SourceMed · Shelf #8102 in the ask interface
SQiD single informant question for delirium: NPV 74–91% across spectra, but sensitivity 80% on 21 patients, 77% in the pilot and only 44% in cancer centres — 4 reports
Shelf #8102 · Brain, stroke & mind
SCREENING ACCURACY — negative predictive value the consistent limb, sensitivity NOT ESTABLISHED as stable: 4 reports; derivation sensitivity 80% / specificity 71% on only 21 patients (interval 28.3 to 99.49%), pilot 77% / 51%, cancer-centre sensitivity 44% with specificity 87%, and the 500-patient geriatric study gives no SQiD-specific pair (comparative statement only); a screening-accuracy stamp, not a treatment stamp — a negative SQiD does not exclude delirium
Stamped: 2026-11-28.
Evidence published: 2010–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does the SQiD (Single Question in Delirium — one informant question, 'Do you think [patient] has been more confused lately?', asked of a friend or family member) detect delirium against psychiatric / specialist reference assessment — what sensitivity, specificity and negative predictive value did its original study find, and what did the general-medical pilot, the geriatric diagnostic-accuracy study and the cancer-centre study find? Report composition: 4 reports (original study, general-medical pilot, geriatric diagnostic-accuracy study limb, cancer-centre study).
Balance of the evidence
Report composition prints: 4 reports — the original study (PMID 20837733, programme-labelled: the Sands group's own report, N=21 consented patients), the general-medical pilot (PMID 26059554, N=100), the geriatric diagnostic-accuracy study (PMID 27503794, N=500, a multi-tool study in which the SQiD was one of six brief tools — no SQiD-specific pair may be printed from it beyond the comparative statement on its card), and the cancer-centre study (PMID 33461523, 73 patients with both SQiD and psychiatrist interview). A fifth report (PMID 41074921, 2025, SQiD + 4AT combination, 403 patients) has no independent reference-standard accuracy pair and is NOT counted as an anchor. This is a screening-accuracy shelf, not a delirium-treatment shelf. Sensitivity is the weak limb outside the tiny derivation: 44% in the cancer-centre study, where specificity (87%) was its strength — the reverse of the pilot's pattern (77% / 51%) — and both patterns print. The derivation's confidence intervals (sensitivity 28.3–99.49%) are derivation-spectrum widths and print. Informant availability is part of the test: patients without a friend / family informant cannot be SQiD-screened, and no card implies otherwise. Distinct from the CAM family (packs #7615 / #7716 / #7616 / #7753) and from FAM-CAM (#8082): the SQiD is a single informant question, not the CAM algorithm re-worded; cross-points in prose only, no anchor shared.
MeSH: Adult · Aged · Confusion/diagnosis · Delirium/diagnosis · Female · Humans · Male · Middle Aged · Neoplasms/complications · Neuropsychological Tests · Sensitivity and Specificity · Surveys and Questionnaires/standards · Aged, 80 and over · Consciousness · Delirium/diagnosis,physiopathology,psychology · Hospitals, General · Pilot Projects · Predictive Value of Tests · Psychometrics · Reproducibility of Results · Age Factors · Area Under Curve · Cognition · Delirium/diagnosis,psychology · Geriatric Assessment/methods · Hospitals, Teaching · Inpatients · Mass Screening/methods,standards · Mental Status and Dementia Tests/standards · ROC Curve · Reference Standards · Risk Factors · Wechsler Memory Scale/standards · Cross-Sectional Studies · Delirium/complications,diagnosis,epidemiology · Feasibility Studies · Hospitalization/statistics & numerical data · Mass Screening/methods · Neoplasms/complications,therapy · Psychometrics/methods
Cards (5)
Card 1 — Original study (Sands 2010, Palliative Medicine — 21 consented patients of 33 target admissions, against psychiatrist interview): sensitivity 80% (95% CI 28.3 to 99.49) and specificity 71% (41.90 to 91.61), NPV 91%, κ 0.431 — programme-labelled: the Sands group's own report; very small N (21 patients) prints on the face
Study: Original diagnostic study (primary report) — programme-labelled; very small N (21) prints
Population: 21 consented patients of 33 'target' admissions; the single question — 'Do you think [name of patient] has been more confused lately?' — was put to a friend or family member; results were compared with psychiatrist interview (the reference standard); the Confusion Assessment Method (CAM) and two other tools were also applied.
