SourceMed · Shelf #8191 in the ask interface

FISI — Fecal Incontinence Severity Index (severity weighted by leakage type × frequency, patient and surgeon weighting matrices): Italian prospective validation α 0.810 / 0.806, Spearman 0.915, inter-rater 0.871 (n = 100 — shared report, also carded on pack #8192); Turkish α 0.735 (patient) / 0.734 (surgeon) with manometry criterion validity (58 women); Dutch authors' own verdict for the FISI 'inconclusive' — 3 language-version reports, no derivation anchor carded

Shelf #8191 · Liver & gut

MEASUREMENT PROPERTIES — mixed, with one anchor's own verdict inconclusive: Italian prospective validation α 0.810 / 0.806 across administrations, Spearman correlation 0.915 and inter-rater reliability 0.871 in 100 patients (shared report — PMID 37368229 is also carded on pack #8192 for its St Mark's limb, stated on both faces); Turkish version α 0.735 (patient-rated) / 0.734 (surgeon-rated) in 58 women with significant 2-week test–retest correlation and criterion validity against maximal squeeze and resting pressures; Dutch evaluation found clear discriminative separation (FISI 38.57 ± 10.73 in 55 patients vs 23.17 ± 15.01 in 277 reference participants) and good reproducibility, but its authors concluded validity and reliability were good for the FIQL and 'inconclusive' for the FISI — that verdict prints on the face; FISI weights are population-derived and the patient vs surgeon matrices differ, so cross-population score comparisons are exactly what this instrument makes hazardous; a measurement stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2016–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the FISI (Fecal Incontinence Severity Index — severity weighted by leakage type × frequency, with patient and surgeon weighting matrices) — what did the Italian prospective validation establish, what reliability and criterion validity did the Turkish version find, and what did the Dutch evaluation conclude about its measurement properties?

Balance of the evidence

Composition prints on the face: 3 language-version reports and no derivation anchor — the original weighting-matrix derivation was not returned under the forms tried at mining and is not carded. ROW-DIRECTED SHARING: PMID 37368229 (n = 100) is carded on BOTH this pack (its FISI limb) and pack #8192 (its St Mark's / Vaizey limb) — the same patients also completed the Wexner score, whose limb belongs to reserve row S32-4-31; the sharing is stated here, on the card and on pack #8192's face. The Dutch report is shared with its FIQL limb, printed as shared on its card. All figures were re-verified against the fetched records and match the slate text. A measurement-properties shelf, not a continence-treatment shelf. The FISI's defining feature is its weighting matrices (patient vs surgeon weights differ). Cross-points in prose only: pack #8192 (St Mark's / Vaizey — clinician-scored severity), pack #8188 (ICIQ-OAB), pack #8156 (BFLUTS — the homed female-LUTS pack), pack #8087 (OAB-q).

MeSH: Humans · Quality of Life · Reproducibility of Results · Prospective Studies · Fecal Incontinence/diagnosis · Severity of Illness Index · Language · Surveys and Questionnaires · Italy · Aged · Case-Control Studies · Fecal Incontinence/physiopathology · Female · Middle Aged · Statistics, Nonparametric · Translating · Translations · Turkey · Adaptation, Psychological · Adult · Emotions · Fecal Incontinence/diagnosis,psychology · Life Style · Male · Patient Reported Outcome Measures · Quality of Life/psychology

Cards (4)

Card 1 — Italian prospective validation (Ortenzi 2023, Updates in Surgery — 100 Italian-speaking patients, each questionnaire administered twice by two independent raters): FISI α 0.810 / 0.806 across administrations, Spearman correlation 0.915 and inter-rater reliability 0.871 — SHARED REPORT, printed as shared: the same study validated the Vaizey (St Mark's) and Wexner scores in the same patients; its St Mark's limb is carded on pack #8192 and its Wexner limb belongs to reserve row S32-4-31

Study: Prospective validation study (primary report) — Italian version; SHARED REPORT (also carded on #8192)

Population: 100 Italian-speaking patients completed the forward–backward translated Italian FISI (and the Vaizey and Wexner questionnaire) twice, administered independently by two different raters; reliability and validity of the Italian versions were assessed.

