SourceMed · Shelf #8194 in the ask interface
NBD score — Neurogenic Bowel Dysfunction score (10 weighted items, banded very minor / minor / moderate / severe, for spinal cord injury): derivation in 424 Danish SCI respondents (item reproducibility n = 20, validity n = 18); Dutch SCI version α 0.56 / 0.30, test–retest ICC 0.87 (58 patients + 50 references); Dutch version transported to multiple sclerosis α 0.57 / 0.41, ICC 0.78 (61 patients + 50 controls) — 3 reports
Shelf #8194 · Brain, stroke & mind
MEASUREMENT PROPERTIES — supported as a formative weighted score, with low internal consistency printed as expected for its construction: derivation from a 39-item survey of 589 Danish spinal-cord-injured patients (424 responded; item reproducibility tested in 20 and validity in 18), its 10 items weighted by their odds ratios for quality-of-life impact and separating the no / little / some / major impact groups (all p < .001), with no total-score reliability coefficient in the derivation record and none printed; Dutch SCI version α 0.56 and 0.30 with test–retest ICC 0.87 (58 patients + 50 references); Dutch version in multiple sclerosis α 0.57 and 0.41 with reproducibility ICC 0.78 (61 patients + 50 controls) — the low α values print with the formative-index explanation, not as a defect and not omitted; a measurement stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 2006–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the NBD score (Neurogenic Bowel Dysfunction score — 10 weighted items on frequency, time, uneasiness, incontinence, medication, finger stimulation and perianal skin problems, banded very minor / minor / moderate / severe, for spinal cord injury) — what did its original development and validation establish, and what reliability and validity did the Dutch version find in spinal cord injury and, transported, in multiple sclerosis?
Balance of the evidence
Composition prints on the face: 3 reports — 1 derivation report (programme-labelled: the Krogh group's own report; 424 respondents to a survey sent to 589 patients, with small item-level subsamples of 20 and 18 printed) and 2 Dutch-version validations by the same Dutch group in two different neurogenic populations (spinal cord injury, 58 patients + 50 references; multiple sclerosis, 61 patients + 50 controls — a population transport beyond the derivation population, printed as such; SCI and MS figures are never pooled). SLATE-VS-RECORD NOTE: the slate row's question wording named 'Dutch and Chinese versions'; the verified anchors are the Dutch SCI validation and the Dutch version transported to MS — no Chinese version is among the fetched anchors, and the pack question follows the records. The NBD score is a formative weighted index: its items need not correlate, so low Cronbach α is expected for its construction and prints with that explanation. A measurement-properties shelf, not a bowel-treatment shelf. Cross-points in prose only: pack #8191 (FISI), pack #8192 (St Mark's / Vaizey), pack #8193 (Wexner).
MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Child · Constipation/etiology* · Cross-Sectional Studies · Disability Evaluation · Fecal Incontinence/etiology · Female · Gastrointestinal Diseases/etiology*,psychology · Humans · Logistic Models · Male · Middle Aged · Quality of Life · Reproducibility of Results · Sickness Impact Profile · Spinal Cord Injuries/complications*,psychology* · Surveys and Questionnaires · Urinary Incontinence/etiology* · Language · Neurogenic Bowel*/diagnosis,etiology,therapy · Spinal Cord Injuries*/complications,diagnosis
Cards (4)
Card 1 — Development and validation (Krogh 2006, Spinal Cord — 39-item questionnaire survey sent to 589 Danish spinal-cord-injured patients, 424 responded; item reproducibility tested in 20 patients and validity in 18): 10 items selected for acceptable reproducibility/validity and significant association with quality-of-life impact, weighted by their odds ratios; total scores differed significantly across the no / little / some / major QOL-impact groups (all p < .001) — programme-labelled: the Krogh group's own report; no total-score reliability coefficient is reported in this record and none is printed
Study: Development and validation study (primary report) — programme report; small item-level subsamples (n = 20 / 18) print
Population: 589 Danish spinal cord injured patients were sent a questionnaire covering background parameters (8 items), faecal incontinence (10), constipation (10), obstructed defecation (8) and impact on quality of life (3); 424 responded. Reproducibility of each item was tested in 20 patients and validity in 18.
