Downton Fall Risk Index: largely negative evidence — AUC 0.6 and 'little utility' in the largest accuracy study; only a post-discharge injury association is positive (3 reports)

Shelf #8144 · Geriatrics, frailty & deprescribing

PREDICTIVE PERFORMANCE — NOT ESTABLISHED for in-hospital falls: the largest accuracy study found AUC 0.6 (0.48 to 0.72) and concluded little utility; the registry study's likelihood ratios were 1.55 / 0.67; the only positive limb is a post-discharge fall-related-injury association (incidence rate ratio 1.94) carried by 2 of 5 modules — a different claim, printed as such; evidence largely negative, printed unsoftened

Stamped: 2026-11-28.

Evidence published: 2017–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How well does the Downton Fall Risk Index (five modules — previous falls, medication, sensory deficits, mental state and gait — scored 0–11, increased risk at ≥3) predict falls — what diagnostic validity did the Andalusian multicentre longitudinal study find against STRATIFY, what accuracy did the Cartagena hospital study calculate, and how did the index predict fall-related injury after discharge in the Stockholm cohort?

Balance of the evidence

The verified evidence for this instrument is LARGELY NEGATIVE and prints as such, unsoftened: the largest accuracy study found AUC 0.6 and concluded the index showed little utility; the second accuracy study's likelihood ratios (1.55 / 0.67) are weak. This shelf exists because the instrument is in wide use and its measured performance is the answer. The post-discharge injury association (incidence rate ratio 1.94, labelled as such) is an association with a composite outcome over six months after discharge — it is NOT in-hospital fall discrimination, and the two claims never merge. Only two of the index's five modules (previous falls, unsafe gait) carried the Stockholm signal, and they print at module level. The Cartagena study's sampling frame is patients who fell, with its comparison constructed from the fall registry — a design caveat that prints with its figures. Distinct from the STRATIFY shelf (a comparator inside the first anchor) and the JHFRAT shelf: three hospital falls instruments with three different evidence shapes; the rows cross-point.

MeSH: Accidental Falls/prevention & control/statistics & numerical data · Acute Disease/therapy · Hospitalization · Humans · Incidence · Inpatients/statistics & numerical data · Longitudinal Studies · Patient Discharge · ROC Curve · Risk Assessment/methods

Cards (4)

Card 1 — Andalusian multicentre longitudinal study (Aranda-Gallardo 2017, BMC Health Services Research — 977 patients completing follow-up, 24 falls): Downton AUC 0.6 (0.48 to 0.72), and at cut-off 2 sensitivity 66.7% / specificity 55.3% — the authors conclude both Downton and STRATIFY (AUC 0.69) showed little utility

Study: Prospective multicentre accuracy study (primary report) — STRATIFY limb prints as comparator

Population: 977 patients (of 1,247 recruited) completing all follow-up assessments in acute-care hospitals in the Andalusian public health system, assessed with the Downton and STRATIFY instruments within 24 hours of admission and every 72 hours until discharge; 23 patients (2.35%) suffered 24 falls.

Summary: Andalusian multicentre longitudinal study (Aranda-Gallardo 2017, BMC Health Services Research — 977 patients completing follow-up, 24 falls): Downton AUC 0.6 (0.48 to 0.72), and at cut-off 2 sensitivity 66.7% / specificity 55.3% — the authors conclude both Downton and STRATIFY (AUC 0.69) showed little utility

Result: ROC analysis showed the optimal cut-off for each instrument was below that described by its authors: AUC for STRATIFY was 0.69 (95% CI 0.57 to 0.8) and for Downton 0.6 (0.48 to 0.72). At a cut-off point of 2, Downton presented sensitivity 66.7% and specificity 55.3% (STRATIFY at cut-off 1: 47.6% / 85%). The authors conclude both instruments presented little utility as means of detecting the risk of falls among acute-care inpatients, and that fall prevention should be based on individual risk factors, as published.

Watch out: Negative evidence, printed unsoftened: an AUC of 0.6 whose confidence interval (0.48 to 0.72) includes chance, on only 24 falls. The derived optimal cut-off (2) is below the index's own increased-risk threshold (≥3) — the migration prints.

Source: Aranda-Gallardo et al. Diagnostic validity of the STRATIFY and Downton instruments for evaluating the risk of falls by hospitalised acute-care patients: a multicentre longitudinal study.. BMC health services research. 2017. PMID: 28412939. Registry ID: none in the record. MeSH: Accidental Falls/prevention & control/statistics & numerical data · Acute Disease/therapy · Hospitalization · Humans · Incidence · Inpatients/statistics & numerical data · Longitudinal Studies · Patient Discharge · ROC Curve · Risk Assessment/methods

Card 2 — Cartagena hospital study (Bueno-García 2017, Enfermería Clínica — retrospective study of recorded falls, 469 fallers analysed): sensitivity 0.58, specificity 0.62, positive likelihood ratio 1.55, negative 0.67 and odds ratio 2.31 (all labelled as such) — its sampling frame is patients who fell, with the comparison constructed from the fall registry

Study: Retrospective registry study (primary report) — faller-based sampling frame, printed as a design caveat

Population: A retrospective descriptive study of falls recorded at a Cartagena public hospital (March 2010 to March 2015): 576 patients fell during the period, of whom 107 were recorded in the no-fall-risk registry, leaving a sample of 469 patients analysed for the Downton scale's characteristics and fall profiles.

