SourceMed · Shelf #8206 in the ask interface

Rhodes Index of Nausea, Vomiting, and Retching (INVR) family — 8-item daily self-report of nausea, vomiting and retching occurrence, duration and distress: parallel-form agreement with the INV-2 predecessor high in 159 subjects (no numeric coefficient printed in the record); modified form in ambulatory surgery α 0.897 with one item dropped, one factor at 67% of variance (190 patients); Persian chemotherapy version α 0.88, item weighted κ 0.63–0.79 (94 patients) — 3 reports, no derivation anchor carded

Shelf #8206 · Cancer

MEASUREMENT PROPERTIES — format equivalence and translation reliability supported; factor behaviour population-dependent: parallel-form agreement with the INV-2 predecessor was high in 159 mixed subjects, with INVR responses more frequently internally consistent where the forms disagreed (no numeric coefficient is printed in the record and none is claimed); a modified form in 190 symptomatic ambulatory-surgery patients gave α 0.897 as a single factor (67% of variance) only after one of eight items was dropped, with a different symptom mix from chemotherapy or pregnancy; the Persian chemotherapy version gave α 0.88 with item test–retest weighted κ 0.63–0.79 (94 patients); composition 1 parallel-form report + 1 modified-form secondary analysis + 1 language validation, no derivation anchor; a measurement stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 1999–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the Rhodes INVR family (Index of Nausea, Vomiting, and Retching — an 8-item daily self-report of nausea, vomiting and retching occurrence, duration and distress, and its predecessor forms) — what did the INVR parallel-form study establish, what did the modified version show in ambulatory surgery, and what reliability did the Persian chemotherapy version find?

Balance of the evidence

Composition prints on the face: 3 reports of three different kinds — 1 parallel-form report (the Rhodes group's own INVR vs INV-2 study), 1 modified-form secondary analysis in ambulatory surgery, and 1 language validation (Persian, chemotherapy). The family's original 1980s derivation reports were not returned under the forms tried at mining and are not carded. The ambulatory-surgery anchor's lesson prints at weight: the instrument's factor behaviour is population-dependent (one factor, one item dropped, different symptom mix), so INVR figures from chemotherapy samples do not transport to post-operative samples by default. A measurement-properties shelf for the daily symptom-experience diary. Cross-points in prose only: pack #8205 (MAT — the once-per-cycle recall tool validated against this diary), pack #8207 (FLIE — impact on daily life, not symptom occurrence).

MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Female · Humans · Hyperemesis Gravidarum/nursing · Male · Middle Aged · Nausea/nursing* · Obstetric Nursing* · Oncology Nursing* · Postoperative Nausea and Vomiting/nursing · Pregnancy · Reproducibility of Results · Severity of Illness Index* · Vomiting/nursing* · Ambulatory Surgical Procedures/adverse effects* · Factor Analysis, Statistical · Patient Discharge · Postoperative Nausea and Vomiting/classification*,diagnosis · Antineoplastic Agents/adverse effects* · Cross-Cultural Comparison · Nausea/chemically induced*,diagnosis · Neoplasms/drug therapy* · Nursing Assessment/methods · Psychometrics/instrumentation* · Quality of Life · Surveys and Questionnaires · Translations · Vomiting/chemically induced*,diagnosis · Young Adult

Cards (4)

Card 1 — Parallel-form reliability (Rhodes 1999, Oncology Nursing Forum — 159 subjects: 40 obstetrical, 60 oncological, 59 medical/surgical; INVR and its predecessor INV-2 completed 30–60 minutes apart in counterbalanced order): high agreement between forms, INVR responses more frequently internally consistent where the forms disagreed — programme report (the Rhodes group's own study); no numeric correlation coefficient is printed in the record

Study: Parallel-form reliability study (primary report) — INVR vs INV-2; programme report

Population: Convenience sample of 159 subjects at a large Midwestern teaching hospital and a cancer centre: 40 obstetrical, 60 oncological and 59 medical/surgical patients. Half completed the INVR first and half the INV-2 first, the two forms administered approximately 30–60 minutes apart.

