differ from controls — programme-labelled: the Johns group's own report; its abstract reports the correlations qualitatively and no coefficient is printed from it

Study: Derivation (primary report) — programme-labelled

Population: 180 adults answering the ESS: 30 normal men and women as controls and 150 patients with a range of sleep disorders, rating the chance of dozing in eight everyday situations.

Summary: Derivation (Johns 1991, Sleep — 180 adults: 30 controls, 150 with sleep disorders): total ESS scores significantly distinguished controls from patients with obstructive sleep apnoea syndrome, narcolepsy and idiopathic hypersomnia, and correlated significantly with sleep latency and, in OSA, with the respiratory disturbance index and minimum SaO2, while simple snorers did not differ from controls — programme-labelled: the Johns group's own report; its abstract reports the correlations qualitatively and no coefficient is printed from it

Result: Total ESS scores significantly distinguished normal subjects from patients in various diagnostic groups including obstructive sleep apnoea syndrome, narcolepsy and idiopathic hypersomnia. ESS scores were significantly correlated with sleep latency measured during the multiple sleep latency test and during overnight polysomnography. In patients with obstructive sleep apnoea syndrome, ESS scores were significantly correlated with the respiratory disturbance index and the minimum SaO2 recorded overnight. ESS scores of patients who simply snored did not differ from controls, as published — qualitatively, as the abstract reports them; no correlation coefficient is printed from this record.

Watch out: Programme-labelled derivation report (the Johns group's own report). Known-groups separation in a referred sleep-disorders spectrum is not screening accuracy in an unselected population.

Source: Johns et al. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep. 1991. PMID: 1798888. Registry ID: none in the record. MeSH: Adult · Arousal · Circadian Rhythm · Disorders of Excessive Somnolence/diagnosis,psychology · Female · Humans · Male · Middle Aged · Narcolepsy/diagnosis,psychology · Psychometrics · Restless Legs Syndrome/diagnosis,psychology · Sleep Apnea Syndromes/diagnosis,psychology · Sleep Initiation and Maintenance Disorders/diagnosis,psychology · Sleep Wake Disorders/diagnosis,psychology · Snoring · Wakefulness

Card 2 — Measurement-properties systematic review (Kendzerska 2014, Sleep Medicine Reviews — 35 studies appraised with COSMIN, most of fair quality): internal consistency α 0.73–0.86, little test–retest evidence, pooled correlations moderate with the maintenance of wakefulness test (ρ −0.43) and weak with the MSLT (ρ −0.27) and with sleep-apnoea variables (ρ 0.11–0.23); the reviewers conclude the ESS can be recommended for group-level but not individual-level comparisons

Study: Systematic review of measurement properties

Population: 35 studies evaluating the psychometric properties of the ESS in adults (27 construct validity, 14 known-group validity, 8 internal consistency, 4 test–retest reliability); study quality ranged from excellent to poor, the majority fair.

Summary: Measurement-properties systematic review (Kendzerska 2014, Sleep Medicine Reviews — 35 studies appraised with COSMIN, most of fair quality): internal consistency α 0.73–0.86, little test–retest evidence, pooled correlations moderate with the maintenance of wakefulness test (ρ −0.43) and weak with the MSLT (ρ −0.27) and with sleep-apnoea variables (ρ 0.11–0.23); the reviewers conclude the ESS can be recommended for group-level but not individual-level comparisons

Result: Internal consistency by Cronbach's alpha was good (0.73–0.86), with little available evidence on test–retest reliability. Pooled correlations varied from moderate (maintenance of wakefulness test, rho −0.43) to weak (multiple sleep latency test, rho −0.27; sleep apnoea-related variables, rho 0.11 to 0.23). Although ESS scores varied significantly across groups with known differences in daytime sleepiness, not all differences were clinically important. The reviewers conclude the internal consistency suggests the instrument can be recommended for group but not individual-level comparisons, as published.

Watch out: Synthesis card: counted as a synthesis, never as an independent confirmation of the derivation. Group-level recommendation only — an individual patient's ESS is a weaker measurement than the pooled alpha suggests.

Source: Kendzerska et al. Evaluation of the measurement properties of the Epworth sleepiness scale: a systematic review. Sleep medicine reviews. 2014. PMID: 24135493. Registry ID: none in the record. MeSH: Checklist · Disorders of Excessive Somnolence/diagnosis · Humans · Psychometrics · Reproducibility of Results · Surveys and Questionnaires · Wakefulness

Card 3 — Reliability-generalisation meta-analysis (Gonçalves 2023, Sleep Medicine — 46 publications, 63 estimates, 92,503 participants): cumulative Cronbach's α ≈ 0.82 (95% CI 0.798 to 0.832) with very high heterogeneity (I² = 98.96%) that setting and continent only slightly explained

Study: Reliability-generalisation meta-analysis

Population: 46 publications (63 Cronbach's alpha estimates) from psychometric or validation studies of the ESS in clinical and non-clinical groups, 1991 to October 2022, comprising 92,503 participants.

