EuroSCORE II cardiac-surgery operative-mortality model: derivation in 22,381 patients at 154 hospitals in 43 countries (overall mortality 3.9%; the older models overpredicted — additive 5.8%, logistic 7.57%; EuroSCORE II in its 5,553-patient validation subset was well calibrated, actual 4.18% vs predicted 3.95%, AUC 0.8095); all-cardiac-surgery meta-analysis pools AUC 0.792 (145,592 procedures); valve-only meta-analysis pools AUC 0.70 with observed/expected 1.15 — underprediction, worst in TAVR (1.23), a population outside the derivation

Shelf #8234 · Heart, vessels, blood pressure & clotting

PREDICTIVE PERFORMANCE — good discrimination and calibration in its derivation era for major cardiac surgery overall, with population-dependent decay: derivation in 22,381 patients (overall mortality 3.9%) found the older models overpredicted (additive predicted 5.8%, logistic 7.57% vs actual 3.9%) while EuroSCORE II in its validation subset (5,553 patients) was well calibrated (actual 4.18% vs predicted 3.95%) with AUC 0.8095; the all-cardiac-surgery meta-analysis (22 articles, 145,592 procedures) pools AUC 0.792 with observed mortality 2.95% vs expected 3.30%; the valve-replacement meta-analysis (10 studies, 13,856 patients) pools a lower AUC of 0.70 with observed/expected ratio 1.15 — underprediction, worst in TAVR (1.23; AUC 0.66), a population outside the derivation's intended spectrum. EuroSCORE II is a 2010-era model requiring local recalibration checks, not a fixed constant

Stamped: 2026-11-28.

Evidence published: 2012–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients undergoing major cardiac surgery, how well does EuroSCORE II (the updated European System for Cardiac Operative Risk Evaluation logistic model) predict operative mortality — what calibration and discrimination did its derivation in 22,381 patients find, and what do the validation meta-analyses pool for all cardiac surgery and for aortic valve replacement specifically?

Balance of the evidence

Composition prints on the face: 1 programme derivation (22,381 patients; internal validation subset 5,553) + 2 syntheses whose pools overlap each other and the derivation era (145,592 procedures across 22 articles; 13,856 valve-replacement patients across 10 studies — neither pool is added to the other or to the derivation). The two syntheses disagree BY POPULATION (all cardiac surgery AUC 0.792 vs valve-only 0.70) and print by population, never merged. Calibration drifts with era and case-mix — the derivation itself exists because the original EuroSCORE overpredicted — so every figure prints with its population and era. Cross-point in prose only: pack #7612 (POSSUM / P-POSSUM — general and vascular surgery physiology scores; EuroSCORE II is cardiac-surgery-specific).

MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Calibration · Cardiac Surgical Procedures/adverse effects*,methods,mortality · Databases, Factual · Evidence-Based Medicine/methods · Female · Humans · Male · Middle Aged · Prognosis · Risk Assessment/methods · Risk Factors · Severity of Illness Index* · Terminology as Topic · Young Adult · Area Under Curve · Cardiac Surgical Procedures/adverse effects,mortality* · Decision Support Techniques* · Hospital Mortality* · Predictive Value of Tests · ROC Curve · Risk Assessment · Treatment Outcome · Aortic Valve/surgery · Heart Valve Prosthesis Implantation/mortality* · Hospital Mortality · Reproducibility of Results · Risk Assessment/methods,standards · Severity of Illness Index · Societies, Medical · Surgeons · Transcatheter Aortic Valve Replacement/mortality

Cards (4)

Card 1 — Derivation (Nashef 2012, European Journal of Cardio-Thoracic Surgery — prospective data on 22,381 consecutive patients at 154 hospitals in 43 countries, May–July 2010; overall mortality 3.9%): the older models overpredicted (additive predicted 5.8%, logistic 7.57% vs actual 3.9%); EuroSCORE II in its validation subset (5,553 patients) was well calibrated (actual 4.18% vs predicted 3.95%) with AUC 0.8095 — programme-labelled: the Nashef/EuroSCORE group's own report

Study: Derivation study (primary report) — programme report; internal validation subset

Population: 22,381 consecutive patients undergoing major cardiac surgery in 154 hospitals in 43 countries over a 12-week period (May–July 2010), with prospective risk and outcome data collected via a dedicated website; the dataset was divided into a developmental subset for logistic regression modelling and a validation subset of 5,553 patients for model testing. Compared with the original 1995 EuroSCORE database, mean age was 64.7 (vs 62.5) with 31% females (vs 28%), and more patients had NYHA class IV, extracardiac arteriopathy, and renal and pulmonary dysfunction.

Summary: Derivation (Nashef 2012, European Journal of Cardio-Thoracic Surgery — prospective data on 22,381 consecutive patients at 154 hospitals in 43 countries, May–July 2010; overall mortality 3.9%): the older models overpredicted (additive predicted 5.8%, logistic 7.57% vs actual 3.9%); EuroSCORE II in its validation subset (5,553 patients) was well calibrated (actual 4.18% vs predicted 3.95%) with AUC 0.8095 — programme-labelled: the Nashef/EuroSCORE group's own report

Result: Overall mortality was 3.9% (vs 4.6% in 1995). When applied to the current data, the old risk models overpredicted mortality (actual 3.9%; additive predicted 5.8%; logistic predicted 7.57%). EuroSCORE II was well calibrated on testing in the validation data subset of 5,553 patients (actual mortality 4.18%; predicted 3.95%). Very good discrimination was maintained with an area under the receiver operating characteristic curve of 0.8095, as published.

