M-CHARTS: quantitative metamorphopsia scores in established macular disease — validated against questionnaires and subjective perception, independent of visual acuity — 4 reports

Shelf #8116 · Eyes, skin, nose & allergy

MEASUREMENT PROPERTIES — quantification of metamorphopsia in established macular disease supported: α 0.934 and AUC 0.801 at score ≥0.2 against questionnaire-defined metamorphopsia after detachment repair (n = 100); detection 89% vs Amsler 69% in wet AMD; sensitivities above PHP's against subjective perception (89% vs 42% epiretinal membrane); scores independent of visual acuity; composition 4 reports; NOT a screening / home-detection stamp

Stamped: 2026-11-28.

Evidence published: 2011–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How well do M-CHARTS (the metamorphopsia charts — dotted lines of increasing dot spacing presented horizontally and vertically; the score is the minimum visual angle at which the distortion disappears, separately for horizontal and vertical metamorphopsia) quantify metamorphopsia in macular disease — what sensitivity / specificity and questionnaire correlation did the retinal-detachment validation find, how do its scores behave around macular-hole surgery, how did it compare with the Amsler grid for detecting metamorphopsia in wet AMD, and how did it compare with preferential hyperacuity perimetry against patients' subjective perception?

Balance of the evidence

This is a quantification / measurement shelf, not a screening shelf for neovascular AMD — no card may present M-CHARTS as a home detection test on this evidence (the home-monitoring instrument in this family is preferential hyperacuity perimetry, whose standalone evidence sits below the floor and which appears here only as a comparator limb). Reference standards differ across the four reports (questionnaire-defined metamorphopsia in two, subjective perception in one, pre/post surgical change in one) and print with each figure. Horizontal and vertical scores are separate measurements with different time courses and print separately. M-CHARTS scores' independence from visual acuity is a repeated finding (two anchors) and prints as such. Distinct from pack #7978 (Amsler grid — a binary self-report detection test for neovascular AMD; M-CHARTS quantify distortion in established macular disease, and the AMD anchor's Amsler limb prints as a comparator) and pack #7088 (contrast sensitivity — a different visual function, PHYS distribution home); the vision rows cross-point.

MeSH: Humans · Retinal Detachment/surgery,diagnosis,physiopathology · Female · Prospective Studies · Male · Middle Aged · Visual Acuity/physiology · Vision Disorders/diagnosis,physiopathology · Aged · Reproducibility of Results · Surveys and Questionnaires · Adult · ROC Curve · Vision Tests · Vitrectomy · Aged, 80 and over · Angiogenesis Inhibitors/administration & dosage · Antibodies, Monoclonal, Humanized/administration & dosage · Bevacizumab · Case-Control Studies · Intravitreal Injections · Tomography, Optical Coherence · Vision Disorders/diagnosis · Vision Tests/instrumentation · Visual Acuity · Wet Macular Degeneration/diagnosis,drug therapy · Epiretinal Membrane/diagnosis · Macular Degeneration/diagnosis · Retinal Diseases/diagnosis · Retinal Perforations/diagnosis · Sensitivity and Specificity · Sickness Impact Profile · Visual Perception

Cards (5)

Card 1 — Retinal-detachment validation (Oquendo 2024, Retina (Philadelphia, Pa.) — 100 subjects, 50 patients after rhegmatogenous retinal detachment repair and 50 controls): total M-CHARTS α 0.934, scores correlated with the modified metamorphopsia questionnaire (ρ 0.405–0.475), and at a positive score of ≥0.2 sensitivity for metamorphopsia was 72.7% and specificity 94.6% (AUC 0.801) against questionnaire-defined metamorphopsia

Study: Validation study (primary report) — reference standard is questionnaire-defined metamorphopsia

Population: 100 patients in a prospective observational study at a Toronto hospital: 50 with primary unilateral rhegmatogenous retinal detachment and 50 healthy controls; metamorphopsia at three months was assessed with the modified metamorphopsia questionnaire (MeMoQ) and M-CHARTS.

