SourceMed · Shelf #8128 in the ask interface

Eurotest dementia screen: sensitivity 0.91 / specificity 0.82 at cut-off 20/21 in the phase-II study; inside two shared phase-III head-to-head studies its dementia accuracy was 0.87 (κ = 0.71) and its AUC 0.91 — euro-currency-specific, 4 reports (2 shared, printed as shared)

Shelf #8128 · Brain, stroke & mind

MEASUREMENT PROPERTIES / PREDICTIVE PERFORMANCE — Eurotest for dementia: phase-I sensitivity 0.93 / specificity 0.87 in a 50%-prevalence convenience sample (n = 60); phase-II sensitivity 0.91 / specificity 0.82, aROC 0.93 at cut-off 20/21 in naturalistic clinics (n = 481 tested, 38.7% illiterate), with no educational influence on scores or accuracy; shared phase-III limbs: dementia diagnostic accuracy 0.87 (κ = 0.71) in 139 primary-care patients and AUC 0.91 ± 0.02 in 141 — accuracy ESTABLISHED for dementia in Spanish clinic/primary-care spectra, at the cost of the longest administration (7.1 minutes); euro-currency-specific — performance outside euro settings NOT ESTABLISHED; composition 2 dedicated + 2 shared reports (shared with #8129 for different limbs, printed as shared)

Stamped: 2026-11-28.

Evidence published: 2004–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does the Eurotest (a brief dementia screen based on knowledge and handling of euro coins and notes, designed to be applicable to illiterate people and free of educational influence) detect dementia and cognitive impairment — what sensitivity and specificity did its preliminary phase-I evaluation and its naturalistic multicentre phase-II study find, and how did it perform inside the two later phase-III head-to-head studies of brief tests applicable to illiterates and of guideline-recommended brief tests in primary care?

Balance of the evidence

This is a screening-accuracy shelf, framed in predictive-performance / measurement-properties terms. COMPOSITION PRINTED ON THE FACE: 4 reports — 2 dedicated Eurotest studies (phase I, phase II) + 2 SHARED phase-III multi-test studies (PMIDs 22073256 and 35504802) carded here for their EUROTEST limbs by row direction; the same two studies are carded on pack #8129 for their Phototest limbs — a different instrument's limb on each pack, one study never counted twice within a pack. The duplicate record PMID 31402066 is the same study as 35504802 and is REFUSED — only 35504802 is carded. The phase-I pair comes from a 50%-prevalence convenience sample and prints with that design. The instrument is euro-currency-specific: its evidence does not transfer to non-euro settings, and no card presents it as a general money-handling test. A fifth report (PMID 17364253, reliability: test–retest ICC 0.94, inter-rater 0.91) is recorded in this balance as reliability context and is not carded as an accuracy anchor. Distinct from pack #8129 (Phototest — the same programme's picture-based test) and the homed cognition rows; cross-points at build.

MeSH: Aged · Aged, 80 and over · Chi-Square Distribution · Dementia/diagnosis · Educational Status · Female · Humans · Linear Models · Male · Mass Screening · Neuropsychological Tests · Predictive Value of Tests · ROC Curve · Sensitivity and Specificity · Cross-Sectional Studies · Dementia/diagnosis/psychology · Europe · Financial Management · Logistic Models · Middle Aged · Psychological Tests · Reproducibility of Results · Socioeconomic Factors · Cognition Disorders/diagnosis/economics · Dementia/diagnosis/economics · Cognition Disorders/diagnosis · Alzheimer Disease/diagnosis · Cognitive Dysfunction/diagnosis · Mass Screening · Neuropsychological Tests

Cards (5)

Card 1 — Phase-I preliminary evaluation — programme's own report (Carnero-Pardo 2004, Revista de neurologia — 30 mild dementia / 30 non-dementia, pre-test prevalence 50% by design): Eurotest sensitivity 0.93 (95% CI 0.76 to 0.99), specificity 0.87 (0.68 to 0.96), administration 6.77 minutes, scores unaffected by schooling

Study: Phase I diagnostic-accuracy study (primary report) — dedicated; 50%-prevalence convenience sample, printed with its design

Population: People over 65 with no sensory deficit: 30 with mild dementia and 30 without dementia, a convenience sample with pre-test prevalence of 50% by design; assessed with sociodemographic variables, MMSE, Pfeiffer's SPMSQ, the seven-minute test and the Eurotest. Programme-labelled: the Carnero group's own report.

