SourceMed · Shelf #8171 in the ask interface

Community Balance & Mobility Scale: high reliability (ICCs 0.95–1.00) and no ceiling effect in higher-functioning patients — 3 reports on small samples (n = 25–51) + 1 corroboration at N = 16

Shelf #8171 · Geriatrics, frailty & deprescribing

MEASUREMENT PROPERTIES — reliability and construct validity supported on small samples: intra-/inter-rater and test–retest ICCs 0.95–1.00 and α 0.88–0.96 across TBI, young-older and knee-OA samples (n = 25–51 per report), with no ceiling effect in young-older adults where comparator scales ceilinged; composition 3 counted reports + 1 corroboration at N = 16 (not counted); a measurement-properties stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2006–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the Community Balance and Mobility Scale (CB&M — 13 challenging balance/mobility tasks scored to 96, built for higher-functioning ambulatory patients who ceiling on ordinary balance scales) — what validity and reliability did its traumatic brain injury development establish, and what did the young-older-adult and knee osteoarthritis validations find?

Balance of the evidence

Composition prints on the face: 3 counted reports (a programme development study in ambulatory TBI, a young-older-adult validation, a knee osteoarthritis validation) + 1 corroboration (Korean version, N = 16, not counted). A measurement-properties shelf, not a balance-treatment shelf. Derivation and validation samples are small convenience samples (n = 25–51 per counted report) and print with their Ns; the scale was built for ambulatory, higher-functioning patients — no figure generalises to frail or non-ambulatory populations. Cross-points in prose only: BESTest family (#8051) and Berg (#7821) — systems/performance batteries whose ceiling in high-functioning patients is the CB&M's stated reason to exist.

MeSH: Adult · Brain Injuries/physiopathology · Disability Evaluation · Female · Humans · Male · Mobility Limitation · Postural Balance/physiology · Reproducibility of Results · Walking/physiology · Aged · Cross-Sectional Studies · Data Collection · Geriatric Assessment/methods · Middle Aged · Physical Therapy Modalities · Walking Speed/physiology · Exercise Test/methods · Knee Joint/physiopathology · Osteoarthritis, Knee/physiopathology

Cards (5)

Card 1 — Development in traumatic brain injury (Howe 2006, Clinical Rehabilitation — two convenience samples, n = 36 and n = 32, of ambulatory TBI patients; programme report of the Toronto group): content validity from patient/clinician item generation; correlations r = 0.62 with therapists' global balance ratings and r = 0.64 with maximal walking velocity; intra-rater, inter-rater and test–retest ICCs 0.977 / 0.977 / 0.975; α 0.96

Study: Development / validation study (primary report) — ambulatory TBI; programme-labelled (the Toronto group's own report)

Population: Two convenience samples (n = 36, 32) of ambulatory patients with traumatic brain injury in acute care, inpatient/outpatient rehabilitation and day hospital settings; content validity was built from item generation with TBI patients (n = 7) and clinicians (n = 17) plus physical therapists' item-relevance ratings.

Summary: Development in traumatic brain injury (Howe 2006, Clinical Rehabilitation — two convenience samples, n = 36 and n = 32, of ambulatory TBI patients; programme report of the Toronto group): content validity from patient/clinician item generation; correlations r = 0.62 with therapists' global balance ratings and r = 0.64 with maximal walking velocity; intra-rater, inter-rater and test–retest ICCs 0.977 / 0.977 / 0.975; α 0.96

Result: Content validity was demonstrated by the item-generation process and therapists' relevance ratings. Construct support: correlation with physical therapists' global balance ratings r = 0.62 and with maximal walking velocity r = 0.64; the scale differentiated patients along the continuum of care, and patients scoring above vs below 50 differed significantly on Community Integration Questionnaire scores (P = 0.004). Intraclass correlation coefficients were 0.977 (intra-rater), 0.977 (inter-rater) and 0.975 (test–retest), with Cronbach's α 0.96, as published.

Watch out: Derivation samples are small convenience samples (n = 36, 32) and print with their Ns; the scale was built for ambulatory, higher-functioning TBI patients — no figure generalises to frail or non-ambulatory populations.

