SourceMed · Shelf #8150 in the ask interface
BFI — Brief Fatigue Inventory: unidimensional and consistent (α 0.94–0.96) in cancer only, with a 35% floor effect in hospitalised chemotherapy — 4 reports
Shelf #8150 · Cancer
MEASUREMENT PROPERTIES — supported in cancer populations only: unidimensional in derivation and validations; α 0.94–0.96; test–retest 0.87–0.91; 35% floor effect in hospitalised chemotherapy patients; no anchor validates the BFI outside cancer; composition 4 primaries counted as such; a measurement stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1999–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the BFI (Brief Fatigue Inventory — nine items: three fatigue-severity ratings (now / usual / worst in the past 24 hours) and six interference ratings, each 0–10) — what did its original rapid-assessment study in 305 cancer patients establish, and what reliability and validity did the Indonesian, Taiwanese and hospitalised-chemotherapy clinimetric studies find?
Balance of the evidence
Composition prints on the face: 4 primary reports (the original rapid-assessment study and Indonesian, Taiwanese and hospitalised-chemotherapy clinimetric validations). A measurement-properties shelf, not a fatigue-treatment shelf. The evidence base is exclusively oncological — no anchor validates the BFI outside cancer, and no card presents its coefficients as general-population performance. The floor effect (35% at the lowest score in hospitalised chemotherapy patients) prints beside the reliability figures. Severity and interference subscores print separately where reported. The Piper Fatigue Scale appears inside the fourth anchor as a comparator — the Piper's own shelf is #8154, on different reports. Cross-points: the fatigue ring cross-points in prose only: FSS (#8149), BFI (#8150), MFI-20 (#8151), FACIT-Fatigue (#8152), Chalder Fatigue Scale (#8153) and revised Piper Fatigue Scale (#8154) — each instrument has its own derivation tradition and no coefficient transfers between them.
MeSH: Case-Control Studies · Factor Analysis, Statistical · Fatigue/etiology,psychology · Female · Humans · Male · Neoplasms/complications,psychology · Quality of Life · Reproducibility of Results · Severity of Illness Index · Surveys and Questionnaires · Adult · Aged · Cross-Sectional Studies · Discriminant Analysis · Fatigue/diagnosis,epidemiology,etiology · Indonesia · Middle Aged · Neoplasm Staging · Neoplasms/complications,diagnosis,epidemiology,pathology · Prevalence · Psychometrics · Socioeconomic Factors · Young Adult · Fatigue/diagnosis,etiology · Health Status Indicators · Neoplasms/complications · Sensitivity and Specificity · Taiwan · Aged, 80 and over · Antineoplastic Agents/adverse effects,therapeutic use · Fatigue/chemically induced,diagnosis · Inpatients · Neoplasms/drug therapy,psychology · Reference Values
Cards (5)
Card 1 — Original rapid-assessment study (Mendoza 1999, Cancer — 305 cancer patients plus 290 community adults): a single severity dimension, internal stability, high correlations with similar fatigue measures, >98% completion, and a score range defining severe fatigue — programme-labelled: the Mendoza / Cleeland group's own report
Study: Original study (primary report) — programme-labelled (Mendoza / Cleeland group)
Population: 305 consecutive consenting adult inpatients and outpatients with cancer who could understand and complete the self-report measures; the same instruments were administered to 290 community-dwelling adults as a comparison sample, with research staff rating ECOG performance status and pain characteristics.
Summary: Original rapid-assessment study (Mendoza 1999, Cancer — 305 cancer patients plus 290 community adults): a single severity dimension, internal stability, high correlations with similar fatigue measures, >98% completion, and a score range defining severe fatigue — programme-labelled: the Mendoza / Cleeland group's own report
Result: The BFI was shown to be an internally stable (reliable) measure that tapped a single dimension, best interpreted as severity of fatigue. It correlated highly with similar fatigue measures. Greater than 98% of patients were able to complete it. A range of scores defining severe fatigue was identified, as published. No Cronbach alpha value is printed in the abstract and none is printed here.
Watch out: Programme report: the derivation's claims are qualitative in its abstract (internal stability, single dimension) — the numeric reliability spine of this shelf comes from the validations below.