Summary: Original study (Sands 2010, Palliative Medicine — 21 consented patients of 33 target admissions, against psychiatrist interview): sensitivity 80% (95% CI 28.3 to 99.49) and specificity 71% (41.90 to 91.61), NPV 91%, κ 0.431 — programme-labelled: the Sands group's own report; very small N (21 patients) prints on the face
Result: Compared with psychiatrist interview, the SQiD achieved a sensitivity of 80% (95% CI 28.3 to 99.49%) and a specificity of 71% (41.90 to 91.61%). The SQiD showed a negative predictive value of 91% (58.72 to 99.77%); the CAM's NPV was 80% (51.91 to 95.67%). Kappa for SQiD with psychiatrist interview was 0.431 (p = 0.023); the CAM's kappa was 0.37 (p = 0.050). The CAM had only 40% sensitivity in the hands of minimally trained clinical users in this study, as published.
Watch out: Very small N prints: 21 consented patients, and the sensitivity interval (28.3 to 99.49%) spans almost the whole plausible range — this is a derivation-spectrum figure, not a settled accuracy pair. The question requires an informant; patients without one cannot be tested.
Source: Sands et al. Single Question in Delirium (SQiD): testing its efficacy against psychiatrist interview, the Confusion Assessment Method and the Memorial Delirium Assessment Scale. Palliative medicine. 2010. PMID: 20837733. Registry ID: none in the record. MeSH: Adult · Aged · Confusion/diagnosis · Delirium/diagnosis · Female · Humans · Male · Middle Aged · Neoplasms/complications · Neuropsychological Tests · Sensitivity and Specificity · Surveys and Questionnaires/standards
Card 2 — General-medical pilot (Lin 2015, Australasian Journal on Ageing — 100 general-medical patients against geriatric-consultant assessment): SQiD sensitivity 77% (95% CI 56 to 91), specificity 51% (37 to 64) and NPV 83% (66 to 93) — the companion tool SQeeC's figures (83% / 81% / NPV 97%) print as comparators
Study: Pilot diagnostic study (primary report)
Population: 100 patients in the general medical wards of a general hospital; the SQeeC was administered to the patients and the SQiD to their informants; data were compared with the reference standard of geriatric consultant assessment of delirium.
Summary: General-medical pilot (Lin 2015, Australasian Journal on Ageing — 100 general-medical patients against geriatric-consultant assessment): SQiD sensitivity 77% (95% CI 56 to 91), specificity 51% (37 to 64) and NPV 83% (66 to 93) — the companion tool SQeeC's figures (83% / 81% / NPV 97%) print as comparators
Result: Compared with the reference standard, the SQiD had a sensitivity of 77% (95% CI 56 to 91%), a specificity of 51% (95% CI 37 to 64%) and a negative predictive value of 83% (95% CI 66 to 93%). The companion tool SQeeC, printed here as a comparator, had a sensitivity of 83% (95% CI 52 to 98%), a specificity of 81% (95% CI 72 to 89%) and an NPV of 97% (95% CI 90 to 100%), as published.
Watch out: Specificity of 51% means roughly half of non-delirious patients screen positive in this spectrum — the pilot's pattern (sensitive, non-specific) is the reverse of the cancer-centre study's, and both print. A pilot study of two tools; the SQeeC figures are comparators, not SQiD performance.