Summary: Phase-I preliminary evaluation — programme's own report (Carnero-Pardo 2004, Revista de neurologia — 30 mild dementia / 30 non-dementia, pre-test prevalence 50% by design): Eurotest sensitivity 0.93 (95% CI 0.76 to 0.99), specificity 0.87 (0.68 to 0.96), administration 6.77 minutes, scores unaffected by schooling

Result: The groups did not differ in age, sex, schooling, literacy, employment or knowledge of money systems. The Eurotest had sensitivity 0.93 (0.76–0.99) and specificity 0.87 (0.68–0.96), similar to the MMSE and the seven-minute test. The Eurotest (6.77 ± 1.65 min) took less time than the seven-minute test (8.87 ± 1.81 min) and was not modified by clinical situation; schooling did not affect Eurotest results, as published.

Watch out: A 30/30 case-control-style spectrum at 50% prevalence flatters sensitivity and specificity and gives no usable predictive values for clinic use — this pair is a feasibility estimate, superseded for practice by the phase-II and phase-III figures.

Source: Carnero-Pardo et al. [Preliminary evaluation of a new screening test for dementia (Eurotest)]. Revista de neurologia. 2004. PMID: 14963845. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Chi-Square Distribution · Dementia/diagnosis · Educational Status · Female · Humans · Linear Models · Male · Mass Screening · Neuropsychological Tests · Predictive Value of Tests · ROC Curve · Sensitivity and Specificity

Card 2 — Phase-II naturalistic multicentre study (Carnero-Pardo 2006, BMC neurology — 481 tested, 101 with dementia, 38.7% totally or functionally illiterate): at cut-off 20/21, sensitivity 0.91 (0.84 to 0.96), specificity 0.82 (0.77 to 0.85), aROC 0.93 (0.91 to 0.95); neither scores nor accuracy influenced by social or educational factors; mean administration 8.2 minutes

Study: Phase II diagnostic-accuracy study (primary report) — dedicated; naturalistic clinic spectrum, the shelf's anchor estimate

Population: Consecutive patients over 60 in general neurology clinics across 16 neurologists: 516 recruited (101 dementia, 380 no dementia, 35 excluded); 481 took the Eurotest, of whom 38.7% were totally or functionally illiterate and 45.5% had no formal education; reference classification by DSM-IV criteria.

Summary: Phase-II naturalistic multicentre study (Carnero-Pardo 2006, BMC neurology — 481 tested, 101 with dementia, 38.7% totally or functionally illiterate): at cut-off 20/21, sensitivity 0.91 (0.84 to 0.96), specificity 0.82 (0.77 to 0.85), aROC 0.93 (0.91 to 0.95); neither scores nor accuracy influenced by social or educational factors; mean administration 8.2 minutes

Result: The best cut-off was 20/21, with sensitivity 0.91 (0.84–0.96), specificity 0.82 (0.77–0.85) and aROC 0.93 (0.91–0.95). Mean administration time was 8.2 ± 2.0 minutes. Neither Eurotest scores nor diagnostic accuracy were influenced by social or educational factors in regression analyses. The authors conclude the Eurotest is a rapid, simple and useful screening instrument free from educational influences, as published.

Watch out: The education-free claim is tested here in a genuinely illiterate-heavy sample (38.7%) — the strongest card for the instrument's defining property. Administration at 8.2 minutes is not the 'very brief' test the phase-III comparison later penalises; time prints with the accuracy.