Summary: Reliability-generalisation meta-analysis (Gonçalves 2023, Sleep Medicine — 46 publications, 63 estimates, 92,503 participants): cumulative Cronbach's α ≈ 0.82 (95% CI 0.798 to 0.832) with very high heterogeneity (I² = 98.96%) that setting and continent only slightly explained

Result: Using a random-effects model, the cumulative Cronbach's alpha for the 63 estimates was about 0.82 (95% CI 0.798 to 0.832). Heterogeneity was very high (I² = 98.96%). Moderation analyses considered setting, date, continent, risk of bias, sex, age and language; only study setting and continent were significant, and both had little importance in explaining the heterogeneity, as published.

Watch out: Synthesis card: a pooled alpha across 63 heterogeneous estimates is a literature average, not the reliability in any one clinic population; the near-total heterogeneity (I² = 98.96%) prints beside the pooled figure.

Source: Gonçalves et al. Epworth sleepiness scale: A meta-analytic study on the internal consistency. Sleep medicine. 2023. PMID: 37487279. Registry ID: none in the record. MeSH: Humans · Sleepiness · Reproducibility of Results · Surveys and Questionnaires · Psychometrics · Wakefulness

Card 4 — OSA questionnaire meta-analysis (Li 2024, Sleep & Breathing — 34 studies): the ESS's pooled sensitivity for obstructive sleep apnoea syndrome was 0.48 with specificity 0.73, against the Berlin questionnaire's 0.80 / 0.48 and STOP-Bang's 0.89 / 0.40 in the same analysis — provenance printed: this synthesis was sighted at Slate 23, fetched at Slate 24 for the Berlin row and explicitly not carded there; its ESS limb is carded here for the ESS's own question

Study: Comprehensive meta-analysis of OSA screening questionnaires

Population: 34 studies in a comprehensive review and meta-analysis of observational studies evaluating the diagnostic utility of obstructive sleep apnoea screening questionnaires, with subgroup analyses by OSA severity.

Summary: OSA questionnaire meta-analysis (Li 2024, Sleep & Breathing — 34 studies): the ESS's pooled sensitivity for obstructive sleep apnoea syndrome was 0.48 with specificity 0.73, against the Berlin questionnaire's 0.80 / 0.48 and STOP-Bang's 0.89 / 0.40 in the same analysis — provenance printed: this synthesis was sighted at Slate 23, fetched at Slate 24 for the Berlin row and explicitly not carded there; its ESS limb is carded here for the ESS's own question

Result: The Berlin questionnaire had a sensitivity of 0.80 and a specificity of 0.48, while the Epworth Sleepiness Scale had a sensitivity of 0.48 and a specificity of 0.73. The STOP-Bang scale had a sensitivity and specificity of 0.89 and 0.40 respectively. The authors propose the STOP questionnaire as an easy-to-use screening tool and note the ESS had higher specificity, as published. The ESS's sensitivity (0.48) is the weakest of the questionnaires compared in this analysis.

Watch out: Synthesis card: the Berlin and STOP-Bang pairs inside this analysis are comparators — their home shelves are #7854 and #7578, and no Berlin or STOP-Bang claim is carded here. A sensitivity of 0.48 means the ESS misses about half of OSA in this pooled literature: it is not an apnoea test.

Source: Li et al. Diagnostic utility of obstructive sleep apnea screening questionnaires: a comprehensive meta-analysis. Sleep & breathing = Schlaf & Atmung. 2024. PMID: 39601864. Registry ID: none in the record. MeSH: Sleep Apnea, Obstructive/diagnosis · Humans · Surveys and Questionnaires · Mass Screening · Sensitivity and Specificity · Polysomnography · Psychometrics

Card 5 — Synthesis (1 primary report + 3 syntheses): the ESS reliably measures subjective daytime sleepiness at group level — and is not an apnoea test (OSA sensitivity 0.48, the weakest in its own meta-analysis)

Study: Synthesis

Population: Synthesis of the 4 reports carded above (derivation n = 180; measurement-properties review of 35 studies; reliability-generalisation meta-analysis of 46 publications / 92,503 participants; OSA questionnaire meta-analysis of 34 studies). The three syntheses overlap in the literature they draw on and are counted as syntheses, never as independent confirmations.

Summary: Synthesis (1 primary report + 3 syntheses): the ESS reliably measures subjective daytime sleepiness at group level — and is not an apnoea test (OSA sensitivity 0.48, the weakest in its own meta-analysis)

Result: The derivation separated sleep-disorder groups from controls qualitatively. The measurement syntheses converge: internal consistency is adequate (α 0.73–0.86; pooled ≈ 0.82, with I² = 98.96% heterogeneity), while correlations with objective sleepiness (MWT ρ −0.43; MSLT ρ −0.27) and apnoea variables (ρ 0.11–0.23) are weak to moderate, supporting group-level but not individual-level use. As an apnoea screen the ESS pooled at sensitivity 0.48 / specificity 0.73 — the weakest sensitivity among the questionnaires compared (Berlin 0.80 / 0.48; STOP-Bang 0.89 / 0.40, comparators only).

Watch out: A high ESS states subjective sleepiness; it neither diagnoses nor excludes obstructive sleep apnoea. No individual-level clinical decision may rest on the pooled alpha.

Source: Synthesis of the reports carded above; no additional source.