SourceMed · Shelf #8181 in the ask interface
RCSQ — Richards–Campbell Sleep Questionnaire: internally consistent across three language versions (α 0.88–0.92), but nurses overestimate patients' sleep (agreement ICCs 0.13–0.49) — no polysomnography validation in this set
Shelf #8181 · Critical care & sepsis
MEASUREMENT PROPERTIES — self-report consistency supported; proxy substitution and objective measurement NOT ESTABLISHED: α 0.88–0.92 across Chinese/Arabic/German versions with single-factor structure confirmed in Chinese, but patient–nurse agreement ICCs only 0.13–0.49 with systematic nurse overestimation (a nurse-completed RCSQ is not a substitute for the patient's own rating), and no polysomnography validation exists in this set; composition 1 agreement study + 3 language validations; a measurement-properties stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2012–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the RCSQ (Richards–Campbell Sleep Questionnaire — five visual-analogue items on depth, latency, awakenings, return to sleep and overall quality, for critically ill patients) — how well do nurses' proxy ratings agree with patients' own ratings, and what internal consistency and structure did the Chinese, Arabic and German ICU versions establish?
Balance of the evidence
Composition prints on the face: 1 patient–nurse agreement study + 3 language validations (Chinese, Arabic, German). NO POLYSOMNOGRAPHY ANCHOR: no anchor in this set validates the RCSQ against polysomnography — a PSG narrative in any earlier draft of this row is withdrawn in full and does not reappear anywhere in this pack; no card may present the RCSQ as an objective sleep measurement or quote a PSG correlation from this row. A measurement-properties shelf. The language validations establish internal consistency (α 0.88–0.92) and structure, not accuracy against physiology. Samples are small (33–150) and print with their Ns. Distinct from pack #7967 (PSQI/ISI/Athens accuracy — clinic instruments in non-ICU patients) and pack #8077 (Epworth — daytime sleepiness, a different construct): the RCSQ is the ICU-bedside sleep self-report; cross-points in prose only.
MeSH: Female · Humans · Intensive Care Units · Male · Middle Aged · Noise · Nursing Assessment · Polysomnography · Reproducibility of Results · Self-Assessment · Sleep/physiology · Sleep Initiation and Maintenance Disorders/diagnosis,prevention & control · Surveys and Questionnaires · China · Critical Illness/nursing · Patient Reported Outcome Measures · Psychometrics · Translating · Critical Illness · Feasibility Studies · Inpatients · Saudi Arabia · Sleep · Translations · Critical Illness/therapy · Cross-Sectional Studies · Germany · Hospitals, University · Incidence · Noise/adverse effects · Prospective Studies · Quality Control · Risk Assessment · Sleep Wake Disorders/classification,epidemiology
Cards (5)
Card 1 — Patient–nurse agreement study (Kamdar 2012, American Journal of Critical Care — 33 medical-ICU patients, 92 paired blinded assessments): nurses rated sleep systematically BETTER than patients did (total score 68 ± 19 vs 57 ± 28, P = .01; sleep depth 67 vs 48, P = .001), and patient–nurse ICCs ranged only 0.13 to 0.49 across items ('slight' to 'moderate') — the row's honesty anchor: a nurse-completed RCSQ is not a substitute for the patient's own rating
Study: Agreement / inter-rater reliability study (primary report) — patient vs nurse proxy ratings; the row's anchor report
Population: 33 conscious, non-delirious medical-ICU patients with 92 paired assessments over 24 days: night-shift nurses completed the RCSQ (5 items plus a noise rating, each on a 100-mm visual analogue scale) for their patients' overnight sleep, and patients completed it themselves on awakening, each blinded to the other's ratings; agreement used mean differences and Bland–Altman plots, reliability intraclass correlation coefficients.
Summary: Patient–nurse agreement study (Kamdar 2012, American Journal of Critical Care — 33 medical-ICU patients, 92 paired blinded assessments): nurses rated sleep systematically BETTER than patients did (total score 68 ± 19 vs 57 ± 28, P = .01; sleep depth 67 vs 48, P = .001), and patient–nurse ICCs ranged only 0.13 to 0.49 across items ('slight' to 'moderate') — the row's honesty anchor: a nurse-completed RCSQ is not a substitute for the patient's own rating
Result: For all RCSQ items, nurses' scores were higher (indicating 'better' sleep) than patients' scores, significantly so for sleep depth (mean [SD] 67 [21] vs 48 [35], P = .001), awakenings (68 [21] vs 60 [33], P = .03) and total score (68 [19] vs 57 [28], P = .01); Bland–Altman plots likewise showed nurses' ratings generally higher. Intraclass correlation coefficients of patient–nurse pairs ranged from 0.13 to 0.49 across the survey questions — 'slight' to 'moderate' reliability, with nurses tending to overestimate patients' perceived sleep quality, as published.
