SourceMed · Shelf #8177 in the ask interface

FSS-ICU — Functional Status Score for the ICU: α 0.90–0.95 and r = 0.94 with FIM-motor across four version studies (Ns 30–100) — discharge ceiling effects 10–16%; original development report not carded

Shelf #8177 · Critical care & sepsis

MEASUREMENT PROPERTIES — reliability and validity supported in version studies: α 0.897–0.95, ICCs up to 0.995/0.997 (single-centre pairs), MDC90 1.0 point, convergence with FIM-motor r = 0.94 and with actigraphy inactivity (ρ −0.62/−0.79, beside failed activity hypotheses); discharge ceiling effects 10–16%; composition 4 version/single-centre reports (Ns 30–100), development report not carded; a measurement-properties stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2019–2025.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the FSS-ICU (Functional Status Score for the ICU — five functional tasks (rolling, supine-to-sit, sitting at the edge of bed, sit-to-stand, walking) each rated 0–7 for assistance required, total 0–35) — what reliability and validity did the Chinese and Korean versions establish, what construct validity did the Chilean actigraphy study find, and what measurement properties did the Brazilian head-to-head with the FIM-motor find?

Balance of the evidence

Composition prints on the face: 4 reports, all language-version or single-centre studies (Ns 30–100) — no anchor is the original US development report, which was not returned under the forms tried at mining and is not carded. A measurement-properties shelf. The Chilean actigraphy study's failed hypotheses (activity counts/time not correlating) print beside its inactivity finding. Ceiling effects differ by timing (none in the Chinese study; 10–16% at discharge in the Chilean/Brazilian studies) and print by study. The Chinese card's convergent limb includes a strength measure whose figure is not taken (held #9 fence — no grip figure prints anywhere in this pack). Cross-points in prose only: IMS (#8173), Perme (#8174), CPAx (#8175), PFIT-s (#8176); the FIM-motor limb in the Brazilian card prints as a comparator.

MeSH: Humans · Reproducibility of Results · Intensive Care Units · Female · Male · Middle Aged · Translations · Functional Status · Aged · Adult · China · Translating · Cross-Cultural Comparison · Psychometrics · Surveys and Questionnaires · Republic of Korea · Psychometrics/methods · APACHE · Actigraphy/standards · Chile · Critical Care Outcomes · Disability Evaluation · Intensive Care Units/statistics & numerical data · Length of Stay/statistics & numerical data · Muscle Strength · Patient Discharge/statistics & numerical data · Prospective Studies · Respiration, Artificial/statistics & numerical data · Time Factors · Activities of Daily Living · Aged, 80 and over · Brazil · Critical Illness/therapy · Physical Functional Performance · Severity of Illness Index

Cards (5)

Card 1 — Chinese version (Wu 2025, Disability and Rehabilitation — 51 ICU patients rated by two rehabilitation therapists): α 0.934; inter-rater ICC 0.995 and intra-rater 0.997; item- and scale-level content validity indices 1.00; convergent correlations |rs| >0.5 with the MRC sum-score, the IMS and a strength measure (whose figure is not taken here — held #9 fence), discriminant |rs| <0.2 against BMI and glucose; no floor or ceiling effects

Study: Language validation study (primary report) — Chinese version

Population: 51 ICU patients assessed with the Chinese FSS-ICU after Beaton-model forward translation, back-translation, synthesis, cultural adaptation and preliminary testing; two rehabilitation therapists rated each patient for the reliability and validity analyses.

Summary: Chinese version (Wu 2025, Disability and Rehabilitation — 51 ICU patients rated by two rehabilitation therapists): α 0.934; inter-rater ICC 0.995 and intra-rater 0.997; item- and scale-level content validity indices 1.00; convergent correlations |rs| >0.5 with the MRC sum-score, the IMS and a strength measure (whose figure is not taken here — held #9 fence), discriminant |rs| <0.2 against BMI and glucose; no floor or ceiling effects

Result: The Chinese FSS-ICU showed excellent internal consistency (Cronbach's α 0.934), inter-rater correlation 0.995 and intra-rater correlation 0.997, and item- and scale-level content validity indices of 1.00. Convergent validity was good against other physical-function tools (MRC sum-score, a strength measure and the ICU Mobility Scale), with |rs| values all above 0.5 — the strength measure's own figure is not printed in this pack (held #9 fence) — and discriminant validity was satisfactory against non-physical indicators (BMI, blood glucose), with |rs| all below 0.2. No ceiling or floor effects were demonstrated, as published.

Watch out: Single-centre, two-therapist design: ICCs of 0.995/0.997 from one centre's therapist pair print with their setting; the absence of floor/ceiling effects here contrasts with the discharge ceiling effects in the Chilean and Brazilian cards and prints by study.

