SourceMed · Shelf #8117 in the ask interface
UCSD Shortness of Breath Questionnaire: consistent, reliable activity-breathlessness measure (α 0.95–0.97) validated in rehabilitation and ILD spectra — 3 reports
Shelf #8117 · Lungs, breathing & sleep
MEASUREMENT PROPERTIES — internal consistency and reliability established across derivation and ILD spectra: α 0.96 in the mixed rehabilitation derivation (n = 54, programme-labelled), α 0.95 with ICCs 0.93 / 0.95 in Brazilian ILD (n = 30), α 0.97 with a 12-point reliable-change threshold and a per-point hazard ratio of 1.02 (1.00 to 1.04) for death or transplant in fibrotic hypersensitivity pneumonitis; composition 3 reports, no COPD-only validation; a measurement-properties stamp, not a dyspnoea-treatment stamp
Stamped: 2026-11-28.
Evidence published: 1998–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the UCSD Shortness of Breath Questionnaire (SOBQ — 24 items rating breathlessness while performing activities of daily living, plus items on activity limitation and fear of breathlessness) — what internal consistency and criterion correlations did its validation establish in a pulmonary-rehabilitation population, how reliable and valid is the Brazilian Portuguese version in interstitial lung disease, and how does the score perform — reliability, validity and prognostic value — in fibrotic hypersensitivity pneumonitis?
Balance of the evidence
This is a measurement-properties shelf. Populations print: mixed pulmonary-rehabilitation diagnoses in the derivation (COPD 28, cystic fibrosis 9, post-lung-transplant 17); interstitial lung disease in both later reports — no anchor is a COPD-only validation, and no card may present these coefficients as COPD performance. The prognostic hazard ratio (1.02 per point) is a per-point figure on a 0–120 scale and prints with its scale, never as a per-patient risk claim. The reliable-change threshold (12 points) comes from a single fibrotic-hypersensitivity-pneumonitis cohort and prints as such. This row graduates Slate 29's Audit B count of 1 SOBQ report to a verified set of 3. Distinct from the CAT / CCQ / Dyspnea-12 shelves (health-status and sensation measures) and from the mMRC (a comparator inside the Brazilian report): the SOBQ rates breathlessness during specified daily activities; the dyspnoea rows cross-point.
MeSH: Activities of Daily Living · Adolescent · Adult · Aged · Aged, 80 and over · Child · Cystic Fibrosis/complications,rehabilitation · Dyspnea/diagnosis,etiology · Exercise Test · Female · Humans · Lung Diseases, Obstructive/complications,rehabilitation · Lung Transplantation/physiology,rehabilitation · Male · Middle Aged · Surveys and Questionnaires · Brazil · Idiopathic Pulmonary Fibrosis/complications,diagnosis · Lung Diseases, Interstitial/diagnosis · Psychometrics · Reproducibility of Results · Dyspnea/etiology,diagnosis,physiopathology · Alveolitis, Extrinsic Allergic/complications,physiopathology,diagnosis · Prospective Studies · Prognosis · Severity of Illness Index · Quality of Life · Vital Capacity · Symptom Burden
Cards (4)
Card 1 — Derivation validation (Eakin 1998, Chest — 54 pulmonary-rehabilitation patients: COPD 28, cystic fibrosis 9, post-lung-transplant 17): internal consistency α 0.96 and significant correlations with the Quality of Well-Being Scale, CES-D and post-walk Borg ratings — programme-labelled: the Eakin / Kaplan group's own report
Study: Validation study (primary report) — programme-labelled
Population: 54 patients (32 male, 22 female) enrolled in a university medical-centre pulmonary rehabilitation programme, with COPD (n = 28), cystic fibrosis (n = 9) and post-lung-transplant status (n = 17); they completed the SOBQ, the Quality of Well-Being Scale, the Center for Epidemiologic Studies Depression Scale and a six-minute walk with modified Borg breathlessness ratings.
Summary: Derivation validation (Eakin 1998, Chest — 54 pulmonary-rehabilitation patients: COPD 28, cystic fibrosis 9, post-lung-transplant 17): internal consistency α 0.96 and significant correlations with the Quality of Well-Being Scale, CES-D and post-walk Borg ratings — programme-labelled: the Eakin / Kaplan group's own report
Result: The current version of the SOBQ — a 24-item measure of self-reported shortness of breath while performing activities of daily living, revised because the previous format produced many 'not applicable' answers — demonstrated excellent internal consistency (alpha = 0.96) and was significantly correlated with all validity criteria (the Quality of Well-Being Scale, the CES-D and post-walk Borg ratings). The authors conclude the SOBQ is a valuable assessment tool in clinical practice and research in patients with moderate-to-severe lung disease, as published.
