SourceMed · Shelf #8147 in the ask interface
LCADL — London Chest Activity of Daily Living scale: ICC 0.93 in severe COPD (test–retest n = 19), responsive to rehabilitation, extended to heart failure — 3 reports
Shelf #8147 · Lungs, breathing & sleep
MEASUREMENT PROPERTIES — supported in severe COPD, extended to heart failure: test–retest ICC 0.93 (n = 19) and 0.87–0.98 (n = 191) in COPD, reproducibility 0.98 in heart failure; responsive to rehabilitation with the domestic domain not responding; smallest detectable change 4.5 (total); composition 3 primaries (original validity report not carded) counted as such; a measurement stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2002–2015.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the LCADL (London Chest Activity of Daily Living scale — 15 items across self-care, domestic, physical and leisure domains rating breathlessness during everyday activities, scored 0–75) — what reliability and responsiveness did its COPD evaluation find, how did it perform in heart failure, and what did the Dutch severe-COPD validation establish?
Balance of the evidence
Composition prints on the face: 3 primary reports — the programme's reliability-and-responsiveness evaluation in severe COPD, a heart-failure extension validation, and the Dutch severe-COPD validation. The original LCADL validity report (Garrod, 2000) is referenced inside the first anchor as prior work and is not carded — this shelf stands on the three reports above, printed as such. A measurement-properties shelf, not a rehabilitation-treatment shelf. The reliability anchor's test–retest N is 19 and prints on the face. The heart-failure report extends the instrument beyond its COPD home population and prints as an extension. Domain scores behave differently (the domestic domain did not respond to rehabilitation in the COPD evaluation) and print by domain, not only as totals. Further language validations (Turkish; asthma; Portuguese heart-failure) were returned at candidate level at mining and are corroboration, not counted. Cross-points in prose only: SOBQ (occupied #8117), MDP (#8146 — activity-free episode rating; the LCADL rates breathlessness during named daily activities) and the Mahler BDI/TDI (#8148).
MeSH: Activities of Daily Living · Adult · Aged · Aged, 80 and over · Dyspnea/diagnosis,physiopathology · Health Status Indicators · Humans · Middle Aged · Pulmonary Disease, Chronic Obstructive/physiopathology · Reproducibility of Results · Sensitivity and Specificity · Statistics, Nonparametric · Surveys and Questionnaires/standards · Dyspnea/physiopathology,psychology · Exercise Test · Exercise Tolerance/physiology · Female · Heart Failure/physiopathology,psychology · Male · Quality of Life · Respiratory Function Tests · Surveys and Questionnaires · Ventricular Dysfunction, Left/physiopathology · Comorbidity · Disability Evaluation · Netherlands · Severity of Illness Index · Translating
Cards (4)
Card 1 — Reliability and responsiveness evaluation in severe COPD (Garrod 2002, Respiratory Medicine — test–retest in 19 stable patients, responsiveness in 59 after rehabilitation): test–retest ICC 0.93 (0.82 to 0.97) and a significant post-rehabilitation total-score improvement (mean difference −5.91 (−9.23 to −2.60)) — labelled the programme's follow-on evaluation; small test–retest N (19) prints on the face
Study: Evaluation study (primary report) — programme follow-on evaluation; test–retest N = 19 prints
Population: Reliability was assessed in 19 patients with stable severe COPD (median age 66 (55–79) years, FEV1 mean 0.91 (SD 0.29) L) by test–retest 4 weeks apart; responsiveness was assessed in 59 patients (median age 66 (38–84), FEV1 mean 0.87 (SD 0.30) L) who had undergone at least 6 weeks of pulmonary rehabilitation.
Summary: Reliability and responsiveness evaluation in severe COPD (Garrod 2002, Respiratory Medicine — test–retest in 19 stable patients, responsiveness in 59 after rehabilitation): test–retest ICC 0.93 (0.82 to 0.97) and a significant post-rehabilitation total-score improvement (mean difference −5.91 (−9.23 to −2.60)) — labelled the programme's follow-on evaluation; small test–retest N (19) prints on the face
Result: Test–retest scores showed a strong relationship, ICC 0.93 (95% CI 0.82 to 0.97). With the exception of the Domestic component, all domains showed a statistically significant reduction in dyspnoea during activities of daily living after pulmonary rehabilitation, and the total LCADL score improved significantly (mean difference −5.91 (95% CI −9.23 to −2.60)), as published. The authors had previously reported the scale's validity; this report evaluates its reliability and responsiveness.
Watch out: The reliability coefficient rests on 19 patients; the domestic domain's non-response to rehabilitation prints beside the total-score responsiveness — domains are not interchangeable.
Source: Garrod et al. An evaluation of the reliability and sensitivity of the London Chest Activity of Daily Living Scale (LCADL). Respiratory medicine. 2002. PMID: 12243319. Registry ID: none in the record. MeSH: Activities of Daily Living · Adult · Aged · Aged, 80 and over · Dyspnea/diagnosis,physiopathology · Health Status Indicators · Humans · Middle Aged · Pulmonary Disease, Chronic Obstructive/physiopathology · Reproducibility of Results · Sensitivity and Specificity · Statistics, Nonparametric · Surveys and Questionnaires/standards
Card 2 — Heart-failure validation (Carvalho 2010, Journal of Rehabilitation Medicine — 47 patients with heart failure): correlation with the MLHFQ r = 0.88, reproducibility 0.98, and score separation between NYHA classes I vs II / III but not II vs III — an extension beyond the scale's COPD home population, printed as such
Study: Validation study (primary report) — heart-failure extension population
Population: 47 patients with heart failure (57% male, mean age 50 (SD 9) years, mean left ventricular ejection fraction 29% (SD 6), NYHA functional class I–III); all performed a cardiopulmonary exercise test and completed the LCADL and the Minnesota Living with Heart Failure Questionnaire, with the LCADL re-test applied one week later.