Source: Lin et al. Screening in delirium: A pilot study of two screening tools, the Simple Query for Easy Evaluation of Consciousness and Simple Question in Delirium. Australasian journal on ageing. 2015. PMID: 26059554. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Consciousness · Delirium/diagnosis,physiopathology,psychology · Female · Hospitals, General · Humans · Male · Pilot Projects · Predictive Value of Tests · Psychometrics · Reproducibility of Results · Surveys and Questionnaires/standards
Card 3 — Geriatric diagnostic-accuracy study (Hendry 2016, Age and Ageing — 500 consecutive geriatric-medical inpatients, 18.6% definite delirium): the SQiD was one of six brief tools and showed performance similar to the AMT-4 / AMT-10 / months-backwards group (good sensitivity, poor specificity for definite delirium) — labelled a multi-tool study: no SQiD-specific pair is printed from it beyond that comparative statement
Study: Diagnostic test accuracy study (primary report) — multi-tool study; SQiD limb is comparative only
Population: A consecutive cohort of 500 non-elective elderly-care inpatients (older than 65 years; mean age 83) admitted to a geriatric medical assessment unit of an urban teaching hospital; reference assessments were clinical diagnoses of delirium by elderly-care physicians (93 of 500, 18.6%, definite delirium; 104, 20.8%, possible delirium; 277, 55.4%, no delirium). Six routine screening tests were evaluated: AMT-10, AMT-4, 4AT, brief CAM (bCAM), months of the year backwards (MOTYB) and the informant SQiD.
Summary: Geriatric diagnostic-accuracy study (Hendry 2016, Age and Ageing — 500 consecutive geriatric-medical inpatients, 18.6% definite delirium): the SQiD was one of six brief tools and showed performance similar to the AMT-4 / AMT-10 / months-backwards group (good sensitivity, poor specificity for definite delirium) — labelled a multi-tool study: no SQiD-specific pair is printed from it beyond that comparative statement
Result: For diagnosis of definite delirium, AMT-4 (cut-point <3/4) had a sensitivity of 92.7% (95% CI 84.8 to 97.3) with a specificity of 53.7% (48.1 to 59.2); AMT-10 (<4/10), MOTYB (<4/12) and the SQiD showed similar performance. The bCAM had a sensitivity of 70.3% (58.5 to 80.3) with a specificity of 91.4% (87.7 to 94.3), and the 4AT (>4/12) a sensitivity of 86.7% (77.5 to 93.2) and a specificity of 69.5% (64.4 to 74.3). The authors conclude short screening tools such as AMT-4 or MOTYB have good sensitivity but poor specificity for definite delirium and may be reasonable as a first stage in assessment, as published.
Watch out: Multi-tool study: the abstract prints exact pairs for AMT-4, bCAM and 4AT but only a comparative statement for the SQiD ('similar performance' to the AMT-10 / MOTYB group). No SQiD-specific sensitivity / specificity pair may be printed from this report, and the comparator pairs printed here belong to the other tools.
Source: Hendry et al. Evaluation of delirium screening tools in geriatric medical inpatients: a diagnostic test accuracy study. Age and ageing. 2016. PMID: 27503794. Registry ID: none in the record. MeSH: Age Factors · Aged · Aged, 80 and over · Area Under Curve · Cognition · Delirium/diagnosis,psychology · Female · Geriatric Assessment/methods · Hospitals, Teaching · Humans · Inpatients · Male · Mass Screening/methods,standards · Mental Status and Dementia Tests/standards · Predictive Value of Tests · ROC Curve · Reference Standards · Reproducibility of Results · Risk Factors · Wechsler Memory Scale/standards
Card 4 — Cancer-centre study (Sands 2021, BMC Cancer — multicentre, two comprehensive cancer centres; 73 patients with both SQiD and psychiatrist interview): NPV 74 (95% CI 67 to 81), κ 0.32, specificity 87% (74 to 95) and sensitivity 44% (41 to 80) — higher than the CAM's 26% in the same study, with the pattern reversed from the pilot (specificity the strength, sensitivity the weakness)
Study: Diagnostic study (primary report) — multicentre
Population: Inpatients in two comprehensive cancer centres, prospectively screened between May 2012 and July 2015; clinical staff asked informants the SQiD ('Do you feel that [patient's name] has been more confused lately?'); the SQiD plus CAM was applied to 122 patients, of whom 73 had both the SQiD and a psychiatrist interview (the reference standard, DSM criteria). Median age 65 years; 70% had stage 4 cancer.