Source: Mendoza et al. The rapid assessment of fatigue severity in cancer patients: use of the Brief Fatigue Inventory. Cancer. 1999. PMID: 10091805. Registry ID: none in the record. MeSH: Case-Control Studies · Factor Analysis, Statistical · Fatigue/etiology,psychology · Female · Humans · Male · Neoplasms/complications,psychology · Quality of Life · Reproducibility of Results · Severity of Illness Index · Surveys and Questionnaires
Card 2 — Indonesian validation (Paramita 2016, Journal of Pain and Symptom Management — 121 cancer outpatients): α 0.956, one-factor structure, inverse correlations with all SF-36 domains (r = −0.388 to −0.676) and scores rising with ECOG performance status
Study: Validation study (primary report) — Indonesian version in cancer outpatients
Population: 121 consecutive adult outpatients with cancer who completed the Indonesian BFI (developed by forward and backward translation with cognitive debriefing) together with the MOS SF-36; demographic and health data were collected.
Summary: Indonesian validation (Paramita 2016, Journal of Pain and Symptom Management — 121 cancer outpatients): α 0.956, one-factor structure, inverse correlations with all SF-36 domains (r = −0.388 to −0.676) and scores rising with ECOG performance status
Result: The Indonesian BFI had an overall Cronbach's alpha for the nine items of 0.956. Factor analysis suggested a one-factor solution, supporting unidimensionality. An expected inverse correlation between the Indonesian BFI and all domains of the MOS SF-36 was observed (r = −0.388 to −0.676). Discriminant validity analysis showed the mean score increased significantly with increasing ECOG Performance Status values, as published.
Watch out: Cancer-only evidence: the ECOG gradient is a known-groups finding inside oncology and does not extend the instrument beyond cancer populations.
Source: Paramita et al. Validity and Reliability of the Indonesian Version of the Brief Fatigue Inventory in Cancer Patients. Journal of pain and symptom management. 2016. PMID: 27660081. Registry ID: none in the record. MeSH: Adult · Aged · Cross-Sectional Studies · Discriminant Analysis · Factor Analysis, Statistical · Fatigue/diagnosis,epidemiology,etiology · Female · Humans · Indonesia · Male · Middle Aged · Neoplasm Staging · Neoplasms/complications,diagnosis,epidemiology,pathology · Prevalence · Psychometrics · Quality of Life · Reproducibility of Results · Severity of Illness Index · Socioeconomic Factors · Surveys and Questionnaires · Young Adult
Card 3 — Taiwanese validation (Lin 2006, Journal of Pain and Symptom Management — 439 patients with varied cancers): α 0.96 (severity) / 0.95 (interference), test–retest 0.89 / 0.91, one-factor structure and known-group validity
Study: Validation study (primary report) — Taiwanese version
Population: 439 Taiwanese patients with multiple cancer diagnoses; convergent validity was examined against POMS vigor and fatigue subscales, known-group validity by functional status and inpatient / outpatient status, and sensitivity in a subsample of 20 breast-cancer patients before, during and after chemotherapy.
Summary: Taiwanese validation (Lin 2006, Journal of Pain and Symptom Management — 439 patients with varied cancers): α 0.96 (severity) / 0.95 (interference), test–retest 0.89 / 0.91, one-factor structure and known-group validity
Result: Internal consistency was indicated by Cronbach alphas of 0.96 for fatigue-related severity and 0.95 for interference. Test–retest reliability was 0.89 for fatigue severity and 0.91 for interference. Factor analysis revealed a one-factor structure. Known-group validity was established, and the BFI-T was sensitive to change across chemotherapy in the subsample, as published.
Watch out: Severity and interference print as separate subscores (α 0.96 / 0.95; test–retest 0.89 / 0.91) — a single merged BFI reliability figure would misstate both.