Summary: Heart-failure validation (Carvalho 2010, Journal of Rehabilitation Medicine — 47 patients with heart failure): correlation with the MLHFQ r = 0.88, reproducibility 0.98, and score separation between NYHA classes I vs II / III but not II vs III — an extension beyond the scale's COPD home population, printed as such
Result: The LCADL correlated with the MLHFQ (r = 0.88; p < 0.0001); both correlated with exercise capacity (r = −0.75 and −0.73). The LCADL was reproducible (0.98). LCADL scores differed significantly between NYHA classes I and II and between I and III, but not between classes II and III, as published.
Watch out: Extension population: a dyspnoea-during-ADL scale developed in COPD, validated here in younger heart-failure patients (mean age 50) — its coefficients print as the heart-failure version's evidence, and the II-vs-III non-separation prints beside the correlations.
Source: Carvalho et al. Validation of the London Chest Activity of Daily Living scale in patients with heart failure. Journal of rehabilitation medicine. 2010. PMID: 20809052. Registry ID: none in the record. MeSH: Activities of Daily Living · Dyspnea/physiopathology,psychology · Exercise Test · Exercise Tolerance/physiology · Female · Heart Failure/physiopathology,psychology · Humans · Male · Middle Aged · Quality of Life · Reproducibility of Results · Respiratory Function Tests · Surveys and Questionnaires · Ventricular Dysfunction, Left/physiopathology
Card 3 — Dutch validation in severe COPD (Klijn 2015, Medicine — 191 patients): correlations with the SGRQ r = 0.24 to 0.64, test–retest ICC 0.87–0.98, and smallest detectable changes of 4.5 (total) and 2.2–4.9 (domains)
Study: Validation study (primary report) — Dutch version, severe COPD
Population: 191 patients with COPD (70 male; age 62 ± 9 years; FEV1 33 ± 10% predicted) in whom construct validity was assessed against disease-specific health status, generic functional status and functional and peak exercise capacity; the LCADL was completed twice for test–retest reliability and responsiveness was assessed after 8 to 12 weeks of inpatient pulmonary rehabilitation.
Summary: Dutch validation in severe COPD (Klijn 2015, Medicine — 191 patients): correlations with the SGRQ r = 0.24 to 0.64, test–retest ICC 0.87–0.98, and smallest detectable changes of 4.5 (total) and 2.2–4.9 (domains)
Result: The LCADL correlated significantly with the St. George Respiratory Questionnaire (r = 0.24 to 0.64), functional status (r = 0.45 to 0.82), walking distance (r = −0.3 to −0.58) and peak work rate. Test–retest reliability was high (ICC 0.87 to 0.98). The smallest detectable change for the total score was 4.5, and for the self-care, domestic, physical and leisure domains 2.9, 3.3, 4.9 and 2.2 respectively. Improvement after rehabilitation correlated significantly with improvement in the Chronic Respiratory Questionnaire (−0.43; P < 0.001), as published.
Watch out: Convergent correlations with the SGRQ run as low as 0.24 for some domains — the range prints, not only its top; the smallest detectable change (4.5 total) is a measurement-error figure, not a minimal important difference.
Source: Klijn et al. Validity, Reliability, and Responsiveness of the Dutch Version of the London Chest Activity of Daily Living Scale in Patients With Severe COPD. Medicine. 2015. PMID: 26656349. Registry ID: none in the record. MeSH: Activities of Daily Living · Aged · Comorbidity · Disability Evaluation · Female · Humans · Male · Middle Aged · Netherlands · Pulmonary Disease, Chronic Obstructive/physiopathology · Reproducibility of Results · Respiratory Function Tests · Severity of Illness Index · Translating
Card 4 — Synthesis: the LCADL is reliable (ICC 0.93 in 19 severe-COPD patients; 0.87–0.98 in 191 Dutch patients; reproducibility 0.98 in heart failure) and responsive to rehabilitation, with domain-level behaviour and a heart-failure extension that prints separately
Study: Synthesis
Population: Synthesis of the 3 reports carded above (19 + 59 patients in the COPD evaluation, 47 heart-failure patients, 191 Dutch severe-COPD patients). The original LCADL validity report (Garrod, 2000) is not carded.
Summary: Synthesis: the LCADL is reliable (ICC 0.93 in 19 severe-COPD patients; 0.87–0.98 in 191 Dutch patients; reproducibility 0.98 in heart failure) and responsive to rehabilitation, with domain-level behaviour and a heart-failure extension that prints separately
Result: The verified set holds: test–retest ICC 0.93 (0.82 to 0.97) over 4 weeks in severe COPD and 0.87–0.98 across total and domain scores in the Dutch validation; reproducibility 0.98 at 1 week in heart failure with an MLHFQ correlation of 0.88 but no NYHA II-vs-III separation; responsiveness to pulmonary rehabilitation in both COPD reports (total-score mean difference −5.91 in the programme evaluation), with the domestic domain not responding in the programme evaluation; and Dutch smallest detectable changes of 4.5 (total) and 2.2–4.9 (domains). No pooled coefficient is printed: populations (COPD vs heart failure) and versions print separately.
Watch out: Composition discipline: 3 primaries, no derivation carded. Cross-points in prose only: SOBQ (#8117), MDP (#8146), Mahler BDI/TDI (#8148).
Source: Synthesis of the reports carded above; no additional source.