Summary: Development and validation (Krogh 2006, Spinal Cord — 39-item questionnaire survey sent to 589 Danish spinal-cord-injured patients, 424 responded; item reproducibility tested in 20 patients and validity in 18): 10 items selected for acceptable reproducibility/validity and significant association with quality-of-life impact, weighted by their odds ratios; total scores differed significantly across the no / little / some / major QOL-impact groups (all p < .001) — programme-labelled: the Krogh group's own report; no total-score reliability coefficient is reported in this record and none is printed
Result: The 10 items meeting the criteria were: frequency of bowel movements (0–6 points), headache, perspiration or discomfort before or during defecation (0–2), tablets and drops against constipation (0–2 each), time used for each defecation (0–7), frequency of digital stimulation or evacuation (0–6), frequency of faecal incontinence (0–13), medication against faecal incontinence (0–4), flatus incontinence (0–2) and perianal skin problems (0–3). Differences in NBD score among patients reporting no, little, some or major impact on quality of life were statistically significant (all P < 0.001), as published.
Watch out: The derivation's item selection rested on small reproducibility (n = 20) and validity (n = 18) subsamples inside the 424-respondent survey — both numbers print and the score's foundation is only as firm as they allow. The abstract record reports no total-score reliability coefficient, and none may be printed from this anchor.
Source: Krogh et al. Neurogenic bowel dysfunction score. Spinal cord. 2006. PMID: 16344850. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Child · Constipation/etiology* · Cross-Sectional Studies · Disability Evaluation · Fecal Incontinence/etiology · Female · Gastrointestinal Diseases/etiology*,psychology · Humans · Logistic Models · Male · Middle Aged · Quality of Life · Reproducibility of Results · Sickness Impact Profile · Spinal Cord Injuries/complications*,psychology* · Surveys and Questionnaires · Urinary Incontinence/etiology*
Card 2 — Dutch version in spinal cord injury (van Doorn 2022, Spinal Cord — prospective validation, 58 SCI patients + 50 reference subjects): content validity adequate, α 0.56 and 0.30 — low, printed as the authors report it for this weighted/formative score — test–retest ICC 0.87, criterion validity against FIQL / FISI / EQ-5D-3L confirmed
Study: Validation study (primary report) — Dutch version, spinal cord injury
Population: 58 adult patients with spinal cord injury visiting a urology department in Rotterdam, the Netherlands, completed the NBD score, FIQL, FISI and EQ-5D-3L at baseline and 1–2 weeks afterward; a control group of 50 references recruited at a general practitioner's office completed the questionnaires once.
Summary: Dutch version in spinal cord injury (van Doorn 2022, Spinal Cord — prospective validation, 58 SCI patients + 50 reference subjects): content validity adequate, α 0.56 and 0.30 — low, printed as the authors report it for this weighted/formative score — test–retest ICC 0.87, criterion validity against FIQL / FISI / EQ-5D-3L confirmed
Result: Content validity was adequate, internal consistency was moderate (Cronbach α 0.56 and 0.30) and reproducibility was adequate (ICC 0.87). Criterion validity was confirmed; the NBD score correlated significantly with the FIQL, FISI and EQ-5D-3L. NBD scores in the patient group were significantly higher than in references, demonstrating good construct validity, as published.
Watch out: The α values (0.56 and 0.30) are low by reflective-scale standards; for a formative weighted index whose items need not correlate they are expected, and they print with that explanation rather than as a defect or silently omitted. The two α values are as the record reports them (two administrations); no single α may be substituted.