Watch out: Proxy discipline prints: this is the only agreement report in the set, and it fails the substitution question — ICCs of 0.13–0.49 with a systematic upward bias mean nurse-completed scores overstate patients' sleep; no card on this shelf may present a nurse rating as the patient's sleep measurement.
Source: Kamdar BB et al. Patient-nurse interrater reliability and agreement of the Richards-Campbell sleep questionnaire. American Journal of Critical Care. 2012. PMID: 22751369. Registry ID: none in the record. MeSH: Female · Humans · Intensive Care Units · Male · Middle Aged · Noise · Nursing Assessment · Polysomnography · Reproducibility of Results · Self-Assessment · Sleep/physiology · Sleep Initiation and Maintenance Disorders/diagnosis,prevention & control · Surveys and Questionnaires
Card 2 — Chinese version (Chen 2019, Nursing in Critical Care — 150 critically ill patients; 44 in the convergent limb against the St Mary's Hospital Sleep Questionnaire): α 0.923; item–total correlations 0.680–0.805; content validity 0.84; the original single-factor structure fitted on confirmatory analysis; discrimination between good and poor sleepers; patient–nurse ICCs 0.315–0.609 ('fair' to 'substantial'), nurses again overestimating
Study: Language validation study (primary report) — Chinese version (RCSQ-C)
Population: 150 critically ill ICU patients for internal consistency, discrimination and construct validity of the forward/back-translated Chinese RCSQ (RCSQ-C); 44 of the 150 formed the convergent limb against the Chinese St Mary's Hospital Sleep Questionnaire, and patient scores were compared with their nurses' scores for inter-rater reliability and agreement.
Summary: Chinese version (Chen 2019, Nursing in Critical Care — 150 critically ill patients; 44 in the convergent limb against the St Mary's Hospital Sleep Questionnaire): α 0.923; item–total correlations 0.680–0.805; content validity 0.84; the original single-factor structure fitted on confirmatory analysis; discrimination between good and poor sleepers; patient–nurse ICCs 0.315–0.609 ('fair' to 'substantial'), nurses again overestimating
Result: Cronbach's α was 0.923 and corrected item–total correlations ranged 0.680–0.805, showing the items homogeneous. Content validity was 0.84. One factor was extracted (cumulative contribution 76.597%) and confirmatory factor analysis showed the original single-factor structure fitted adequately. The RCSQ-C discriminated poor from good sleepers and correlated closely with the St Mary's questionnaire. Patient–nurse intraclass correlation coefficients ranged 0.315 to 0.609 ('fair' to 'substantial'), with nurses again tending to overestimate patients' perceived sleep quality, as published.
Watch out: The Chinese patient–nurse ICCs (0.315–0.609) are higher than the anchor study's (0.13–0.49) but the direction of bias is the same (nurses overestimate) and both ranges print by study — internal consistency (α 0.923) is a within-rater property and does not repair proxy disagreement.
Source: Chen LX et al. Richards-Campbell sleep questionnaire: psychometric properties of Chinese critically ill patients. Nursing in Critical Care. 2019. PMID: 30062842. Registry ID: none in the record. MeSH: China · Critical Illness/nursing · Female · Humans · Intensive Care Units · Male · Middle Aged · Nursing Assessment · Patient Reported Outcome Measures · Psychometrics · Reproducibility of Results · Sleep/physiology · Surveys and Questionnaires · Translating
Card 3 — Arabic version (Al-Sulami 2019, Journal of Nursing Measurement — 57 critically ill participants completing 110 repeated assessments in Saudi Arabia): α 0.89; content validity supported by WHO-process translation and cognitive debriefing interviews; feasibility demonstrated
Study: Language validation study (primary report) — Arabic version (RCSQ-A), repeated assessments
Population: 57 critically ill participants in Saudi Arabia completing the Arabic RCSQ (RCSQ-A) a total of 110 times in a prospective repeated-assessments design, after rigorous WHO-process translation and cognitive debriefing interviews for content validity; internal consistency and feasibility were evaluated.
Summary: Arabic version (Al-Sulami 2019, Journal of Nursing Measurement — 57 critically ill participants completing 110 repeated assessments in Saudi Arabia): α 0.89; content validity supported by WHO-process translation and cognitive debriefing interviews; feasibility demonstrated
Result: Cronbach's α of the RCSQ-A was 0.89. Cognitive interviews showed the Arabic version was well understood and interpreted correctly and consistently. With 57 participants reporting their sleep 110 times in total, the RCSQ-A showed adequate translation validity, good internal consistency and content validity, and feasibility for use in Arabic-speaking critical care, as published — the abstract reports no agreement or criterion figures, and none are printed from this report.
