SourceMed · Shelf #8108 in the ask interface
Motor Activity Assessment Scale: κ 0.83 at derivation in 25 patients, ICC 0.81 across mixed raters — TYPE-FLAG printed: derivation typed RCT against a psychometric design (adjudication 1)
Shelf #8108 · Critical care & sepsis
MEASUREMENT PROPERTIES — inter-rater reliability established in small ICU samples: 3 reports (1 derivation + 1 inter-rater study + 1 multi-scale evaluation; 129 patients in total); derivation κ 0.83 (0.72 to 0.94) in 25 patients / 400 paired assessments, mixed-rater ICC 0.81 in 31 patients; TYPE-FLAG: the derivation record is typed Randomized Controlled Trial at PubMed against a prospective psychometric design — counted on substance with the flag printed; a measurement-properties stamp, not a sedation-treatment stamp
Stamped: 2026-11-28.
Evidence published: 1999–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How reliable and valid is the Motor Activity Assessment Scale (MAAS — a seven-category ICU sedation scale from unresponsive (0) through restless / cooperative (5) to dangerously agitated (6), adapted from the SAS framework) as a bedside sedation measure in mechanically ventilated adults — what validity and inter-rater reliability did its derivation establish against a visual-analogue assessment and physiological / agitation-sequelae criteria, how reliably do mixed ICU raters score it against a comparator scale, and how did it perform in the four-scale COVID-era ICU evaluation? Report composition: 3 reports (1 derivation + 1 inter-rater study + 1 multi-scale evaluation). TYPE-FLAG: the derivation anchor carries a publication-type mismatch (typed Randomized Controlled Trial against a prospective psychometric design) — counted on substance, with the type-flag printed on the face.
Balance of the evidence
Report composition prints: 3 reports — 1 derivation (PMID 10446819) + 1 inter-rater study (PMID 11244675) + 1 multi-scale evaluation (PMID 40770409). TYPE-FLAG — PRINTED ON THE FACE (a publication-type mismatch on an anchor is counted on substance with the type-flag printed): the derivation record (PMID 10446819) is typed Clinical Trial / Randomized Controlled Trial at PubMed although its described design is a prospective psychometric evaluation with no randomised intervention; it is counted on substance and the discrepancy is printed on its card, in this balance and in the stamp. The derivation's patient N is 25 — its 400 assessments are repeated measures and print as such, never as 400 patients. Criterion validity in the derivation is against a subjective visual-analogue scale and physiological correlates, not against a physiological standard, and prints as such. The COVID-era study (PMID 40770409) is labelled a multi-scale study: its κ range (0.71–0.89) is the four-scale family figure and no MAAS-specific κ may be printed from it; its sedation context (ketamine infusions in COVID-19 patients) prints with its limb. Distinct from packs #7751 (RASS) and #7823 (SAS): the MAAS is a third, independently derived scale whose categories track motor activity, adapted from the SAS framework; cross-points in prose only, no anchor shared. This is a measurement-properties shelf, not a sedation-treatment shelf.
MeSH: Adult · Drug Monitoring/methods · Female · Humans · Hypnotics and Sedatives/therapeutic use · Intensive Care Units · Linear Models · Male · Middle Aged · Postoperative Care · Psychometrics/methods · Psychomotor Agitation/diagnosis,prevention & control · Reproducibility of Results · Respiration, Artificial/nursing · Analgesics/administration & dosage · Procedural Sedation/classification · Critical Care/standards · Hypnotics and Sedatives/administration & dosage · Motor Activity/drug effects · Nursing Assessment · Practice Guidelines as Topic · Prospective Studies · Reference Standards · COVID-19/therapy,epidemiology · Respiration, Artificial · Ketamine/administration & dosage · SARS-CoV-2/isolation & purification · Iran · Procedural Sedation/methods · Critical Care/methods
Cards (4)
Card 1 — Derivation (Devlin 1999, Critical Care Medicine — prospective psychometric evaluation in 25 mechanically ventilated surgical-ICU patients, 400 paired assessments): MAAS showed a linear trend against the visual-analogue sedation scale, blood-pressure and heart-rate change and agitation-related sequelae (all p <.001), with inter-rater κ 0.83 (95% CI 0.72 to 0.94) against the VAS's ICC of 0.32 — programme-labelled: the Devlin group's own report; TYPE-FLAG: typed Clinical Trial / Randomized Controlled Trial at PubMed although its described design is a prospective psychometric evaluation with no randomised intervention (counted on substance, type-flag printed)
Study: Derivation / psychometric evaluation (primary report) — programme-labelled; TYPE-FLAG: record typed Clinical Trial / Randomized Controlled Trial against a psychometric design
Population: Twenty-five randomly selected, adult, mechanically ventilated, non-neurosurgical patients admitted to a 16-bed surgical ICU of a 937-bed tertiary teaching hospital ≥12 hours after surgery and not receiving neuromuscular blockers. Four hundred assessments (eight per patient) were completed consecutively but independently, in pairs, at standardised times (day and night) by two nurses preselected from a pool of 32 pretrained SICU nurses. Validity paired assessments compared MAAS with a 10-cm visual-analogue sedation scale, percent change in blood pressure and heart rate from 4-hour baselines, and recent agitation-related sequelae; reliability paired assessments correlated MAAS with MAAS. TYPE-FLAG: the record is typed Clinical Trial / Randomized Controlled Trial at PubMed; its abstract describes a prospective psychometric evaluation with no randomised intervention — counted on substance, discrepancy printed.
