SourceMed · Shelf #8193 in the ask interface
Wexner (Cleveland Clinic Florida) fecal incontinence score (five frequency items — solid, liquid, gas, pad use, lifestyle alteration — each 0–4, total 0–20): self- vs interview-administration ICC 0.92 (n = 105 — shared report, Wexner limb only); VAS grading neither concordant nor interchangeable (limits +5.4 to −10.6, n = 103); Italian validation Spearman 0.937, inter-rater 0.913 (n = 100 — shared report, Wexner limb only); test–retest under the name Cleveland Clinic score ICC 0.858 (0.611 to 0.940, n = 39 — shared report, Wexner limb only) — 4 reports, 3 shared
Shelf #8193 · Liver & gut
MEASUREMENT PROPERTIES — supported with sharing and wide-interval caveats: self- vs interview-administration ICC 0.92 with near-identical means (8.44 self vs 8.26 interview) and item κ 0.64–0.94 (n = 105; SHARED REPORT — PMID 31172220, Wexner limb only here, its St Mark's limb is carded on pack #8192); a visual-analogue grade was neither concordant nor interchangeable with the score (95% limits +5.4 to −10.6, n = 103); Italian prospective validation Spearman 0.937 and inter-rater 0.913 for the combined Vaizey-and-Wexner questionnaire (n = 100; SHARED REPORT — PMID 37368229, Wexner limb only here, its FISI limb is on pack #8191 and its St Mark's limb on pack #8192); test–retest under the name Cleveland Clinic score ICC 0.858 (0.611 to 0.940) at 6 weeks (n = 39 recruited, 31 completing; SHARED REPORT — PMID 24819105, Wexner/Cleveland Clinic limb only here, its St Mark's limb is on pack #8192); a measurement stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2013–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the Wexner (Cleveland Clinic Florida) fecal incontinence score (five frequency items — solid, liquid, gas, pad use, lifestyle alteration — each 0–4, total 0–20) — how closely do self-administered and interview-administered scores agree, how concordant is a visual-analogue grading with the score, what did the Italian prospective validation establish, and what test–retest reliability was found under the score's other name, the Cleveland Clinic score?
Balance of the evidence
Composition prints on the face: 4 reports, 347 patients in total (105 + 103 + 100 + 39), 3 of them SHARED reports carded here for the Wexner limb only under the pre-adjudicated sharing for this pack — PMID 31172220 (its St Mark's limb is carded on pack #8192), PMID 37368229 (its FISI limb is carded on pack #8191 and its St Mark's limb on pack #8192) and PMID 24819105 (its St Mark's limb is carded on pack #8192); the sharing prints on the face, the balance and the Synthesis of this pack and on the neighbouring packs. The Cleveland Clinic score named in PMID 24819105 IS the Wexner score under its other name — one instrument, not two, and this pack exists partly to keep the two names from splitting into two shelves. The VAS anchor's lesson is negative and prints at weight: a global analogue grade is not a substitute for the score. No derivation anchor is carded. A measurement-properties shelf, not a continence-treatment shelf. Cross-points in prose only: pack #8191 (FISI), pack #8192 (St Mark's / Vaizey), pack #8188 (ICIQ-OAB), pack #8156 (BFLUTS).
MeSH: Adult · Aged · Aged, 80 and over · Fecal Incontinence/diagnosis* · Female · Humans · Interviews as Topic/standards* · Male · Middle Aged · Norway · Reproducibility of Results · Severity of Illness Index · Surveys and Questionnaires/standards* · Young Adult · Adaptation, Psychological · Fecal Incontinence/psychology* · Life Style · Quality of Life/psychology* · Regression Analysis · Severity of Illness Index* · Shame · Surveys and Questionnaires · Quality of Life* · Prospective Studies · Fecal Incontinence*/diagnosis · Language · Italy · Fecal Incontinence/physiopathology*,psychology*
Cards (5)
Card 1 — Administration-mode agreement (Norderval 2019, International Urogynecology Journal — 105 consecutive clinic patients (30 male) completing a single combined questionnaire from which both Wexner and St Mark's scores derive, interviewers blinded to the self-report): Wexner self vs interview ICC 0.92 with near-identical means (8.44 self vs 8.26 interview), item κ 0.64–0.94 — SHARED REPORT, Wexner limb only carded here; its St Mark's limb is carded on pack #8192
Study: Agreement study (primary report) — self- vs interview administration; SHARED REPORT (Wexner limb only on this pack)
Population: 105 consecutive patients (30 male) at incontinence outpatient clinics in Sarpsborg and Tromsø, Norway, completed the self-administered questionnaire before their appointment and were then interviewed for the St Mark's and Wexner scores by interviewers blinded to the self-report; the self-administered form was incomplete in 6 cases (5.7%) and the interview form in 2.