Source: Lin et al. Validation of the Taiwanese version of the Brief Fatigue Inventory. Journal of pain and symptom management. 2006. PMID: 16824985. Registry ID: none in the record. MeSH: Adult · Aged · Cross-Sectional Studies · Fatigue/diagnosis,etiology · Female · Health Status Indicators · Humans · Male · Middle Aged · Neoplasms/complications · Psychometrics · Reproducibility of Results · Sensitivity and Specificity · Taiwan
Card 4 — Clinimetric study in hospitalised chemotherapy patients (Nunes 2019, Journal of Pain and Symptom Management — 100 patients): α 0.94, ICC 0.87 (0.81 to 0.91), correlation with the Piper Fatigue Scale r = 0.84, moderate internal responsiveness (effect size 0.5), absent external responsiveness and a 35% floor effect
Study: Clinimetric validation study (primary report) — hospitalised chemotherapy population
Population: 100 oncological patients hospitalised for chemotherapy in a test–retest study; the BFI was applied on the first day of chemotherapy and 48 hours and 15 days after chemotherapy started, with internal consistency, reliability, agreement, construct validity against the Piper Fatigue Scale, responsiveness, and ceiling and floor effects assessed.
Summary: Clinimetric study in hospitalised chemotherapy patients (Nunes 2019, Journal of Pain and Symptom Management — 100 patients): α 0.94, ICC 0.87 (0.81 to 0.91), correlation with the Piper Fatigue Scale r = 0.84, moderate internal responsiveness (effect size 0.5), absent external responsiveness and a 35% floor effect
Result: The BFI presented adequate internal consistency (Cronbach's alpha 0.94), substantial reliability (ICC 0.87 (95% CI 0.81 to 0.91)) and very good agreement. It correlated positively and strongly with the Piper Fatigue Scale (r = 0.84; P < 0.001). Internal responsiveness was moderate (effect size 0.5) and external responsiveness was absent. A floor effect was present (35%), as published.
Watch out: The 35% floor effect prints beside the reliability figures: in this population a third of patients sit at the scale's minimum, where it cannot register worsening or improvement below that point. The Piper limb is a comparator here; the Piper's own shelf is #8154.
Source: Nunes et al. Clinimetric Properties of the Brief Fatigue Inventory Applied to Oncological Patients Hospitalized for Chemotherapy. Journal of pain and symptom management. 2019. PMID: 30391653. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Antineoplastic Agents/adverse effects,therapeutic use · Fatigue/chemically induced,diagnosis · Female · Humans · Inpatients · Male · Middle Aged · Neoplasms/drug therapy,psychology · Reference Values · Reproducibility of Results
Card 5 — Synthesis: in an exclusively cancer evidence base the BFI is a unidimensional, internally consistent (α 0.94–0.96) rapid fatigue measure with test–retest 0.87–0.91 — and a 35% floor effect where patients are hospitalised for chemotherapy
Study: Synthesis
Population: Synthesis of the 4 reports carded above (305 cancer patients + 290 community adults in the derivation; 121 Indonesian, 439 Taiwanese and 100 hospitalised-chemotherapy patients in the validations).
Summary: Synthesis: in an exclusively cancer evidence base the BFI is a unidimensional, internally consistent (α 0.94–0.96) rapid fatigue measure with test–retest 0.87–0.91 — and a 35% floor effect where patients are hospitalised for chemotherapy
Result: The verified set holds: a single severity dimension with >98% completion in the derivation; α 0.956 with a one-factor structure and SF-36 inverse correlations in Indonesian outpatients; α 0.96 / 0.95 and test–retest 0.89 / 0.91 for severity / interference in Taiwanese patients; and α 0.94 with ICC 0.87 (0.81 to 0.91), a Piper correlation of 0.84, moderate internal but absent external responsiveness, and a 35% floor effect in hospitalised chemotherapy patients. No coefficient is presented as general-population performance: every anchor is an oncology sample.
Watch out: Composition discipline: 4 primaries, all in cancer populations. Cross-points: the fatigue ring cross-points in prose only: FSS (#8149), BFI (#8150), MFI-20 (#8151), FACIT-Fatigue (#8152), Chalder Fatigue Scale (#8153) and revised Piper Fatigue Scale (#8154) — each instrument has its own derivation tradition and no coefficient transfers between them.
Source: Synthesis of the reports carded above; no additional source.