Single self-report hearing question: moderate population-level accuracy (sensitivity ~71–82% by wording; AUC 0.70 mild vs 0.86 moderate loss) — never a rule-out — 3 reports
Shelf #8115 · Eyes, skin, nose & allergy
SCREENING ACCURACY — moderate, wording- and severity-dependent: 'Do you feel you have a hearing loss?' sensitivity 71% in a population sample (n = 3,556) and 79.6% / 77.4% in a Brazilian cohort (n = 188, three phrasings spanning 66.9–81.5% sensitivity); Rotterdam difficulty question AUC 0.70 for mild-or-worse (≥20 dB) vs 0.86 for moderate-or-worse (≥35 dB) loss (n = 4,906); composition 3 reports; cross-points #8114 and #7813; a screening-accuracy stamp — a 'no' answer does not exclude hearing loss
Stamped: 2026-11-28.
Evidence published: 1998–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does a single self-report hearing question ("Do you feel you have a hearing loss?" and its variants) identify audiometric hearing loss in adults — what did the Beaver Dam population study find for the single question against the HHIE-S, what sensitivity / specificity did the Brazilian study find for three single questions, and how well does the Rotterdam Study's difficulty question classify mild and moderate hearing loss?
Balance of the evidence
This is a screening-accuracy shelf for epidemiological / first-step use. Question wording is part of the instrument: the three Brazilian questions differ by about 15 points of sensitivity, and each pair prints with its question verbatim. Severity definition moves the AUC (0.70 for mild-or-worse vs 0.86 for moderate-or-worse loss in Rotterdam) and prints. A single question's sensitivity (about 71–82%) means roughly a fifth to a third of audiometric loss is missed — no card may present a 'no' answer as excluding hearing loss. PMID 9776206 anchors THIS shelf only: its HHIE-S limb is a comparator here; the HHIE-S's own shelf is #8114, on different reports — neither report is an anchor on both packs. PMID 22833152 (the Japanese head-to-head) anchors #8114 only and is not carded here. The three hearing rows cross-point: this shelf, #8114 (HHIE-S) and pack #7813 (whispered voice test — an administered manoeuvre).
MeSH: Adult · Aged · Aged, 80 and over · Female · Hearing Aids · Hearing Loss/diagnosis,epidemiology,rehabilitation · Hearing Loss, Conductive/diagnosis,epidemiology,rehabilitation · Humans · Male · Middle Aged · Predictive Value of Tests · Prevalence · Surveys and Questionnaires · Age Factors · Audiometry, Pure-Tone · Diagnostic Self Evaluation · Hearing Loss/diagnosis · Reproducibility of Results · Sensitivity and Specificity · Sex Factors · Age Distribution · Area Under Curve · Audiometry, Pure-Tone/methods · Cohort Studies · Early Diagnosis · Regression Analysis · Self Report
Cards (4)
Card 1 — Beaver Dam population study (Nondahl 1998, Audiology : official organ of the International Society of Audiology — 3,556 adults aged 48–92): the single question 'Do you feel you have a hearing loss?' was the most sensitive single item (sensitivity 71%) and its prevalence estimates sat within 3.2% of audiometric prevalence, while an HHIE-S total >8 had sensitivity of only 34% in this population spectrum — its HHIE-S limb prints as a comparator; the HHIE-S's own row is #8114, on different reports; this report anchors #8115 only
Study: Population accuracy study (primary report) — anchors this shelf only; HHIE-S limb comparator-only here
Population: 3,556 study participants aged 48–92 years examined in a population-based study of age-related hearing loss in Beaver Dam, Wisconsin; self-report data from the ten-question HHIE-S and four additional questions were compared with hearing loss measured by pure-tone air-conduction audiometry.
