SourceMed · Shelf #8127 in the ask interface

Codex cognitive screen: sensitivity 93% / specificity 85% for dementia in its derivation-and-validation study, 0.81 / 0.81 in a later memory-clinic study — but only 0.68 sensitivity for MCI — 3 reports, all in memory-clinic spectra

Shelf #8127 · Brain, stroke & mind

MEASUREMENT PROPERTIES / PREDICTIVE PERFORMANCE — Codex for dementia: sensitivity 93% / specificity 85% in the derivation group's validation (n = 323) and 0.81 / 0.81 in a later memory-clinic study (n = 105); for MCI the same study found sensitivity only 0.68 (specificity 0.90), and the independent head-to-head (n = 162) found both Codex and Mini-Cog >0.8 sensitive for dementia with Codex more specific but Mini-Cog more sensitive for MCI — dementia accuracy ESTABLISHED in clinic spectra, MCI sensitivity NOT ESTABLISHED as adequate; no community-screening evidence in any report

Stamped: 2026-11-28.

Evidence published: 1983–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does Codex (the cognitive disorders examination — a three-minute decision-tree screen built from clock-drawing and three-word recall, sorting patients into probability categories for dementia) detect dementia and mild cognitive impairment against clinical / DSM diagnosis — what sensitivity and specificity did its derivation-and-validation study find, what did the later memory-clinic study find for dementia and for MCI, and how did it compare head-to-head with the Mini-Cog in a consecutive cognitive-clinic cohort?

Balance of the evidence

This is a screening-accuracy shelf, framed in predictive-performance / measurement-properties terms — no treatment claim. All three spectra are memory-clinic / cognitive-clinic attenders: no figure generalises to community screening. The derivation and second report share the French memory-clinic tradition and print as programme-linked (the Belmin group's own instrument); the 2020 head-to-head is the independent limb. The MCI limb is the weak limb (sensitivity 0.68 in the second report; Mini-Cog more sensitive for MCI in the head-to-head) and prints beside the dementia figures. The 2020 report's abstract gives dementia sensitivity only as a bound (>0.8) — no exact Codex pair is printed from it beyond what its abstract states. Distinct from the Mini-Cog home (#8013 — a comparator inside the third report) and the neighbouring cognition shelves; cross-points at build.

MeSH: Age Factors · Aged · Bayes Theorem · Decision Support Techniques · Dementia/diagnosis · Diagnostic and Statistical Manual of Mental Disorders · Education · Female · Geriatric Assessment · Humans · Male · Mental Status Schedule · Primary Health Care · Regression Analysis · Sensitivity and Specificity · Sex Factors · Adult · Aged, 80 and over · Cognition Disorders/diagnosis · Cognitive Dysfunction/diagnosis · Mass Screening/methods · Neuropsychological Tests · Predictive Value of Tests · Prevalence

Cards (4)

Card 1 — Derivation-and-validation study — programme's own report (Belmin 2007, Presse medicale — derivation in 242 memory-clinic patients, validation in 323 subjects across six memory clinics): Codex sensitivity 93% / specificity 85% for dementia against DSM-IV, vs 88% / 87% for the multivariable logistic model and 94% / 67% (or 91% / 70% by cut-off) for the MMSE

Study: Diagnostic-accuracy derivation-and-validation study (primary report) — programme's own report, printed as programme-linked

Population: Derivation: consecutive patients attending a single memory clinic over two years (242), with educational level, MMSE scores/subscores and a simplified clock-drawing test recorded and dementia diagnosed by DSM-IV criteria. Validation: consecutive patients of six memory clinics (323) whose dementia status was previously determined by DSM-IV criteria. Programme-labelled: the Belmin group's own report of its own instrument.

Summary: Derivation-and-validation study — programme's own report (Belmin 2007, Presse medicale — derivation in 242 memory-clinic patients, validation in 323 subjects across six memory clinics): Codex sensitivity 93% / specificity 85% for dementia against DSM-IV, vs 88% / 87% for the multivariable logistic model and 94% / 67% (or 91% / 70% by cut-off) for the MMSE

Result: Independent variables correlated with dementia were sex, the simplified clock-drawing test and two MMSE subscores (three-word recall, spatial orientation); the resulting two-step decision tree (Codex) takes 2–3 minutes. In validation, Codex sensitivity was 93% and specificity 85%; the logistic model gave 88% / 87% and the MMSE 94% / 67% or 91% / 70% depending on cut-off. Codex sensitivity was significantly higher than the model's and its specificity significantly greater than the MMSE's, as published.

Watch out: Derivation and validation by the instrument's own group in memory-clinic spectra — the 93% / 85% pair is the programme's best-case estimate and prints with that provenance; it says nothing about community or primary-care screening performance.

Source: Belmin et al. The cognitive disorders examination (Codex) is a reliable 3-minute test for detection of dementia in the elderly (validation study on 323 subjects). Presse medicale (Paris, France : 1983). 2007. PMID: 17433613. Registry ID: none in the record. MeSH: Age Factors · Aged · Bayes Theorem · Decision Support Techniques · Dementia/diagnosis · Diagnostic and Statistical Manual of Mental Disorders · Education · Female · Geriatric Assessment · Humans · Male · Mental Status Schedule · Primary Health Care · Regression Analysis · Sensitivity and Specificity · Sex Factors

Card 2 — Later memory-clinic study (Larner 2013, Presse medicale — 105 consecutive memory-clinic patients): Codex sensitivity / specificity 0.81 / 0.81 for dementia, and 0.68 / 0.90 for MCI — the author concludes Codex is reliable for dementia but not sufficiently sensitive for MCI

Study: Diagnostic-accuracy study (primary report) — programme-linked memory-clinic tradition; dementia and MCI limbs printed separately

Population: 105 consecutive patients attending a memory clinic over six months, administered Codex and classified for dementia and mild cognitive impairment.

