SourceMed · Shelf #8129 in the ask interface
Phototest dementia screen: phase-II aROC 0.95 for both dementia and cognitive impairment with cut-offs 25/26 and 28/29, confirmed inside two shared phase-III studies (accuracy 0.86, κ = 0.70; AUC 0.87) in under 3 minutes — 1 dedicated + 2 shared reports, printed as shared
Shelf #8129 · Brain, stroke & mind
MEASUREMENT PROPERTIES / PREDICTIVE PERFORMANCE — Phototest: phase-II diagnostic accuracy (aROC) 0.95 ± 0.01 for both dementia and cognitive impairment, at cut-off 25/26 sensitivity 0.88 / specificity 0.90 for dementia and at 28/29 0.90 / 0.90 for impairment, scores uninfluenced by education (n = 378 including 70 healthy controls — spectrum printed); shared phase-III limbs: dementia accuracy 0.86 (κ = 0.70) in 139 primary-care patients and AUC 0.87 ± 0.03 in 141, with the shortest administration (2.8 minutes) — accuracy ESTABLISHED in Spanish clinic/primary-care spectra on a composition of 1 dedicated + 2 shared reports (shared with #8128 for different limbs, printed as shared); duplicate record 31402066 refused
Stamped: 2026-11-28.
Evidence published: 2007–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does the Phototest (a very brief (<3-minute) picture-based screen — naming, verbal fluency and immediate / delayed recall of pictured objects — designed for illiterate subjects and uninfluenced by education) detect dementia and cognitive impairment — what diagnostic accuracy and cut-offs did its phase-II validation find against the Eurotest and verbal fluency, and how did it perform inside the two later phase-III head-to-head studies?
Balance of the evidence
This is a screening-accuracy shelf, framed in predictive-performance / measurement-properties terms. COMPOSITION PRINTED ON THE FACE: 1 dedicated derivation/validation study + 2 SHARED phase-III multi-test studies (PMIDs 22073256 and 35504802) carded here for their PHOTOTEST limbs by row direction; the same two studies are carded on pack #8128 for their Eurotest limbs — a different instrument's limb on each pack, one study never counted twice within a pack. The duplicate record PMID 31402066 is the same study as 35504802 and is REFUSED — only 35504802 is carded. TYPE NOTE PRINTED ON THE FACE: the derivation record (PMID 18040903) is typed Editorial at PubMed alongside Clinical Trial, Phase II / Validation Study; the type set is printed on its card and the report is counted on its described design. The derivation's healthy-control limb (70 subjects) inflates its spectrum and prints. Administration time is part of this instrument's claim (2.8 vs 7.1 minutes for the Eurotest in the 2022 study) and prints with the accuracy figures. Distinct from pack #8128 (Eurotest): the two tests share a programme and two reports but ask different questions (picture naming/recall vs money handling); the rows cross-point.
MeSH: Aged · Cognition Disorders/diagnosis · Cross-Sectional Studies · Dementia/diagnosis · Diagnostic Techniques, Neurological · Female · Humans · Male · Reproducibility of Results · Cognition Disorders/diagnosis/economics · Dementia/diagnosis/economics · Educational Status · Aged, 80 and over · Sensitivity and Specificity · Alzheimer Disease/diagnosis · Cognitive Dysfunction/diagnosis · Mass Screening · Neuropsychological Tests
Cards (4)
Card 1 — Phase-II validation — the dedicated derivation study (Carnero Pardo 2007, Neurologia — 308 neurology referrals + 70 healthy subjects: 225 without impairment, 58 with impairment without dementia, 95 with dementia): Phototest aROC 0.95 ± 0.01 for both dementia and cognitive impairment, similar to the Eurotest's and above verbal fluency's; at cut-off 25/26 for dementia sensitivity 0.88 (0.80 to 0.94) / specificity 0.90 (0.86 to 0.93), and at 28/29 for impairment 0.90 / 0.90; scores uninfluenced by education. TYPE SET PRINTED ON THE FACE: typed Editorial at PubMed alongside Clinical Trial, Phase II / Validation Study — counted on its described design
Study: Phase II diagnostic-accuracy validation study (primary report) — dedicated; type set includes Editorial alongside Clinical Trial, Phase II / Validation Study, printed on the face and counted on substance
Population: A phase II cross-sectional validation sample of 308 patients referred to a general neurology department plus 70 healthy individuals (total: 225 without cognitive impairment, 58 with impairment without dementia, 95 with dementia); Phototest accuracy assessed against clinical diagnosis and compared with the Eurotest and a verbal fluency test. Programme-labelled: the Carnero group's own report.