Summary: Retinal-detachment validation (Oquendo 2024, Retina (Philadelphia, Pa.) — 100 subjects, 50 patients after rhegmatogenous retinal detachment repair and 50 controls): total M-CHARTS α 0.934, scores correlated with the modified metamorphopsia questionnaire (ρ 0.405–0.475), and at a positive score of ≥0.2 sensitivity for metamorphopsia was 72.7% and specificity 94.6% (AUC 0.801) against questionnaire-defined metamorphopsia

Result: Seventy percent (35/50) of the detachment group had metamorphopsia with M-CHARTS and 80% (40/50) with the MeMoQ; both scores were significantly higher in patients than controls (p < 0.0001). Cronbach's alpha was 0.934. Horizontal, vertical and total M-CHARTS scores correlated significantly with MeMoQ scores (ρ = 0.465, 0.405 and 0.475 respectively). M-CHARTS was 72.7% sensitive and 94.6% specific for detection of metamorphopsia (positive score ≥0.2), with an AUC of 0.801. The authors conclude M-CHARTS is validated as a tool to quantitatively assess metamorphopsia after detachment repair, as published.

Watch out: The reference standard is another questionnaire (the modified MeMoQ), not an objective distortion measurement: sensitivity / specificity here mean agreement with patient-reported metamorphopsia at a ≥0.2 threshold, in a post-surgical spectrum.

Source: Oquendo et al. VALIDATION OF M-CHARTS FOR QUANTITATIVE ASSESSMENT OF METAMORPHOPSIA FOLLOWING RHEGMATOGENOUS RETINAL DETACHMENT REPAIR. Retina (Philadelphia, Pa.). 2024. PMID: 38354405. Registry ID: none in the record. MeSH: Humans · Retinal Detachment/surgery,diagnosis,physiopathology · Female · Prospective Studies · Male · Middle Aged · Visual Acuity/physiology · Vision Disorders/diagnosis,physiopathology · Aged · Reproducibility of Results · Surveys and Questionnaires · Adult · ROC Curve · Vision Tests · Vitrectomy

Card 2 — Macular-hole quantification (Wada 2017, Clinical ophthalmology (Auckland, N.Z.) — 22 eyes with idiopathic macular hole before / after vitrectomy): vertical scores exceeded horizontal before surgery and both improved after (vertical from 1 month, horizontal at 6 months), with no correlation between M-CHARTS scores and visual acuity at any assessment — small N (22 eyes) prints on the face

Study: Pre/post surgical quantification study (primary report) — small N prints

Population: Records of 22 eyes of 22 patients with a full-thickness idiopathic macular hole who underwent pars plana vitrectomy with internal limiting membrane peeling; horizontal and vertical metamorphopsia scores were measured with M-CHARTS alongside best-corrected visual acuity and OCT parameters.

Summary: Macular-hole quantification (Wada 2017, Clinical ophthalmology (Auckland, N.Z.) — 22 eyes with idiopathic macular hole before / after vitrectomy): vertical scores exceeded horizontal before surgery and both improved after (vertical from 1 month, horizontal at 6 months), with no correlation between M-CHARTS scores and visual acuity at any assessment — small N (22 eyes) prints on the face

Result: The macular hole sealed in all eyes after surgery and visual acuity improved significantly from one month (p < 0.001). The vertical metamorphopsia score was significantly higher than the horizontal score before surgery (p < 0.05) and improved significantly from one month after surgery (p < 0.03); the horizontal score improved significantly at six months (p < 0.001). Vertical and horizontal scores correlated significantly with each other at all follow-ups. There was no significant correlation between visual acuity and either metamorphopsia score at any follow-up assessment. The authors conclude metamorphopsia scores are an independent treatment outcome in addition to visual acuity, as published.

Watch out: Small N prints: 22 eyes, single-centre records review, no comparator arm — the improvements are within-patient change after successful surgery, not a treatment comparison. This record carries no MeSH terms (printed as none in the record on its source line). Horizontal and vertical scores recover on different clocks (1 vs 6 months) and print separately.

