JHFRAT fall-risk tool: AUC 0.67 and PPV 4% in 17,263 admissions; most medicine-service fallers scored moderate / low risk — 2 numeric + 2 qualitative reports
Shelf #8143 · Geriatrics, frailty & deprescribing
PREDICTIVE PERFORMANCE — weak discrimination established: Dutch external validation (n = 17,263) AUC 0.67 with sensitivity 73% / specificity 51% and PPV 4% at 2.5% prevalence; a majority of medicine-service fallers had been classified moderate or low risk; derived cut-offs migrate (11–12 in stroke rehabilitation); composition 2 numeric + 2 qualitative reports, printed on the face
Stamped: 2026-11-28.
Evidence published: 2017–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How well does the JHFRAT (Johns Hopkins Fall Risk Assessment Tool — seven weighted categories including age, fall history, elimination, medication, patient-care equipment, mobility and cognition, scored 0–35 with medium risk from 6 and high risk from 14) predict falls in hospitalised adults — what reliability and validity did its psychometric study find, what discrimination did the 17,263-admission Dutch external validation find, how did it perform on inpatient medicine services, and what cut-off did the stroke-rehabilitation validation derive? Composition: 2 numeric + 2 qualitative reports.
Balance of the evidence
COMPOSITION PRINTED ON THE FACE: 2 numeric reports (the Dutch external validation and the stroke-rehabilitation study) + 2 qualitative reports (the psychometric study and the medicine-services study — neither prints an accuracy pair in its abstract, and none may be printed from them). The row's numeric spine is the Dutch validation. This is a prediction shelf: the PPV of 4% at a 2.5% fall prevalence is the honest headline and prints beside the sensitivity. Derived cut-offs migrate by setting (the tool's own bands — medium from 6, high from 14 — vs 11–12 derived in stroke rehabilitation) and print with their cohorts. The stroke study's handgrip limb is a subgrouping variable only; no grip figure is taken from it. Distinct from the Morse, STRATIFY and Hendrich II shelves — the hospital falls-risk ring's fourth instrument; the rows cross-point.
MeSH: Accidental Falls/prevention & control · Adult · Female · Humans · Inpatients · Male · Middle Aged · Psychometrics/statistics & numerical data · Reproducibility of Results · Risk Assessment/methods · Surveys and Questionnaires
Cards (5)
Card 1 — Psychometric study (Poe 2018, Journal of Nursing Care Quality — acute care): the tool was reliable with high sensitivity and negative predictive validity and lower-than-expected specificity and positive predictive validity — reported qualitatively in its abstract; no numeric pair may be printed from it
Study: Psychometric study (primary report) — qualitative anchor, printed as such
Population: Adult inpatients in acute care settings assessed with the Johns Hopkins Fall Risk Assessment Tool, developed to facilitate early detection of risk for anticipated physiologic falls; this study sought to establish psychometric properties not yet fully established. Its abstract as fetched reports no sample size and no coefficients, and none are printed here.
Summary: Psychometric study (Poe 2018, Journal of Nursing Care Quality — acute care): the tool was reliable with high sensitivity and negative predictive validity and lower-than-expected specificity and positive predictive validity — reported qualitatively in its abstract; no numeric pair may be printed from it
Result: Results indicate that the JHFRAT is reliable, with high sensitivity and negative predictive validity. Specificity and positive predictive validity were lower than expected. (Stated qualitatively, as published — this report's abstract prints no numeric accuracy pair.)
Watch out: Qualitative limb of the 2 numeric + 2 qualitative composition: 'high sensitivity' here is the authors' characterisation without a printed pair, and no number may be attached to it. The Dutch validation's measured pair (73% / 51%) is the shelf's numeric statement of the same pattern.
