SourceMed · Shelf #8081 in the ask interface

PRISMA-7: seven-item frailty case-finding at ≥3 — ED pooled figures are family-level, German / Chinese / Turkish validations rest on different reference standards — 4 reports

Shelf #8081 · Geriatrics, frailty & deprescribing

SCREENING ACCURACY — PRISMA-7-specific pooled accuracy NOT ESTABLISHED: the ED synthesis's pooled pair (sensitivity 0.85, specificity 0.77, AUC 0.89) is a seven-instrument family figure, not PRISMA-7's own; single-study pairs print with their reference standards (Chinese: sensitivity 100%, specificity 85.3% at ≥3 against functional autonomy, n = 120 bilingual convenience sample; Turkish: AUC 0.903, sensitivity 81.5% / specificity 88.2% at ≥4 against the Clinical Frailty Scale screener, n = 150; German: AUC >0.90 vs a 4%-prevalence phenotype, n = 52, shared report); composition 4 reports including 1 shared report printed as shared; a screening-accuracy stamp, not a frailty-treatment stamp

Stamped: 2026-11-28.

Evidence published: 2018–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does PRISMA-7 (a seven-item yes/no frailty case-finding questionnaire from the PRISMA programme — age, sex, health problems limiting activities, help needs, staying home, social support and walking-aid use; positive at ≥3) identify frailty — what pooled accuracy do emergency-department frailty screens achieve in the systematic review / meta-analysis, how did the German version perform against the Fried phenotype and the Frailty Index, and what did the Chinese and Turkish validations find?

Balance of the evidence

This is a screening-accuracy shelf. The reference standards are four different things — comprehensive diagnostic standards in the ED synthesis, the Fried phenotype / Frailty Index in the German study, the SMAF functional-autonomy system in the Chinese study, and the Clinical Frailty Scale (another screener) in the Turkish study — and every figure prints with its standard: agreement with the CFS is not accuracy against frailty. The ED synthesis's pooled pair is family-level (seven instruments, 13 data points, too few studies for instrument-level meta-analysis) and may not be headlined as PRISMA-7's performance. Two of PRISMA-7's seven items are age and sex, so part of its 'accuracy' is demographic — a design fact that prints. The German study (PMID 28795247) is a SHARED report by row direction: its PRISMA-7 limb is carded here as a printed shared limb with its composition stated, and its GFI limb is carded on the GFI shelf (#8079) — the sharing is directed, not an error to fix. The CFS itself is homed at #7506 / #7916; its appearance inside the Turkish study is a reference-standard (comparator) role. Cross-points in prose: the neighbouring EFS (#8078), GFI (#8079) and TFI (#8080) shelves are different frailty instruments.

MeSH: Humans · Female · Aged · Aged, 80 and over · Frailty/diagnosis,epidemiology · Prospective Studies · Risk Assessment · Geriatric Assessment · Emergency Service, Hospital · Cross-Cultural Comparison · Cross-Sectional Studies · Frail Elderly/statistics & numerical data · Geriatric Assessment/statistics & numerical data · Germany · Male · Mass Screening/statistics & numerical data · Outcome Assessment, Health Care/statistics & numerical data · Phenotype · Psychometrics/statistics & numerical data · Reproducibility of Results · Surveys and Questionnaires · Translating · China · Frailty/diagnosis · Psychometrics/methods

Cards (5)

Card 1 — ED frailty-screen synthesis (Moloney 2023, International Journal of Environmental Research and Public Health — 6 studies, 1,663 participants, seven instruments including PRISMA-7 as 13 data points against diagnostic standards): pooled sensitivity across instruments was 0.85 (95% CI 0.76 to 0.91) and specificity 0.77 (0.62 to 0.88), AUC 0.89, at a pooled frailty prevalence of 59%, with too few studies for instrument-level meta-analysis — labelled a multi-instrument synthesis: its pooled pair is the family figure, not PRISMA-7's own, and no PRISMA-7-specific pooled pair is printed from it

Study: Systematic review and meta-analysis — multi-instrument synthesis, labelled

Population: 6 prospective diagnostic-accuracy studies involving 1,663 older adults attending emergency departments (mean age 76 to 86 years, 45–60% female), describing seven frailty screening instruments (PRISMA-7, CFS, VIP, FRESH, BPQ, TRST and ISAR) as 13 unique data points, validated against diagnostic standards such as comprehensive geriatric assessment; risk of bias assessed with QUADAS-C.