Summary: Phase-II validation — the dedicated derivation study (Carnero Pardo 2007, Neurologia — 308 neurology referrals + 70 healthy subjects: 225 without impairment, 58 with impairment without dementia, 95 with dementia): Phototest aROC 0.95 ± 0.01 for both dementia and cognitive impairment, similar to the Eurotest's and above verbal fluency's; at cut-off 25/26 for dementia sensitivity 0.88 (0.80 to 0.94) / specificity 0.90 (0.86 to 0.93), and at 28/29 for impairment 0.90 / 0.90; scores uninfluenced by education. TYPE SET PRINTED ON THE FACE: typed Editorial at PubMed alongside Clinical Trial, Phase II / Validation Study — counted on its described design
Result: Phototest results were normally distributed in unimpaired subjects (33.4 ± 3.9) and were not influenced by educational variables. Diagnostic accuracy (aROC) was 0.95 ± 0.01 for both dementia and cognitive impairment, similar to the Eurotest's and higher than verbal fluency's for both. Cut-offs maximising sensitivity plus specificity were 25/26 for dementia (Se 0.88 [0.80–0.94], Sp 0.90 [0.86–0.93]) and 28/29 for impairment (Se 0.90, Sp 0.90), as published.
Watch out: The 70 healthy controls are not clinic spectrum — they widen the contrast and flatter the aROC; the clinic-only performance is better read from the phase-III limbs. The Editorial typing is printed, not hidden: the count rests on the study design the abstract describes in full.
Source: Carnero Pardo et al. [Diagnostic accuracy of the Phototest for cognitive impairment and dementia]. Neurologia (Barcelona, Spain). 2007. PMID: 18040903. Registry ID: none in the record. MeSH: Aged · Cognition Disorders/diagnosis · Cross-Sectional Studies · Dementia/diagnosis · Diagnostic Techniques, Neurological · Female · Humans · Male · Reproducibility of Results
Card 2 — Phase-III three-test study — PHOTOTEST LIMB of a SHARED report (Carnero-Pardo 2011, PLoS One — 139 primary-care patients with suspected impairment: 47 dementia, 36 cognitive impairment, 56 none): for dementia, κ = 0.70 (0.57 to 0.82) and diagnostic accuracy 0.86 (0.79 to 0.91); for cognitive impairment, κ = 0.59 and accuracy 0.79 — the cheapest of the three tests for impairment screening, and the fastest (2.8 ± 0.8 min). SHARED REPORT PRINTED AS SHARED: carded here for its Phototest limb and on pack #8128 for its Eurotest limb
Study: Phase III diagnostic-accuracy study (primary report) — SHARED report by row direction: Phototest limb here, Eurotest limb on pack #8128; printed as shared
Population: 139 individuals with suspicion of cognitive impairment or dementia in four primary-care centres, all given the Eurotest, Memory Alteration Test (M@T) and Phototest in balanced order, with an independent blinded gold-standard diagnosis by expert-neurologist consensus. This card reports the study for its Phototest limb only.
Summary: Phase-III three-test study — PHOTOTEST LIMB of a SHARED report (Carnero-Pardo 2011, PLoS One — 139 primary-care patients with suspected impairment: 47 dementia, 36 cognitive impairment, 56 none): for dementia, κ = 0.70 (0.57 to 0.82) and diagnostic accuracy 0.86 (0.79 to 0.91); for cognitive impairment, κ = 0.59 and accuracy 0.79 — the cheapest of the three tests for impairment screening, and the fastest (2.8 ± 0.8 min). SHARED REPORT PRINTED AS SHARED: carded here for its Phototest limb and on pack #8128 for its Eurotest limb
Result: No significant differences in effectiveness were found among the tests. For dementia screening the Phototest gave κ = 0.70 (0.57–0.82) and diagnostic accuracy 0.86 (0.79–0.91); for cognitive-impairment screening, κ = 0.59 and accuracy 0.79. The cost of cognitive-impairment screening did not differ from the Eurotest's, and application time was shortest for the Phototest (2.8 ± 0.8 min vs 7.1 ± 1.8 for the Eurotest), as published.
Watch out: κ and accuracy against a consensus diagnosis are agreement measures, not a fresh sensitivity/specificity pair — do not restate them as such. The impairment limb (κ = 0.59, accuracy 0.79) is materially weaker than the dementia limb and prints beside it.
