SourceMed · Shelf #8084 in the ask interface

ICIQ-UI SF: severity-and-impact measure validated in four languages (Japanese α 0.78, ICC 0.91); self-diagnostic item κ 0.77 vs urodynamics in one study — 4 validations, no development report carded

Shelf #8084 · Urology & men’s health

MEASUREMENT PROPERTIES — supported across language validations, NOT ESTABLISHED as a diagnostic test: Japanese α 0.78 and total-score test–retest ICC 0.91; Malaysian and Arabic validations qualitative in their abstracts; the unscored self-diagnostic item agreed with urodynamic cause at κ 0.77 in one Slovene study; composition 4 validations (no development report carded) counted as such; a measurement stamp, not a treatment or diagnostic-accuracy stamp

Stamped: 2026-11-28.

Evidence published: 2006–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the ICIQ-UI SF (International Consultation on Incontinence Questionnaire — Urinary Incontinence Short Form: three scored items on frequency, amount and impact of leakage, plus an unscored self-diagnostic item on when leakage occurs) — what validity, reliability and responsiveness did the Malaysian, Japanese and Arabic validations establish, and can its self-diagnostic item identify the type of incontinence against urodynamic diagnosis?

Balance of the evidence

Composition prints: 4 validation reports (Malaysian, Japanese, Arabic, Slovene). The original ICIQ-UI SF development report was not returned by the mining desk's searches under the forms tried and is not carded — this shelf stands on four validations, printed as such. A measurement-properties shelf, not an incontinence-treatment shelf. The scored total measures severity-and-impact, not diagnosis — the one diagnostic claim (the unscored self-diagnostic / perceived-cause item vs urodynamic diagnosis, κ 0.77 in the Slovene study) prints as a single-study finding about perceived cause, not as a diagnostic accuracy pair. Language versions print with every coefficient. The Malaysian study's healthy-volunteer contrast (145 healthy volunteers vs 139 stress-incontinence patients) inflates discriminant validity against a clinic spectrum and prints as its design. The Arabic report (programme-labelled: the ICIQ group's own report) reports its properties qualitatively in its abstract and no coefficient may be printed from it beyond what is stated. Cross-points in prose only: pack #8005 (IPSS — male lower-urinary-tract symptoms, a different instrument and population) and the continence ring — UDI-6 / IIQ-7 (#8085), KHQ (#8086, which appears inside the Japanese anchor here as a comparator battery, its correlations printing as comparators, not as KHQ validation), OAB-q (#8087), voiding diary (#8088) and pad-weighing test (#8089).

MeSH: Adult · Aged · Female · Humans · Malaysia · Middle Aged · Pilot Projects · Quality of Life · Reproducibility of Results · Surveys and Questionnaires · Translations · Urinary Incontinence/diagnosis · International Cooperation · Japan · Male · Sampling Studies · Sensitivity and Specificity · Severity of Illness Index · Sickness Impact Profile · Urinary Incontinence/diagnosis,psychology · Urodynamics · Language · Diagnostic Techniques, Urological · Predictive Value of Tests · Risk Factors · Slovenia · Urinary Incontinence/diagnosis,etiology,physiopathology,psychology

Cards (5)

Card 1 — Malaysian validation (Lim 2017, Neurourology and Urodynamics — English, Chinese and Malay versions; 284 participants: 139 stress-incontinence patients, 145 healthy volunteers): good discriminant validity, moderate internal consistency for the ICIQ-UI SF, high test–retest reliability and moderate-to-large responsiveness — reported qualitatively in its abstract for the ICIQ-UI SF, with no coefficient printed from it beyond what is stated

Study: Validation study (primary report) — ICIQ-UI SF properties reported qualitatively in its abstract

Population: 284 participants in Malaysia (139 female patients with stress urinary incontinence and 145 healthy volunteers); the English version was translated into Malay and the existing Chinese version validated; 10 patients were recruited for pilot testing; validity (content and discriminant), reliability (internal consistency, test–retest) and responsiveness (effect size, standardised response mean) were evaluated for the ICIQ-UI SF and the ICIQ-LUTSqol.

Summary: Malaysian validation (Lim 2017, Neurourology and Urodynamics — English, Chinese and Malay versions; 284 participants: 139 stress-incontinence patients, 145 healthy volunteers): good discriminant validity, moderate internal consistency for the ICIQ-UI SF, high test–retest reliability and moderate-to-large responsiveness — reported qualitatively in its abstract for the ICIQ-UI SF, with no coefficient printed from it beyond what is stated

Result: The English and Chinese versions had 'substantial' or 'almost perfect' agreement as measured by weighted kappa in pilot testing. The ICIQ-UI SF and ICIQ-LUTSqol had good discriminant validity. The ICIQ-UI SF had moderate internal consistency, although the ICIQ-LUTSqol had good internal consistency. Both questionnaires had high test–retest reliability. Responsiveness was established with a moderate-to-large effect size and a standardised response mean, as published.