Source: van Doorn et al. Neurogenic bowel dysfunction score in spinal cord-injured patients: translation and validation of the Dutch-language NBD score. Spinal cord. 2022. PMID: 34349233. Registry ID: none in the record. MeSH: Adult · Humans · Language · Neurogenic Bowel*/diagnosis,etiology,therapy · Quality of Life · Reproducibility of Results · Spinal Cord Injuries*/complications,diagnosis · Surveys and Questionnaires
Card 3 — Dutch version transported to multiple sclerosis (van Doorn 2022, International Journal of MS Care — 61 MS patients + 50 controls): content validity adequate, α 0.57 and 0.41, reproducibility ICC 0.78, moderate-to-strong correlations with FIQL / FISI / EQ-5D-3L — a different neurogenic population from the derivation, printed as a transport
Study: Validation study (primary report) — Dutch version, multiple sclerosis (population transport)
Population: 61 adult patients with multiple sclerosis visiting a urology department completed the NBD score, FIQL, FISI and EQ-5D-3L, and completed them again after 1–2 weeks (retest); a control group of 50 recruited at a general practitioner's practice completed the questionnaires once.
Summary: Dutch version transported to multiple sclerosis (van Doorn 2022, International Journal of MS Care — 61 MS patients + 50 controls): content validity adequate, α 0.57 and 0.41, reproducibility ICC 0.78, moderate-to-strong correlations with FIQL / FISI / EQ-5D-3L — a different neurogenic population from the derivation, printed as a transport
Result: Content validity was adequate, internal consistency was moderate (Cronbach α = 0.57 and 0.41), and reproducibility was excellent (intraclass correlation coefficient = 0.78) in the authors' wording. Criterion validity was confirmed; the NBD score correlated moderately/strongly with the FIQL, FISI and EQ-5D-3L. NBD scores in the patient group were significantly higher than in the control group, demonstrating good construct validity, as published.
Watch out: This is a transport beyond the score's derivation population (spinal cord injury) — its figures print as MS figures and are never pooled with the SCI figures. The record carries no MeSH (printed as 'none in the record' on the source line). The authors call an ICC of 0.78 'excellent'; the number prints and the adjective is theirs.
Source: van Doorn et al. Validation of the Dutch-Language Version of the Neurogenic Bowel Dysfunction Score in Patients With Multiple Sclerosis. International journal of MS care. 2022. PMID: 35462867. Registry ID: none in the record. MeSH: none in the record
Card 4 — Synthesis: the NBD score is a quality-of-life-anchored formative index whose Dutch validations show adequate reproducibility (ICC 0.87 in SCI, 0.78 in MS) and confirmed criterion validity, with low internal consistency (α 0.30–0.57) that its weighted construction predicts — on three reports, one derivation and two same-group Dutch validations in two populations
Study: Synthesis
Population: Synthesis of the 3 reports carded above (424 Danish SCI respondents, with item subsamples of 20 and 18; 58 Dutch SCI patients + 50 references; 61 Dutch MS patients + 50 controls). Populations are never pooled.
Summary: Synthesis: the NBD score is a quality-of-life-anchored formative index whose Dutch validations show adequate reproducibility (ICC 0.87 in SCI, 0.78 in MS) and confirmed criterion validity, with low internal consistency (α 0.30–0.57) that its weighted construction predicts — on three reports, one derivation and two same-group Dutch validations in two populations
Result: The verified set holds: a programme derivation that selected and weighted 10 items by their association with quality-of-life impact; a Dutch SCI validation with adequate test–retest reproducibility and criterion validity against FIQL, FISI and EQ-5D-3L; and a Dutch MS transport with the same pattern. No total-score reliability coefficient exists in the derivation record, no minimal important difference is established in any anchor, and both absences print as absent.
Watch out: Composition discipline: 3 reports / 3 datasets, the two validations from one Dutch group — independent-population transport, not independent-programme replication, and printed as such. Cross-points in prose only: #8191 (FISI), #8192 (St Mark's), #8193 (Wexner).
Source: Synthesis of the reports carded above; no additional source.