SourceMed · Shelf #8188 in the ask interface

ICIQ-OAB — International Consultation on Incontinence Questionnaire, Overactive Bladder module: α 0.70–0.76 across the Brazilian Portuguese, Persian and Turkish validations; test–retest ICC 0.91 (Brazilian) against a Kendall correlation of 0.66 (Persian, printed in its own terms) — 3 language validations, no derivation anchor carded

Shelf #8188 · Urology & men’s health

MEASUREMENT PROPERTIES — adequate-not-strong internal consistency across all three versions: α 0.70 (Brazilian Portuguese, n = 142 mixed-sex irritative-symptom patients), 0.76 (Persian) and 0.73 (Turkish, 92 women); test–retest ICC 0.91 at 4 weeks (Brazilian) and item ICC / κ >0.7 at 15 days (Turkish); the Persian stability figure is a Kendall correlation of 0.66 in 50 participants, not an ICC, and prints in its own terms; criterion correlation with the ICIQ-SF r = 0.7 (Brazilian); the Turkish version showed good ROC discriminant validity and significant improvement after 3 months of treatment in 39 treated women (sensitivity to change); bother items are part of the module's scoring and the module must not be reduced to its four symptom items; a measurement stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2010–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the ICIQ-OAB (the International Consultation on Incontinence Questionnaire — Overactive Bladder module: frequency, nocturia, urgency and urge incontinence items with bother ratings) — what reliability and validity did the Brazilian Portuguese, Persian and Turkish validations establish?

Balance of the evidence

Composition prints on the face: 3 language validations and no English-language derivation anchor — the module's derivation report was not returned under the forms tried at mining and is not carded. All three anchors' figures were re-verified against the fetched records and match the slate text. A measurement-properties shelf, not an overactive-bladder treatment shelf. The ICIQ-FLUTS form is NOT rowed here — it is the module/successor form of the homed BFLUTS pack #8156. Cross-points in prose only: pack #8155 (OABSS — a 4-item symptom score), pack #8087 (OAB-q — symptom + HRQoL questionnaire), pack #8156 (BFLUTS), pack #8189 (ICIQ-MLUTS), pack #8190 (DAN-PSS).

MeSH: Adult · Aged · Aged, 80 and over · Brazil · Female · Humans · Language · Male · Middle Aged · Surveys and Questionnaires · Urinary Bladder, Overactive/diagnosis · Urinary Incontinence/diagnosis · Adolescent · Iran · Quality of Life · Reproducibility of Results · Severity of Illness Index · Translations · Urinary Bladder, Overactive/complications,diagnosis · Urinary Incontinence/complications,diagnosis · Young Adult

Cards (4)

Card 1 — Brazilian Portuguese validation (Pereira 2010, Revista Brasileira de Ginecologia e Obstetrícia — 142 male and female patients with irritative urinary symptoms, retest at 4 weeks): α 0.7, test–retest ICC 0.91, and criterion correlation with the ICIQ-SF of Pearson r = 0.7 (p = .0001)

Study: Validation study (primary report) — Brazilian Portuguese version

Population: 142 male and female patients with irritative urinary symptoms completed the final Brazilian Portuguese ICIQ-OAB together with the previously validated ICIQ-SF; the retest was performed four weeks after the first interview, and reliability (internal consistency and test–retest) and validity were evaluated.

Summary: Brazilian Portuguese validation (Pereira 2010, Revista Brasileira de Ginecologia e Obstetrícia — 142 male and female patients with irritative urinary symptoms, retest at 4 weeks): α 0.7, test–retest ICC 0.91, and criterion correlation with the ICIQ-SF of Pearson r = 0.7 (p = .0001)

Result: Internal consistency was Cronbach α 0.7. Test–retest stability was ICC 0.91 for the ICIQ-OAB (0.95 in the record's comparison against the ICIQ-SF), and the Pearson correlation between the instruments was 0.7 (p = 0.0001), confirming criterion validity; concurrent validity was also evaluated against clinical and sociodemographic variables, as published.

Watch out: The criterion here is another questionnaire (the ICIQ-SF short form), not urodynamics or a bladder diary — criterion validity in this family is questionnaire-against-questionnaire throughout. α 0.70 sits at the conventional adequacy threshold and prints unrounded; the mixed-sex irritative-symptom spectrum is broader than diagnosed overactive bladder and prints as such.

Source: Pereira et al. [Validation of the International Consultation on Incontinence Questionnaire Overactive Bladder (ICIQ-OAB) for Portuguese]. Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia. 2010. PMID: 20945012. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Brazil · Female · Humans · Language · Male · Middle Aged · Surveys and Questionnaires · Urinary Bladder, Overactive/diagnosis · Urinary Incontinence/diagnosis

Card 2 — Persian validation (Sari Motlagh 2015, Lower Urinary Tract Symptoms): modified content validity index >0.78 for all items, α 0.76, and test–retest Kendall correlation 0.66 in 50 participants — the stability figure is a Kendall correlation, not an ICC, and prints in its own terms

Study: Validation study (primary report) — Persian version

Population: Persian-speaking patients with overactive bladder symptoms; the British English original was forward- and back-translated and finalised by a research team, content validity was assessed by the modified content validity index, and test–retest was performed in 50 participants (the record does not state the total validation sample size).

