Functional Gait Assessment: reliability high in three samples (ICC 0.86–0.986) on a 6-patient derivation plus two 63-patient studies — fall prediction not established
Shelf #8104 · Geriatrics, frailty & deprescribing
MEASUREMENT PROPERTIES — reliability established, fall prediction NOT ESTABLISHED: 3 reports (1 derivation study with 6 rated patients + 2 cross-sectional psychometric studies); inter-rater ICC 0.86 at derivation, 0.94 in stroke (MDC 5.02) and 0.986 in knee osteoarthritis; both cut-offs (≥20; 25.5) discriminate patients from healthy adults only — no prospective fall evidence exists on this shelf; a measurement-properties stamp, not a fall-prediction stamp
Stamped: 2026-11-28.
Evidence published: 2004–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the Functional Gait Assessment (FGA — a 10-item gait assessment developed from the Dynamic Gait Index, adding tasks such as tandem walking, walking with eyes closed and walking backwards, each item 0–3, total 0–30) — what reliability, internal consistency and validity did its original vestibular-disorders study establish, and what reliability, measurement error and cut-off did the 2026 stroke and knee-osteoarthritis psychometric studies find? Report composition: 3 reports (1 derivation study with 6 rated patients + 2 cross-sectional psychometric studies).
Balance of the evidence
Report composition prints: 3 reports — 1 derivation study with 6 rated patients (PMID 15449976, programme-labelled: the Wrisley group's own report; 10 raters concurrently rated 6 patients) + 2 cross-sectional psychometric studies from 2026 (stroke, PMID 41484708, 63 patients + 30 healthy older adults; knee osteoarthritis, PMID 42668502, 63 patients + 30 healthy older adults). Neither 2026 study measures fall prediction prospectively, and no card may present the ≥20 stroke cut-off or the 25.5 knee-osteoarthritis cut-off — both are patient-versus-healthy discrimination values — as fall-risk thresholds. The derivation's concurrent-validity correlations range down to 0.11 and print as a range, not a summary claim. Provenance printed: the stroke report (PMID 41484708) is the report Slate 29 sighted at candidate level and could not then verify. Distinct from pack #8103 (DGI family — the FGA is a separate, expanded instrument derived from it, with its own 0–30 score range) and pack #7821 (Berg Balance Scale): cross-points in prose only, no anchor shared. This is a measurement-properties shelf, not a fall-prediction or treatment shelf.
MeSH: Adult · Aged · Factor Analysis, Statistical · Female · Gait · Humans · Male · Middle Aged · Observer Variation · Physical Therapy Modalities/methods · Postural Balance · Reproducibility of Results · Vestibular Diseases/diagnosis,rehabilitation · Stroke/physiopathology,complications,diagnosis,psychology · Psychometrics · Cross-Sectional Studies · Postural Balance/physiology · Gait/physiology · Aged, 80 and over · Disability Evaluation · Gait Disorders, Neurologic/diagnosis,etiology
Cards (4)
Card 1 — Derivation / first psychometric study (Wrisley 2004, Physical Therapy — vestibular disorders; 10 raters concurrently rated 6 patients, tested twice an hour apart): inter-rater ICC 0.86, intra-rater ICC 0.74, internal consistency α 0.79, and correlations with balance measures 0.11–0.67 — programme-labelled: the Wrisley group's own report; its reliability Ns (6 patients, 10 raters) print on the face
Study: Derivation / psychometric study (primary report) — programme-labelled; 6 rated patients print
Population: Seven physical therapists from various practice settings, 3 physical therapist students and 6 patients with vestibular disorders. All 10 raters concurrently rated the 6 patients on the Functional Gait Assessment (a 10-item gait assessment based on the Dynamic Gait Index, each item 0–3, total 0–30); patients completed the FGA twice with an hour's rest between sessions. Reliability used intraclass correlation coefficients (2,1); concurrent validity used Spearman correlations with balance and gait measurements.
Summary: Derivation / first psychometric study (Wrisley 2004, Physical Therapy — vestibular disorders; 10 raters concurrently rated 6 patients, tested twice an hour apart): inter-rater ICC 0.86, intra-rater ICC 0.74, internal consistency α 0.79, and correlations with balance measures 0.11–0.67 — programme-labelled: the Wrisley group's own report; its reliability Ns (6 patients, 10 raters) print on the face
Result: Intraclass correlation coefficients of 0.86 and 0.74 were found for inter-rater and intra-rater reliability of total FGA scores. Internal consistency was 0.79 (Cronbach alpha). Spearman correlation coefficients of FGA scores with balance measurements ranged from 0.11 to 0.67. The authors conclude the FGA demonstrates acceptable reliability, internal consistency and concurrent validity with other balance measures in patients with vestibular disorders, as published.
