SourceMed · Shelf #8111 in the ask interface
Repetitive Saliva Swallowing Test: modest standalone discrimination (AUC 0.64); cut-off migrates from <3 to ≤6 because the healthy mean is ~7 — 3 reports
Shelf #8111 · Brain, stroke & mind
PREDICTIVE PERFORMANCE — MODEST, cut-off spectrum-dependent: AUC 0.64 against FEES airway invasion with sensitivity 89% / specificity 34% at ≤6 swallows (n = 87 clinic patients), against an established pathological cut-off of <3 and a healthy mean of 7.01 ± 2.86 (n = 280); composition 1 dedicated accuracy study + 1 normative study + 1 multi-test component report; a screening-performance stamp, not a dysphagia-treatment stamp
Stamped: 2026-11-28.
Evidence published: 2021–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How well does the Repetitive Saliva Swallowing Test (RSST — the patient performs as many dry (saliva) swallows as possible in 30 seconds, counted by laryngeal palpation / observation; the established pathological cut-off is fewer than 3) screen for oropharyngeal dysphagia and airway invasion — what accuracy did it show against endoscopic evaluation in an all-cause dysphagia clinic population and at what cut-off, what are its normative values in healthy adults and what moves them, and how did it fare inside a multi-test screening battery after head-and-neck cancer resection?
Balance of the evidence
This is a screening-accuracy / measurement shelf. Composition on the face: 1 dedicated accuracy study + 1 normative study + 1 multi-test component report — printed here and on every card it governs. The cut-off migrates threefold (the established pathological cut-off of fewer than 3 swallows vs the clinic study's optimal ≤6) because the healthy mean itself is about 7: a cut-off of 6 in a dysphagia clinic and a cut-off of 3 from the original validation answer different spectra and never merge. Specificity at the clinic cut-off is 34% and prints beside the 89% sensitivity. The normative dataset is a healthy-volunteer distribution and no accuracy figure may be drawn from it. The multi-test report is carded for its RSST limb as a component report: no RSST-specific accuracy pair is printed in its abstract and none is printed from it. The original RSST validation (Oguchi, 2000) was not returned by the mining desk's searches and is NOT carded. Distinct from the water-swallow-based screens #7786 (Yale) and #7817 (TOR-BSST) and from the volume-viscosity test: the RSST involves no bolus at all; the swallow rows cross-point.
MeSH: Humans · Deglutition Disorders/diagnosis,etiology,physiopathology · Retrospective Studies · Male · Female · Middle Aged · Aged · Deglutition/physiology · Saliva · Predictive Value of Tests · Adult · Aged, 80 and over · Sensitivity and Specificity · ROC Curve · Respiratory Aspiration/diagnosis,etiology · Cross-Sectional Studies · Reference Values · Young Adult · Saliva/chemistry · Deglutition Disorders/diagnosis,physiopathology · Body Mass Index · Healthy Volunteers · Sex Factors · Deglutition Disorders/diagnosis · Early Detection of Cancer · Head and Neck Neoplasms/diagnosis · Mass Screening/methods
Cards (4)
Card 1 — Dedicated accuracy study (Kiderman 2025, The Laryngoscope — retrospective review of 87 adult dysphagia-clinic outpatients with both RSST and FEES): against FEES airway invasion (penetration-aspiration scale ≥3, present in 32%) the RSST's AUC was 0.64, and at the optimal cut-off of ≤6 swallows sensitivity was 89% and specificity 34%
Study: Diagnostic-accuracy study (primary report) — retrospective
Population: 87 adult outpatients from a dysphagia clinic, each undergoing both the RSST and fiberoptic endoscopic evaluation of swallowing (FEES); the primary outcome was FEES-determined airway invasion (PAS ≥3), present in 32% of the cohort; median RSST score was 5.