Source: Carnero-Pardo et al. Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study. BMC neurology. 2006. PMID: 16606455. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cross-Sectional Studies · Dementia/diagnosis/psychology · Educational Status · Europe · Female · Financial Management · Humans · Logistic Models · Male · Middle Aged · Psychological Tests · ROC Curve · Reproducibility of Results · Sensitivity and Specificity · Socioeconomic Factors

Card 3 — Phase-III three-test study — EUROTEST LIMB of a SHARED report (Carnero-Pardo 2011, PLoS One — 139 primary-care patients with suspected impairment: 47 dementia, 36 cognitive impairment, 56 none): for dementia, κ = 0.71 (0.59 to 0.83) and diagnostic accuracy 0.87 (0.80 to 0.92); for cognitive impairment, κ = 0.67 and accuracy 0.83. SHARED REPORT PRINTED AS SHARED: this study is carded here for its Eurotest limb and on pack #8129 for its Phototest limb — a different instrument's limb on each pack

Study: Phase III diagnostic-accuracy study (primary report) — SHARED report by row direction: Eurotest limb here, Phototest limb on pack #8129; printed as shared

Population: 139 individuals with suspicion of cognitive impairment or dementia in four primary-care centres, all given the Eurotest, Memory Alteration Test (M@T) and Phototest in balanced order, with an independent blinded gold-standard diagnosis by expert-neurologist consensus. This card reports the study for its Eurotest limb only.

Summary: Phase-III three-test study — EUROTEST LIMB of a SHARED report (Carnero-Pardo 2011, PLoS One — 139 primary-care patients with suspected impairment: 47 dementia, 36 cognitive impairment, 56 none): for dementia, κ = 0.71 (0.59 to 0.83) and diagnostic accuracy 0.87 (0.80 to 0.92); for cognitive impairment, κ = 0.67 and accuracy 0.83. SHARED REPORT PRINTED AS SHARED: this study is carded here for its Eurotest limb and on pack #8129 for its Phototest limb — a different instrument's limb on each pack

Result: No significant differences in effectiveness were found among the three tests. For dementia screening, the Eurotest gave κ = 0.71 (0.59–0.83) and diagnostic accuracy 0.87 (0.80–0.92); for cognitive-impairment screening, κ = 0.67 and accuracy 0.83. Costs of dementia screening did not differ; application time was shorter with Phototest (2.8 ± 0.8 min) than with Eurotest (7.1 ± 1.8 min), as published.

Watch out: Multi-test study: the Eurotest limb prints as a limb, and its κ/accuracy are agreement-with-consensus measures, not a fresh sensitivity/specificity pair — do not restate them as such. The same study counted once here and once on #8129 is row-directed sharing, never two confirmations of either test.

Source: Carnero-Pardo et al. Diagnostic accuracy, effectiveness and cost for cognitive impairment and dementia screening of three short cognitive tests applicable to illiterates. PloS one. 2011. PMID: 22073256. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cognition Disorders/diagnosis/economics · Dementia/diagnosis/economics · Educational Status · Female · Humans · Male · Middle Aged · Sensitivity and Specificity

Card 4 — Phase-III eight-test study — EUROTEST LIMB of a SHARED report (Carnero-Pardo 2022, Neurologia — 141 primary-care patients with suspected impairment, 86 with cognitive impairment): Eurotest AUC 0.91 ± 0.02, among the best-performing tests, but with the longest administration (7.1 minutes). SHARED REPORT PRINTED AS SHARED: carded here for its Eurotest limb and on pack #8129 for its Phototest limb. Its duplicate record PMID 31402066 is the same study and is REFUSED — only this record (35504802) is carded

Study: Phase III diagnostic-accuracy study (primary report) — SHARED report by row direction: Eurotest limb here, Phototest limb on pack #8129; duplicate record 31402066 refused, printed on the face

Population: 141 individuals with suspected cognitive impairment in primary care, all completing eight brief tests (MMSE, MEC, SPMSQ, MIS, Clock Drawing Test, Eurotest, Fototest and M@T), with cognitive impairment diagnosed independently by researchers blinded to test scores. This card reports the study for its Eurotest limb only.

