SourceMed · Shelf #8130 in the ask interface

MASA swallowing assessment: good concurrent validity against endoscopy in acute stroke (AUC 0.85 dysphagia, 0.84 aspiration) but the original cut-offs gave specificity of only 0.16 — a locally optimal cut-off of ≤146 restored balance (0.71 / 0.81); Italian and Turkish validations show strong reliability — 3 reports

Shelf #8130 · Brain, stroke & mind

MEASUREMENT PROPERTIES / PREDICTIVE PERFORMANCE — MASA total score vs endoscopic severity (FEDSS) in acute stroke (n = 151): AUC 0.85 for dysphagia and 0.84 for aspiration risk; at the ORIGINAL cut-offs sensitivity was 1.00 with specificity 0.16 (dysphagia) / 0.43 (aspiration) — the original operating point is NOT ESTABLISHED as usable in this spectrum — while a locally derived cut-off of ≤146 gave 0.71 / 0.81 and 0.73 / 0.80; the score also predicted pneumonia (AUC 0.85 in hospital, 0.86 at 1 year) and mortality (0.79); reliability ESTABLISHED in translation validations (Italian α 0.86–0.89, inter-rater ICC 0.98, intra-rater 0.99; Turkish α 0.899–0.901) with endoscopic concurrent validity only moderate in the Turkish study (r ≈ −0.32)

Stamped: 2026-11-28.

Evidence published: 2018–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the MASA (Mann Assessment of Swallowing Ability — a 24-item standardised clinical swallowing examination scored to 200, developed as a diagnostic test for oropharyngeal dysphagia and aspiration in early stroke) — what concurrent and predictive validity and what cut-offs did the Belgian acute-stroke study find against endoscopic severity grading, and what reliability and concurrent validity did the Italian and Turkish post-stroke validations establish?

Balance of the evidence

This is a measurement-properties shelf — no treatment claim. Cut-offs migrate by spectrum and print with their cohorts: the original cut-offs (<178 dysphagia, <170 aspiration) gave perfect sensitivity with inadequate specificity (0.16 / 0.43) in the Belgian cohort, while the locally optimal ≤146 gave 0.71 / 0.81 and 0.73 / 0.80 — the original cut-offs' specificity prints beside their perfect sensitivity wherever they appear. Concurrent validity against scales and against endoscopy are different claims: the Italian version's strong correlations are with other clinical scales (DOSS r = 0.949; De Pippo r = −0.783), while the Turkish version's correlation with endoscopic evaluation is only moderate (r ≈ −0.32) — both print. The Belgian report is labelled a secondary analysis on its card. The cancer variants are different instruments and are not counted: MASA-C (head-and-neck cancer) and MASA-OC (Chinese oral-cancer revision). The original MASA validation (Mann, 2002) was not returned by the mining desk's searches and is not carded — the shelf stands on the three reports above, printed as such. Distinct from the homed swallow screens (#7780, #7786, #7817, #7818) and occupied SSQ (#8110) / RSST (#8111): the MASA is a full clinical examination, not a screen; cross-points at build.

MeSH: Humans · Deglutition · Deglutition Disorders/diagnosis/etiology · Follow-Up Studies · Cohort Studies · Belgium · Pneumonia/complications/diagnosis · Stroke/complications/diagnosis

Cards (4)

Card 1 — Belgian acute-stroke study — labelled a secondary analysis (Simpelaere 2024, Folia phoniatrica et logopaedica — 151 acute-stroke patients against the FEDSS endoscopic scale): MASA total score AUC 0.85 for dysphagia and 0.84 for aspiration risk; at the original cut-offs (<178 / <170) sensitivity was 1.00 with specificity 0.16 (dysphagia) / 0.43 (aspiration); at the locally optimal cut-off of ≤146, sensitivity / specificity were 0.71 / 0.81 (dysphagia) and 0.73 / 0.80 (aspiration); the score predicted pneumonia (AUC 0.85 in hospital, 0.86 at 1 year) and mortality (AUC 0.79)

Study: Concurrent- and predictive-validity study (primary report) — labelled a secondary analysis by its authors, printed as such; the shelf's only endoscopy-referenced accuracy report

Population: 151 patients from a Belgian acute-stroke cohort; the MASA total score (sum of weighted scores on 24 items) was evaluated against the Fiberoptic Endoscopic Dysphagia Severity Scale (FEDSS) for concurrent validity, and against pneumonia during hospitalisation and over 1 year and mortality for predictive validity. Labelled a secondary data analysis by its authors.