Source: Howe JA et al. The Community Balance and Mobility Scale--a balance measure for individuals with traumatic brain injury. Clinical Rehabilitation. 2006. PMID: 17008340. Registry ID: none in the record. MeSH: Adult · Brain Injuries/physiopathology · Disability Evaluation · Female · Humans · Male · Mobility Limitation · Postural Balance/physiology · Reproducibility of Results · Walking/physiology

Card 2 — Young-older adults (Weber 2018, BMC Geriatrics — 51 participants aged 60–70): concurrent correlations with the Fullerton Advanced Balance scale ρ = 0.75, tandem-walk errors ρ = −0.61 and Timed Up and Go ρ = −0.42; inter-rater ICC 0.97, intra-rater ICC 1.00, α 0.88; no ceiling effect, in contrast to the comparator scales

Study: Validation study (primary report) — community young-older adults aged 60–70

Population: 51 young-older adults aged 60–70 years (mean 66.4 ± 2.7) assessed with the CB&M alongside the Fullerton Advanced Balance scale, 3-metre tandem walk, an 8-level balance scale, Timed Up and Go and 7-metre habitual gait speed.

Summary: Young-older adults (Weber 2018, BMC Geriatrics — 51 participants aged 60–70): concurrent correlations with the Fullerton Advanced Balance scale ρ = 0.75, tandem-walk errors ρ = −0.61 and Timed Up and Go ρ = −0.42; inter-rater ICC 0.97, intra-rater ICC 1.00, α 0.88; no ceiling effect, in contrast to the comparator scales

Result: The CB&M correlated with the Fullerton Advanced Balance scale (ρ = 0.75, p < .001), tandem-walk errors (ρ = −0.61, p < .001), tandem-walk time (ρ = −0.35), the 8-level balance scale (ρ = 0.35), Timed Up and Go (ρ = −0.42, p < .01) and 7-m gait speed (ρ = 0.46, p < .001). Inter-rater reliability ICC 0.97 and intra-rater ICC 1.00 were excellent; internal consistency α 0.88. The CB&M showed no ceiling effect in this population, in contrast to other scales, as published.

Watch out: A healthy young-older spectrum (60–70 years): the absence of a ceiling effect here is the scale's stated purpose, not evidence about frailer or older populations.

Source: Weber M et al. Concurrent validity and reliability of the Community Balance and Mobility scale in young-older adults. BMC Geriatrics. 2018. PMID: 29970010. Registry ID: ISRCTN37750605. MeSH: Aged · Cross-Sectional Studies · Data Collection · Female · Geriatric Assessment/methods · Humans · Male · Middle Aged · Physical Therapy Modalities · Postural Balance/physiology · Reproducibility of Results · Walking/physiology · Walking Speed/physiology

Card 3 — Knee osteoarthritis (Takacs 2014, Physical Therapy — 25 patients with medial knee OA + 25 healthy controls): CB&M scores correlated significantly with all comparator balance/mobility measures, separated the OA group from controls, and showed test–retest ICC 0.95 (0.70 to 0.99) with SEM 3 points

Study: Validation study (primary report) — medial knee osteoarthritis vs healthy controls

Population: 25 individuals aged 50 years and older with medial knee osteoarthritis and an equal number of healthy controls, completing the CB&M plus the Berg Balance Scale, Timed 'Up & Go', maximal single-leg stance time and the 10-metre walk test at self-selected and fast speeds.

Summary: Knee osteoarthritis (Takacs 2014, Physical Therapy — 25 patients with medial knee OA + 25 healthy controls): CB&M scores correlated significantly with all comparator balance/mobility measures, separated the OA group from controls, and showed test–retest ICC 0.95 (0.70 to 0.99) with SEM 3 points

Result: CB&M scores were significantly correlated with all measures of balance and mobility in the knee OA group (moderate convergent validity, as published — the abstract reports the pattern, not per-test coefficients, and none are printed here beyond it), and differed significantly between the OA and control groups (known-groups validity). Test–retest reliability in knee OA was high: ICC 0.95 (95% CI 0.70 to 0.99), SEM 3 points (95% CI 2.68 to 4.67), as published.

Watch out: Few participants had severe knee OA, as the authors state; the test–retest interval estimate is wide (0.70 to 0.99) on 25 patients and prints with its interval.