Source: Wu TT et al. Reliability and validity of the Chinese version of the functional status score for the ICU (FSS-ICU) after translation and cross-cultural adaptation. Disability and Rehabilitation. 2025. PMID: 38934539. Registry ID: none in the record. MeSH: Humans · Reproducibility of Results · Intensive Care Units · Female · Male · Middle Aged · Translations · Functional Status · Aged · Adult · China · Translating · Cross-Cultural Comparison · Psychometrics · Surveys and Questionnaires

Card 2 — Korean version (Do 2022, Disability and Rehabilitation — 31 medical ICU patients; small N prints on the face): α 0.897; intra- and inter-rater ICCs 0.930–0.993 across the five activities and total; Bland–Altman mean difference 0.2 points (limits of agreement −1.9 to 2.3); moderate-to-strong convergent correlations

Study: Language validation study (primary report) — Korean version; N = 31 prints

Population: 31 patients from a medical ICU, assessed independently by two physiotherapists at each of two university hospitals using the Korean FSS-ICU after expert-committee supervised forward/backward translation; mean total score 23 (range 4–35) on the 0–35 scale.

Summary: Korean version (Do 2022, Disability and Rehabilitation — 31 medical ICU patients; small N prints on the face): α 0.897; intra- and inter-rater ICCs 0.930–0.993 across the five activities and total; Bland–Altman mean difference 0.2 points (limits of agreement −1.9 to 2.3); moderate-to-strong convergent correlations

Result: Internal consistency was excellent (Cronbach's α 0.897 for the total score; 0.844–0.892 with each activity deleted). Intra-rater and inter-rater reliability were excellent for all five activities and the total score (ICC range 0.930–0.993). Bland–Altman analysis showed a mean difference of 0.2 points between physiotherapists (95% limits of agreement −1.9 to 2.3). Construct validity showed moderate-to-strong correlations with mobility and muscle-strength measures and poor correlations with unrelated measures, as published.

Watch out: N = 31 prints on the face; the limits of agreement (−1.9 to 2.3 on a 35-point scale) are the transportable precision figure and print beside the ICC range.

Source: Do JG et al. Reliability and validity of the Korean version of the Functional Status Score for the ICU after translation and cross-cultural adaptation. Disability and Rehabilitation. 2022. PMID: 34713766. Registry ID: none in the record. MeSH: Humans · Cross-Cultural Comparison · Reproducibility of Results · Functional Status · Intensive Care Units · Republic of Korea · Surveys and Questionnaires · Psychometrics/methods

Card 3 — Chilean-Spanish construct validity against actigraphy (Camus-Molina 2020, Archives of Physical Medicine and Rehabilitation — 30 mechanically ventilated patients, of 92 screened; small N prints on the face): inactivity time correlated strongly with FSS-ICU scores (ρ = −0.62 at awakening, ρ = −0.79 at discharge), but activity counts and activity time were NOT correlated as hypothesised — the failed hypotheses print beside the finding; ceiling effect 10% at discharge, none at awakening

Study: Construct-validity study (primary report) — Chilean-Spanish version vs actigraphy; N = 30 prints

Population: 30 mechanically ventilated patients (of 92 screened) in a 12-bed academic medical-surgical ICU, with continuous actigraphy from ICU admission to discharge and FSS-ICU assessed on awakening and at ICU discharge; 12 pre-specified construct hypotheses were tested, including correlations with activity counts, activity time, inactivity time, muscle strength, ICU length of stay and ventilation duration.

Summary: Chilean-Spanish construct validity against actigraphy (Camus-Molina 2020, Archives of Physical Medicine and Rehabilitation — 30 mechanically ventilated patients, of 92 screened; small N prints on the face): inactivity time correlated strongly with FSS-ICU scores (ρ = −0.62 at awakening, ρ = −0.79 at discharge), but activity counts and activity time were NOT correlated as hypothesised — the failed hypotheses print beside the finding; ceiling effect 10% at discharge, none at awakening

Result: Median FSS-ICU was 19 points (IQR 10–26) on awakening and 28.5 (IQR 22–32) at discharge. There was no floor/ceiling effect at awakening (0%/0%) and an acceptable ceiling effect at discharge (0%/10%). The authors report a strong correlation between the FSS-ICU and inactivity time during the ICU stay (ρ = −0.62 at awakening and ρ = −0.79 at discharge, both P < .001 — less inactivity accompanying better scores), while activity counts and activity time were not correlated with the FSS-ICU as hypothesised, as published.

Watch out: Hypothesis discipline prints: of the actigraphy limbs, only inactivity time behaved as hypothesised — activity counts and activity time did not correlate as expected, so this card supports the score's relation to immobility, not to measured activity volume. N = 30 of 92 screened prints.

