SourceMed · Shelf #8166 in the ask interface
NEADL: reliable (α/ICC up to 0.97) but fails Guttman scaling and under-responds after hip replacement — 4 reports, one shared
Shelf #8166 · Geriatrics, frailty & deprescribing
MEASUREMENT PROPERTIES — reliable with printed limits: subscale α 0.72–0.94 and test–retest r 0.81–0.90 in MS (n=240) and total α/ICC 0.97 in healthy Turkish elderly (n=60) — but NOT a Guttman scale in MS (scalability 0.3), responsiveness poor after hip replacement, and random error 0.6 ± 5.6 in chronic stroke (shared four-scale report, NEADL limb; typed as a trial at PubMed, counted on substance as a reliability study)
Stamped: 2026-11-28.
Evidence published: 2001–2008.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the NEADL (Nottingham Extended Activities of Daily Living scale — 22 items across mobility, kitchen, domestic and leisure sections) — what reliability and validity did it show in multiple sclerosis and after total hip replacement, what did the Turkish version establish in healthy older adults, and how did it perform in the four-scale stroke test–retest study?
Balance of the evidence
Composition prints on the face: 4 reports across four spectra (MS / arthroplasty / healthy elderly / chronic stroke — populations print). ROW-DIRECTED SHARING + TYPE FLAG (printed on the face as directed): PMID 11720117 cards on this pack (NEADL limb), on #8167 (Frenchay limb) and on #8179 (Rivermead limb) — one report, a different instrument's limb on each, stated on every face; it is typed Clinical Trial / Randomized Controlled Trial at PubMed although its described design is a reliability study, counted on substance with the flag printed. A measurement-properties shelf. Negative limbs print: Guttman failure in MS and poor responsiveness after hip replacement stand beside the high α/ICC coefficients. The hip-replacement record states no sample N in its abstract — 'N not documented' prints on its card. Cross-points in prose only: #8163, #8167.
MeSH: Activities of Daily Living · Adult · Disability Evaluation · Factor Analysis, Statistical · Female · Humans · Male · Middle Aged · Multiple Sclerosis/physiopathology · Nervous System/physiopathology · Quality of Life · Randomized Controlled Trials as Topic · Reproducibility of Results · Single-Blind Method · Surveys and Questionnaires · Activities of Daily Living/classification · Aged · Aged, 80 and over · Arthroplasty, Replacement, Hip/rehabilitation · Health Status Indicators · Psychometrics · Recovery of Function · Self Efficacy · Geriatric Assessment/methods · Turkey · Persons with Disabilities/classification,rehabilitation · Psychomotor Performance · Range of Motion, Articular · Severity of Illness Index · Stroke/diagnosis · Stroke Rehabilitation
Cards (5)
Card 1 — Multiple sclerosis study 2002 (Multiple sclerosis — 240 MS patients, questionnaires four months apart, recruited through an RCT of cognitive assessment — the sampling frame prints): subscale α 0.72–0.94 and test–retest r 0.81–0.90, but items did NOT form a Guttman scale (reproducibility 0.8, scalability 0.3) and quality-of-life correlations were weak, as published
Study: Validation study (primary report) — MS spectrum; Guttman failure printed
Population: 240 patients with multiple sclerosis recruited through a randomised controlled trial of cognitive assessment and treatment in MS (sampling frame printed as such); the Nottingham Extended ADL Scale, Guy's Neurological Disability Scale and SF-36 were administered on two occasions four months apart.
Summary: Multiple sclerosis study 2002 (Multiple sclerosis — 240 MS patients, questionnaires four months apart, recruited through an RCT of cognitive assessment — the sampling frame prints): subscale α 0.72–0.94 and test–retest r 0.81–0.90, but items did NOT form a Guttman scale (reproducibility 0.8, scalability 0.3) and quality-of-life correlations were weak, as published
Result: The EADL items did not form a Guttman Scale (coefficient of reproducibility 0.8, coefficient of scalability 0.3). The EADL and its four subscales all had high internal consistency (alpha 0.72–0.94). Test–retest reliability was satisfactory (r(s) 0.81–0.90) with a mean difference of 0.29 between occasions. Factor analysis generally supported the subscale structure. There were significant but weak correlations with quality-of-life measures. The authors conclude the scale shows promise in MS but its item range needs extending, as published.
Watch out: Negative limb prints: the scale fails Guttman scaling in MS (scalability 0.3) — its α/ICC-style coefficients may not be printed without that failure. Sampling frame is an RCT's recruited cohort, printed as such; the four-month interval mixes stability with real change.