Watch out: Six patients: every reliability coefficient on this card rests on 6 rated patients (10 raters), in vestibular disorders only. The validity correlations span 0.11–0.67 — the lower end is negligible, and the range, not a summary adjective, is the finding.
Source: Wrisley et al. Reliability, internal consistency, and validity of data obtained with the functional gait assessment. Physical therapy. 2004. PMID: 15449976. Registry ID: none in the record. MeSH: Adult · Aged · Factor Analysis, Statistical · Female · Gait · Humans · Male · Middle Aged · Observer Variation · Physical Therapy Modalities/methods · Postural Balance · Reproducibility of Results · Vestibular Diseases/diagnosis,rehabilitation
Card 2 — Stroke psychometric study (Ng 2026, BMC Neurology — 63 people with stroke and 30 healthy older adults): inter-rater ICC 0.94, test–retest ICC 0.85, SEM 1.81, MDC 5.02, significant correlations with Fugl-Meyer lower-extremity, ankle strength, Berg, limits-of-stability and FAAM measures, and an optimal cut-off of ≥20 differentiating stroke from healthy adults — provenance printed: the report Slate 29 sighted at candidate level
Study: Psychometric study (primary report) — cross-sectional
Population: Sixty-three people with stroke and thirty healthy older adults in a cross-sectional study; the FGA and a battery of comparator measures (Fugl-Meyer Assessment Lower Extremity, ankle muscle strength, Montreal Cognitive Assessment, Limit of Stability, Berg Balance Scale, Foot and Ankle Ability Measure, Oxford Participation and Activities Questionnaire, SF-12) were assessed in randomised order on day 1 and day 2; healthy subjects completed the FGA on day 1 only.
Summary: Stroke psychometric study (Ng 2026, BMC Neurology — 63 people with stroke and 30 healthy older adults): inter-rater ICC 0.94, test–retest ICC 0.85, SEM 1.81, MDC 5.02, significant correlations with Fugl-Meyer lower-extremity, ankle strength, Berg, limits-of-stability and FAAM measures, and an optimal cut-off of ≥20 differentiating stroke from healthy adults — provenance printed: the report Slate 29 sighted at candidate level
Result: The FGA showed excellent inter-rater reliability (ICC = 0.94) and good test–retest reliability (ICC = 0.85) in people with stroke. The standard error of measurement was 1.81 and the minimal detectable change 5.02. Significant correlations were found between the FGA and Fugl-Meyer lower-extremity, ankle strength, Berg Balance Scale, limits of stability and FAAM measures (p < 0.05). Bland–Altman inter-rater mean difference was 0.71 (95% limits of agreement −3.60 to 5.03). An optimal cut-off point of ≥20 was identified, with lower scores indicating greater gait and balance impairment, effectively differentiating people with stroke from healthy adults, as published.
Watch out: The ≥20 cut-off discriminates stroke patients from healthy adults — it is NOT a fall-risk threshold, and this cross-sectional study measured no falls. An MDC of 5.02 on a 0–30 scale means individual change smaller than ~5 points is within measurement error.
Source: Ng et al. Psychometric properties of functional gait assessment in people with stroke. BMC neurology. 2026. PMID: 41484708. Registry ID: none in the record. MeSH: Humans · Female · Male · Stroke/physiopathology,complications,diagnosis,psychology · Aged · Psychometrics · Cross-Sectional Studies · Middle Aged · Reproducibility of Results · Postural Balance/physiology · Gait/physiology · Aged, 80 and over · Disability Evaluation · Gait Disorders, Neurologic/diagnosis,etiology
Card 3 — Knee-osteoarthritis psychometric study (Ng 2026, Journal of Exercise Science and Fitness — 63 people with knee osteoarthritis and 30 healthy older adults): KOA scores lower than controls (23.49 ± 3.87 vs 27.03 ± 2.51), inter-rater ICC 0.986, test–retest ICC 0.897, moderate-to-strong correlations with knee-function measures, and an optimal cut-off of 25.5 (AUC 0.795–0.798, sensitivity 0.867, specificity 0.651–0.667) distinguishing KOA from healthy adults
Study: Psychometric study (primary report) — cross-sectional
Population: 63 individuals with knee osteoarthritis (mean age 66.6 years) and 30 healthy older adults (mean age 68.1 years) in a cross-sectional study; the FGA was assessed alongside knee strength, limits of stability, Berg Balance Scale, Timed Up and Go, five-times sit-to-stand, balance-confidence, KOOS, falls-efficacy and participation measures; the KOA group was assessed on day 1 and day 2 (7 days apart), the healthy group on day 1 only.