Watch out: The discriminant contrast is patients vs healthy volunteers — an assembled contrast that inflates discriminant validity against a clinic spectrum, and prints as its design. Figures for the companion ICIQ-LUTSqol are a different instrument's and are not the ICIQ-UI SF's.

Source: Lim et al. Validity, reliability, and responsiveness of the ICIQ-UI SF and ICIQ-LUTSqol in the Malaysian population. Neurourology and urodynamics. 2017. PMID: 26693962. Registry ID: none in the record. MeSH: Adult · Aged · Female · Humans · Malaysia · Middle Aged · Pilot Projects · Quality of Life · Reproducibility of Results · Surveys and Questionnaires · Translations · Urinary Incontinence/diagnosis

Card 2 — Japanese validation (Gotoh 2009, International Journal of Urology — two samples of 180 patients with urinary incontinence): α 0.78, test–retest ICC 0.91 for the total score, moderate-to-high correlations with most King's Health Questionnaire subscales, severity quartiles tracking the 1-hour pad test and daily episode counts, and significant post-treatment score falls correlating with KHQ change

Study: Validation study (primary report)

Population: Two study samples of 180 patients with urinary incontinence, used for a psychometric evaluation of the Japanese version of the ICIQ-UI SF examining reliability, validity and responsiveness to change.

Summary: Japanese validation (Gotoh 2009, International Journal of Urology — two samples of 180 patients with urinary incontinence): α 0.78, test–retest ICC 0.91 for the total score, moderate-to-high correlations with most King's Health Questionnaire subscales, severity quartiles tracking the 1-hour pad test and daily episode counts, and significant post-treatment score falls correlating with KHQ change

Result: Internal consistency was sufficiently high, with a Cronbach's alpha coefficient of 0.78. Test–retest intraclass correlation coefficients were 0.90 for item 3 and 0.91 for the total score (kappa coefficients 0.61 for item 1 and 0.62 for item 2). ICIQ-SF scores were moderately to highly correlated with most King's Health Questionnaire (KHQ) subscales. Severity groups divided in quartiles showed linear trends against the 1-hour pad test and the number of daily incontinence episodes in most scores. Changes in the ICIQ-SF after treatment correlated at more than 0.5 with changes in some KHQ subscale scores, and all items and total scores significantly decreased after treatment, as published.

Watch out: The KHQ correlations here are comparator-battery figures for the ICIQ-UI SF — they are not KHQ validation (the KHQ's own shelf is #8086). Severity tracking against the 1-hour pad test is concurrent association, not agreement with a leakage quantity.

Source: Gotoh et al. Psychometric validation of the Japanese version of the International Consultation on Incontinence Questionnaire-Short Form. International journal of urology : official journal of the Japanese Urological Association. 2009. PMID: 19207608. Registry ID: none in the record. MeSH: Aged · Female · Humans · International Cooperation · Japan · Male · Middle Aged · Quality of Life · Reproducibility of Results · Sampling Studies · Sensitivity and Specificity · Severity of Illness Index · Sickness Impact Profile · Surveys and Questionnaires · Urinary Incontinence/diagnosis,psychology · Urodynamics

Card 3 — Arabic version development / validation (Hashim 2006, Neurourology and Urodynamics — urology outpatients in two Middle-Eastern countries): the Arabic ICIQ-UI SF was valid, reliable and responsive, confirming the UK-English version's psychometric findings — programme-labelled: the ICIQ group's own report; its abstract reports the properties qualitatively and no coefficient is printed from it beyond what is stated here

Study: Validation study (primary report) — programme-labelled; qualitative only in its abstract

Population: Patients attending urology outpatient clinics in two Middle-Eastern countries; the Arabic version was developed by standard translation and back-translation by native Arabic and English speakers, and its validity, reliability and sensitivity to change were examined.

Summary: Arabic version development / validation (Hashim 2006, Neurourology and Urodynamics — urology outpatients in two Middle-Eastern countries): the Arabic ICIQ-UI SF was valid, reliable and responsive, confirming the UK-English version's psychometric findings — programme-labelled: the ICIQ group's own report; its abstract reports the properties qualitatively and no coefficient is printed from it beyond what is stated here

Result: The Arabic ICIQ-UI SF was found to be valid, reliable and responsive, indicating that the psychometric properties of the questionnaire remained constant throughout the adaptation process; the findings of the psychometric testing confirmed those found for the UK-English ICIQ-UI SF, as published. No coefficient is reported in the abstract and none is printed.