Summary: Administration-mode agreement (Norderval 2019, International Urogynecology Journal — 105 consecutive clinic patients (30 male) completing a single combined questionnaire from which both Wexner and St Mark's scores derive, interviewers blinded to the self-report): Wexner self vs interview ICC 0.92 with near-identical means (8.44 self vs 8.26 interview), item κ 0.64–0.94 — SHARED REPORT, Wexner limb only carded here; its St Mark's limb is carded on pack #8192
Result: Agreement between interview-obtained and self-administered Wexner scores was almost perfect (ICC 0.92), with mean scores of 8.26 (interview) versus 8.44 (self-administered; p = 0.42). Item agreement across both scoring systems was substantial to almost perfect (κ 0.64–0.94). The authors conclude both scores can be completed by patients using a single questionnaire, with derived scores highly consistent with interview-obtained scores, as published.
Watch out: Pre-adjudicated sharing: this PMID is carded here for its Wexner limb only and on pack #8192 for its St Mark's limb — one study, two shelves, stated on both faces; it must not be counted as two independent reports in any cross-pack tally. Total-score agreement (ICC 0.92) coexists with item κ down to 0.64 — wherever a severity band or single item drives a decision, the item-level figure is the honest one.
Source: Norderval et al. Strong agreement between interview-obtained and self-administered Wexner and St. Mark's scores using a single questionnaire. International urogynecology journal. 2019. PMID: 31172220. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Fecal Incontinence/diagnosis* · Female · Humans · Interviews as Topic/standards* · Male · Middle Aged · Norway · Reproducibility of Results · Severity of Illness Index · Surveys and Questionnaires/standards* · Young Adult
Card 2 — Visual-analogue grading vs the Jorge-Wexner score (Devesa 2013, Techniques in Coloproctology — 103 consecutive unselected patients with faecal incontinence of different aetiologies): the VAS and the score were neither concordant nor interchangeable, with differences in a given patient fluctuating between +5.4 and −10.6 (95% limits)
Study: Validation study (primary report) — VAS concordance
Population: 103 consecutive unselected patients affected by faecal incontinence of different aetiologies, prospectively included; continence and quality of life over the last month were scored by the Jorge-Wexner score, the Rockwood FIQL scale, a visual analogue scale for faecal incontinence (VASFI) and a visual analogue scale for quality of life (VASQL); patients unable to respond accurately to one or more questionnaires were excluded.
Summary: Visual-analogue grading vs the Jorge-Wexner score (Devesa 2013, Techniques in Coloproctology — 103 consecutive unselected patients with faecal incontinence of different aetiologies): the VAS and the score were neither concordant nor interchangeable, with differences in a given patient fluctuating between +5.4 and −10.6 (95% limits)
Result: Comparison of VASFI with the Jorge-Wexner score shows the two methods are neither concordant nor interchangeable, and in a given patient the differences between both may fluctuate between 5.4 and −10.6 (95% confidence interval), as published. Correlation between VASFI and VASQL was middling (r² = 0.543, β coefficient −0.538); after multiple regression VASFI correlated significantly only with the embarrassment subscale of FIQL. The authors conclude a VAS for faecal incontinence cannot replace the Jorge-Wexner score.
Watch out: This is a negative anchor and prints at weight: it does not validate the Wexner score itself — it shows a single global analogue grade cannot substitute for it. The +5.4 to −10.6 limits are on a 0–20 score, i.e. disagreement spanning most of the scale in individual patients.