Summary: ED frailty-screen synthesis (Moloney 2023, International Journal of Environmental Research and Public Health — 6 studies, 1,663 participants, seven instruments including PRISMA-7 as 13 data points against diagnostic standards): pooled sensitivity across instruments was 0.85 (95% CI 0.76 to 0.91) and specificity 0.77 (0.62 to 0.88), AUC 0.89, at a pooled frailty prevalence of 59%, with too few studies for instrument-level meta-analysis — labelled a multi-instrument synthesis: its pooled pair is the family figure, not PRISMA-7's own, and no PRISMA-7-specific pooled pair is printed from it

Result: The pooled prevalence of frailty was 59%. The pooled estimate for sensitivity was 0.85 (95% CI 0.76–0.91) versus 0.77 (95% CI 0.62–0.88) for specificity. Pooled accuracy based on the area under the ROC curve was 0.89 (95% CI 0.86–0.90). The reviewers note few studies were found, limiting the ability to conduct a meta-analysis of individual instruments, and that as specificity was comparatively low, additional assessment may be required, as published.

Watch out: Family figure, not PRISMA-7's own performance: seven instruments pooled. The ED spectrum (59% frailty prevalence) inflates accuracy against community spectra. The CFS inside this synthesis is one of the pooled instruments — a comparator role, not its home shelf's data.

Source: Moloney et al. Diagnostic Accuracy of Frailty Screening Instruments Validated for Use among Older Adults Attending Emergency Departments: A Systematic Review and Meta-Analysis. International journal of environmental research and public health. 2023. PMID: 37444127. Registry ID: none in the record. MeSH: Humans · Female · Aged · Aged, 80 and over · Frailty/diagnosis,epidemiology · Prospective Studies · Risk Assessment · Geriatric Assessment · Emergency Service, Hospital

Card 2 — German three-screener accuracy study — PRISMA-7 limb (Braun 2018, Zeitschrift für Gerontologie und Geriatrie — 52 older participants; SHARED report by row direction: this study's GFI limb is carded on the GFI shelf #8079 and its FRAIL-scale limb belongs to neither shelf's count): PRISMA-7's German version was produced and tested in the same design — AUC >0.90 against the Fried phenotype (4% prevalence) and within 0.73–0.88 against the Frailty Index — small N (52) prints

Study: Diagnostic-accuracy study of three screeners (primary report) — SHARED report, printed as shared; small N prints

Population: 52 older participants (mean age 73 ± 6 years) completing German translations of PRISMA-7, the FRAIL scale and the GFI; reference standards were Fried's Physical Frailty Phenotype and a deficit-accumulation Frailty Index. This card reports the study for its PRISMA-7 limb; the composition is stated here because the report is shared by row direction.

Summary: German three-screener accuracy study — PRISMA-7 limb (Braun 2018, Zeitschrift für Gerontologie und Geriatrie — 52 older participants; SHARED report by row direction: this study's GFI limb is carded on the GFI shelf #8079 and its FRAIL-scale limb belongs to neither shelf's count): PRISMA-7's German version was produced and tested in the same design — AUC >0.90 against the Fried phenotype (4% prevalence) and within 0.73–0.88 against the Frailty Index — small N (52) prints

Result: Prefinal German versions of each instrument were produced and minor comprehensibility and semantics issues were resolved. Using the Physical Frailty Phenotype (frailty prevalence 4%) as the reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence 23%) as the reference standard, accuracy was good (AUC between 0.73 and 0.88). The authors describe these as preliminary results indicating sufficient diagnostic test accuracy that needs to be further established, as published. The abstract reports the three instruments' AUC ranges jointly; no PRISMA-7-only AUC is printed from it.