Source: Camus-Molina A et al. Construct Validity of the Chilean-Spanish Version of the Functional Status Score for the Intensive Care Unit: A Prospective Observational Study Using Actigraphy in Mechanically Ventilated Patients. Archives of Physical Medicine and Rehabilitation. 2020. PMID: 32446906. Registry ID: none in the record. MeSH: APACHE · Actigraphy/standards · Aged · Chile · Critical Care Outcomes · Disability Evaluation · Female · Functional Status · Humans · Intensive Care Units/statistics & numerical data · Length of Stay/statistics & numerical data · Male · Middle Aged · Muscle Strength · Patient Discharge/statistics & numerical data · Prospective Studies · Reproducibility of Results · Respiration, Artificial/statistics & numerical data · Time Factors

Card 4 — Brazilian head-to-head with the FIM-motor (Alves 2019, Revista Brasileira de Terapia Intensiva — 100 ICU patients): FSS-ICU α 0.95, intra-/inter-rater ICC >0.75, MDC90 1.0 point, SEM 2%, correlation with FIM-motor r = 0.94 — but a ceiling effect in 16% of patients (FIM 18%)

Study: Measurement-properties study (primary report) — Brazilian version, head-to-head with FIM-motor (comparator limb)

Population: 100 critically ill ICU patients (mean age 72.1 ± 15.9 years; 53% male) assessed with the Brazilian FSS-ICU and the FIM-motor domain at baseline and after 2 hours by one physiotherapist (test–retest) and 30 minutes after baseline by a second physiotherapist; internal consistency, reliability, agreement, MDC90, ceiling/floor effects and construct validity were compared between the two instruments.

Summary: Brazilian head-to-head with the FIM-motor (Alves 2019, Revista Brasileira de Terapia Intensiva — 100 ICU patients): FSS-ICU α 0.95, intra-/inter-rater ICC >0.75, MDC90 1.0 point, SEM 2%, correlation with FIM-motor r = 0.94 — but a ceiling effect in 16% of patients (FIM 18%)

Result: Both instruments showed adequate internal consistency (FSS-ICU α 0.95; FIM α 0.86) and intra-/inter-rater reliability (ICC > 0.75 for overall scores). Agreement: minimum detectable change at 90% confidence was 1.0 point for both, with standard error of measurement 2% (FSS-ICU) and 1% (FIM). Construct validity between the instruments was strong (r = 0.94, P < 0.001). However, both presented ceiling effects — maximum scores in 16% of patients for the FSS-ICU and 18% for the FIM, as published.

Watch out: The FIM-motor limb prints as a comparator (the FIM's own home is its Rasch/construct shelf). The 16% ceiling effect prints beside the reliability figures: at the top of the ICU function range this five-task score saturates, as does its comparator.

Source: Alves GAA et al. Assessment of the measurement properties of the Brazilian versions of the Functional Status Score for the ICU and the Functional Independence Measure in critically ill patients in the intensive care unit. Revista Brasileira de Terapia Intensiva. 2019. PMID: 31967227. Registry ID: none in the record. MeSH: Activities of Daily Living · Aged · Aged, 80 and over · Brazil · Critical Illness/therapy · Female · Humans · Intensive Care Units · Male · Middle Aged · Physical Functional Performance · Reproducibility of Results · Severity of Illness Index

Card 5 — Synthesis: across four language-version and single-centre studies (Ns 30–100) the FSS-ICU is internally consistent (α 0.90–0.95) and reliably rated (ICCs 0.93–1.00 in the Chinese/Korean studies), tracks inactivity by actigraphy, and correlates r = 0.94 with the FIM-motor — with discharge ceiling effects of 10–16% where they were looked for

Study: Synthesis

Population: Synthesis of the 4 reports carded above (Chinese n = 51; Korean n = 31; Chilean actigraphy n = 30; Brazilian n = 100). No anchor is the original US development report, which was not returned under the forms tried at mining and is not carded — printed on the face.

Summary: Synthesis: across four language-version and single-centre studies (Ns 30–100) the FSS-ICU is internally consistent (α 0.90–0.95) and reliably rated (ICCs 0.93–1.00 in the Chinese/Korean studies), tracks inactivity by actigraphy, and correlates r = 0.94 with the FIM-motor — with discharge ceiling effects of 10–16% where they were looked for

Result: The verified set holds: internal consistency α 0.934 (Chinese), 0.897 (Korean) and 0.95 (Brazilian); inter-/intra-rater ICCs 0.995/0.997 (Chinese, one centre's therapist pair) and 0.930–0.993 (Korean), with Korean limits of agreement −1.9 to 2.3 points and a Brazilian MDC90 of 1.0 point; construct support from actigraphy inactivity time (ρ = −0.62/−0.79) beside failed activity-count/time hypotheses; and convergence with the FIM-motor at r = 0.94. Ceiling effects differ by timing and study — none in the Chinese study, 10% at discharge in Chile, 16% in Brazil — and print by study, never merged. No pooled figure is printed.

Watch out: Composition discipline: 4 language-version/single-centre reports, Ns 30–100; original development report not carded (not returned). Cross-points in prose only: IMS (#8173), Perme (#8174), CPAx (#8175), PFIT-s (#8176), and the FIM shelf (Brazilian comparator limb).

Source: Synthesis of the reports carded above; no additional source.