Summary: Beaver Dam population study (Nondahl 1998, Audiology : official organ of the International Society of Audiology — 3,556 adults aged 48–92): the single question 'Do you feel you have a hearing loss?' was the most sensitive single item (sensitivity 71%) and its prevalence estimates sat within 3.2% of audiometric prevalence, while an HHIE-S total >8 had sensitivity of only 34% in this population spectrum — its HHIE-S limb prints as a comparator; the HHIE-S's own row is #8114, on different reports; this report anchors #8115 only
Result: The single question 'Do you feel you have a hearing loss?' was the most sensitive question (sensitivity 71%); its overall and gender-specific prevalence estimates were within 3.2% of prevalence measures derived audiometrically, although age-group-specific estimates were not as accurate. Using an HHIE-S total score >8 resulted in low sensitivity (34%) and inaccurate prevalence estimates. The authors conclude that, for some applications, one simple question may be sufficient for prevalence surveys of hearing loss among older adults, as published.
Watch out: Anchor discipline: this report is carded here for its single-question limb; its HHIE-S limb is comparator-only on this shelf and it is not an anchor on #8114. Sensitivity 71% still misses 29% of audiometric loss — a 'no' answer does not exclude hearing loss. Age-group prevalence estimates were less accurate than the overall figure.
Source: Nondahl et al. Accuracy of self-reported hearing loss. Audiology : official organ of the International Society of Audiology. 1998. PMID: 9776206. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Hearing Aids · Hearing Loss/diagnosis,epidemiology,rehabilitation · Hearing Loss, Conductive/diagnosis,epidemiology,rehabilitation · Humans · Male · Middle Aged · Predictive Value of Tests · Prevalence · Surveys and Questionnaires
Card 2 — Brazilian validity study (Ferrite 2011, Revista de saude publica — random subsample of 188 adults aged 30–65 from a population cohort in Salvador): three single questions gave sensitivity / specificity of 79.6% / 77.4% ('Do you feel you have a hearing loss?'), 66.9% / 85.1% (global hearing rating) and 81.5% / 76.4% (change-from-before question), with Youden indices 51.9–57.9%
Study: Validity study (primary report)
Population: A random subsample of 188 subjects aged 30 to 65 years drawn from the fourth wave of a population-based cohort study in Salvador, Northeastern Brazil; data collected at household visits, with responses to each of three questions compared against pure-tone audiometry.
Summary: Brazilian validity study (Ferrite 2011, Revista de saude publica — random subsample of 188 adults aged 30–65 from a population cohort in Salvador): three single questions gave sensitivity / specificity of 79.6% / 77.4% ('Do you feel you have a hearing loss?'), 66.9% / 85.1% (global hearing rating) and 81.5% / 76.4% (change-from-before question), with Youden indices 51.9–57.9%
Result: The three questions were: Q1, 'Do you feel you have a hearing loss?'; Q2, a global rating ('excellent' to 'poor'); Q3, a change-from-before question. Estimated sensitivity and specificity were 79.6% / 77.4% for Q1, 66.9% / 85.1% for Q2 and 81.5% / 76.4% for Q3. The Youden index ranged from 51.9% (Q2) to 57.0% (Q1) and 57.9% (Q3). The authors conclude each question is accurate enough to assess self-reported hearing loss in epidemiological studies when pure-tone audiometry is not feasible, as published.
Watch out: Wording is the instrument: sensitivity spans 66.9–81.5% across three phrasings in the same people — no pair may be quoted without its question. A younger spectrum (30–65 years) than the older-adult rows around it; pairs do not transfer unchanged to elderly clinic populations.
Source: Ferrite et al. Validity of self-reported hearing loss in adults: performance of three single questions. Revista de saude publica. 2011. PMID: 21808834. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Audiometry, Pure-Tone · Diagnostic Self Evaluation · Female · Hearing Loss/diagnosis · Humans · Male · Middle Aged · Predictive Value of Tests · Reproducibility of Results · Sensitivity and Specificity · Sex Factors · Surveys and Questionnaires
Card 3 — Rotterdam Study (Oosterloo 2020, PloS one — 4,906 participants): the multiple-choice difficulty question's AUC was 0.70 (95% CI 0.68 to 0.71) for mild-or-worse loss (≥20 dB) and 0.86 (0.85 to 0.87) for moderate-or-worse (≥35 dB), rising to 0.73 / 0.90 when age, sex and education were added
Study: Population cohort accuracy analysis (primary report)
Population: 4,906 participants of the Rotterdam Study; the question investigated (in Dutch) was 'Do you have any difficulty with your hearing (without hearing aids)?' with answers 'never', 'sometimes', 'often' and 'daily'. Mild hearing loss or worse was defined as pure-tone average (0.5–4 kHz) ≥20 dB HL and moderate or worse as ≥35 dB HL.