Source: Devesa et al. Visual analogue scales for grading faecal incontinence and quality of life: their relationship with the Jorge-Wexner score and Rockwood scale. Techniques in coloproctology. 2013. PMID: 22936592. Registry ID: none in the record. MeSH: Adaptation, Psychological · Aged · Fecal Incontinence/psychology* · Female · Humans · Life Style · Male · Middle Aged · Quality of Life/psychology* · Regression Analysis · Severity of Illness Index* · Shame · Surveys and Questionnaires
Card 3 — Italian prospective validation (Ortenzi 2023, Updates in Surgery — 100 Italian-speaking patients, each questionnaire administered twice by two independent raters): Vaizey-and-Wexner α 0.755 / 0.727 across administrations, Spearman correlation 0.937 and inter-rater reliability 0.913 — SHARED REPORT, Wexner limb only carded here; its FISI limb is carded on pack #8191 and its St Mark's limb on pack #8192
Study: Prospective validation study (primary report) — Italian version; SHARED REPORT (Wexner limb only on this pack)
Population: 100 Italian-speaking patients completed the forward–backward translated Italian Vaizey and Wexner questionnaire (and the FISI) twice, administered independently by two different raters; reliability and validity of the Italian versions were assessed.
Summary: Italian prospective validation (Ortenzi 2023, Updates in Surgery — 100 Italian-speaking patients, each questionnaire administered twice by two independent raters): Vaizey-and-Wexner α 0.755 / 0.727 across administrations, Spearman correlation 0.937 and inter-rater reliability 0.913 — SHARED REPORT, Wexner limb only carded here; its FISI limb is carded on pack #8191 and its St Mark's limb on pack #8192
Result: Cronbach α for the first and second Vaizey and Wexner administrations was 0.755 and 0.727 respectively. Spearman correlation was 0.937 and inter-rater reliability 0.913 for the Vaizey and Wexner questionnaire. The authors conclude the Italian versions showed good consistency, reliability and reproducibility, with good psychometric properties, as published.
Watch out: Pre-adjudicated sharing: this PMID is carded here for its Wexner limb only, on pack #8191 for its FISI limb and on pack #8192 for its St Mark's limb — one study, three shelves, stated on every face; it must not be counted as independent reports in any cross-pack tally. In this record the Vaizey and Wexner instruments were administered as a combined questionnaire, so the 0.937 / 0.913 figures attach to that combined administration as published, not to the Wexner score alone.
Source: Ortenzi et al. Prospective Italian validation of the Vaizey and Wexner and fecal incontinence severity index (FISI) questionnaires. Updates in surgery. 2023. PMID: 37368229. Registry ID: none in the record. MeSH: Humans · Quality of Life* · Reproducibility of Results · Prospective Studies · Fecal Incontinence*/diagnosis · Severity of Illness Index · Language · Surveys and Questionnaires · Italy
Card 4 — Test–retest reliability under the score's other name, the Cleveland Clinic score (Hussain 2014, Diseases of the Colon and Rectum — 39 patients (34 female, median age 65) assessed twice 6 weeks apart with no treatment change; 31 completed the second assessment): Cleveland Clinic (Wexner) intraobserver ICC 0.858 (0.611 to 0.940) — the wide interval prints in full; interobserver ICCs 0.795–0.945 — SHARED REPORT, Wexner/Cleveland Clinic limb only carded here; its St Mark's limb is carded on pack #8192; small N (39) prints on the face
Study: Reliability study (primary report) — test–retest / intraobserver; SHARED REPORT (Wexner/Cleveland Clinic limb only on this pack); small N prints
Population: 39 prospectively recruited patients with fecal incontinence completed the St Mark's score, the Cleveland Clinic score, the Rockwood quality-of-life scale and a visual analogue scale at recruitment and again 6 weeks later with no alteration to medications or treatment; only 31 completed the second assessment. A physician and a nurse also completed the severity scores for interobserver reliability.