Source: Poe et al. The Johns Hopkins Fall Risk Assessment Tool: A Study of Reliability and Validity.. Journal of nursing care quality. 2018. PMID: 28968337. Registry ID: none in the record. MeSH: Accidental Falls/prevention & control · Adult · Female · Humans · Inpatients · Male · Middle Aged · Psychometrics/statistics & numerical data · Reproducibility of Results · Risk Assessment/methods · Surveys and Questionnaires
Card 2 — Dutch external validation (Damoiseaux-Volman 2023, European Geriatric Medicine — EHR data, 17,263 admissions of patients ≥70, fall prevalence 2.5%): at >5 (medium / high risk) sensitivity 73%, specificity 51%, PPV 4%, NPV 99%, overall AUC 0.67 (6-monthly AUCs 0.62–0.71), with seasonal influenza affecting the association
Study: External validation (primary report) — the composition's principal numeric anchor
Population: 17,263 admissions of hospitalised patients aged ≥70 (median age 76, 47% female) admitted for ≥24 hours between 2016 and 2021, with at least one JHFRAT measurement in the electronic health record; in-hospital falls (prevalence 2.5%) were extracted from structured and free-text data.
Summary: Dutch external validation (Damoiseaux-Volman 2023, European Geriatric Medicine — EHR data, 17,263 admissions of patients ≥70, fall prevalence 2.5%): at >5 (medium / high risk) sensitivity 73%, specificity 51%, PPV 4%, NPV 99%, overall AUC 0.67 (6-monthly AUCs 0.62–0.71), with seasonal influenza affecting the association
Result: The JHFRAT was significantly associated with falls (odds ratio 1.11 (1.03 to 1.20), labelled as such), as were its subcategories. For medium / high risk (score >5), sensitivity was 73%, specificity 51%, PPV 4% and NPV 99%. Overall discrimination was AUC 0.67, varying between 0.62 and 0.71 across 6-month intervals, with over-prediction in calibration; seasonal influenza affected the association, while COVID-19 and season did not. The authors conclude discrimination is low in older inpatients and improvements in fall-risk assessment are warranted, as published.
Watch out: PPV 4% at 2.5% prevalence is the honest headline: 96 of every 100 patients flagged medium / high risk did not fall. The association (odds ratio 1.11) and the discrimination (AUC 0.67) are both weak-to-modest and print together.
Source: Damoiseaux-Volman et al. External validation of the Johns Hopkins Fall Risk Assessment Tool in older Dutch hospitalized patients.. European geriatric medicine. 2023. PMID: 36422821. Registry ID: none in the record. MeSH: Humans · Female · Aged · Influenza, Human · Reproducibility of Results · COVID-19/epidemiology · Risk Assessment/methods · Inpatients
Card 3 — Medicine-services validity study (Klinkenberg 2017, Journal of Nursing Care Quality — 13,574 admissions with 204 falls): fallers had higher total scores, but a majority of patients who fell had been classified moderate or low risk — its abstract reports no accuracy pair and none may be printed from it
Study: Validity study (primary report) — qualitative anchor, printed as such
Population: 13,574 patient admissions to medicine units at a large academic medical centre in 2014, with 204 reported patient falls, examined for the predictive validity of the widely used JHFRAT.
Summary: Medicine-services validity study (Klinkenberg 2017, Journal of Nursing Care Quality — 13,574 admissions with 204 falls): fallers had higher total scores, but a majority of patients who fell had been classified moderate or low risk — its abstract reports no accuracy pair and none may be printed from it
Result: While patients who fell had higher JHFRAT total scores, a majority of patients who fell were classified by the JHFRAT as moderate or low risk. (Stated as published — this report's abstract prints no sensitivity / specificity pair.)
Watch out: Qualitative limb: the majority-of-fallers finding is the clinically operative statement — the tool's own risk bands missed most eventual fallers on medicine services. No pair may be reconstructed from it.