Summary: Dedicated accuracy study (Kiderman 2025, The Laryngoscope — retrospective review of 87 adult dysphagia-clinic outpatients with both RSST and FEES): against FEES airway invasion (penetration-aspiration scale ≥3, present in 32%) the RSST's AUC was 0.64, and at the optimal cut-off of ≤6 swallows sensitivity was 89% and specificity 34%
Result: Higher RSST scores were associated with a lower likelihood of airway invasion (odds ratio 0.79 per swallow, labelled as such, p = 0.03). On ROC analysis the RSST had an AUC of 0.64, with an optimal cut-off of ≤6 swallows yielding 89% sensitivity and 34% specificity. The authors conclude the RSST is statistically compatible with airway-invasion screening in an all-cause dysphagia population, but its high cut-off values hinder clinical utility because of modest specificity, as published.
Watch out: The 89% sensitivity is bought with 34% specificity at a cut-off (≤6) far above the established pathological cut-off (<3): most clinic patients screening positive do not have airway invasion. Retrospective, single-clinic spectrum.
Source: Kiderman et al. Can the Repetitive Saliva Swallow Test Predict Airway Invasion in All Cause Dysphagia?. The Laryngoscope. 2025. PMID: 40130445. Registry ID: none in the record. MeSH: Humans · Deglutition Disorders/diagnosis,etiology,physiopathology · Retrospective Studies · Male · Female · Middle Aged · Aged · Deglutition/physiology · Saliva · Predictive Value of Tests · Adult · Aged, 80 and over · Sensitivity and Specificity · ROC Curve · Respiratory Aspiration/diagnosis,etiology
Card 2 — Normative-values study (Ben-Hayoun 2024, Dysphagia — 280 healthy adults recruited equally by sex across decades 20–90 years): mean RSST 7.01 ± 2.86, lower with age (r = −0.463), higher BMI, more comorbidities and more medications, and higher in men (7.6 vs 6.47), with mean scores in every age group remaining above the pathological cut-off of 3
Study: Normative-values study (primary report)
Population: 280 healthy adults, an equal number of females and males recruited for each decade of life from 20 to 90 years; people reporting swallowing difficulties, neurological disorders, or head-and-neck surgery / radiation were excluded. Data included RSST scores, comorbidities, prescribed medications, BMI, smoking and a xerostomia self-assessment.
Summary: Normative-values study (Ben-Hayoun 2024, Dysphagia — 280 healthy adults recruited equally by sex across decades 20–90 years): mean RSST 7.01 ± 2.86, lower with age (r = −0.463), higher BMI, more comorbidities and more medications, and higher in men (7.6 vs 6.47), with mean scores in every age group remaining above the pathological cut-off of 3
Result: The mean RSST score was 7.01 ± 2.86. Males scored higher than females (7.6 ± 3.04 vs 6.47 ± 2.56, p = 0.001). Age correlated inversely with RSST scores (Pearson r = −0.463, p < 0.0001), as did BMI (r = −0.2), number of comorbidities (r = −0.344) and number of prescribed medications (r = −0.425). On multivariate analysis age, sex, BMI and number of medications were significant independent factors. Mean RSST for all age groups did not fall beneath the previously established pathological cut-off, as published.
Watch out: A healthy-volunteer distribution: no accuracy figure may be drawn from it. Its mean of about 7 is exactly why the clinic study's optimal cut-off rose to ≤6 — the two reports' cut-offs answer different spectra and never merge.