Summary: Belgian acute-stroke study — labelled a secondary analysis (Simpelaere 2024, Folia phoniatrica et logopaedica — 151 acute-stroke patients against the FEDSS endoscopic scale): MASA total score AUC 0.85 for dysphagia and 0.84 for aspiration risk; at the original cut-offs (<178 / <170) sensitivity was 1.00 with specificity 0.16 (dysphagia) / 0.43 (aspiration); at the locally optimal cut-off of ≤146, sensitivity / specificity were 0.71 / 0.81 (dysphagia) and 0.73 / 0.80 (aspiration); the score predicted pneumonia (AUC 0.85 in hospital, 0.86 at 1 year) and mortality (AUC 0.79)

Result: Diagnostic accuracy of the MASA total score was good for dysphagia (AUC = 0.85) and relevant aspiration risk (AUC = 0.84). Using the original cutoff scores, sensitivity was perfect (Se = 1.00) for dysphagia and aspiration but specificity was inadequate (Sp = 0.16 for dysphagia, 0.43 for aspiration). At the newly determined optimal cutoff of ≤146 for both, sensitivity / specificity were 0.71 / 0.81 (dysphagia) and 0.73 / 0.80 (aspiration). The score significantly predicted pneumonia during hospitalisation (AUC = 0.85) and at 1-year follow-up (0.86) and mortality (0.79), as published.

Watch out: Cut-off migration is the headline: a cut-off derived in the same cohort (≤146) will perform worse elsewhere, and the original cut-offs' 0.16 specificity means they flag nearly everyone in this spectrum. Predictive AUCs for pneumonia/mortality are associations from the same cohort, not validated prediction models.

Source: Simpelaere et al. Concurrent and Predictive Validity of the Mann Assessment of Swallowing Ability in Belgian Acute Stroke Patients Based on a 1-Year Follow-Up Study. Folia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP). 2024. PMID: 37666223. Registry ID: none in the record. MeSH: Humans · Deglutition · Deglutition Disorders/diagnosis/etiology · Follow-Up Studies · Cohort Studies · Belgium · Pneumonia/complications/diagnosis · Stroke/complications/diagnosis

Card 2 — Italian version psychometrics (Sterbini 2024, Brain sciences — 78 post-stroke participants): internal consistency α 0.86–0.89, inter-rater ICC 0.98, intra-rater ICC 0.99; concurrent correlation with the DOSS scale r = 0.949 and with the De Pippo 3-ounce test r = −0.783

Study: Psychometric validation study (primary report) — reliability and scale-concurrent validity; no endoscopic reference in this report

Population: 78 post-stroke individuals assessed with the Italian translation of the MASA (MASA-IT), culturally adapted following international guidelines; concurrent validity examined against the Italian versions of the Dysphagia Outcome Severity Scale (DOSS) and the De Pippo Test — Three Oz Water Swallow.

Summary: Italian version psychometrics (Sterbini 2024, Brain sciences — 78 post-stroke participants): internal consistency α 0.86–0.89, inter-rater ICC 0.98, intra-rater ICC 0.99; concurrent correlation with the DOSS scale r = 0.949 and with the De Pippo 3-ounce test r = −0.783

Result: Items showed excellent internal consistency (Cronbach's alpha 0.86–0.89). Inter-rater ICC was 0.98 and intra-rater ICC 0.99, indicating high reproducibility. The MASA-IT correlated strongly and directly with the DOSS (r = 0.949, p = 0.01) and inversely with the De Pippo Test (r = −0.783, p = 0.01), confirming good concurrent validity against those scales, as published. The record carries no MeSH terms (printed on the source line).

Watch out: Agreement with other bedside scales (DOSS, De Pippo) is not accuracy against endoscopy — two clinical scales can agree and both be wrong against the reference standard. This card establishes that the Italian version is reproducible and scale-consistent, nothing more.