Source: Klinkenberg et al. Validity of the Johns Hopkins Fall Risk Assessment Tool for Predicting Falls on Inpatient Medicine Services.. Journal of nursing care quality. 2017. PMID: 27482875. Registry ID: none in the record. MeSH: Accidental Falls/prevention & control/statistics & numerical data · Humans · Inpatients/statistics & numerical data · Patients' Rooms/standards · Reproducibility of Results · Risk Assessment/methods/standards
Card 4 — Stroke-rehabilitation validation (Hong 2024, Healthcare — 175 patients ≥65): optimal cut-off 11 (sensitivity 67%, specificity 68%) overall and 12 (75% / 72%) in the low-handgrip-strength subgroup — the handgrip limb is a subgrouping variable only; no grip figure is taken from it
Study: Predictive-validity study (primary report) — derived cut-offs print with their cohort
Population: 175 patients aged ≥65 with subacute stroke transferred to the rehabilitation ward of a university hospital, analysed retrospectively for fall frequency (6.9% overall) and the JHFRAT's predictive validity by ROC analysis with Youden-index thresholds; a subgroup with low unaffected handgrip strength (135 of 175 patients) was analysed separately.
Summary: Stroke-rehabilitation validation (Hong 2024, Healthcare — 175 patients ≥65): optimal cut-off 11 (sensitivity 67%, specificity 68%) overall and 12 (75% / 72%) in the low-handgrip-strength subgroup — the handgrip limb is a subgrouping variable only; no grip figure is taken from it
Result: The JHFRAT's predictive value was acceptable in both the overall cohort and the low-handgrip subgroup, and higher in the subgroup. The optimal cut-off for the overall cohort was 11 (sensitivity 67%, specificity 68%); for the low-handgrip subgroup it was 12 (sensitivity 75%, specificity 72%). The authors expect the results to aid nurses in rehabilitation wards in using JHFRAT outcomes for older post-stroke patients, as published.
Watch out: Derived cut-offs migrate: 11–12 in stroke rehabilitation vs the tool's own bands (medium from 6, high from 14) — a rehabilitation-derived threshold never prints as the tool's general threshold. Handgrip appears only as the subgrouping variable; no grip figure is printed, per the standing fence.
Source: Hong et al. Predictive Validity of the Johns Hopkins Fall Risk Assessment Tool for Older Patients in Stroke Rehabilitation.. Healthcare (Basel, Switzerland). 2024. PMID: 38610213. Registry ID: none in the record. MeSH: none in the record
Card 5 — Synthesis (4 reports — composition: 2 numeric + 2 qualitative anchors): the JHFRAT is associated with falls but discriminates weakly — AUC 0.67 in 17,263 older admissions, with sensitivity 73% / specificity 51% and a PPV of only 4% at 2.5% prevalence; on medicine services most fallers had been classified moderate or low risk; stroke rehabilitation derived higher cut-offs (11–12) with pairs of 67% / 68% and 75% / 72%
Study: Synthesis
Population: Synthesis of the 4 reports carded above (psychometric study — qualitative, N not stated in its abstract; Dutch external validation n = 17,263 admissions; medicine-services study n = 13,574 admissions, 204 falls; stroke-rehabilitation study n = 175).
Summary: Synthesis (4 reports — composition: 2 numeric + 2 qualitative anchors): the JHFRAT is associated with falls but discriminates weakly — AUC 0.67 in 17,263 older admissions, with sensitivity 73% / specificity 51% and a PPV of only 4% at 2.5% prevalence; on medicine services most fallers had been classified moderate or low risk; stroke rehabilitation derived higher cut-offs (11–12) with pairs of 67% / 68% and 75% / 72%
Result: The numeric spine is the Dutch validation: odds ratio 1.11 (1.03 to 1.20) per the score's association with falls (labelled as such), AUC 0.67 (6-monthly 0.62–0.71), and at >5 sensitivity 73%, specificity 51%, PPV 4%, NPV 99%. The qualitative anchors agree in direction: high sensitivity with lower-than-expected specificity and PPV (psychometric study), and a majority of medicine-service fallers classified moderate or low risk. Rehabilitation cut-offs (11 overall, 12 in the low-handgrip subgroup) sit far above the tool's medium-risk band (from 6).
Watch out: Composition restated: 2 numeric + 2 qualitative reports — the qualitative findings print as findings, never with reconstructed numbers. The PPV of 4% prints beside any sensitivity quoted from this shelf.
Source: Synthesis of the reports carded above; no additional source.