Summary: Phase-III eight-test study — EUROTEST LIMB of a SHARED report (Carnero-Pardo 2022, Neurologia — 141 primary-care patients with suspected impairment, 86 with cognitive impairment): Eurotest AUC 0.91 ± 0.02, among the best-performing tests, but with the longest administration (7.1 minutes). SHARED REPORT PRINTED AS SHARED: carded here for its Eurotest limb and on pack #8129 for its Phototest limb. Its duplicate record PMID 31402066 is the same study and is REFUSED — only this record (35504802) is carded

Result: The Eurotest and M@T (AUC ± SE 0.91 ± 0.02 and 0.90 ± 0.02) had significantly better diagnostic performance than the MMSE, MEC, SPMSQ and Clock Drawing Test, but not compared with MIS or Fototest (both AUC 0.87 ± 0.03); the Eurotest took longest to administer (7.1 [1.8] minutes) while Fototest took less than half as long (2.8 [0.8] minutes). The authors list the Eurotest, M@T and Fototest as the most advisable tests for primary-care screening, as published.

Watch out: The target here is cognitive impairment (not dementia alone) and the metric is AUC across eight tests in one sample — comparative ranking evidence, not a stand-alone Eurotest validation. Administration time (longest of the set) is part of this instrument's real-world performance and prints with the AUC.

Source: Carnero-Pardo et al. Diagnostic performance of brief cognitive tests in cognitive impairment screening. Neurologia. 2022. PMID: 35504802. Registry ID: none in the record. MeSH: Alzheimer Disease/diagnosis · Cognition Disorders/diagnosis · Cognitive Dysfunction/diagnosis · Dementia/diagnosis · Humans · Mass Screening · Neuropsychological Tests

Card 5 — Synthesis (4 reports — 2 dedicated + 2 shared phase-III limbs, printed as shared): the Eurotest detects dementia with sensitivity ≈0.91–0.93 and specificity ≈0.82–0.87 in Spanish clinic spectra, holds an AUC of 0.91 in a primary-care eight-test comparison, and is the one brief test whose scores and accuracy were shown uninfluenced by education in an illiterate-heavy sample — at the cost of the longest administration time (7.1–8.2 minutes), and only within the euro-currency setting it was built for

Study: Synthesis

Population: Synthesis of the 4 reports carded above: phase I (60, 50% prevalence by design), phase II (481 tested), phase-III three-test study (139, shared — Eurotest limb) and phase-III eight-test study (141, shared — Eurotest limb). The shared studies are also carded on pack #8129 for their Phototest limbs; the duplicate record PMID 31402066 was refused. A reliability report (PMID 17364253; test–retest ICC 0.94, inter-rater 0.91) is context in the balance, not an accuracy anchor.

Summary: Synthesis (4 reports — 2 dedicated + 2 shared phase-III limbs, printed as shared): the Eurotest detects dementia with sensitivity ≈0.91–0.93 and specificity ≈0.82–0.87 in Spanish clinic spectra, holds an AUC of 0.91 in a primary-care eight-test comparison, and is the one brief test whose scores and accuracy were shown uninfluenced by education in an illiterate-heavy sample — at the cost of the longest administration time (7.1–8.2 minutes), and only within the euro-currency setting it was built for

Result: Dementia: sensitivity 0.93 / specificity 0.87 (phase I); 0.91 / 0.82 with aROC 0.93 at cut-off 20/21 (phase II); diagnostic accuracy 0.87, κ = 0.71 (phase III, 2011). Cognitive impairment: accuracy 0.83, κ = 0.67 (2011); AUC 0.91 ± 0.02 (2022). Education: no influence on scores or accuracy in the phase-II sample (38.7% illiterate). Time: 6.77–8.2 minutes — longest in both phase-III comparisons.

Watch out: Never transfer these figures outside euro-currency populations: the test items are euro coins and notes. Never cite the phase-III limbs without the shared-report label, and never count PMID 31402066 as a further study — it is a duplicate record of 35504802.

Source: Synthesis of the reports carded above; no additional source.