Summary: Cancer-centre study (Sands 2021, BMC Cancer — multicentre, two comprehensive cancer centres; 73 patients with both SQiD and psychiatrist interview): NPV 74 (95% CI 67 to 81), κ 0.32, specificity 87% (74 to 95) and sensitivity 44% (41 to 80) — higher than the CAM's 26% in the same study, with the pattern reversed from the pilot (specificity the strength, sensitivity the weakness)
Result: The SQiD's negative predictive value was 74 (95% CI 67 to 81) and its kappa 0.32, similar to the CAM's (NPV 72, 67 to 77; kappa 0.32) against psychiatrist interview. The specificity of the SQiD was 87% (74 to 95). The SQiD had higher sensitivity than the CAM (44% [95% CI 41 to 80] versus 26% [10 to 48]). The CAM identified only a small number of delirious cases but all were true positives, as published.
Watch out: Sensitivity of 44% means the single question missed over half of psychiatrist-diagnosed delirium in this cancer-centre spectrum — a negative SQiD does not exclude delirium. The 73-patient analysis set (of 122 screened) prints; the population is hospitalised cancer patients, 70% stage 4.
Source: Sands et al. "SQiD, the Single Question in Delirium; can a single question help clinicians to detect delirium in hospitalised cancer patients?" running heading Single Question in Delirium" (Bcan-D-20-01665). BMC cancer. 2021. PMID: 33461523. Registry ID: none in the record. MeSH: Aged · Cross-Sectional Studies · Delirium/complications,diagnosis,epidemiology · Feasibility Studies · Female · Hospitalization/statistics & numerical data · Humans · Male · Mass Screening/methods · Middle Aged · Neoplasms/complications,therapy · Predictive Value of Tests · Psychometrics/methods · Reproducibility of Results
Card 5 — Synthesis (4 reports): the SQiD's consistent limb is its negative predictive value (91% in the tiny derivation, 83% in the pilot, 74 in the cancer-centre study); its sensitivity is spectrum-dependent (80% on 21 patients, 77% in the pilot, 44% in cancer centres) and its specificity swings the other way (71% / 51% / 87%)
Study: Synthesis
Population: Synthesis of the 4 reports carded above: the original study (21 patients), the general-medical pilot (100 patients), the geriatric diagnostic-accuracy study (500 inpatients; SQiD limb comparative only) and the cancer-centre study (73 patients with both tests).
Summary: Synthesis (4 reports): the SQiD's consistent limb is its negative predictive value (91% in the tiny derivation, 83% in the pilot, 74 in the cancer-centre study); its sensitivity is spectrum-dependent (80% on 21 patients, 77% in the pilot, 44% in cancer centres) and its specificity swings the other way (71% / 51% / 87%)
Result: No single sensitivity / specificity pair describes the SQiD: the derivation pair (80% / 71%) rests on 21 patients with a sensitivity interval of 28.3 to 99.49%; the pilot pair (77% / 51%) and the cancer-centre pair (44% / 87%) reverse which limb is strong. The 500-patient geriatric study places the SQiD in the good-sensitivity / poor-specificity group of brief tools without printing an SQiD-specific pair. Across spectra the NPV (74–91%) is the most consistent figure, and it is prevalence-dependent in each setting.
Watch out: A negative SQiD lowers the probability of delirium but does not exclude it — at 44% sensitivity in the cancer-centre spectrum it misses more than it catches. The test needs an informant who knows the patient; absence of an informant is absence of the test, not a negative result.
Source: Synthesis of the reports carded above; no additional source.