Watch out: A translation/feasibility report: it establishes that Arabic-speaking patients can complete the instrument consistently, not that scores agree with nurses, other instruments or physiology in this population.
Source: Al-Sulami GS et al. An Arabic Translation, Reliability, Validity, and Feasibility of the Richards-Campbell Sleep Questionnaire for Sleep Quality Assessment in ICU: Prospective-Repeated Assessments. Journal of Nursing Measurement. 2019. PMID: 31871294. Registry ID: none in the record. MeSH: Critical Illness · Feasibility Studies · Female · Humans · Inpatients · Intensive Care Units · Male · Middle Aged · Reproducibility of Results · Saudi Arabia · Sleep · Surveys and Questionnaires · Translations
Card 4 — German version (Krotsetis 2017, Nursing in Critical Care — 51 patients across 3 ICUs): α 0.88; mean total score 47.0 ± 27.6, with sleep depth rated lowest and falling asleep again highest among the items
Study: Language validation study (primary report) — German version, 3 ICUs
Population: 51 critically ill patients at 3 intensive care units of a German university hospital, assessed cross-sectionally with the German RCSQ after translation following established methodological standards; internal consistency and the sample's sleep perception were evaluated.
Summary: German version (Krotsetis 2017, Nursing in Critical Care — 51 patients across 3 ICUs): α 0.88; mean total score 47.0 ± 27.6, with sleep depth rated lowest and falling asleep again highest among the items
Result: The German RCSQ showed an overall internal consistency of Cronbach's α 0.88. The mean total score in the sample was 47.00 (SD ± 27.57) on the 0–100 scale — generally low perceived sleep quality — with depth of sleep rated the lowest item and falling asleep again the highest, as published. The abstract reports no reliability-beyond-α or criterion figures, and none are printed from this report.
Watch out: A single internal-consistency figure (α 0.88) and a descriptive mean: the German card supports the instrument's translatability and the sample's poor perceived sleep, nothing more — no validity claim may be built on it.
Source: Krotsetis S et al. The reliability of the German version of the Richards Campbell Sleep Questionnaire. Nursing in Critical Care. 2017. PMID: 28168810. Registry ID: none in the record. MeSH: Critical Illness/therapy · Cross-Sectional Studies · Female · Germany · Hospitals, University · Humans · Incidence · Intensive Care Units · Male · Noise/adverse effects · Prospective Studies · Quality Control · Reproducibility of Results · Risk Assessment · Sleep/physiology · Sleep Wake Disorders/classification,epidemiology · Surveys and Questionnaires
Card 5 — Synthesis: the RCSQ is internally consistent across three language versions (α 0.88–0.92) with its single-factor structure confirmed in Chinese — but its one patient–nurse agreement study shows nurses systematically overestimate patients' sleep with ICCs of only 0.13–0.49, and NO report in this set validates the RCSQ against polysomnography: it is a patient self-report instrument, not an objective sleep measurement
Study: Synthesis
Population: Synthesis of the 4 reports carded above. Composition, printed on the face: 1 patient–nurse agreement study (33 patients, 92 paired assessments) + 3 language validations (Chinese n = 150; Arabic 57 participants/110 assessments; German n = 51). No polysomnography anchor exists in this set.
Summary: Synthesis: the RCSQ is internally consistent across three language versions (α 0.88–0.92) with its single-factor structure confirmed in Chinese — but its one patient–nurse agreement study shows nurses systematically overestimate patients' sleep with ICCs of only 0.13–0.49, and NO report in this set validates the RCSQ against polysomnography: it is a patient self-report instrument, not an objective sleep measurement
Result: The verified set holds: patient–nurse agreement is 'slight' to 'moderate' (ICCs 0.13–0.49) with a systematic nurse overestimate (total 68 vs 57; depth 67 vs 48) in the anchor study, and a wider but still imperfect range (0.315–0.609) with the same overestimation direction in the Chinese study; internal consistency is high in every language version (α 0.923 Chinese, 0.89 Arabic, 0.88 German), with item–total correlations 0.680–0.805, content validity 0.84 and a confirmed single-factor structure in Chinese, and discrimination between good and poor sleepers. The language validations establish internal consistency and structure, not accuracy against physiology: no anchor in this set validates the RCSQ against polysomnography, and no PSG correlation is quoted anywhere in this pack. Samples are small (33–150) and print with their Ns.
Watch out: Composition discipline: 1 agreement study + 3 language validations; NO PSG anchor (any earlier PSG narrative for this row is withdrawn in full). Cross-points in prose only: pack #7967 (PSQI/ISI/Athens accuracy — clinic instruments in non-ICU patients) and pack #8077 (Epworth — daytime sleepiness, a different construct).
Source: Synthesis of the reports carded above; no additional source.