Watch out: SHARED report, printed as shared by row direction — PRISMA-7 limb here, GFI limb on #8079; never counted twice. Small N (52) with a 4%-prevalence phenotype reference (about 2 frail participants by that reference): the >0.90 AUCs are fragile spectrum figures.

Source: Braun et al. German translation, cross-cultural adaptation and diagnostic test accuracy of three frailty screening tools : PRISMA-7, FRAIL scale and Groningen Frailty Indicator. Zeitschrift fur Gerontologie und Geriatrie. 2018. PMID: 28795247. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cross-Cultural Comparison · Cross-Sectional Studies · Female · Frail Elderly/statistics & numerical data · Geriatric Assessment/statistics & numerical data · Germany · Humans · Male · Mass Screening/statistics & numerical data · Outcome Assessment, Health Care/statistics & numerical data · Phenotype · Psychometrics/statistics & numerical data · Reproducibility of Results · Surveys and Questionnaires · Translating

Card 3 — Chinese validation (Yeung 2024, BMC Geriatrics — 120 bilingual community adults aged ≥65 against the Functional Autonomy Measurement System, SMAF): intra- and inter-rater ICC 1.000, criterion correlations ≈ −0.65, and at the optimal cut-off of ≥3 sensitivity was 100% and specificity 85.3% — small, bilingual convenience sample prints on the face; a perfect sensitivity on this spectrum is a derivation-spectrum figure

Study: Cross-cultural validation (primary report) — small bilingual convenience sample prints

Population: 120 bilingual community-dwelling adults aged 65 and over (55 female, 65 male) recruited by convenience sampling; the Functional Autonomy Measurement System (SMAF) was the reference benchmark; the Chinese version was produced by forward and backward translation.

Summary: Chinese validation (Yeung 2024, BMC Geriatrics — 120 bilingual community adults aged ≥65 against the Functional Autonomy Measurement System, SMAF): intra- and inter-rater ICC 1.000, criterion correlations ≈ −0.65, and at the optimal cut-off of ≥3 sensitivity was 100% and specificity 85.3% — small, bilingual convenience sample prints on the face; a perfect sensitivity on this spectrum is a derivation-spectrum figure

Result: The Chinese PRISMA-7 had excellent intra-rater and inter-rater reliability (ICC = 1.000). Criterion validity was established by moderately high correlations between PRISMA-7 and the SMAF (English version r = −0.655, Chinese version r = −0.653, both p<0.001). An optimal cut-off score of three 'Yes' responses was reported with 100% sensitivity and 85.3% specificity, as published.

Watch out: A bilingual convenience sample (n = 120) tested against a functional-autonomy measure, not a frailty diagnosis: 100% sensitivity on this spectrum is a derivation-spectrum figure and may not be carried into clinic populations. An ICC of 1.000 for a yes/no questionnaire largely reflects the items' demographic content (age, sex).

Source: Yeung et al. The Chinese translation and cross-cultural adaptation of PRISMA-7 questionnaire: an observational study to establish the accuracy, reliability and validity. BMC geriatrics. 2024. PMID: 38418958. Registry ID: none in the record. MeSH: Female · Humans · Male · China · Cross-Cultural Comparison · Frailty/diagnosis · Psychometrics/methods · Reproducibility of Results · Surveys and Questionnaires · Prospective Studies

Card 4 — Turkish validation (Yaman 2018, Electronic Physician — 150 community-dwelling elderly in Antalya against the CSHA Clinical Frailty Scale as reference): test–retest r = 0.992 for PRISMA-7, AUC 0.903 against the CFS, internal consistency α 0.714, and at a cut-off of ≥4 sensitivity 81.5% and specificity 88.2% — labelled: its reference standard is another screener (the CFS), not a diagnostic assessment

Study: Cross-cultural validation (primary report) — reference is another screener, labelled

Population: 150 community-dwelling elderly people in Antalya, Turkey (February 2016 to April 2017), administered Turkish translations of PRISMA-7 and the CSHA Clinical Frailty Scale (piloted in 10 elderly people whose data were not included).