Summary: Derivation (Devlin 1999, Critical Care Medicine — prospective psychometric evaluation in 25 mechanically ventilated surgical-ICU patients, 400 paired assessments): MAAS showed a linear trend against the visual-analogue sedation scale, blood-pressure and heart-rate change and agitation-related sequelae (all p <.001), with inter-rater κ 0.83 (95% CI 0.72 to 0.94) against the VAS's ICC of 0.32 — programme-labelled: the Devlin group's own report; TYPE-FLAG: typed Clinical Trial / Randomized Controlled Trial at PubMed although its described design is a prospective psychometric evaluation with no randomised intervention (counted on substance, type-flag printed)
Result: Generalised estimating equations, accounting for the four repeated measures in each patient, supported MAAS validity by finding a linear trend between MAAS and the visual-analogue scale (p < .001), blood pressure (p < .001), heart rate (p < .001) and agitation-related sequelae (p < .001) endpoints. The MAAS (kappa = 0.83 [95% confidence interval, 0.72 to 0.94]) was more reliable than subjective assessment using the visual-analogue scale (intraclass correlation coefficient = 0.32 [95% CI 0.05 to 0.55]). The authors conclude the MAAS is a valid and reliable sedation scale for mechanically ventilated patients in the SICU, as published.
Watch out: TYPE-FLAG prints: typed Randomized Controlled Trial at PubMed, described design a prospective psychometric evaluation — counted on substance. The patient N is 25; the 400 assessments are repeated paired measures in those 25 patients and must never be read as 400 patients. The validity criteria are a subjective VAS and physiological correlates (blood pressure, heart rate, sequelae counts) — not a physiological gold standard.
Source: Devlin et al. Motor Activity Assessment Scale: a valid and reliable sedation scale for use with mechanically ventilated patients in an adult surgical intensive care unit. Critical care medicine. 1999. PMID: 10446819. Registry ID: none in the record. MeSH: Adult · Drug Monitoring/methods · Female · Humans · Hypnotics and Sedatives/therapeutic use · Intensive Care Units · Linear Models · Male · Middle Aged · Postoperative Care · Psychometrics/methods · Psychomotor Agitation/diagnosis,prevention & control · Reproducibility of Results · Respiration, Artificial/nursing
Card 2 — Inter-rater reliability study (Hogg 2001, American Journal of Critical Care — 31 ventilated medical-ICU patients rated simultaneously by five raters: three nurses, a pharmacist, a physician): MAAS Pearson r ranged 0.75–0.92 with ICC 0.81, against the Luer scale's 0.37–0.94 / 0.79
Study: Inter-rater reliability study (primary report) — preliminary report, N=31
Population: 31 patients receiving mechanical ventilation in an 18-bed medical intensive care unit of a tertiary care institution; three registered nurses, one clinical pharmacist and one physician simultaneously and independently rated each patient with the Motor Activity Assessment Scale and the Luer sedation scale, in randomised order, following a standardised procedure; analysis of variance for bias, a correlation matrix for association among raters, and the intraclass correlation coefficient for multiple raters.
Summary: Inter-rater reliability study (Hogg 2001, American Journal of Critical Care — 31 ventilated medical-ICU patients rated simultaneously by five raters: three nurses, a pharmacist, a physician): MAAS Pearson r ranged 0.75–0.92 with ICC 0.81, against the Luer scale's 0.37–0.94 / 0.79
Result: No significant bias was detected with either scale. The Motor Activity Assessment Scale had less variation (Pearson r = 0.75–0.92) than the Luer scale (Pearson r = 0.37–0.94) and a stronger intraclass correlation coefficient (0.81 versus 0.79). The authors conclude the MAAS showed the highest consistency among raters, as published.
Watch out: A preliminary report on 31 patients with five simultaneous raters — a best-case rating design (same moment, standardised procedure) that flatters agreement relative to routine serial charting. The ICC advantage over the Luer scale is small (0.81 versus 0.79); the consistency advantage is in the narrower correlation range.
