SINBAD diabetic-foot-ulcer classification — six dichotomous components (site, ischaemia, neuropathy, bacterial infection, area, depth) summed 0–6: single-observer reliability ICC 0.44 vs multiple-observer 0.91 (37 patients, 12 observers); major-amputation AUROC 0.74 at threshold ≥5, weakest of four systems (342 Peruvian patients); the only one of three systems discriminating outcomes prospectively (medians 5 vs 4 vs 2, p = 0.018; 107 patients) — graduated Norton composition: 0 dedicated-with-data reports + 3 shared primaries
Shelf #8210 · Diabetes, glucose & metabolism
PREDICTIVE PERFORMANCE — mixed across three shared primaries; no dedicated validation with data: single-observer inter-rater reliability only slight-to-moderate (ICC 0.44; multiple-observer 0.91; infection 0.28 and ischaemia 0.26 the worst single-observer components) in 37 patients rated by 12 observers; major-amputation AUROC 0.74 at best threshold ≥5 in 342 Peruvian hospital patients — the weakest of the four systems compared (Saint Elian 0.90, University of Texas 3D 0.81, Meggitt-Wagner 0.81), printed as such; prospectively the only one of three systems whose scores discriminated definitive outcomes (medians 5 amputation vs 4 grafting vs 2 secondary healing, p = 0.018) in 107 patients; composition 0 dedicated-with-data reports + 3 shared primaries (the Norton composition); the titled validity-and-reliability report (PMID 37861669) was fetched and NOT counted — its abstract reports no sample and no coefficient
Stamped: 2026-11-28.
Evidence published: 2016–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What measurement evidence supports the SINBAD diabetic-foot-ulcer classification (six dichotomous components — site, ischaemia, neuropathy, bacterial infection, area, depth — summed 0–6) — what inter-observer reliability did the three-system comparison find, what prognostic performance did the Peruvian external validation find for major amputation, and how did SINBAD compare with DUSS and the University of Texas system prospectively?
Balance of the evidence
Composition prints on the face (graduated row — Slate 31 Audit B15 discharged, on the Norton composition): 0 dedicated-with-data reports + 3 shared primaries — every anchor is a multi-system comparison in which SINBAD is one limb (reliability vs PEDIS/UT; amputation validation vs Saint Elian/UT/Meggitt-Wagner; prospective discrimination vs DUSS/UT). The honest spread is wide and prints in full: single-clinician reliability is only moderate (ICC 0.44 — the system is reliable when several observers' ratings are combined, which is not how it is used at one bedside), its amputation AUROC trailed two comparator systems in Peru, yet it was the only discriminator in the prospective study. NOT counted: PMID 37861669, whose title claims validity and reliability while its abstract (fetched in full) reports no data — recorded on the synthesis card so the title is never mistaken for a fourth report. Populations are diabetic foot ulcer cohorts throughout. A classification-performance shelf, not an ulcer-treatment shelf. Cross-points in prose only: pack #8159 (WIfI), pack #8157 (PUSH), pack #8158 (BWAT).
MeSH: Aged · Debridement/methods · Diabetic Foot*/classification,complications,diagnosis · Female · Humans · Ischemia*/diagnosis,etiology · Male · Outcome Assessment, Health Care/methods · Patient Care Planning · Prognosis · Prospective Studies · Reproducibility of Results · Research Design · Severity of Illness Index · Wound Infection*/diagnosis,etiology · Amputation, Surgical*/statistics & numerical data · Peru/epidemiology · Retrospective Studies · Middle Aged · Diabetic Foot*/surgery,classification,diagnosis · Hospitals, Public · ROC Curve · Diabetes Mellitus, Type 2*/complications
Cards (4)
Card 1 — Inter-observer reliability in a three-system comparison (Forsythe 2016, International Journal of Lower Extremity Wounds — 37 patients classified by a pool of 12 trained observers after debridement): single-observer ICC for SINBAD 0.44 (slight-to-moderate) vs multiple-observer 0.91, with the infection (0.28) and ischaemia (0.26) components the worst single-observer items — SHARED REPORT, printed as shared: its PEDIS and University of Texas limbs are comparators
Study: Reliability study (primary report) — shared report (PEDIS / UT limbs are comparators)
Population: 37 patients (78.4% male) with diabetic foot ulcers, classified after sharp debridement by a multidisciplinary pool of 12 trained observers using the PEDIS, SINBAD and University of Texas (UT) systems; inter-observer reliability was assessed by intraclass correlations for single and multiple observers.