Source: Sterbini et al. Evaluation of Psychometric Proprieties of Mann Assessment of Swallowing Ability (MASA) in Italian Language: A Cross-Sectional Study. Brain sciences. 2024. PMID: 39335396. Registry ID: none in the record. MeSH: none in the record

Card 3 — Turkish version psychometrics (Karaca Umay 2018, Turkish journal of medical sciences — 141 early-post-stroke patients): internal consistency α 0.899–0.901 with excellent inter-rater agreement; correlation with endoscopic evaluation for dysphagia presence only moderate (r ≈ −0.32, both raters, P = 0.001), at an accepted cut-off of 169 points

Study: Psychometric validation study (primary report) — reliability plus endoscopic convergent validity (moderate), printed at its measured strength

Population: 141 patients in the early period after stroke, scored by two blinded independent expert observers with the Turkish MASA (T-MASA); reliability by internal consistency and inter-rater agreement, validity by convergent methods including correlation with endoscopic evaluation; the T-MASA cut-off for dysphagia was accepted as 169 points.

Summary: Turkish version psychometrics (Karaca Umay 2018, Turkish journal of medical sciences — 141 early-post-stroke patients): internal consistency α 0.899–0.901 with excellent inter-rater agreement; correlation with endoscopic evaluation for dysphagia presence only moderate (r ≈ −0.32, both raters, P = 0.001), at an accepted cut-off of 169 points

Result: The T-MASA showed good internal consistency (Cronbach's alpha 0.899–0.901) and corrected item-to-total correlations, with intraclass correlation coefficients indicating excellent agreement. A significant moderate negative correlation was found between endoscopic evaluation and the T-MASA for the presence of dysphagia (r: −0.324 and −0.302 for the two raters, both P = 0.001). The authors conclude the Turkish version is valid and reliable for determining dysphagia early after stroke, as published. The record carries no MeSH terms (printed on the source line).

Watch out: The honest contrast of this shelf: against endoscopy the Turkish version correlates at only r ≈ −0.32, far below the Italian version's scale-to-scale r = 0.949 — print both, labelled by what each was measured against. A third cut-off (169) in a third cohort further confirms that MASA operating points are cohort-specific.

Source: Karaca Umay et al. The psychometric evaluation of the Turkish version of the Mann Assessment of Swallowing Ability in patients in the early period after stroke. Turkish journal of medical sciences. 2018. PMID: 30541241. Registry ID: none in the record. MeSH: none in the record

Card 4 — Synthesis (3 reports): the MASA is a reproducible clinical swallowing examination (α ≈0.86–0.90, ICCs 0.98–0.99 in translation validations) with good endoscopy-referenced discrimination in acute stroke (AUC 0.85 / 0.84) — but its operating point is unsettled: original cut-offs gave specificity of 0.16 in the Belgian cohort, local optima differ by cohort (≤146 Belgian; 169 Turkish), and endoscopic concurrent validity was only moderate (r ≈ −0.32) where it was directly measured in the Turkish study

Study: Synthesis

Population: Synthesis of the 3 reports carded above: Belgian acute-stroke validity study (151, secondary analysis), Italian psychometric validation (78) and Turkish psychometric validation (141) — all post-stroke populations; the original Mann (2002) validation is not in the carded base.

Summary: Synthesis (3 reports): the MASA is a reproducible clinical swallowing examination (α ≈0.86–0.90, ICCs 0.98–0.99 in translation validations) with good endoscopy-referenced discrimination in acute stroke (AUC 0.85 / 0.84) — but its operating point is unsettled: original cut-offs gave specificity of 0.16 in the Belgian cohort, local optima differ by cohort (≤146 Belgian; 169 Turkish), and endoscopic concurrent validity was only moderate (r ≈ −0.32) where it was directly measured in the Turkish study

Result: Accuracy: AUC 0.85 (dysphagia) and 0.84 (aspiration) vs FEDSS; original cut-offs Se 1.00 / Sp 0.16–0.43; local cut-off ≤146 Se/Sp 0.71/0.81 and 0.73/0.80; pneumonia prediction AUC 0.85–0.86, mortality 0.79. Reliability: α 0.86–0.89 (Italian), 0.899–0.901 (Turkish); ICC 0.98 inter-rater, 0.99 intra-rater (Italian). Concurrent validity: r = 0.949 vs DOSS and −0.783 vs De Pippo (scales); r ≈ −0.32 vs endoscopy (Turkish).

Watch out: Never quote a MASA cut-off without its cohort: three reports use three different operating points (<178/<170 original, ≤146, 169), and sensitivity/specificity pairs do not travel between them.

Source: Synthesis of the reports carded above; no additional source.