Summary: Persian validation (Sari Motlagh 2015, Lower Urinary Tract Symptoms): modified content validity index >0.78 for all items, α 0.76, and test–retest Kendall correlation 0.66 in 50 participants — the stability figure is a Kendall correlation, not an ICC, and prints in its own terms

Result: The modified content validity index was >0.78 for all questions. Cronbach α was 0.76 for all participants, and the Kendall correlation coefficient for test–retest assessment was 0.66, which the authors interpret as indicating the reliability of the questionnaire, as published.

Watch out: A Kendall τ of 0.66 is not interchangeable with an ICC of 0.66 and must never be relabelled as one at build or in summary; it is also the family's weakest stability figure and prints beside the Brazilian ICC of 0.91 rather than being averaged with it. The total sample size is not stated in the abstract record — only the 50-person retest limb is sized, and no larger N may be quoted.

Source: Sari Motlagh et al. Reliability and Validation of the International Consultation on Incontinence Questionnaire in Over Active Bladder to Persian Language. Lower urinary tract symptoms. 2015. PMID: 26663689. Registry ID: none in the record. MeSH: Adolescent · Adult · Female · Humans · Iran · Male · Middle Aged · Quality of Life · Reproducibility of Results · Severity of Illness Index · Surveys and Questionnaires · Translations · Urinary Bladder, Overactive/complications,diagnosis · Urinary Incontinence/complications,diagnosis · Young Adult

Card 3 — Turkish validation (Tas 2026, International Urogynecology Journal — 92 women: 47 with overactive bladder, 45 controls, all re-tested at 15 days): α 0.73, item ICCs / κ >0.7, missing data <1%, good discriminant validity by ROC analysis, and significant improvement after 3 months of treatment in the 39 treated symptomatic women (sensitivity to change) — the record carries no MeSH terms

Study: Validation study (primary report) — Turkish version in women

Population: 92 women applying to a urogynecology outpatient clinic (47 with overactive bladder syndrome, 45 controls) completed the Turkish ICIQ-OAB and repeated it 15 days later after pilot testing in 10 women; 39 symptomatic women were treated and re-analysed after 3 months for sensitivity to change, with bladder-diary correlation.

Summary: Turkish validation (Tas 2026, International Urogynecology Journal — 92 women: 47 with overactive bladder, 45 controls, all re-tested at 15 days): α 0.73, item ICCs / κ >0.7, missing data <1%, good discriminant validity by ROC analysis, and significant improvement after 3 months of treatment in the 39 treated symptomatic women (sensitivity to change) — the record carries no MeSH terms

Result: More than 90% of women found the questions clear, unequivocal and comprehensive, and missing data were <1%. Cronbach α was 0.73. Intraclass correlation coefficients and kappa values for individual items were >0.7. ROC comparison of symptomatic and asymptomatic women showed good discriminant validity, and post-treatment results correlated significantly with bladder-diary change, indicating good sensitivity to change, as published.

Watch out: Women only, from a single urogynecology clinic — the Turkish figures do not extend the module to men (the Brazilian anchor is the mixed-sex limb). The ROC analysis is reported qualitatively ('good discriminant validity') with no AUC in the abstract record, and no AUC may be printed from this anchor. The source line prints 'MeSH: none in the record'.

Source: Tas et al. Validation of the Turkish version of the International Consultation on Incontinence Questionnaire-Overactive Bladder. International urogynecology journal. 2026. PMID: 42955292. Registry ID: none in the record. MeSH: none in the record

Card 4 — Synthesis: across three language validations the ICIQ-OAB is internally consistent at an adequate-not-strong level (α 0.70–0.76), stable over 2–4 weeks by its ICC limbs (0.91 Brazilian; item >0.7 Turkish) with a weaker Kendall stability figure (0.66) in the Persian study, criterion-valid against the ICIQ-SF (r = 0.7), and responsive to treatment in the one study that tested change

Study: Synthesis

Population: Synthesis of the 3 reports carded above (142 mixed-sex Brazilian patients; Persian sample sized only for its 50-person retest limb in the record; 92 Turkish women).

Summary: Synthesis: across three language validations the ICIQ-OAB is internally consistent at an adequate-not-strong level (α 0.70–0.76), stable over 2–4 weeks by its ICC limbs (0.91 Brazilian; item >0.7 Turkish) with a weaker Kendall stability figure (0.66) in the Persian study, criterion-valid against the ICIQ-SF (r = 0.7), and responsive to treatment in the one study that tested change

Result: The verified set holds: three independent translation validations converging on α 0.70–0.76 — a consistent, modest internal-consistency spine that prints as the row's headline rather than being rounded up; stability estimates that differ in kind (ICC vs Kendall) and print in their own terms; one criterion correlation against a sister questionnaire; and one responsiveness limb. No derivation anchor is carded, no anchor references urodynamics, and no minimal important difference is established anywhere in the set.

Watch out: Composition discipline: 3 language validations, 0 derivation anchors — printed on every face. Cross-points in prose only: #8155 (OABSS), #8087 (OAB-q), #8156 (BFLUTS), #8189 (ICIQ-MLUTS), #8190 (DAN-PSS).

Source: Synthesis of the reports carded above; no additional source.