SourceMed · Shelf #8086 in the ask interface

King's Health Questionnaire: quality-of-life impact measure with domain α 0.47–0.86 across 3 validations — never one instrument-wide coefficient

Shelf #8086 · Urology & men’s health

MEASUREMENT PROPERTIES — domain-dependent: domain / subscale α spans 0.47–0.86 across validations (weakest: personal relationships in males 0.47, severity / coping in females 0.59, Japanese trial data; German subscales 0.76–0.86), never a single instrument-wide coefficient; responsiveness large post-surgery and significant within-trial; composition 3 validations counted as such; a quality-of-life measurement stamp, not a severity, leakage-quantity or treatment stamp

Stamped: 2026-11-28.

Evidence published: 2004–2005.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the King's Health Questionnaire (KHQ — a 21-item condition-specific quality-of-life questionnaire for urinary incontinence, scored across domains including role, physical and social limitations, emotions, sleep/energy and severity measures) — what reliability, validity and responsiveness did the Japanese overactive-bladder, Portuguese post-surgical and German stress-incontinence validations establish?

Balance of the evidence

Composition prints: 3 validation reports (Japanese, Portuguese, German). A quality-of-life measurement shelf, not a symptom-severity or treatment shelf — the KHQ measures impact, not leakage amount, and its figures may not be carded alongside pad-test or diary quantities as if commensurable (cross-points #8088 / #8089). The Japanese anchor's data come from a 12-week randomised tolterodine-vs-oxybutynin trial's participants — labelled a secondary psychometric analysis of treatment-trial data; its responsiveness figures are within-trial changes and print with that provenance. Domain-level α varies (0.47–0.86 across the anchors) and prints by domain, never as a single instrument-wide coefficient: the Japanese report's weaker domains are personal relationships in males (0.47) and severity / coping in females (0.59), against German subscale α 0.76–0.86. The Portuguese study is small (68 women, before and one month after sling surgery) and prints with its N. Cross-points in prose only: ICIQ-UI SF (#8084 — inside whose Japanese anchor the KHQ appears as a comparator battery), UDI-6 / IIQ-7 (#8085), OAB-q (#8087), voiding diary (#8088), pad-weighing test (#8089) and IPSS (#8005).

MeSH: Adult · Aged · Aged, 80 and over · Female · Humans · Japan · Male · Middle Aged · Psychometrics · Reproducibility of Results · Surveys and Questionnaires · Urinary Bladder Diseases/diagnosis · Health Status Indicators · Postoperative Period · Prospective Studies · Prostheses and Implants · Quality of Life · Urinary Incontinence, Stress/surgery · Austria · Language · Psychometrics/standards · Surveys and Questionnaires/standards · Urinary Incontinence, Stress/diagnosis,psychology

Cards (5)

Card 1 — Japanese validation, slice 1 — reliability and validity (Uemura 2004, Neurourology and Urodynamics — secondary psychometric analysis of data from a 12-week randomised tolterodine-vs-oxybutynin trial in overactive bladder with urge incontinence): domain α coefficients generally >0.60, with two weaker domains (personal relationships in males 0.47, severity / coping in females 0.59); convergent, discriminant and construct validity good by factor analysis — labelled slice 1 of this report: consistency and validity by domain, never as one instrument-wide coefficient

Study: Validation study (primary report) — secondary psychometric analysis of treatment-trial data; slice 1: reliability and validity

Population: Patients with symptoms of overactive bladder with urge incontinence in Japan, from a 12-week, randomised, double-blind, placebo-controlled trial comparing tolterodine with oxybutynin; Cronbach's alpha was calculated as the reliability index, inter-domain correlations assessed convergent and discriminant validity, and factor analysis explored the KHQ's underlying structure; properties were similar between males and females.

Summary: Japanese validation, slice 1 — reliability and validity (Uemura 2004, Neurourology and Urodynamics — secondary psychometric analysis of data from a 12-week randomised tolterodine-vs-oxybutynin trial in overactive bladder with urge incontinence): domain α coefficients generally >0.60, with two weaker domains (personal relationships in males 0.47, severity / coping in females 0.59); convergent, discriminant and construct validity good by factor analysis — labelled slice 1 of this report: consistency and validity by domain, never as one instrument-wide coefficient

Result: The KHQ's reliability was evidenced by Cronbach's alpha coefficients of >0.60, indicating reasonable consistency except for the personal relationship domain in males (0.47) and the severity (coping) measure domain in females (0.59). Discriminant, convergent and construct validity were also good, with the factor analysis identifying those factors which the KHQ was intended to measure, as published.