Source: Takacs J et al. Validity and reliability of the community balance and mobility scale in individuals with knee osteoarthritis. Physical Therapy. 2014. PMID: 24557649. Registry ID: none in the record. MeSH: Aged · Cross-Sectional Studies · Exercise Test/methods · Female · Humans · Knee Joint/physiopathology · Male · Middle Aged · Osteoarthritis, Knee/physiopathology · Postural Balance/physiology · Reproducibility of Results

Card 4 — Corroboration, not counted (Lee 2016, Journal of Physical Therapy Science — Korean version, N = 16 patients with hemiplegia after stroke; small N prints on the face): inter- and intra-rater reliability high for most subscores, moderate for the 'walking and looking' / 'walk, look, and carry' items; positive correlation with the Berg Balance Scale and negative correlation with Timed Up and Go — the abstract reports no coefficients and none are printed

Study: Translation validation (corroboration report, not counted in the row composition) — Korean version, stroke hemiplegia; N = 16 prints

Population: 16 patients with hemiplegia after stroke at a South Korean hospital, tested with the Korean CB&M, Berg Balance Scale, Timed Up and Go and functional reaching test by a physical therapist in a standardised order across sessions.

Summary: Corroboration, not counted (Lee 2016, Journal of Physical Therapy Science — Korean version, N = 16 patients with hemiplegia after stroke; small N prints on the face): inter- and intra-rater reliability high for most subscores, moderate for the 'walking and looking' / 'walk, look, and carry' items; positive correlation with the Berg Balance Scale and negative correlation with Timed Up and Go — the abstract reports no coefficients and none are printed

Result: Inter- and intra-rater reliability coefficients were high for most subscores; moderate inter-rater reliability was observed for 'walking and looking' and 'walk, look, and carry', and moderate intra-rater reliability for 'forward to backward walking'. Convergent assessments showed a positive correlation between the Korean CB&M and the Berg Balance Scale and a negative correlation with Timed Up and Go, as published; the abstract gives no numeric coefficients, so no coefficient is printed from this report.

Watch out: N = 16 — below the reference floor and never load-bearing; this card is corroboration only, printed so the Korean version is not silently upgraded later. Its record carries no MeSH (source line prints 'MeSH: none in the record').

Source: Lee KB et al. Reliability and validity of the Korean version of the community balance and mobility scale in patients with hemiplegia after stroke. Journal of Physical Therapy Science. 2016. PMID: 27630420. Registry ID: none in the record. MeSH: none in the record

Card 5 — Synthesis: the CB&M's reliability is consistently high across three different spectra (ICCs 0.95–1.00; α 0.88–0.96) and it avoids the ceiling effect that limits ordinary balance scales in higher-functioning patients — on small samples throughout (n = 25–51 per counted report)

Study: Synthesis

Population: Synthesis of the 3 counted reports carded above (TBI development, two convenience samples n = 36/32; 51 young-older adults; 25 knee OA patients + 25 controls), plus the Korean corroboration at N = 16, not counted.

Summary: Synthesis: the CB&M's reliability is consistently high across three different spectra (ICCs 0.95–1.00; α 0.88–0.96) and it avoids the ceiling effect that limits ordinary balance scales in higher-functioning patients — on small samples throughout (n = 25–51 per counted report)

Result: The verified set holds: development in ambulatory TBI (intra-/inter-rater and test–retest ICCs 0.975–0.977, α 0.96; construct correlations r = 0.62–0.64); young-older adults (concurrent ρ = 0.75 against the Fullerton Advanced Balance scale, ICCs 0.97/1.00, α 0.88, no ceiling effect where comparator scales ceilinged); knee OA (test–retest ICC 0.95 (0.70 to 0.99), SEM 3 points on the 96-point scale, known-groups separation). No pooled figure is printed: populations (TBI / healthy young-older / knee OA) print with every figure, and every counted sample is small.

Watch out: Composition discipline: 3 counted reports + 1 corroboration (Korean version, N = 16, not counted). Cross-points in prose only: BESTest family (#8051), Berg (#7821).

Source: Synthesis of the reports carded above; no additional source.