Summary: Rotterdam Study (Oosterloo 2020, PloS one — 4,906 participants): the multiple-choice difficulty question's AUC was 0.70 (95% CI 0.68 to 0.71) for mild-or-worse loss (≥20 dB) and 0.86 (0.85 to 0.87) for moderate-or-worse (≥35 dB), rising to 0.73 / 0.90 when age, sex and education were added
Result: The variance in pure-tone average explained by the question alone was R² 0.37, rising to 0.60 when age was added (sex and education did not materially change it, 0.61). The question's ability to classify hearing loss, as AUC, was 0.70 (95% CI 0.68 to 0.71) for mild hearing loss or worse and 0.86 (95% CI 0.85 to 0.87) for moderate or worse; with sex, education and age taken into account the AUCs rose to 0.73 (0.71 to 0.75) and 0.90 (0.89 to 0.91) respectively. The authors conclude a single question has good ability to detect hearing loss in older adults, especially when age is accounted for, but cannot substitute for audiometry, as published.
Watch out: Severity prints: the same question is a weak classifier of mild loss (AUC 0.70) and a good classifier of moderate loss (AUC 0.86) — and part of the improved figures belongs to age, not to the question (R² 0.37 alone vs 0.60 with age). A multiple-choice difficulty question, not the yes/no form of the other two cards.
Source: Oosterloo et al. Assessing hearing loss in older adults with a single question and person characteristics; Comparison with pure tone audiometry in the Rotterdam Study. PloS one. 2020. PMID: 31986178. Registry ID: none in the record. MeSH: Age Distribution · Aged · Aged, 80 and over · Area Under Curve · Audiometry, Pure-Tone/methods · Cohort Studies · Early Diagnosis · Female · Hearing Loss/diagnosis · Humans · Male · Middle Aged · Regression Analysis · Self Report
Card 4 — Synthesis (3 reports): a single hearing question classifies audiometric loss moderately — sensitivity about 71–82% depending on wording, AUC 0.70 for mild loss rising to 0.86 for moderate loss — adequate for population estimation and first-step triage, never a rule-out; cross-points #8114 and #7813
Study: Synthesis
Population: Synthesis of the 3 reports carded above (Beaver Dam population study n = 3,556; Brazilian validity study n = 188; Rotterdam Study n = 4,906). Cross-points: the HHIE-S is shelved at #8114 and the whispered voice test at pack #7813; PMID 9776206 is an anchor here only, its HHIE-S limb comparator-only.
Summary: Synthesis (3 reports): a single hearing question classifies audiometric loss moderately — sensitivity about 71–82% depending on wording, AUC 0.70 for mild loss rising to 0.86 for moderate loss — adequate for population estimation and first-step triage, never a rule-out; cross-points #8114 and #7813
Result: The yes/no question 'Do you feel you have a hearing loss?' reached sensitivity 71% in a population sample (with prevalence estimates within 3.2% of audiometry) and 79.6% / 77.4% in a Brazilian cohort, where two alternative phrasings traded sensitivity for specificity (66.9% / 85.1% and 81.5% / 76.4%). The Rotterdam multiple-choice difficulty question classified moderate-or-worse loss well (AUC 0.86) but mild loss weakly (AUC 0.70), improving when age was added. In the Beaver Dam spectrum the single question outperformed the HHIE-S at its conventional cut-off (sensitivity 71% vs 34%).
Watch out: Roughly a fifth to a third of audiometric loss answers 'no': the question estimates prevalence and opens the door to audiometry — it does not exclude hearing loss in an individual.
Source: Synthesis of the reports carded above; no additional source.