Summary: Italian prospective validation (Ortenzi 2023, Updates in Surgery — 100 Italian-speaking patients, each questionnaire administered twice by two independent raters): FISI α 0.810 / 0.806 across administrations, Spearman correlation 0.915 and inter-rater reliability 0.871 — SHARED REPORT, printed as shared: the same study validated the Vaizey (St Mark's) and Wexner scores in the same patients; its St Mark's limb is carded on pack #8192 and its Wexner limb belongs to reserve row S32-4-31

Result: Cronbach α for the first and second FISI administrations was 0.810 and 0.806 respectively. Spearman correlation was 0.915 and inter-rater reliability 0.871 for the FISI questionnaire. The authors conclude the Italian versions showed good consistency, reliability and reproducibility, with good psychometric properties, as published.

Watch out: Row-directed sharing: this PMID is carded here for its FISI limb and on pack #8192 for its St Mark's limb — one study, two shelves, stated on both faces per the coordinator's adjudication; it must not be counted as two independent reports in any cross-pack tally. The α pair (0.810 / 0.806) is by administration occasion, not by weighting matrix; this study does not compare the patient and surgeon matrices.

Source: Ortenzi et al. Prospective Italian validation of the Vaizey and Wexner and fecal incontinence severity index (FISI) questionnaires. Updates in surgery. 2023. PMID: 37368229. Registry ID: none in the record. MeSH: Humans · Quality of Life · Reproducibility of Results · Prospective Studies · Fecal Incontinence/diagnosis · Severity of Illness Index · Language · Surveys and Questionnaires · Italy

Card 2 — Turkish version (Kucukbas 2016, Female Pelvic Medicine & Reconstructive Surgery — 58 women: 22 scoring 0 / continent, 36 with some incontinence): α 0.735 (patient-rated) / 0.734 (surgeon-rated), significant 2-week test–retest correlation (p < 0.001), and criterion validity against manometry — total and subgroup scores correlating with maximal squeeze and resting pressures, which themselves separated the continent and incontinent groups

Study: Validation study (primary report) — Turkish version in women

Population: 58 women in a prospective cohort: 22 (37.9%) scored 0 (no incontinence) and 36 (62.1%) scored at least 1 (any gas, mucus, liquid or solid incontinence, pad wear or lifestyle alteration); test–retest at 2 weeks, internal consistency, content-face validity and criterion validity against anorectal manometry were evaluated for patient- and surgeon-rated scores.

Summary: Turkish version (Kucukbas 2016, Female Pelvic Medicine & Reconstructive Surgery — 58 women: 22 scoring 0 / continent, 36 with some incontinence): α 0.735 (patient-rated) / 0.734 (surgeon-rated), significant 2-week test–retest correlation (p < 0.001), and criterion validity against manometry — total and subgroup scores correlating with maximal squeeze and resting pressures, which themselves separated the continent and incontinent groups

Result: The 2-week test–retest showed significant correlation (p < 0.001). Cronbach α was 0.735 for patient-rated and 0.734 for surgeon-rated total scores. Total and all subgroup FISI scores correlated significantly with maximal squeeze pressure and resting pressure values, and both pressures differed significantly between women with no incontinence and women with any incontinence, as published. The authors conclude the Turkish FISI is reliable, consistent and valid for Turkish-speaking women.

Watch out: Women only, and over a third of the sample scored 0 (continent) — the α and correlation figures describe a mixed continent/incontinent spectrum, not a clinic incontinence caseload. The record reports the test–retest result as a significant correlation without a coefficient; no test–retest coefficient may be printed from this anchor. The near-identical patient/surgeon α pair (0.735 / 0.734) prints as a reminder that the two weighting matrices are separate instruments in effect.

Source: Kucukbas et al. Validation of the Fecal Incontinence Severity Index in a Turkish Population. Female pelvic medicine & reconstructive surgery. 2016. PMID: 26945267. Registry ID: none in the record. MeSH: Aged · Case-Control Studies · Fecal Incontinence/physiopathology · Female · Humans · Middle Aged · Prospective Studies · Reproducibility of Results · Severity of Illness Index · Statistics, Nonparametric · Surveys and Questionnaires · Translating · Translations · Turkey

Card 3 — Dutch evaluation ('t Hoen 2017, Neurourology and Urodynamics — Dutch FISI and FIQL: 55 patients + 277 reference participants): clear discriminative separation (FISI 38.57 ± 10.73 in patients vs 23.17 ± 15.01 in references, p < 0.001), reproducibility reported as good — and the authors' own conclusion that validity and reliability were good for the FIQL but 'inconclusive' for the FISI; the authors' inconclusive verdict prints on the face — shared report (FIQL limb), printed as shared

Study: Validation study (primary report) — Dutch versions of FISI and FIQL; authors' FISI verdict: inconclusive

Population: Women and men experiencing fecal incontinence (55 patients) and a reference group (277 participants) completed the Dutch FIQL quality-of-life scale and FISI; discriminative ability, internal consistency, reproducibility, construct validity and responsiveness were tested by standardised measurement properties.