Watch out: Programme-labelled derivation in a mixed-diagnosis rehabilitation sample of 54: its α of 0.96 and its criterion correlations belong to that spectrum. The abstract reports the correlations as significant without printing their coefficients — no correlation value may be quoted from this report.
Source: Eakin et al. Validation of a new dyspnea measure: the UCSD Shortness of Breath Questionnaire. University of California, San Diego. Chest. 1998. PMID: 9515834. Registry ID: none in the record. MeSH: Activities of Daily Living · Adolescent · Adult · Aged · Aged, 80 and over · Child · Cystic Fibrosis/complications,rehabilitation · Dyspnea/diagnosis,etiology · Exercise Test · Female · Humans · Lung Diseases, Obstructive/complications,rehabilitation · Lung Transplantation/physiology,rehabilitation · Male · Middle Aged · Surveys and Questionnaires
Card 2 — Brazilian Portuguese validation in ILD (Silva 2021, Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia — 30 patients with interstitial lung disease assessed three times a week apart by two assessors): intra-rater ICC 0.93 and inter-rater ICC 0.95, α 0.95, correlations with the MRC dyspnoea scale (r = 0.56), SF-36 domains (−0.40 to −0.74), six-minute walk distance (−0.38) and quadriceps strength (−0.41) — small N (30) prints on the face
Study: Cross-cultural validation (primary report) — small N prints
Population: 30 patients with interstitial lung disease (idiopathic pulmonary fibrosis, connective-tissue-disease-associated pulmonary fibrosis, sarcoidosis, asbestosis or non-specific interstitial pneumonia; 15 men; mean age 59 ± 10 years; DLCO 46 [33–64]% predicted), completing the questionnaire at three time points one week apart with two independent assessors.
Summary: Brazilian Portuguese validation in ILD (Silva 2021, Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia — 30 patients with interstitial lung disease assessed three times a week apart by two assessors): intra-rater ICC 0.93 and inter-rater ICC 0.95, α 0.95, correlations with the MRC dyspnoea scale (r = 0.56), SF-36 domains (−0.40 to −0.74), six-minute walk distance (−0.38) and quadriceps strength (−0.41) — small N (30) prints on the face
Result: UCSD SOBQ scores showed excellent agreement and internal consistency in the intra-rater analysis (ICC 0.93, 95% CI 0.85 to 0.97; Cronbach alpha 0.95) and the inter-rater analysis (ICC 0.95, 95% CI 0.89 to 0.97; alpha 0.95), and correlated significantly with dyspnoea on the Medical Research Council scale (r = 0.56), SF-36 domains bodily pain, general health, vitality and physical functioning (−0.40 to −0.74), six-minute walk distance (r = −0.38) and quadriceps muscle strength (r = −0.41). The authors conclude the Brazilian Portuguese version is valid, reliable and internally consistent in ILD in Brazil, as published.
Watch out: Small N prints: 30 patients. An ILD validation of a translated version — its coefficients are Brazilian-ILD performance, not COPD performance and not original-language performance. The MRC scale inside it is a comparator limb.
Source: Silva et al. Validation of the Brazilian Portuguese version of the University of California San Diego Shortness of Breath Questionnaire in patients with interstitial lung disease. Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia. 2021. PMID: 34932719. Registry ID: none in the record. MeSH: Aged · Brazil · Dyspnea/diagnosis,etiology · Humans · Idiopathic Pulmonary Fibrosis/complications,diagnosis · Lung Diseases, Interstitial/diagnosis · Male · Middle Aged · Psychometrics · Reproducibility of Results · Surveys and Questionnaires
Card 3 — Fibrotic hypersensitivity pneumonitis study (Swigris 2026, Annals of the American Thoracic Society — multicentre prospective cohort): α 0.97, correlations with FVC% (−0.46), DLCO% (−0.32) and Borg scores (0.56), known-groups separation by physiology strata, a 95%-confidence reliable-change threshold of 12 points, and each 1-point higher baseline score associated with a hazard ratio of 1.02 (95% CI 1.00 to 1.04) for death or transplant (labelled as such)
Study: Prospective validity / prognostic study (primary report)
Population: A prospective multicentre cohort of patients with fibrotic hypersensitivity pneumonitis completing the UCSD-SOBQ and other severity metrics at baseline, 6 and 12 months; psychometric analyses examined reliability, responsiveness and validity, and score changes were assessed against survival (death or transplant).