Source: Nicholl et al. The reliability and validity of the Nottingham Extended Activities of Daily Living Scale in patients with multiple sclerosis.. Multiple sclerosis (Houndmills, Basingstoke, England). 2002. PMID: 12356202. Registry ID: none in the record. MeSH: Activities of Daily Living · Adult · Disability Evaluation · Factor Analysis, Statistical · Female · Humans · Male · Middle Aged · Multiple Sclerosis/physiopathology · Nervous System/physiopathology · Quality of Life · Randomized Controlled Trials as Topic · Reproducibility of Results · Single-Blind Method · Surveys and Questionnaires
Card 2 — Total hip replacement study 2002 (Disability and rehabilitation — measured pre-operatively and at 3 and 6 months; sample N not documented in the abstract, printed as such): approximately unidimensional, reliable and valid against SF-36 / London Handicap Scale, but responsiveness POOR compared with both, underestimating health gain after arthroplasty, as published
Study: Validation study (primary report) — arthroplasty spectrum; responsiveness failure printed; N not documented in the record
Population: Patients undergoing total hip replacement, with the Extended ADL scale measured before operation and at 3 and 6 months after arthroplasty, compared with the SF-36 and London Handicap Scale (the abstract does not state the sample N — N not documented, printed as such; a subsample was retested for reliability).
Summary: Total hip replacement study 2002 (Disability and rehabilitation — measured pre-operatively and at 3 and 6 months; sample N not documented in the abstract, printed as such): approximately unidimensional, reliable and valid against SF-36 / London Handicap Scale, but responsiveness POOR compared with both, underestimating health gain after arthroplasty, as published
Result: The sub-scales and total score were approximately unidimensional on factor analysis and Cronbach's alpha, but did not form an adequate hierarchical (Guttman) scale. Associations with other scales were in the expected direction and of approximately the expected strength, supporting concurrent and construct validity. Reliability was good. Responsiveness was poor compared with the other scales, and the scale underestimates the size of health gain after hip arthroplasty compared with them, as published.
Watch out: Negative limb prints: responsiveness poor — a reliable scale that misses real improvement after hip replacement. No coefficients are printed from this record beyond its qualitative findings, because its abstract reports none numerically. N not documented: no denominator may be supplied from elsewhere.
Source: Harwood et al. The validity, reliability and responsiveness of the Nottingham Extended Activities of Daily Living scale in patients undergoing total hip replacement.. Disability and rehabilitation. 2002. PMID: 12022787. Registry ID: none in the record. MeSH: Activities of Daily Living/classification · Adult · Aged · Aged, 80 and over · Arthroplasty, Replacement, Hip/rehabilitation · Factor Analysis, Statistical · Female · Health Status Indicators · Humans · Male · Middle Aged · Psychometrics · Recovery of Function · Reproducibility of Results · Self Efficacy
Card 3 — Turkish version 2008 (Aging clinical and experimental research — 60 healthy volunteers over 67; its spectrum is healthy volunteers, printed as such): total α 0.97, test–retest ICC 0.97 and correlation with the Modified Barthel Index r=0.84, as published
Study: Translation validation study (primary report) — HEALTHY-volunteer spectrum, printed as such
Population: 60 healthy volunteers over 67 years old (mean age 77 ± 5.67 years) in Turkey; the Turkish NEADL was completed over a 2-week period, with internal consistency, test–retest ICC and Spearman correlation assessed, and convergent validity against the Modified Barthel Index.
Summary: Turkish version 2008 (Aging clinical and experimental research — 60 healthy volunteers over 67; its spectrum is healthy volunteers, printed as such): total α 0.97, test–retest ICC 0.97 and correlation with the Modified Barthel Index r=0.84, as published
Result: Internal consistency within subsections and items was good to very good (Cronbach's alpha 0.84–0.93 and 0.74–0.97 respectively), with total-score alpha 0.97. Test–retest ICC was 0.97 for the total score (0.84–0.97 between items). The NEADL total score correlated with the Modified Barthel Index at r = 0.84 (p < 0.0001). The authors conclude the Turkish version is reliable and valid for ADL assessment of Turkish elderly persons, as published.
Watch out: Healthy-volunteer spectrum: α/ICC of 0.97 in people without disability do not establish performance in patients — the spectrum prints beside the coefficients, never underneath them.