Summary: Dutch evaluation ('t Hoen 2017, Neurourology and Urodynamics — Dutch FISI and FIQL: 55 patients + 277 reference participants): clear discriminative separation (FISI 38.57 ± 10.73 in patients vs 23.17 ± 15.01 in references, p < 0.001), reproducibility reported as good — and the authors' own conclusion that validity and reliability were good for the FIQL but 'inconclusive' for the FISI; the authors' inconclusive verdict prints on the face — shared report (FIQL limb), printed as shared

Result: Patients had significantly higher FISI scores than references (38.57 ± 10.73 vs 23.17 ± 15.01; p < 0.001), indicating discriminative ability. The FIQL demonstrated adequate internal consistency on all domains (0.72–0.96) except embarrassment (0.55). Reproducibility was good for both measures. A negative correlation was found between the FIQL and FISI, and the FISI correlated −0.31 with the SF-12 Mental Component Summary. The authors conclude: validity and reliability were good in the Dutch FIQL, but inconclusive in the FISI, as published.

Watch out: This is the row's honesty anchor: the same study that found the FIQL good declined to endorse the FISI, and that asymmetry prints wherever this pack's stamp is summarised. The reference group's mean FISI of 23.17 is itself substantial — the index returns non-trivial scores in people without an FI diagnosis, which is part of why cross-population comparisons are hazardous for a weighted index. The FISI's own internal-consistency coefficient is not stated in the abstract record and none is printed from this anchor.

Source: 't Hoen et al. The fecal incontinence quality of life scale (FIQL) and fecal incontinence severity index (FISI): Validation of the Dutch versions. Neurourology and urodynamics. 2017. PMID: 27028557. Registry ID: none in the record. MeSH: Adaptation, Psychological · Adult · Aged · Emotions · Fecal Incontinence/diagnosis,psychology · Female · Humans · Life Style · Male · Middle Aged · Patient Reported Outcome Measures · Quality of Life/psychology · Reproducibility of Results · Severity of Illness Index · Surveys and Questionnaires

Card 4 — Synthesis: the FISI is reproducible and internally consistent in its Italian and Turkish validations (α 0.73–0.81; inter-rater 0.871) and separates patients from reference participants in the Dutch study — yet the Dutch authors judged its validity and reliability 'inconclusive', no derivation anchor is carded, and its population-derived weights bound how far any score travels

Study: Synthesis

Population: Synthesis of the 3 reports carded above (100 Italian patients — shared report with pack #8192; 58 Turkish women; 55 Dutch patients + 277 reference participants).

Summary: Synthesis: the FISI is reproducible and internally consistent in its Italian and Turkish validations (α 0.73–0.81; inter-rater 0.871) and separates patients from reference participants in the Dutch study — yet the Dutch authors judged its validity and reliability 'inconclusive', no derivation anchor is carded, and its population-derived weights bound how far any score travels

Result: The verified set holds: a prospective Italian validation with the family's strongest reliability figures; a Turkish validation adding the family's only physiological criterion limb (manometry) and the patient-vs-surgeon α pair; and a Dutch evaluation whose discriminative separation coexists with its authors' inconclusive verdict on the FISI itself. No pooled coefficient is printed: the three studies report different property mixes (the Dutch record gives no FISI α; the Turkish record gives no test–retest coefficient), and the weighting-matrix construction means scores are not automatically comparable across the populations studied.

Watch out: Composition discipline: 3 language-version reports, 0 derivation anchors; PMID 37368229 shared with #8192 by row direction, stated on both faces. Cross-points in prose only: #8192 (St Mark's / Vaizey), #8188 (ICIQ-OAB), #8156 (BFLUTS), #8087 (OAB-q).

Source: Synthesis of the reports carded above; no additional source.