Summary: Fibrotic hypersensitivity pneumonitis study (Swigris 2026, Annals of the American Thoracic Society — multicentre prospective cohort): α 0.97, correlations with FVC% (−0.46), DLCO% (−0.32) and Borg scores (0.56), known-groups separation by physiology strata, a 95%-confidence reliable-change threshold of 12 points, and each 1-point higher baseline score associated with a hazard ratio of 1.02 (95% CI 1.00 to 1.04) for death or transplant (labelled as such)
Result: At baseline, internal consistency was high (Cronbach's α = 0.97). Moderately strong correlations were observed with percent-predicted FVC (r = −0.46), percent-predicted DLCO (r = −0.32) and Borg dyspnea scores (r = 0.56). Scores differed significantly between the lowest and highest strata of FVC%, DLCO% and Borg scores. The threshold for worsening within-individual change at 95% confidence was 12 points. A 1-point higher baseline score was associated with a hazard ratio of 1.02 (95% CI 1.00 to 1.04) for death or transplant (labelled as such). The authors conclude the score is a reliable and valid measure of dyspnea severity in fibrotic hypersensitivity pneumonitis, responsive to change and associated with transplant-free survival, as published.
Watch out: The hazard ratio is per single point on a 0–120 scale (1.02, interval touching 1.00): it prints with its scale and may never be rendered as a per-patient risk claim. The 12-point reliable-change threshold is one fHP cohort's figure. A prognostic association in an observational cohort, not a treatment effect.
Source: Swigris et al. Validity and prognostic value of the University of California, San Diego dyspnea questionnaire in fibrotic hypersensitivity pneumonitis: a multicenter prospective study. Annals of the American Thoracic Society. 2026. PMID: 42127979. Registry ID: none in the record. MeSH: Humans · Dyspnea/etiology,diagnosis,physiopathology · Alveolitis, Extrinsic Allergic/complications,physiopathology,diagnosis · Prospective Studies · Female · Surveys and Questionnaires · Male · Prognosis · Severity of Illness Index · Reproducibility of Results · Middle Aged · Aged · Psychometrics · Quality of Life · Vital Capacity · Symptom Burden
Card 4 — Synthesis (3 reports): the SOBQ is internally consistent (α 0.95–0.97) and reliable across its derivation spectrum and two ILD validations, correlates with dyspnoea scales, walk distance and physiology as expected, and carries a small per-point prognostic association in fibrotic hypersensitivity pneumonitis — with no COPD-only validation among its anchors
Study: Synthesis
Population: Synthesis of the 3 reports carded above (derivation validation n = 54, programme-labelled; Brazilian ILD validation n = 30 — small N; fibrotic hypersensitivity pneumonitis prospective cohort, multicentre).
Summary: Synthesis (3 reports): the SOBQ is internally consistent (α 0.95–0.97) and reliable across its derivation spectrum and two ILD validations, correlates with dyspnoea scales, walk distance and physiology as expected, and carries a small per-point prognostic association in fibrotic hypersensitivity pneumonitis — with no COPD-only validation among its anchors
Result: Internal consistency was α 0.96 in the mixed pulmonary-rehabilitation derivation, α 0.95 with intra- / inter-rater ICCs of 0.93 / 0.95 in Brazilian ILD, and α 0.97 in fibrotic hypersensitivity pneumonitis. Validity correlations ran in the expected directions against dyspnoea scales (MRC r = 0.56; Borg r = 0.56), quality-of-life domains (−0.40 to −0.74), walk distance (−0.38), quadriceps strength (−0.41) and physiology (FVC% −0.46; DLCO% −0.32). In fHP, a 12-point within-person worsening was the 95%-confidence reliable-change threshold, and baseline score carried a per-point hazard ratio of 1.02 (1.00 to 1.04) for death or transplant.
Watch out: Population discipline restated: derivation in mixed rehabilitation diagnoses, both later reports in interstitial lung disease — the shelf contains no COPD-only validation, and its coefficients may not be cited as COPD performance.
Source: Synthesis of the reports carded above; no additional source.