Source: Ben-Hayoun et al. Normative Values of the Repetitive Saliva Swallow Test and Clinical Factors Affecting the Test Scores in Healthy Adults. Dysphagia. 2024. PMID: 38847841. Registry ID: none in the record. MeSH: Humans · Male · Female · Adult · Middle Aged · Aged · Cross-Sectional Studies · Aged, 80 and over · Reference Values · Deglutition/physiology · Young Adult · Saliva/chemistry · Deglutition Disorders/diagnosis,physiopathology · Body Mass Index · Healthy Volunteers · Sex Factors
Card 3 — Multi-test validity study (Horii 2021, Irish journal of medical science — 36 patients after head-and-neck cancer resection against videofluoroscopy): the battery's modified water swallowing test and food test carried the accuracy (AUC 0.76 / 0.80) and their combination reached 0.87, while the RSST was one of five component tests — carded for its RSST limb as a component report: no RSST-specific accuracy pair is printed in its abstract and none may be printed from it
Study: Multi-test screening-battery study (primary report) — RSST component limb only, labelled
Population: 36 patients who had undergone resection for head-and-neck cancer; the screening battery comprised the RSST, the water swallowing test, the modified water swallowing test (MWST), the food test (FT) and tongue pressure, against a videofluoroscopic swallowing study scored with the penetration-aspiration scale.
Summary: Multi-test validity study (Horii 2021, Irish journal of medical science — 36 patients after head-and-neck cancer resection against videofluoroscopy): the battery's modified water swallowing test and food test carried the accuracy (AUC 0.76 / 0.80) and their combination reached 0.87, while the RSST was one of five component tests — carded for its RSST limb as a component report: no RSST-specific accuracy pair is printed in its abstract and none may be printed from it
Result: Penetration / aspiration could be predicted with moderate accuracy by the MWST and the FT (AUC 0.76, p = 0.03, sensitivity / specificity 0.9 / 0.61; and AUC 0.80, p = 0.050, sensitivity / specificity 0.8 / 0.8, respectively). Combining tests, the MWST + FT combination was the most accurate (AUC 0.87, p = 0.02); combining three tests was less accurate than combining two. The authors recommend the MWST or FT alone, or the two combined, as published. The RSST was a component of the battery; no RSST-specific accuracy figure is reported in the abstract.
Watch out: Component-report discipline: this card evidences the RSST's place inside a five-test battery, not RSST accuracy — the battery's accuracy belonged to the water and food tests. Small N (36) prints.
Source: Horii et al. Validity of a dysphagia screening test following resection for head and neck cancer. Irish journal of medical science. 2021. PMID: 32607911. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Deglutition Disorders/diagnosis · Early Detection of Cancer · Female · Head and Neck Neoplasms/diagnosis · Humans · Male · Mass Screening/methods · Middle Aged
Card 4 — Synthesis (1 dedicated accuracy study + 1 normative study + 1 multi-test component report; the original validation is not carded): as a standalone screen the RSST's discrimination is modest (AUC 0.64) and its operating cut-off is spectrum-dependent — <3 established, ≤6 optimal in a dysphagia clinic where the healthy mean is about 7
Study: Synthesis
Population: Synthesis of the 3 reports carded above (dedicated accuracy study n = 87; normative study n = 280; multi-test battery study n = 36 — RSST component limb only). The original RSST validation (Oguchi, 2000) is not among them.
Summary: Synthesis (1 dedicated accuracy study + 1 normative study + 1 multi-test component report; the original validation is not carded): as a standalone screen the RSST's discrimination is modest (AUC 0.64) and its operating cut-off is spectrum-dependent — <3 established, ≤6 optimal in a dysphagia clinic where the healthy mean is about 7
Result: Against FEES airway invasion in an all-cause dysphagia clinic, the RSST reached AUC 0.64 with sensitivity 89% at specificity 34% at ≤6 swallows. In healthy adults the mean count was 7.01 ± 2.86, falling with age and differing by sex, BMI, comorbidity and medication count, yet staying above the established pathological cut-off of 3 in every decade. Inside a five-test post-resection battery, the accuracy was carried by the modified water swallowing test and the food test (combined AUC 0.87), not by any RSST-specific figure.
Watch out: Composition restated: only one report measures RSST accuracy directly. A 'positive' RSST means different things at cut-off 3 and cut-off 6 — the cut-off and its spectrum print with every figure.
Source: Synthesis of the reports carded above; no additional source.