Summary: Parallel-form reliability (Rhodes 1999, Oncology Nursing Forum — 159 subjects: 40 obstetrical, 60 oncological, 59 medical/surgical; INVR and its predecessor INV-2 completed 30–60 minutes apart in counterbalanced order): high agreement between forms, INVR responses more frequently internally consistent where the forms disagreed — programme report (the Rhodes group's own study); no numeric correlation coefficient is printed in the record

Result: A high rate of agreement was found between responses to the two forms. In cases of clear disagreement, responses to the INVR were more frequently consistent than responses to the original form. The authors conclude the INVR has tested reliability and is more user friendly for patients and providers than the INV-2, as published. The record reports the agreement qualitatively — no equivalency correlation coefficient is printed in the abstract, and none is carded here.

Watch out: This is a format-equivalence study, not a validation against an external standard: it shows the new format agrees with its own predecessor, administered under an hour apart, when recall of the first form's answers is still fresh. The absence of a printed coefficient in the record is itself printed — no agreement number may be quoted from this anchor. The family's original 1980s derivation reports were not returned under the forms tried at mining and are not carded.

Source: Rhodes et al. The Index of Nausea, Vomiting, and Retching: a new format of the lndex of Nausea and Vomiting. Oncology nursing forum. 1999. PMID: 10382187. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Female · Humans · Hyperemesis Gravidarum/nursing · Male · Middle Aged · Nausea/nursing* · Obstetric Nursing* · Oncology Nursing* · Postoperative Nausea and Vomiting/nursing · Pregnancy · Reproducibility of Results · Severity of Illness Index* · Vomiting/nursing*

Card 2 — Modified form in ambulatory surgery (Fetzer 2004, Journal of Advanced Nursing — secondary analysis of 190 patients with post-discharge nausea and vomiting, interviewed 24 hours after discharge): α 0.897, a single factor accounting for 67% of variance after one of the eight items was dropped — a modified form in a different population, printed as such

Study: Psychometric evaluation (primary report) — modified form, secondary analysis in ambulatory surgery

Population: 190 adult ambulatory surgery patients who reported post-discharge nausea and vomiting, drawn from a descriptive study of risk factors for post-discharge nausea and vomiting; patients completed a modified Rhodes Index of Nausea and Vomiting by phone interview 24 hours after discharge.

Summary: Modified form in ambulatory surgery (Fetzer 2004, Journal of Advanced Nursing — secondary analysis of 190 patients with post-discharge nausea and vomiting, interviewed 24 hours after discharge): α 0.897, a single factor accounting for 67% of variance after one of the eight items was dropped — a modified form in a different population, printed as such

Result: Reliability analysis (α = 0.897) indicated the modified Rhodes INV measured upper gastrointestinal distress as a single concept in this post-discharge ambulatory surgical sample. One item of the 8-item scale was dropped. Principal component analysis extracted one factor accounting for 67% of the variance, with all retained items loading. The authors conclude that upper gastrointestinal distress after ambulatory surgery discharge comprises a different symptom mix than during other high-risk events such as pregnancy or chemotherapy, as published.

Watch out: Three qualifiers print together: the form was modified (one item dropped), the sample was selected for having symptoms (only patients who reported post-discharge nausea and vomiting), and the population is post-operative, not chemotherapy. The anchor's own lesson is that the instrument's factor behaviour is population-dependent — INVR figures from chemotherapy samples do not transport to post-operative samples by default, and this card is not chemotherapy evidence.

Source: Fetzer et al. Evaluation of the Rhodes Index of Nausea and Vomiting for ambulatory surgery patients. Journal of advanced nursing. 2004. PMID: 15186470. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Ambulatory Surgical Procedures/adverse effects* · Factor Analysis, Statistical · Female · Humans · Male · Middle Aged · Patient Discharge · Postoperative Nausea and Vomiting/classification*,diagnosis · Reproducibility of Results

Card 3 — Persian version in chemotherapy (Moradian 2014, European Journal of Cancer Care — 94 cancer patients): α 0.88, item test–retest weighted κ 0.63–0.79

Study: Validation study (primary report) — Persian version, chemotherapy population

Population: 94 cancer patients recruited from a cancer research centre in Mashhad, Iran, assessed with the forward–backward translated Persian version of the Rhodes INVR for chemotherapy-induced nausea and vomiting; internal consistency and test–retest reliability were examined in a multiphase instrumentation study.