Summary: Turkish validation (Yaman 2018, Electronic Physician — 150 community-dwelling elderly in Antalya against the CSHA Clinical Frailty Scale as reference): test–retest r = 0.992 for PRISMA-7, AUC 0.903 against the CFS, internal consistency α 0.714, and at a cut-off of ≥4 sensitivity 81.5% and specificity 88.2% — labelled: its reference standard is another screener (the CFS), not a diagnostic assessment

Result: Participants were on average vulnerable to frailty. Test–retest reliability was r = 0.992 for PRISMA-7 (p<0.001) and 0.975 for the CSHA Clinical Frailty Scale. Using the CSHA Clinical Frailty Scale as the reference standard, PRISMA-7's area under the ROC curve was 0.903, with medium internal consistency (Cronbach's alpha = 0.714). A cut-off point of 4 or higher revealed sensitivity of 81.5% and specificity of 88.2% for frailty. The authors recommend PRISMA-7 as a reliable and valid screening instrument, as published.

Watch out: Reference-standard discipline: the CFS is itself a frailty screener (homed at #7506 / #7916), so these figures are agreement with another screener, not accuracy against a diagnostic frailty assessment. Its cut-off here is ≥4, not the programme's ≥3 — cut-offs print with their study.

Source: Yaman et al. The validation of the PRISMA-7 questionnaire in community-dwelling elderly people living in Antalya, Turkey. Electronic physician. 2018. PMID: 30258559. Registry ID: none in the record. MeSH: none in the record

Card 5 — Synthesis (4 reports, including 1 shared report printed as shared): PRISMA-7 case-finding is supported study-by-study against four different reference standards — but no PRISMA-7-specific pooled accuracy exists, and the ED pooled pair is a seven-instrument family figure

Study: Synthesis

Population: Synthesis of the 4 reports carded above (ED synthesis of 6 studies, 1,663 participants; German three-screener study n = 52 — shared with the GFI shelf #8079 for its PRISMA-7 limb only, by row direction; Chinese validation n = 120; Turkish validation n = 150).

Summary: Synthesis (4 reports, including 1 shared report printed as shared): PRISMA-7 case-finding is supported study-by-study against four different reference standards — but no PRISMA-7-specific pooled accuracy exists, and the ED pooled pair is a seven-instrument family figure

Result: Against comprehensive diagnostic standards in the ED, frailty screens pooled at sensitivity 0.85 / specificity 0.77 / AUC 0.89 — a family figure across seven instruments, with too few studies for a PRISMA-7-specific pool. Study-by-study: German AUCs were >0.90 against a 4%-prevalence Fried phenotype and 0.73–0.88 against the Frailty Index (n = 52, shared report); the Chinese version reached sensitivity 100% / specificity 85.3% at ≥3 against functional autonomy in a bilingual convenience sample (n = 120); the Turkish version reached AUC 0.903 with sensitivity 81.5% / specificity 88.2% at ≥4 against the CFS screener (n = 150). Reference standard, spectrum and cut-off differ in every report.

Watch out: Sharing restated: PMID 28795247 is carded on both #8079 (GFI limb) and this shelf (PRISMA-7 limb) by row direction, with its composition stated on both faces — it is one study, never two confirmations. Agreement with the CFS (Turkish study) is not diagnostic accuracy, and two of the seven PRISMA-7 items are age and sex.

Source: Synthesis of the reports carded above; no additional source.