Source: Wada et al. Quantifying metamorphopsia with M-CHARTS in patients with idiopathic macular hole. Clinical ophthalmology (Auckland, N.Z.). 2017. PMID: 29033537. Registry ID: none in the record. MeSH: none in the record

Card 3 — Wet AMD quantification (Nowomiejska 2013, BMC ophthalmology — 36 patients with wet AMD around bevacizumab injection, 23 healthy controls): metamorphopsia detection was 89% with M-CHARTS vs 69% with the Amsler grid, specificity 100% for both in controls, and metamorphopsia degree correlated with neither visual acuity nor central retinal thickness

Study: Quantification / comparison study (primary report) — Amsler limb is a comparator

Population: 36 patients diagnosed with wet age-related macular degeneration, examined one day before and one month after intravitreal bevacizumab injection (M-CHARTS horizontal and vertical scores, distance visual acuity, Amsler test and OCT at each visit), plus 23 healthy subjects examined as a control group.

Summary: Wet AMD quantification (Nowomiejska 2013, BMC ophthalmology — 36 patients with wet AMD around bevacizumab injection, 23 healthy controls): metamorphopsia detection was 89% with M-CHARTS vs 69% with the Amsler grid, specificity 100% for both in controls, and metamorphopsia degree correlated with neither visual acuity nor central retinal thickness

Result: The rate of metamorphopsia detection was 89% with M-CHARTS and 69% with the Amsler test. The horizontal metamorphopsia score improved in 22 patients and the vertical score in 16 after injection; Amsler grid results improved in 6 and visual acuity in 17. There was no correlation between the degree of metamorphopsia and visual acuity or central retinal thickness. The specificity of both M-CHARTS and the Amsler grid was 100% in controls. The authors conclude M-CHARTS detect metamorphopsia better than the Amsler grid and provide information independent of visual acuity and retinal thickness, as published.

Watch out: Detection rates in established wet AMD, not screening performance in undiagnosed disease: the 89% vs 69% comparison quantifies distortion in known macular disease. The Amsler grid is homed at pack #7978; its limb here is comparator-only. Specificity of 100% rests on 23 healthy controls.

Source: Nowomiejska et al. M-charts as a tool for quantifying metamorphopsia in age-related macular degeneration treated with the bevacizumab injections. BMC ophthalmology. 2013. PMID: 23587218. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Angiogenesis Inhibitors/administration & dosage · Antibodies, Monoclonal, Humanized/administration & dosage · Bevacizumab · Case-Control Studies · Female · Humans · Intravitreal Injections · Male · Middle Aged · Tomography, Optical Coherence · Vision Disorders/diagnosis · Vision Tests/instrumentation · Visual Acuity · Wet Macular Degeneration/diagnosis,drug therapy

Card 4 — M-CHARTS vs preferential hyperacuity perimetry correlations study (Arimura 2011, Investigative ophthalmology & visual science — 131 subjects: epiretinal membrane 39, macular hole 22, AMD 19, healthy controls 51): M-CHARTS sensitivity for subjective metamorphopsia exceeded PHP's in epiretinal membrane (89% vs 42%) and AMD (74% vs 68%) with better specificity in controls (100% vs 71%), and the Rasch-validated questionnaire correlated with M-CHARTS in epiretinal membrane (r = 0.59) but not macular hole — its PHP limb prints as a comparator; PHP has no standalone row

Study: Correlations / comparison study (primary report) — PHP limb comparator-only

Population: 131 subjects: 39 patients with idiopathic epiretinal membrane, 22 with idiopathic macular hole, 19 with age-related macular degeneration and 51 healthy controls; a 10-item metamorphopsia questionnaire (reduced to nine items by Rasch analysis) was compared with M-CHARTS scores and PreView PHP results against patients' subjective perception of metamorphopsia.