Source: Hogg et al. Interrater reliability of 2 sedation scales in a medical intensive care unit: a preliminary report. American journal of critical care : an official publication, American Association of Critical-Care Nurses. 2001. PMID: 11244675. Registry ID: none in the record. MeSH: Analgesics/administration & dosage · Procedural Sedation/classification · Critical Care/standards · Humans · Hypnotics and Sedatives/administration & dosage · Intensive Care Units · Motor Activity/drug effects · Nursing Assessment · Practice Guidelines as Topic · Prospective Studies · Reference Standards · Reproducibility of Results
Card 3 — Four-scale COVID-era evaluation (Al-Taie 2025, Scientific Reports — 73 mechanically ventilated COVID-19 ICU patients on ketamine sedation): inter-rater κ across the four scales (Riker SAS, MAAS, RASS, Ramsay) ranged 0.71–0.89 with no significant score differences between raters or scales — labelled a multi-scale study: its κ range is the family figure and no MAAS-specific κ may be printed from it
Study: Multi-scale evaluation (primary report) — MAAS one of four scales; no MAAS-specific κ printed
Population: Seventy-three mechanically ventilated COVID-19 patients sedated with intravenous ketamine (10–20 µg/kg/min) at a single hospital ICU in Zahedan, Iran, in 2022–2023 (mean age 56.5 ± 14.1 years; 67.1% male). Four sedation scales were applied: the Riker Sedation-Agitation Scale, the Motor Activity Assessment Scale, the Richmond Agitation-Sedation Scale and the Ramsay Sedation Scale; primary outcome inter-rater reliability (Cohen kappa); criterion validity examined across demographic and clinical variables.
Summary: Four-scale COVID-era evaluation (Al-Taie 2025, Scientific Reports — 73 mechanically ventilated COVID-19 ICU patients on ketamine sedation): inter-rater κ across the four scales (Riker SAS, MAAS, RASS, Ramsay) ranged 0.71–0.89 with no significant score differences between raters or scales — labelled a multi-scale study: its κ range is the family figure and no MAAS-specific κ may be printed from it
Result: The Friedman test showed no significant differences in sedation scores among raters or scales (p-values: Riker SAS 0.89, MAAS 0.67, RASS 0.76, Ramsay 0.81). Inter-rater reliability was high across all scales, with kappa coefficients ranging from 0.71 to 0.89 — a range across the four scales, printed as the family figure. Criterion validity analysis indicated no significant differences in sedation scores by age, gender, ICU stay duration or comorbidities (all p > 0.05), as published.
Watch out: Multi-scale study: the 0.71–0.89 κ range spans four scales and two-plus raters; assigning any single value in it to the MAAS would invent a figure. The context is narrow — COVID-19 patients on ketamine infusions in one centre — and prints with the limb.
Source: Al-Taie et al. Evaluation of different sedation scales in the ICU management of COVID-19 patients. Scientific reports. 2025. PMID: 40770409. Registry ID: none in the record. MeSH: Humans · Male · Female · COVID-19/therapy,epidemiology · Middle Aged · Intensive Care Units · Adult · Aged · Respiration, Artificial · Hypnotics and Sedatives/administration & dosage · Reproducibility of Results · Ketamine/administration & dosage · SARS-CoV-2/isolation & purification · Iran · Procedural Sedation/methods · Critical Care/methods
Card 4 — Synthesis (3 reports — 1 derivation + 1 inter-rater study + 1 multi-scale evaluation; TYPE-FLAG on the derivation ): MAAS inter-rater reliability is consistently high in small ICU samples (κ 0.83 at derivation in 25 patients; ICC 0.81 across five mixed raters in 31 patients), but the entire shelf rests on 129 patients, and criterion validity is against a subjective VAS and physiological correlates, not a standard
Study: Synthesis
Population: Synthesis of the 3 reports carded above: the derivation (25 surgical-ICU patients, 400 paired assessments), the inter-rater study (31 medical-ICU patients, 5 raters) and the four-scale COVID-era evaluation (73 patients, MAAS one of four scales). Total patients across reports: 129.
Summary: Synthesis (3 reports — 1 derivation + 1 inter-rater study + 1 multi-scale evaluation; TYPE-FLAG on the derivation ): MAAS inter-rater reliability is consistently high in small ICU samples (κ 0.83 at derivation in 25 patients; ICC 0.81 across five mixed raters in 31 patients), but the entire shelf rests on 129 patients, and criterion validity is against a subjective VAS and physiological correlates, not a standard
Result: Reliability: derivation inter-rater κ 0.83 (0.72 to 0.94), clearly above the comparator VAS's ICC 0.32; mixed-rater ICC 0.81 with Pearson r 0.75–0.92; and a four-scale κ range of 0.71–0.89 in the COVID-era study (family figure only). Validity: at derivation, linear trends against the VAS, blood-pressure and heart-rate change and agitation-related sequelae (all p < .001) — convergent evidence against subjective and physiological correlates. No report tests whether MAAS-guided sedation changes patient outcomes.
Watch out: TYPE-FLAG restated: the derivation anchor is typed Randomized Controlled Trial at PubMed against a prospective psychometric design; it is counted on substance with the flag printed on its card, in the balance and here. Small samples throughout (25 / 31 / 73 patients) — reliability established in these settings is not accuracy established for every ICU population, and no outcome benefit of MAAS use is shown anywhere on this shelf.
Source: Synthesis of the reports carded above; no additional source.