Source: Sahin et al. Reliability and validity of the Turkish version of the Nottingham Extended Activities of Daily Living Scale.. Aging clinical and experimental research. 2008. PMID: 19039280. Registry ID: none in the record. MeSH: Activities of Daily Living · Aged · Aged, 80 and over · Disability Evaluation · Female · Geriatric Assessment/methods · Humans · Male · Reproducibility of Results · Turkey
Card 4 — Four-scale stroke test–retest study 2001 (Disability and rehabilitation — 22 patients over a year post-stroke, one-week interval): NEADL mean difference 0.6 ± 5.6 — a larger random-error component than Barthel or Rivermead in the same patients, as published. TYPE FLAG (printed on the face): this report is typed Clinical Trial / Randomized Controlled Trial at PubMed although its described design is a reliability study nested in no randomised intervention; it is counted on substance. SHARED REPORT (printed as shared): its Frenchay limb is carded on pack #8167 and its Rivermead limb on pack #8179 — a different instrument's limb on each
Study: Test–retest reliability study (primary report) — SHARED report by row direction (NEADL limb here; Frenchay limb on #8167, Rivermead limb on #8179), printed as shared; TYPE FLAG: typed Clinical Trial / Randomized Controlled Trial at PubMed, counted on substance as a reliability study
Population: 22 patients more than 1 year post-stroke, tested twice at an interval of 1 week with the Barthel Index, the Rivermead Mobility Index, the Nottingham Extended ADL Scale and the Frenchay Activities Index. This card reports the study for its NEADL limb; the report is shared by row direction across three packs (#8166 NEADL limb, #8167 Frenchay limb, #8179 Rivermead limb), stated here because the composition governs every figure from it.
Summary: Four-scale stroke test–retest study 2001 (Disability and rehabilitation — 22 patients over a year post-stroke, one-week interval): NEADL mean difference 0.6 ± 5.6 — a larger random-error component than Barthel or Rivermead in the same patients, as published. TYPE FLAG (printed on the face): this report is typed Clinical Trial / Randomized Controlled Trial at PubMed although its described design is a reliability study nested in no randomised intervention; it is counted on substance. SHARED REPORT (printed as shared): its Frenchay limb is carded on pack #8167 and its Rivermead limb on pack #8179 — a different instrument's limb on each
Result: Mean differences and reliability coefficients (random error) were: Barthel 0.4 ± 2.0, Rivermead 0.3 ± 2.2, NEADL 0.6 ± 5.6 and Frenchay −0.6 ± 7.1. There was little bias between assessments; the Barthel and Rivermead performed better with lower random error, while the NEADL and Frenchay did not perform as well, having larger random-error components. Percentage agreements were generally high, especially for Barthel (>75%) and Rivermead (>85%), with considerable variation in kappa coefficients. The authors conclude extended-ADL measurement was less reliable in this study, as published.
Watch out: SHARED report, printed as shared by row direction — one study of 22 patients, never three confirmations; the coordinator will adjudicate the validator flag its presence on three packs raises. Small N (22) prints. The NEADL's random error (±5.6) is the card's finding: week-to-week noise of that size swamps small real changes.
Source: Green et al. A test-retest reliability study of the Barthel Index, the Rivermead Mobility Index, the Nottingham Extended Activities of Daily Living Scale and the Frenchay Activities Index in stroke patients.. Disability and rehabilitation. 2001. PMID: 11720117. Registry ID: none in the record. MeSH: Activities of Daily Living · Aged · Persons with Disabilities/classification,rehabilitation · Female · Humans · Male · Psychomotor Performance · Range of Motion, Articular · Reproducibility of Results · Severity of Illness Index · Stroke/diagnosis · Stroke Rehabilitation
Card 5 — Synthesis: the NEADL is internally consistent and test–retest reliable across four different spectra (α up to 0.97, r/ICC 0.81–0.97) — but it fails Guttman scaling in MS, under-responds after hip replacement, and carries the larger random error (±5.6) of the extended-ADL pair in chronic stroke
Study: Synthesis
Population: Synthesis of the 4 reports carded above (240 MS patients; hip-replacement patients, N not documented in the record; 60 healthy Turkish volunteers; 22 chronic-stroke patients in the shared four-scale study).
Summary: Synthesis: the NEADL is internally consistent and test–retest reliable across four different spectra (α up to 0.97, r/ICC 0.81–0.97) — but it fails Guttman scaling in MS, under-responds after hip replacement, and carries the larger random error (±5.6) of the extended-ADL pair in chronic stroke
Result: Reliability coefficients are consistently high, and the negative limbs are equally consistent: items do not form a Guttman scale in MS (scalability 0.3) or an adequate hierarchical scale after hip replacement; responsiveness after arthroplasty is poor, underestimating health gain; and in the shared stroke study the NEADL's random error (0.6 ± 5.6) exceeded Barthel's and Rivermead's. Populations print — MS, arthroplasty, healthy elderly and chronic stroke are four different spectra, and no coefficient travels between them unlabelled.
Watch out: Composition discipline: 4 reports, one of them shared by row direction (PMID 11720117: NEADL limb here, Frenchay limb on #8167, Rivermead limb on #8179) with its type flag printed. Cross-points in prose only: #8163 (Lawton — instrumental ADL) and #8167 (Frenchay — stroke social/leisure activities). A 2026 short-form derivation (SF-NEADL) is a variant, not counted.
Source: Synthesis of the reports carded above; no additional source.