Source: Carnero-Pardo et al. Diagnostic accuracy, effectiveness and cost for cognitive impairment and dementia screening of three short cognitive tests applicable to illiterates. PloS one. 2011. PMID: 22073256. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Cognition Disorders/diagnosis/economics · Dementia/diagnosis/economics · Educational Status · Female · Humans · Male · Middle Aged · Sensitivity and Specificity
Card 3 — Phase-III eight-test study — PHOTOTEST (Fototest) LIMB of a SHARED report (Carnero-Pardo 2022, Neurologia — 141 primary-care patients with suspected impairment, 86 with cognitive impairment): Fototest AUC 0.87 ± 0.03, not significantly different from the Eurotest (0.91 ± 0.02) or M@T, with administration under half the Eurotest's (2.8 minutes). SHARED REPORT PRINTED AS SHARED: carded here for its Phototest limb and on pack #8128 for its Eurotest limb. Its duplicate record PMID 31402066 is the same study and is REFUSED — only this record (35504802) is carded
Study: Phase III diagnostic-accuracy study (primary report) — SHARED report by row direction: Phototest limb here, Eurotest limb on pack #8128; duplicate record 31402066 refused, printed on the face
Population: 141 individuals with suspected cognitive impairment in primary care, all completing eight brief tests (MMSE, MEC, SPMSQ, MIS, Clock Drawing Test, Eurotest, Fototest and M@T), with cognitive impairment diagnosed independently by researchers blinded to test scores. This card reports the study for its Fototest limb only.
Summary: Phase-III eight-test study — PHOTOTEST (Fototest) LIMB of a SHARED report (Carnero-Pardo 2022, Neurologia — 141 primary-care patients with suspected impairment, 86 with cognitive impairment): Fototest AUC 0.87 ± 0.03, not significantly different from the Eurotest (0.91 ± 0.02) or M@T, with administration under half the Eurotest's (2.8 minutes). SHARED REPORT PRINTED AS SHARED: carded here for its Phototest limb and on pack #8128 for its Eurotest limb. Its duplicate record PMID 31402066 is the same study and is REFUSED — only this record (35504802) is carded
Result: The Eurotest and M@T (AUC 0.91 ± 0.02 and 0.90 ± 0.02) performed significantly better than the MMSE, MEC, SPMSQ and Clock Drawing Test, but not compared with MIS or Fototest (both AUC 0.87 ± 0.03); Fototest took less than half as long to administer (2.8 [0.8] min) as the Eurotest or M@T. The authors list the Eurotest, M@T and Fototest as the most advisable primary-care screening tests, with Fototest the most efficient, as published.
Watch out: The AUC gap to the Eurotest (0.87 vs 0.91) was not significant in this 141-patient sample — 'not significantly different' is not 'equal', and the efficiency claim (half the time) is the limb's firmest finding. The target is cognitive impairment, not dementia alone.
Source: Carnero-Pardo et al. Diagnostic performance of brief cognitive tests in cognitive impairment screening. Neurologia. 2022. PMID: 35504802. Registry ID: none in the record. MeSH: Alzheimer Disease/diagnosis · Cognition Disorders/diagnosis · Cognitive Dysfunction/diagnosis · Dementia/diagnosis · Humans · Mass Screening · Neuropsychological Tests
Card 4 — Synthesis (3 reports — 1 dedicated + 2 shared phase-III limbs, printed as shared): the Phototest identifies dementia and cognitive impairment with aROC 0.95 in its phase-II validation (cut-offs 25/26 and 28/29, sensitivity/specificity ≈0.88–0.90/0.90) and holds up inside both shared phase-III comparisons (dementia accuracy 0.86; impairment AUC 0.87) while taking under 3 minutes — the briefest instrument in its comparison set; its evidence base is one programme's derivation plus shared limbs, and no non-Spanish validation is in the carded base
Study: Synthesis
Population: Synthesis of the 3 reports carded above: phase-II validation (308 referrals + 70 healthy controls), phase-III three-test study (139, shared — Phototest limb) and phase-III eight-test study (141, shared — Phototest limb). The shared studies are also carded on pack #8128 for their Eurotest limbs; the duplicate record PMID 31402066 was refused.
Summary: Synthesis (3 reports — 1 dedicated + 2 shared phase-III limbs, printed as shared): the Phototest identifies dementia and cognitive impairment with aROC 0.95 in its phase-II validation (cut-offs 25/26 and 28/29, sensitivity/specificity ≈0.88–0.90/0.90) and holds up inside both shared phase-III comparisons (dementia accuracy 0.86; impairment AUC 0.87) while taking under 3 minutes — the briefest instrument in its comparison set; its evidence base is one programme's derivation plus shared limbs, and no non-Spanish validation is in the carded base
Result: Dementia: aROC 0.95 ± 0.01, Se 0.88 / Sp 0.90 at 25/26 (phase II); accuracy 0.86, κ = 0.70 (phase III). Cognitive impairment: aROC 0.95 ± 0.01, Se 0.90 / Sp 0.90 at 28/29 (phase II); accuracy 0.79, κ = 0.59 (2011); AUC 0.87 ± 0.03 (2022). Education: scores uninfluenced by educational variables in the derivation sample. Time: <3 minutes by design; 2.8 minutes measured in both phase-III studies.
Watch out: Never cite the phase-II aROC of 0.95 without its spectrum (referrals plus healthy controls), and never count the shared studies as Phototest-only validations — the composition (1 dedicated + 2 shared) is the shelf's stated basis.
Source: Synthesis of the reports carded above; no additional source.