Summary: Test–retest reliability under the score's other name, the Cleveland Clinic score (Hussain 2014, Diseases of the Colon and Rectum — 39 patients (34 female, median age 65) assessed twice 6 weeks apart with no treatment change; 31 completed the second assessment): Cleveland Clinic (Wexner) intraobserver ICC 0.858 (0.611 to 0.940) — the wide interval prints in full; interobserver ICCs 0.795–0.945 — SHARED REPORT, Wexner/Cleveland Clinic limb only carded here; its St Mark's limb is carded on pack #8192; small N (39) prints on the face
Result: The intraobserver (test–retest) ICC for the Cleveland Clinic score was 0.858 (95% CI 0.611 to 0.940); interobserver reliability ranged 0.795–0.945 for the Cleveland Clinic score. Quality-of-life domain ICCs ranged 0.864–0.938 and the VAS ICC was 0.958 (0.906 to 0.982). The authors conclude the current severity and quality-of-life tools have excellent intra- and interobserver reliability, as published, while noting the completion shortfall increases the risk of nonresponse error.
Watch out: Pre-adjudicated sharing: this PMID is carded here for its Cleveland Clinic (Wexner) limb only and on pack #8192 for its St Mark's limb — stated on both faces. The name variant prints: the Cleveland Clinic score in this record IS the Wexner score. The point estimate (0.858) sits in an interval running from 0.611 to 0.940 — with 39 recruited and 31 completing, this anchor supports at least fair-to-good, plausibly excellent reliability rather than a precise claim, and the interval prints wherever the figure is used.
Source: Hussain et al. The test-retest reliability of fecal incontinence severity and quality-of-life assessment tools. Diseases of the colon and rectum. 2014. PMID: 24819105. Registry ID: none in the record. MeSH: Aged · Fecal Incontinence/physiopathology*,psychology* · Female · Humans · Male · Middle Aged · Prospective Studies · Quality of Life* · Reproducibility of Results · Severity of Illness Index* · Surveys and Questionnaires
Card 5 — Synthesis: the Wexner score agrees almost perfectly across administration modes (ICC 0.92), is reproducible in Italian prospective validation (combined-administration Spearman 0.937, inter-rater 0.913) and over 6 weeks under its Cleveland Clinic name (ICC 0.858, wide interval 0.611 to 0.940, n = 39), while a visual-analogue grade cannot substitute for it — on four reports, three of them shared with the neighbouring continence packs for the Wexner limb only
Study: Synthesis
Population: Synthesis of the 4 reports carded above (105 Norwegian clinic patients — shared, Wexner limb only; 103 VAS-comparison patients; 100 Italian patients — shared, Wexner limb only; 39 test–retest patients, 31 completing — shared, Wexner limb only). Total documented patients 347, with the sharing stated so no patient is counted twice across packs.
Summary: Synthesis: the Wexner score agrees almost perfectly across administration modes (ICC 0.92), is reproducible in Italian prospective validation (combined-administration Spearman 0.937, inter-rater 0.913) and over 6 weeks under its Cleveland Clinic name (ICC 0.858, wide interval 0.611 to 0.940, n = 39), while a visual-analogue grade cannot substitute for it — on four reports, three of them shared with the neighbouring continence packs for the Wexner limb only
Result: The verified set holds: a blinded administration-mode study showing self-completion can replace interview for total scores (ICC 0.92) with weaker item-level agreement (κ from 0.64); a negative concordance study (a VAS grade is neither concordant nor interchangeable with the score, limits +5.4 to −10.6); a prospective Italian validation of the combined Vaizey-and-Wexner administration; and a small test–retest study under the Cleveland Clinic name whose interval width is itself the finding. No pooled coefficient is printed across shared and unshared limbs, and no anchor establishes a minimal important difference — absent, not implied.
Watch out: Composition discipline: 4 reports (3 shared, Wexner limb only on this pack, printed as shared on every card) — PMID 31172220 shared with #8192, PMID 37368229 shared with #8191 and #8192, PMID 24819105 shared with #8192, all per the pre-adjudicated sharing for this pack. Cross-points in prose only: #8191 (FISI), #8192 (St Mark's / Vaizey), #8188 (ICIQ-OAB), #8156 (BFLUTS).
Source: Synthesis of the reports carded above; no additional source.