Watch out: Trial-participant spectrum: these are psychometrics inside a drug trial's selected OAB population, not a clinic validation sample. The weak domains (0.47, 0.59) print — a single 'α >0.60' headline without them would misstate the instrument.

Source: Uemura et al. Reliability and validity of King's Health Questionnaire in patients with symptoms of overactive bladder with urge incontinence in Japan. Neurourology and urodynamics. 2004. PMID: 14983417. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Humans · Japan · Male · Middle Aged · Psychometrics · Reproducibility of Results · Surveys and Questionnaires · Urinary Bladder Diseases/diagnosis

Card 2 — Japanese validation, slice 2 — responsiveness (Uemura 2004, same report, same trial data): KHQ domains were generally responsive to clinical efficacy variables and showed statistically significant sensitivity to change in patients' perception of bladder condition in all domains except General Health Perception — labelled slice 2 of this report: within-trial responsiveness, with that provenance

Study: Validation study (primary report) — secondary psychometric analysis of treatment-trial data; slice 2: responsiveness (same report as slice 1, not an additional source)

Population: The same Japanese overactive-bladder trial dataset as the previous card; sensitivity to clinical change was evaluated against clinical efficacy variables and patients' perception of bladder condition.

Summary: Japanese validation, slice 2 — responsiveness (Uemura 2004, same report, same trial data): KHQ domains were generally responsive to clinical efficacy variables and showed statistically significant sensitivity to change in patients' perception of bladder condition in all domains except General Health Perception — labelled slice 2 of this report: within-trial responsiveness, with that provenance

Result: KHQ domains were generally responsive to clinical efficacy variables; the KHQ also showed statistically significant sensitivity to change in patients' perception of bladder condition in all domains, except General Health Perception, as published.

Watch out: Responsiveness here is change within a 12-week antimuscarinic trial — it shows the domains move when bladder condition changes under treatment, not that a KHQ change measures leakage change. No KHQ figure on this shelf is a leakage quantity.

Source: Uemura et al. Reliability and validity of King's Health Questionnaire in patients with symptoms of overactive bladder with urge incontinence in Japan. Neurourology and urodynamics. 2004. PMID: 14983417. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Humans · Japan · Male · Middle Aged · Psychometrics · Reproducibility of Results · Surveys and Questionnaires · Urinary Bladder Diseases/diagnosis

Card 3 — Portuguese validation (Tamanini 2004, International Brazilian Journal of Urology — prospective multicentre study, 68 women before and one month after sling surgery for urodynamic stress incontinence): moderate concurrent validity against clinical parameters, strong internal consistency (higher after treatment), and large responsiveness (standardised effect size / response mean), with objective pad-use changes correlating with score changes — small N (68) prints on the face

Study: Validation study (primary report) — small N (68 women) prints

Population: 68 female patients with urodynamically diagnosed urinary stress incontinence at 4 tertiary referral centres, treated mostly (73%) with the synthetic sling procedure and assessed before and one month after surgery with the Portuguese KHQ, urodynamic testing, Stamey incontinence grading, pad usage and number of pads used per day.

Summary: Portuguese validation (Tamanini 2004, International Brazilian Journal of Urology — prospective multicentre study, 68 women before and one month after sling surgery for urodynamic stress incontinence): moderate concurrent validity against clinical parameters, strong internal consistency (higher after treatment), and large responsiveness (standardised effect size / response mean), with objective pad-use changes correlating with score changes — small N (68) prints on the face

Result: Concurrent validity showed good correlations in some KHQ domains to clinical parameters (described overall as moderate concurrent validity). Internal consistency was higher after treatment compared with preoperative values (described as strong). Objective parameters such as pad usage and number of pads per day correlated significantly with changes in post-treatment KHQ scores. Responsiveness, expressed as standardised effect size and standardised response mean, was large, as published.

Watch out: Small, single-indication surgical sample with one-month follow-up: large responsiveness after a gold-standard operation is a best-case change setting, not expected change in ordinary care. Pad-use correlation is association with a behaviour count, not agreement with pad-test weights (#8089).