Summary: Later memory-clinic study (Larner 2013, Presse medicale — 105 consecutive memory-clinic patients): Codex sensitivity / specificity 0.81 / 0.81 for dementia, and 0.68 / 0.90 for MCI — the author concludes Codex is reliable for dementia but not sufficiently sensitive for MCI

Result: Codex showed sensitivity 0.81 and specificity 0.81 for identifying dementia. For detection of MCI, sensitivity was 0.68 and specificity 0.90. The author concludes Codex is a simple, quick and reliable test for the detection of dementia, but is not sufficiently sensitive for the detection of MCI, as published.

Watch out: The MCI sensitivity of 0.68 misses roughly one in three MCI cases — any use of Codex to rule out MCI is unsupported by this report, and the dementia pair (0.81 / 0.81) is materially lower than the derivation group's 93% / 85%.

Source: Larner et al. Codex (cognitive disorders examination) for the detection of dementia and mild cognitive impairment. Presse medicale (Paris, France : 1983). 2013. PMID: 24157185. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cognition Disorders/diagnosis · Cognitive Dysfunction/diagnosis · Dementia/diagnosis · Female · Humans · Male · Mass Screening/methods · Neuropsychological Tests · Predictive Value of Tests · Prevalence · Sensitivity and Specificity

Card 3 — Independent head-to-head with Mini-Cog (Larner 2020, Dementia & neuropsychologia — 162 consecutive cognitive-clinic patients: 44 dementia, 26 MCI, 92 subjective complaint): both tests had sensitivity >0.8 for dementia (printed as a bound, as the abstract states it), Codex was more specific for dementia, and Mini-Cog was more sensitive for MCI, with larger net benefit for MCI diagnosis

Study: Diagnostic-accuracy head-to-head study (primary report) — the independent limb; abstract reports bounds/comparisons, printed as such

Population: A consecutive cohort of 162 patients attending a dedicated cognitive disorders clinic, given both Mini-Cog and Codex, with reference-standard diagnoses by clinical diagnostic criteria (dementia 44, MCI 26, subjective memory complaint 92). Independent of the derivation programme.

Summary: Independent head-to-head with Mini-Cog (Larner 2020, Dementia & neuropsychologia — 162 consecutive cognitive-clinic patients: 44 dementia, 26 MCI, 92 subjective complaint): both tests had sensitivity >0.8 for dementia (printed as a bound, as the abstract states it), Codex was more specific for dementia, and Mini-Cog was more sensitive for MCI, with larger net benefit for MCI diagnosis

Result: Both Mini-Cog and Codex had high sensitivity (>0.8) for dementia diagnosis, but Codex was more specific. For MCI diagnosis, Mini-Cog had better sensitivity than Codex. Weighted comparisons showed only marginal net benefit for Mini-Cog for dementia diagnosis but larger net benefit for MCI diagnosis. The author concludes both are accurate brief screens for dementia but Mini-Cog is better for identification of MCI, as published. No exact Codex sensitivity/specificity pair is printed from this report beyond the >0.8 bound its abstract states.

Watch out: A pragmatic clinic cohort in which most patients (92 of 162) had subjective complaint only — a different spectrum from the derivation clinics. The comparison favours Codex on dementia specificity and Mini-Cog on MCI sensitivity; neither result licenses community screening claims.

Source: Larner et al. Mini-Cog versus Codex (cognitive disorders examination) Is there a difference?. Dementia & neuropsychologia. 2020. PMID: 32595881. Registry ID: none in the record. MeSH: none in the record

Card 4 — Synthesis (3 reports): Codex detects dementia in memory-clinic spectra with sensitivity 0.81–0.93 and specificity 0.81–0.85 across its programme-linked and later clinic studies, and the independent head-to-head confirms >0.8 dementia sensitivity with better specificity than Mini-Cog — but its MCI sensitivity (0.68) is inadequate in the one study that measured it and Mini-Cog beats it for MCI; all evidence is clinic-based, so community screening performance is NOT ESTABLISHED

Study: Synthesis

Population: Synthesis of the 3 reports carded above: derivation/validation (242 + 323, programme's own group), memory-clinic study (105) and independent head-to-head (162) — all clinic attenders, no community sample in any report.

Summary: Synthesis (3 reports): Codex detects dementia in memory-clinic spectra with sensitivity 0.81–0.93 and specificity 0.81–0.85 across its programme-linked and later clinic studies, and the independent head-to-head confirms >0.8 dementia sensitivity with better specificity than Mini-Cog — but its MCI sensitivity (0.68) is inadequate in the one study that measured it and Mini-Cog beats it for MCI; all evidence is clinic-based, so community screening performance is NOT ESTABLISHED

Result: Dementia: 93% / 85% (validation, n = 323); 0.81 / 0.81 (n = 105); >0.8 sensitivity with greater specificity than Mini-Cog (n = 162). MCI: 0.68 / 0.90 (n = 105); Mini-Cog more sensitive in the head-to-head. Administration time 2–3 minutes. Cross-point: Mini-Cog is homed at #8013, where it appears here only as a comparator.

Watch out: Never print a single Codex accuracy pair without its spectrum (memory clinic) and target (dementia vs MCI): the same instrument is adequate for one target and inadequate for the other in the same study.

Source: Synthesis of the reports carded above; no additional source.