Watch out: Programme-labelled originator-group report with qualitative-only abstract findings: 'valid, reliable and responsive' is the developers' summary claim, not a coefficient, and may not be ranked against the numeric validations on this shelf.

Source: Hashim et al. The Arabic ICIQ-UI SF: an alternative language version of the English ICIQ-UI SF. Neurourology and urodynamics. 2006. PMID: 16532458. Registry ID: none in the record. MeSH: Humans · Language · Quality of Life · Surveys and Questionnaires · Urinary Incontinence/diagnosis

Card 4 — Slovene validation with urodynamic substudy (Rotar 2009, Neurourology and Urodynamics — urology / gynaecology outpatients, elderly institutionalised patients and a community sample; one group urodynamically tested): excellent test–retest reliability, good internal consistency and responsiveness, and the perceived-cause (self-diagnostic) item agreed with the urodynamically proven cause of incontinence at κ 0.77

Study: Validation study with urodynamic substudy (primary report)

Population: Attendants of urology and gynaecology outpatient clinics, elderly institutionalised patients and a community sample in Slovenia; the ICIQ-UI Short Form was translated into Slovene and re-validated; one group of patients underwent urodynamic testing, whose results were compared with responses to question six (the self-diagnostic item) using kappa statistics.

Summary: Slovene validation with urodynamic substudy (Rotar 2009, Neurourology and Urodynamics — urology / gynaecology outpatients, elderly institutionalised patients and a community sample; one group urodynamically tested): excellent test–retest reliability, good internal consistency and responsiveness, and the perceived-cause (self-diagnostic) item agreed with the urodynamically proven cause of incontinence at κ 0.77

Result: The Slovene version was found to be valid (excellent test–retest reliability, good internal consistency, good responsiveness to change, and reflected well underlying theories) and correlated well with urodynamic findings. The perceived cause of leakage (question 6) was a good indicator of the objectively proven cause of incontinence (kappa value 0.77), as published.

Watch out: κ 0.77 is agreement between the patient's perceived cause and the urodynamic cause in one study — a single-study finding about an unscored item, not a diagnostic sensitivity / specificity pair for the questionnaire, and not a property of the scored total.

Source: Rotar et al. Correlations between the ICIQ-UI short form and urodynamic diagnosis. Neurourology and urodynamics. 2009. PMID: 19260080. Registry ID: none in the record. MeSH: Aged · Diagnostic Techniques, Urological · Female · Humans · Language · Male · Middle Aged · Predictive Value of Tests · Quality of Life · Reproducibility of Results · Risk Factors · Slovenia · Surveys and Questionnaires · Urinary Incontinence/diagnosis,etiology,physiopathology,psychology · Urodynamics

Card 5 — Synthesis: the ICIQ-UI SF's scored total is a severity-and-impact measure supported by four language validations (α 0.78 and ICC 0.91 in the Japanese report; qualitative validity / reliability / responsiveness in the Malaysian and Arabic reports), and its only diagnostic claim is one study's κ 0.77 for the unscored self-diagnostic item against urodynamics

Study: Synthesis

Population: Synthesis of the 4 validation reports carded above (Malaysian 284 participants; Japanese two samples of 180 patients; Arabic outpatient sample, N not documented in its abstract; Slovene mixed outpatient / institutional / community sample, N not documented in its abstract). The original development report is not carded.

Summary: Synthesis: the ICIQ-UI SF's scored total is a severity-and-impact measure supported by four language validations (α 0.78 and ICC 0.91 in the Japanese report; qualitative validity / reliability / responsiveness in the Malaysian and Arabic reports), and its only diagnostic claim is one study's κ 0.77 for the unscored self-diagnostic item against urodynamics

Result: Across the four validations the instrument was valid, reliable and responsive in each language version, with the numeric limb resting chiefly on the Japanese report (α 0.78; total-score ICC 0.91; moderate-to-high KHQ subscale correlations; post-treatment falls correlating with KHQ change) and the Slovene report (excellent test–retest reliability, good internal consistency and responsiveness). The self-diagnostic item agreed with urodynamic cause at κ 0.77 in the Slovene substudy. No pooled coefficient is printed: coefficients belong to their language versions and samples.

Watch out: Composition discipline: 4 validations, no development report carded. Cross-points in prose only: IPSS (#8005), UDI-6 / IIQ-7 (#8085), KHQ (#8086), OAB-q (#8087), voiding diary (#8088), pad-weighing test (#8089) — different instruments measuring severity, distress, quality of life and leakage by different methods, never merged.

Source: Synthesis of the reports carded above; no additional source.