Summary: M-CHARTS vs preferential hyperacuity perimetry correlations study (Arimura 2011, Investigative ophthalmology & visual science — 131 subjects: epiretinal membrane 39, macular hole 22, AMD 19, healthy controls 51): M-CHARTS sensitivity for subjective metamorphopsia exceeded PHP's in epiretinal membrane (89% vs 42%) and AMD (74% vs 68%) with better specificity in controls (100% vs 71%), and the Rasch-validated questionnaire correlated with M-CHARTS in epiretinal membrane (r = 0.59) but not macular hole — its PHP limb prints as a comparator; PHP has no standalone row

Result: The nine-item questionnaire score correlated significantly with the M-CHARTS score in epiretinal membrane (r = 0.59, p = 0.0004) but not in macular hole, and with the PHP result in AMD (r = −0.29, p = 0.04) but not in epiretinal membrane. M-CHARTS showed better sensitivities than PHP in both epiretinal membrane (89% vs 42%) and AMD (74% vs 68%) and better specificity in healthy controls (100% vs 71%). Eighty percent of epiretinal-membrane patients with a greater horizontal M-CHARTS score subjectively perceived horizontal metamorphopsia more often. The authors conclude the questionnaire validly assesses subjective perception and supplements the clinical measurements, as published.

Watch out: The reference is subjective perception, and performance is disease-specific: the questionnaire–M-CHARTS correlation held in epiretinal membrane but not macular hole. PHP's figures are a comparator limb inside this study — PHP has no standalone shelf on this evidence and no home-monitoring claim may be built from this card.

Source: Arimura et al. Correlations between M-CHARTS and PHP findings and subjective perception of metamorphopsia in patients with macular diseases. Investigative ophthalmology & visual science. 2011. PMID: 20739469. Registry ID: none in the record. MeSH: Aged · Epiretinal Membrane/diagnosis · Female · Humans · Macular Degeneration/diagnosis · Male · Middle Aged · Retinal Diseases/diagnosis · Retinal Perforations/diagnosis · Sensitivity and Specificity · Sickness Impact Profile · Surveys and Questionnaires · Vision Disorders/diagnosis · Vision Tests/instrumentation · Visual Acuity · Visual Perception

Card 5 — Synthesis (4 reports): M-CHARTS quantify metamorphopsia in established macular disease with good internal consistency (α 0.934) and questionnaire agreement (ρ 0.405–0.475), detect distortion more often than the Amsler grid in wet AMD (89% vs 69%), outperform PHP against subjective perception in epiretinal membrane and AMD, and track post-surgical change on separate horizontal / vertical clocks — independently of visual acuity throughout

Study: Synthesis

Population: Synthesis of the 4 reports carded above (retinal-detachment validation n = 100; macular-hole study 22 eyes — small N; wet AMD study 36 patients + 23 controls; correlations study n = 131). Cross-points: the Amsler grid is homed at pack #7978 and contrast sensitivity at pack #7088 (PHYS).

Summary: Synthesis (4 reports): M-CHARTS quantify metamorphopsia in established macular disease with good internal consistency (α 0.934) and questionnaire agreement (ρ 0.405–0.475), detect distortion more often than the Amsler grid in wet AMD (89% vs 69%), outperform PHP against subjective perception in epiretinal membrane and AMD, and track post-surgical change on separate horizontal / vertical clocks — independently of visual acuity throughout

Result: Against questionnaire-defined metamorphopsia after retinal-detachment repair, a total score ≥0.2 gave sensitivity 72.7%, specificity 94.6% and AUC 0.801. In wet AMD, M-CHARTS detected metamorphopsia in 89% vs the Amsler grid's 69% (specificity 100% for both in 23 controls). Against subjective perception, M-CHARTS sensitivities exceeded PHP's (89% vs 42% in epiretinal membrane; 74% vs 68% in AMD; specificity 100% vs 71%). After macular-hole surgery the vertical score improved from one month and the horizontal at six months. In two studies the scores correlated with neither visual acuity nor retinal thickness — quantification of distortion is a separate outcome from acuity.

Watch out: Quantification, not screening: every figure comes from established macular disease or its surgical follow-up, against questionnaire or subjective references. No card supports M-CHARTS as a home detection test for new neovascular AMD.

Source: Synthesis of the reports carded above; no additional source.