Summary: Knee-osteoarthritis psychometric study (Ng 2026, Journal of Exercise Science and Fitness — 63 people with knee osteoarthritis and 30 healthy older adults): KOA scores lower than controls (23.49 ± 3.87 vs 27.03 ± 2.51), inter-rater ICC 0.986, test–retest ICC 0.897, moderate-to-strong correlations with knee-function measures, and an optimal cut-off of 25.5 (AUC 0.795–0.798, sensitivity 0.867, specificity 0.651–0.667) distinguishing KOA from healthy adults
Result: People with KOA had significantly lower FGA scores than healthy older adults (23.49 ± 3.87 vs 27.03 ± 2.51; p < 0.001). The FGA demonstrated excellent inter-rater reliability (ICC = 0.986) and good test–retest reliability (ICC = 0.897). FGA scores showed moderate-to-strong positive correlations with affected knee strength, limits of stability, Berg, KOOS and balance confidence (r = 0.36–0.70) and significant negative correlations with Timed Up and Go, sit-to-stand, falls-efficacy and participation scores (r = −0.32 to −0.69). The optimal cut-off for differentiating KOA from healthy controls was 25.5 (AUC 0.795–0.798, sensitivity 0.867, specificity 0.651–0.667), as published. The record for this report carries no MeSH terms (printed in its source line).
Watch out: The 25.5 cut-off discriminates KOA patients from healthy controls — it is NOT a fall-risk threshold, and no falls were measured. The authors themselves state further confirmation in larger, more diverse cohorts is required. This record carries no MeSH terms; none are supplied from elsewhere.
Source: Ng et al. The psychometric properties of Functional Gait Assessment (FGA) in assessing walking ability in people with knee osteoarthritis. Journal of exercise science and fitness. 2026. PMID: 42668502. Registry ID: none in the record. MeSH: none in the record
Card 4 — Synthesis (3 reports — 1 derivation with 6 rated patients + 2 cross-sectional psychometric studies): FGA reliability is consistently high across vestibular, stroke and knee-osteoarthritis samples (inter-rater ICC 0.86–0.986), but its evidence base is three studies, two populations are single 63-patient samples from one research group, and fall prediction is NOT ESTABLISHED
Study: Synthesis
Population: Synthesis of the 3 reports carded above: the derivation (6 patients, 10 raters, vestibular disorders), the stroke study (63 + 30) and the knee-osteoarthritis study (63 + 30) — the two 2026 studies share a first author and design.
Summary: Synthesis (3 reports — 1 derivation with 6 rated patients + 2 cross-sectional psychometric studies): FGA reliability is consistently high across vestibular, stroke and knee-osteoarthritis samples (inter-rater ICC 0.86–0.986), but its evidence base is three studies, two populations are single 63-patient samples from one research group, and fall prediction is NOT ESTABLISHED
Result: Inter-rater reliability: 0.86 (derivation, 6 patients), 0.94 (stroke) and 0.986 (knee osteoarthritis); test–retest: 0.74 intra-rater (derivation), 0.85 (stroke) and 0.897 (KOA). Measurement error is quantified only in stroke (SEM 1.81, MDC 5.02). Both cut-offs on this shelf (≥20 in stroke; 25.5 in KOA) discriminate patients from healthy adults. Concurrent-validity correlations are wide in every sample (0.11–0.67 at derivation; 0.36–0.70 / −0.32 to −0.69 in KOA). No card measures prospective falls, responsiveness to treatment, or performance outside vestibular, stroke and knee-osteoarthritis populations.
Watch out: Composition prints: 1 derivation study with 6 rated patients + 2 cross-sectional psychometric studies. Reliability established is not fall prediction established — no card on this shelf may be used to set a fall-risk threshold.
Source: Synthesis of the reports carded above; no additional source.