Source: Tamanini et al. Concurrent validity, internal consistency and responsiveness of the Portuguese version of the King's Health Questionnaire (KHQ) in women after stress urinary incontinence surgery. International braz j urol : official journal of the Brazilian Society of Urology. 2004. PMID: 15663805. Registry ID: none in the record. MeSH: Female · Health Status Indicators · Humans · Postoperative Period · Prospective Studies · Prostheses and Implants · Quality of Life · Reproducibility of Results · Surveys and Questionnaires · Urinary Incontinence, Stress/surgery

Card 4 — German validation (Bjelic-Radisic 2005, Neurourology and Urodynamics — 145 women treated for stress incontinence with surgery or physiotherapy, KHQ and SF-36 before and after treatment): subscale α 0.76–0.86, content validity good and criterion validity low-to-moderate against the SF-36, the highest correlation between the two questionnaires' general-health-perception subscales

Study: Validation study (primary report)

Population: 145 women treated for stress incontinence with surgery or physiotherapy in Germany, completing the German-language KHQ and the SF-36 before and after treatment; psychometric analyses determined reliability (Cronbach's alpha), internal and external validity, and responsiveness of the KHQ subscales.

Summary: German validation (Bjelic-Radisic 2005, Neurourology and Urodynamics — 145 women treated for stress incontinence with surgery or physiotherapy, KHQ and SF-36 before and after treatment): subscale α 0.76–0.86, content validity good and criterion validity low-to-moderate against the SF-36, the highest correlation between the two questionnaires' general-health-perception subscales

Result: The KHQ showed good internal consistency, content validity, and criterion validity as measured by correlation with SF-36 scores. Cronbach's alpha ranged from 0.76 to 0.86 across subscales. Correlations between KHQ subscales and the SF-36 were low to moderate, the highest between the general health perception subscales of both questionnaires, as published.

Watch out: Criterion validity against a generic quality-of-life questionnaire (SF-36) is low-to-moderate by design — a condition-specific instrument should not mirror a generic one; low-to-moderate here is not a failure figure, and prints with that reading.

Source: Bjelic-Radisic et al. Psychometric properties and validation of the German-language King's Health Questionnaire in women with stress urinary incontinence. Neurourology and urodynamics. 2005. PMID: 15578627. Registry ID: none in the record. MeSH: Adult · Aged · Austria · Female · Humans · Language · Middle Aged · Psychometrics/standards · Quality of Life · Reproducibility of Results · Surveys and Questionnaires/standards · Urinary Incontinence, Stress/diagnosis,psychology

Card 5 — Synthesis: the KHQ's domain-level consistency spans α 0.47–0.86 across 3 validations — German subscales 0.76–0.86, Japanese domains generally >0.60 with two weaker sex-specific domains, Portuguese consistency strong and higher after surgery — and it measures quality-of-life impact, never leakage amount

Study: Synthesis

Population: Synthesis of the 3 validation reports carded above (Japanese trial dataset, N not documented in its abstract; Portuguese 68 women; German 145 women).

Summary: Synthesis: the KHQ's domain-level consistency spans α 0.47–0.86 across 3 validations — German subscales 0.76–0.86, Japanese domains generally >0.60 with two weaker sex-specific domains, Portuguese consistency strong and higher after surgery — and it measures quality-of-life impact, never leakage amount

Result: Across the anchors: reliability is domain-bound (Japanese >0.60 generally, exceptions 0.47 in males' personal relationships and 0.59 in females' severity / coping; German 0.76–0.86; Portuguese strong, higher post-treatment); validity is good by factor analysis and domain correlations in Japan, moderate concurrently against clinical parameters in Portugal, and low-to-moderate against the SF-36 in Germany; responsiveness is large after sling surgery and significant against bladder-condition perception within the Japanese trial. No single instrument-wide α is printed: none exists in these reports.

Watch out: Composition discipline: 3 validations, one a secondary analysis of drug-trial data. Cross-points in prose only: ICIQ-UI SF (#8084), UDI-6 / IIQ-7 (#8085), OAB-q (#8087), voiding diary (#8088), pad-weighing test (#8089), IPSS (#8005) — impact figures are not commensurable with diary counts or pad weights.

Source: Synthesis of the reports carded above; no additional source.