Summary: Inter-observer reliability in a three-system comparison (Forsythe 2016, International Journal of Lower Extremity Wounds — 37 patients classified by a pool of 12 trained observers after debridement): single-observer ICC for SINBAD 0.44 (slight-to-moderate) vs multiple-observer 0.91, with the infection (0.28) and ischaemia (0.26) components the worst single-observer items — SHARED REPORT, printed as shared: its PEDIS and University of Texas limbs are comparators
Result: Single-observer reliability was slight to moderate for all scoring systems (UT 0.53; SINBAD 0.44; PEDIS 0.23–0.42), but multiple-observer reliability was almost perfect (UT 0.94; SINBAD 0.91; PEDIS 0.80–0.90). The worst single-observer agreement was on infection (SINBAD 0.28; PEDIS 0.28), ischaemia (SINBAD 0.26; PEDIS 0.23) and both (UT 0.25), improving to almost perfect for multiple observers (infection 0.83; ischaemia 0.80–0.82; both 0.81). The authors conclude the systems may be reliably used by multiple observers for research and audit, but show only slight-to-moderate reliability for a single observer on an individual subject, as published.
Watch out: The gap between the two ICCs is the finding: SINBAD is reliable when several trained observers' ratings are combined (0.91), which is not how it is used at one bedside, where a single clinician's rating carries ICC 0.44 — and its two most consequential components (infection, ischaemia) are its least reliable singly (0.28 / 0.26). The record's title lists the SINBAD components without 'Area'; the six-component definition on this shelf follows the system's standard form as described in the other anchors. Small N (37 patients) prints on the face.
Source: Forsythe et al. Interobserver Reliability of Three Validated Scoring Systems in the Assessment of Diabetic Foot Ulcers. The international journal of lower extremity wounds. 2016. PMID: 27358037. Registry ID: none in the record. MeSH: Aged · Debridement/methods · Diabetic Foot*/classification,complications,diagnosis · Female · Humans · Ischemia*/diagnosis,etiology · Male · Outcome Assessment, Health Care/methods · Patient Care Planning · Prognosis · Prospective Studies · Reproducibility of Results · Research Design · Severity of Illness Index · Wound Infection*/diagnosis,etiology
Card 2 — Peruvian external validation for major amputation (Gallardo-Alburqueque 2026, PLOS ONE — retrospective cohort of 342 patients at a Peruvian public hospital; 6-month major-amputation incidence 11%): SINBAD AUROC 0.74 with best threshold ≥5, against Saint Elian 0.90 and University of Texas 3D 0.81 in the same patients — SHARED REPORT, printed as shared; SINBAD was the weakest of the four systems in this cohort and prints as such
Study: External validation study (primary report) — shared report (four systems compared; SINBAD limb carded)
Population: 342 patients with type 2 diabetes and a lower-limb ulcer treated at María Auxiliadora Hospital, Lima (a referral centre with a specialised diabetic foot unit), January 2015 to December 2019, all with complete clinical data within 48 hours of the index encounter and at least six months of follow-up; median age 62 years, 67.0% male. Four classifications (Meggitt-Wagner, University of Texas, SINBAD, Saint Elian) were validated against major amputation (above the ankle).
Summary: Peruvian external validation for major amputation (Gallardo-Alburqueque 2026, PLOS ONE — retrospective cohort of 342 patients at a Peruvian public hospital; 6-month major-amputation incidence 11%): SINBAD AUROC 0.74 with best threshold ≥5, against Saint Elian 0.90 and University of Texas 3D 0.81 in the same patients — SHARED REPORT, printed as shared; SINBAD was the weakest of the four systems in this cohort and prints as such
Result: The six-month cumulative incidence of major amputation was 11%. AUROC values were: Saint Elian 0.90; University of Texas (3D stage) 0.81; Meggitt-Wagner 0.81; and SINBAD 0.74. The most discriminative thresholds were Saint Elian ≥18, Texas stage 3D, Meggitt-Wagner ≥3 and SINBAD ≥5. The authors conclude the Saint Elian and University of Texas systems showed the best prognostic accuracy while Meggitt-Wagner and SINBAD performed moderately, as published.
Watch out: SINBAD finished last of the four systems in this cohort (0.74 against 0.90 for the best) — the limb prints unsuppressed, at the weight the record gives it. A retrospective single-hospital validation in a referral population with an 11% amputation incidence: the AUROC and the ≥5 threshold describe that spectrum, and the threshold is a Youden-derived cut-point from this cohort, not a validated action threshold.
Source: Gallardo-Alburqueque et al. External validation of the Meggitt-Wagner, Texas University, SINBAD, and Saint Elian classifications for predicting major amputation in patients with diabetes at a public hospital in Peru. PloS one. 2026. PMID: 41564031. Registry ID: none in the record. MeSH: Humans · Amputation, Surgical*/statistics & numerical data · Peru/epidemiology · Male · Retrospective Studies · Middle Aged · Diabetic Foot*/surgery,classification,diagnosis · Hospitals, Public · Female · Aged · Prognosis · ROC Curve · Diabetes Mellitus, Type 2*/complications
Card 3 — Prospective three-system comparison (Bevinamarad 2026, Cureus — 107 patients followed to definitive outcome: secondary healing 4.7%, skin grafting 78.5%, amputation 16.8%): SINBAD scores differed significantly across outcome groups (medians 5 vs 4 vs 2, p = 0.018) and SINBAD was the only one of the three systems whose scores discriminated the outcomes — DUSS and the University of Texas system did not — SHARED REPORT, printed as shared
Study: Prospective comparison study (primary report) — shared report (DUSS / UT limbs are comparators)
Population: 107 patients aged ≥35 years with diabetic foot ulcers at a tertiary care centre over two years (mean age 56.84 ± 12.32 years; 78.3% male), assessed at baseline with the Diabetic Ulcer Severity Score (DUSS), the University of Texas classification and SINBAD, and followed until a definitive outcome: secondary healing (5 patients, 4.7%), split-thickness skin grafting (84, 78.5%) or lower-limb amputation (18, 16.8%).