Summary: Persian version in chemotherapy (Moradian 2014, European Journal of Cancer Care — 94 cancer patients): α 0.88, item test–retest weighted κ 0.63–0.79

Result: The inter-item correlation measured by Cronbach α was 0.88. Test–retest reliability measured by weighted κ was between 0.63 and 0.79 across items, indicating 'substantial agreement' and stability between initial and subsequent administrations for each item. The authors conclude the Persian INVR is acceptable for use among Iranian cancer patients, as published.

Watch out: Item-level weighted κ (0.63–0.79) is what this record reports — no total-score test–retest coefficient is stated, and none may be printed from this anchor. A single-centre translation validation: it establishes the Persian form's stability in Iranian chemotherapy patients, not the English original's properties.

Source: Moradian et al. Translation and psychometric assessment of the Persian version of the Rhodes Index of Nausea, Vomiting and Retching (INVR) scale for the assessment of chemotherapy-induced nausea and vomiting. European journal of cancer care. 2014. PMID: 24661358. Registry ID: none in the record. MeSH: Adult · Aged · Antineoplastic Agents/adverse effects* · Cross-Cultural Comparison · Female · Humans · Male · Middle Aged · Nausea/chemically induced*,diagnosis · Neoplasms/drug therapy* · Nursing Assessment/methods · Psychometrics/instrumentation* · Quality of Life · Reproducibility of Results · Severity of Illness Index* · Surveys and Questionnaires · Translations · Vomiting/chemically induced*,diagnosis · Young Adult

Card 4 — Synthesis: the INVR family's verified base is one parallel-form study against its own predecessor (no coefficient printed in the record), one modified-form secondary analysis whose single-factor, item-dropped structure shows the instrument behaves differently after surgery, and one Persian chemotherapy validation (α 0.88, item κ 0.63–0.79) — 3 reports, no derivation anchor, and no anchor validating the diary against observed episodes

Study: Synthesis

Population: Synthesis of the 3 reports carded above: 159 mixed obstetrical/oncological/medical-surgical subjects (parallel forms); 190 symptomatic ambulatory-surgery patients (modified form, secondary analysis); 94 Iranian chemotherapy patients (Persian version). Populations are never pooled: obstetric, post-operative and chemotherapy symptom experiences are different spectra.

Summary: Synthesis: the INVR family's verified base is one parallel-form study against its own predecessor (no coefficient printed in the record), one modified-form secondary analysis whose single-factor, item-dropped structure shows the instrument behaves differently after surgery, and one Persian chemotherapy validation (α 0.88, item κ 0.63–0.79) — 3 reports, no derivation anchor, and no anchor validating the diary against observed episodes

Result: The verified set holds: format equivalence with the INV-2 predecessor (qualitative agreement, INVR more internally consistent on disagreements); a single-concept modified form in post-discharge surgical patients with one item dropped and 67% of variance on one factor; and a Persian chemotherapy form with α 0.88 and substantial item-level stability. The family's original 1980s derivation reports were not returned under the forms tried at mining and are not carded, so the shelf's base begins at the 1999 parallel-form study. No pooled reliability coefficient is printed across forms and populations.

Watch out: Composition discipline: 3 reports of three different kinds (parallel-form, modified-form secondary analysis, language validation) — the composition prints because no two anchors measure the same property in the same population. The INVR is also the comparator criterion for the whole MAT shelf (pack #8205) and appears inside the FLIE shelf's convergence figures (pack #8207); those uses are cross-points in prose only, not additional INVR evidence.

Source: Synthesis of the reports carded above; no additional source.