Summary: Cartagena hospital study (Bueno-García 2017, Enfermería Clínica — retrospective study of recorded falls, 469 fallers analysed): sensitivity 0.58, specificity 0.62, positive likelihood ratio 1.55, negative 0.67 and odds ratio 2.31 (all labelled as such) — its sampling frame is patients who fell, with the comparison constructed from the fall registry

Result: In the context in which the assessment was made, the Downton scale had sensitivity 0.58, specificity 0.62, a positive likelihood ratio of 1.55 and a negative likelihood ratio of 0.67 (both labelled as likelihood ratios as published); the odds ratio calculated was 2.31 (labelled as such). The recorded fall incidence (0.51%) was similar to other studies. The authors conclude the poor scores should serve as a wake-up call for healthcare institutions, as published.

Watch out: Design caveat prints with the figures: the sampling frame is patients who fell, with the comparison constructed from the fall registry — these are not prospective accuracy estimates. Even taken at face value, likelihood ratios of 1.55 / 0.67 barely move a pre-test probability.

Source: Bueno-García et al. Characteristics of the Downton fall risk assessment scale in hospitalised patients.. Enfermeria clinica. 2017. PMID: 28400165. Registry ID: none in the record. MeSH: Accidental Falls/statistics & numerical data · Adult · Aged · Aged, 80 and over · Female · Hospitalization · Humans · Male · Middle Aged · Retrospective Studies · Risk Assessment/methods · Sensitivity and Specificity · Young Adult

Card 3 — Stockholm post-discharge cohort (Mojtaba 2018, Journal of Physiotherapy — 6,650 hospitalised patients over 65 followed 6 months after discharge): a score ≥3 was associated with fall-related injury at an incidence rate ratio of 1.94 (1.60 to 2.38) (labelled as such), driven by the previous-falls (2.58) and unsafe-gait (1.79) modules — an association with a composite outcome, not in-hospital fall discrimination

Study: Prospective prognostic-association cohort (primary report) — different claim from fall discrimination, printed as such

Population: 6,650 patients aged over 65 admitted to three Stockholm geriatric clinics in 2012 who survived the admission and lived in the region, with Downton scores collected before discharge and fall-related injuries collected for up to 6 months after discharge; Poisson multivariate regression adjusted for confounders.

Summary: Stockholm post-discharge cohort (Mojtaba 2018, Journal of Physiotherapy — 6,650 hospitalised patients over 65 followed 6 months after discharge): a score ≥3 was associated with fall-related injury at an incidence rate ratio of 1.94 (1.60 to 2.38) (labelled as such), driven by the previous-falls (2.58) and unsafe-gait (1.79) modules — an association with a composite outcome, not in-hospital fall discrimination

Result: The cut-off of ≥3 points was significantly associated with fall-related injury after adjustment (incidence rate ratio 1.94, 95% CI 1.60 to 2.38). Among the five individual modules, only previous falls (incidence rate ratio 2.58, 2.22 to 3.01) and unsafe gait (1.79, 1.53 to 2.09) were associated with fall-related injuries; the medication, sensory-deficit and mental-state modules were not. The authors conclude that, although the tool is predictive of post-discharge injury, previous falls and gait are the measures most worthy of focus, as published.

Watch out: Claim separation is absolute: this is an adjusted association with fall-related INJURY after discharge, not discrimination of in-hospital falls, and it never rescues the accuracy limbs. Three of five modules carried no signal — the index's predictive content here is two history / examination items.

Source: Mojtaba et al. Downton Fall Risk Index during hospitalisation is associated with fall-related injuries after discharge: a longitudinal observational study.. Journal of physiotherapy. 2018. PMID: 29914804. Registry ID: none in the record. MeSH: Accidental Falls/statistics & numerical data · Aged · Female · Geriatric Assessment · Hospitalization · Humans · Longitudinal Studies · Male · Patient Discharge · Predictive Value of Tests · Prospective Studies · Risk Factors · Sweden

Card 4 — Synthesis (3 reports): for predicting in-hospital falls the Downton index's verified performance is poor — AUC 0.6 (0.48 to 0.72) with 'little utility' in the prospective multicentre study, and likelihood ratios of 1.55 / 0.67 in the registry study; its one positive limb, a post-discharge fall-related-injury association (incidence rate ratio 1.94), is a different claim carried by only two of its five modules (previous falls 2.58, unsafe gait 1.79)

Study: Synthesis

Population: Synthesis of the 3 reports carded above (prospective multicentre accuracy study n = 977 completing follow-up, 24 falls; retrospective fall-registry study, 469 fallers analysed; prospective post-discharge cohort n = 6,650).

Summary: Synthesis (3 reports): for predicting in-hospital falls the Downton index's verified performance is poor — AUC 0.6 (0.48 to 0.72) with 'little utility' in the prospective multicentre study, and likelihood ratios of 1.55 / 0.67 in the registry study; its one positive limb, a post-discharge fall-related-injury association (incidence rate ratio 1.94), is a different claim carried by only two of its five modules (previous falls 2.58, unsafe gait 1.79)

Result: In-hospital fall prediction: AUC 0.6 (0.48 to 0.72) with sensitivity 66.7% / specificity 55.3% at a derived cut-off of 2 (prospective), and sensitivity 0.58 / specificity 0.62 with likelihood ratios +1.55 / −0.67 and an odds ratio of 2.31 (retrospective, faller-based frame) — all labelled as published. Post-discharge: score ≥3 associated with fall-related injury at an incidence rate ratio of 1.94 (1.60 to 2.38), driven by the previous-falls (2.58) and unsafe-gait (1.79) modules only. Read together, the index does not discriminate in-hospital falls usefully; what signal exists after discharge is two items, not the five-module score.

Watch out: Largely negative evidence, restated unsoftened: the injury association never converts into fall-prediction accuracy, and no card may present the 1.94 figure as validation of the index as a falls screen.

Source: Synthesis of the reports carded above; no additional source.