Summary: Prospective three-system comparison (Bevinamarad 2026, Cureus — 107 patients followed to definitive outcome: secondary healing 4.7%, skin grafting 78.5%, amputation 16.8%): SINBAD scores differed significantly across outcome groups (medians 5 vs 4 vs 2, p = 0.018) and SINBAD was the only one of the three systems whose scores discriminated the outcomes — DUSS and the University of Texas system did not — SHARED REPORT, printed as shared
Result: DUSS and UT classification did not show statistically significant differences across outcome groups. In contrast, SINBAD scores were significantly higher in the amputation group (median 5, IQR 4–6) than in the skin-grafting group (median 4, IQR 3–5) and the secondary-healing group (median 2, IQR 1–2) (H = 8.02, p = 0.018), demonstrating better discriminatory ability. The authors conclude SINBAD showed superior predictive performance for adverse clinical outcomes among the systems evaluated and may serve as a practical risk-stratification tool, as published. The record carries no MeSH — printed as such on the source line.
Watch out: The outcome groups are very unbalanced (5 secondary healings against 84 grafts and 18 amputations): the median-2 healing limb rests on five patients, and the discrimination claim is a rank test across those groups, not an AUROC — none is printed in the record and none is claimed here. Despite the record's title, it reports no reliability coefficient; the carded content is outcome discrimination only. A single tertiary centre; two of this shelf's three anchors are 2026 publications, so the base is recent and un-replicated beyond these cohorts.
Source: Bevinamarad et al. Reliability and Validation of Three Scoring Systems in the Assessment of Diabetic Foot Ulcers. Cureus. 2026. PMID: 42077760. Registry ID: none in the record. MeSH: none in the record
Card 4 — Synthesis: SINBAD's verified base is three shared primaries and no dedicated validation with data — single-observer reliability only moderate (ICC 0.44), the weakest amputation AUROC of four systems in Peru (0.74), yet the only discriminator in the prospective three-system study — the Norton composition (0 dedicated-with-data + 3 shared primaries), with all three limbs printed and none suppressed
Study: Synthesis
Population: Synthesis of the 3 shared primary reports carded above: 37 patients rated by 12 observers (reliability); 342 Peruvian hospital patients (amputation validation); 107 prospectively followed patients (outcome discrimination). Total documented N = 486 across the three cohorts, never pooled — three different questions (reliability, amputation prediction, outcome discrimination) in three different spectra.
Summary: Synthesis: SINBAD's verified base is three shared primaries and no dedicated validation with data — single-observer reliability only moderate (ICC 0.44), the weakest amputation AUROC of four systems in Peru (0.74), yet the only discriminator in the prospective three-system study — the Norton composition (0 dedicated-with-data + 3 shared primaries), with all three limbs printed and none suppressed
Result: The verified set holds a wide, honest spread: a classification whose single-clinician reliability is slight-to-moderate (0.44) and whose infection and ischaemia components are its least reliable items; an external validation in which its amputation AUROC (0.74, threshold ≥5) trailed Saint Elian (0.90), University of Texas 3D (0.81) and Meggitt-Wagner (0.81); and a prospective study in which it alone of three systems separated outcome groups (p = 0.018). NOT counted: PMID 37861669 (2023, Advances in Skin & Wound Care), titled 'The Validity and Reliability of the SINBAD Classification System' — fetched in full; its abstract is a narrative overview reporting no sample, no coefficient and no validation data, and it is recorded here so the title is never mistaken for a fourth report.
Watch out: Composition discipline (graduated row, Norton precedent): 0 dedicated-with-data reports + 3 shared primaries — every anchor's SINBAD limb sits inside a multi-system comparison, and the comparator limbs (PEDIS, UT, DUSS, Saint Elian, Meggitt-Wagner) are not SINBAD evidence. Lineage: this shelf graduates Slate 31's Audit B15 on the third shared primary (PMID 42077760). Cross-points in prose only: pack #8159 (WIfI — the limb-threat classification, a different system for a different construct), packs #8157 (PUSH) and #8158 (BWAT) — healing/wound-assessment instruments, not classifications.
Source: Synthesis of the reports carded above; no additional source.