Watch out: The validation subset is a random split of the same 2010 dataset — internal validation, not external transport; the calibration (4.18% vs 3.95%) describes 2010 practice in participating centres. The derivation's own premise is calibration decay: the original EuroSCORE, well calibrated in 1995, overpredicted by half by 2010 — the same decay should be assumed for EuroSCORE II in later eras until locally rechecked.

Source: Nashef SA et al. EuroSCORE II. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2012. PMID: 22378855. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Calibration · Cardiac Surgical Procedures/adverse effects*,methods,mortality · Databases, Factual · Evidence-Based Medicine/methods · Female · Humans · Male · Middle Aged · Prognosis · Risk Assessment/methods · Risk Factors · Severity of Illness Index* · Terminology as Topic · Young Adult

Card 2 — All-cardiac-surgery meta-analysis (Guida 2014, Journal of Thoracic and Cardiovascular Surgery — 22 articles, 145,592 procedures): operative mortality 2.95% observed vs 3.30% expected (4,293 vs 4,802 events); pooled AUC 0.792 (0.773 to 0.811); observed/expected ratio 1.019 (0.899 to 1.139) — with significant overestimation in isolated CABG (O/E 0.829) and slight underestimation in high-risk patients (O/E 1.253)

Study: Systematic review and meta-analysis (synthesis)

Population: 22 articles reporting performance characteristics of EuroSCORE II for prediction of operative mortality after cardiac surgery (searched in Embase and PubMed, English-only), totalling 145,592 cardiac surgery procedures with 4,293 operative deaths.

Summary: All-cardiac-surgery meta-analysis (Guida 2014, Journal of Thoracic and Cardiovascular Surgery — 22 articles, 145,592 procedures): operative mortality 2.95% observed vs 3.30% expected (4,293 vs 4,802 events); pooled AUC 0.792 (0.773 to 0.811); observed/expected ratio 1.019 (0.899 to 1.139) — with significant overestimation in isolated CABG (O/E 0.829) and slight underestimation in high-risk patients (O/E 1.253)

Result: Meta-analysis provided an area under the ROC curve of 0.792 (95% CI 0.773–0.811), an estimated observed/expected ratio of 1.019 (95% CI 0.899–1.139), and an observed-expected difference of 0.125 (95% CI −0.269 to 0.519). Statistical heterogeneity was detected among retrospective studies including less recent procedures. Subgroup analysis confirmed the robustness of combined estimates for isolated valve procedures and those combined with revascularisation. A significant overestimation by EuroSCORE II (O/E 0.829, 0.677–0.982) was observed in isolated coronary artery bypass grafting, and a slight underestimation in high-risk patients (O/E 1.253; observed-expected difference 1.859), as published.

Watch out: The pooled O/E of 1.019 conceals opposite errors in subgroups — overprediction in isolated CABG (0.829) and underprediction in high-risk patients (1.253) — which is why the subgroup figures print on the card, not just the pool. Heterogeneity among retrospective/less-recent studies is stated by the authors. This pool overlaps the valve-only synthesis carded next; the two are never combined.

Source: Guida P et al. Performance of the European System for Cardiac Operative Risk Evaluation II: a meta-analysis of 22 studies involving 145,592 cardiac surgery procedures. The Journal of thoracic and cardiovascular surgery. 2014. PMID: 25161130. Registry ID: none in the record. MeSH: Area Under Curve · Cardiac Surgical Procedures/adverse effects,mortality* · Decision Support Techniques* · Hospital Mortality* · Humans · Predictive Value of Tests · ROC Curve · Risk Assessment · Risk Factors · Treatment Outcome

Card 3 — Aortic-valve-replacement meta-analysis (Biancari 2014, Journal of Cardiothoracic and Vascular Anesthesia — 10 studies, 13,856 patients undergoing SAVR or TAVR): EuroSCORE II AUC 0.70 overall (0.73 in SAVR, 0.66 in TAVR) with observed/expected ratio 1.15 (0.94 SAVR, 1.23 TAVR) — underprediction in the valve population, worst in TAVR, which was outside the derivation's intended population and prints as a transport

Study: Systematic review and meta-analysis (synthesis) — valve-population restriction

Population: 10 studies validating EuroSCORE II and the Society of Thoracic Surgeons (STS) scores in 13,856 patients who underwent surgical (SAVR) or transcatheter (TAVR) aortic valve replacement at university hospitals; operative mortality was 5.9% overall (SAVR 3.1%; TAVR 9.6%).

Summary: Aortic-valve-replacement meta-analysis (Biancari 2014, Journal of Cardiothoracic and Vascular Anesthesia — 10 studies, 13,856 patients undergoing SAVR or TAVR): EuroSCORE II AUC 0.70 overall (0.73 in SAVR, 0.66 in TAVR) with observed/expected ratio 1.15 (0.94 SAVR, 1.23 TAVR) — underprediction in the valve population, worst in TAVR, which was outside the derivation's intended population and prints as a transport

Result: EuroSCORE II-expected mortality was 5.1% (O/E ratio 1.15; SAVR O/E 0.94; TAVR O/E 1.23) and STS-expected mortality was 6.3% (O/E 0.94). The area under the ROC curve for EuroSCORE II was 0.70 and for STS 0.70 (SAVR: 0.73 for EuroSCORE II and 0.75 for STS; TAVR: 0.66 for EuroSCORE II and 0.63 for STS). EuroSCORE II significantly underestimated mortality risk in TAVR patients (Peto's OR 1.35, p<0.00001) and, to a lesser extent, overestimated it in SAVR patients (Peto's OR 0.86, p = 0.04), as published.

Watch out: TAVR patients were not the derivation's population (a 2010 major-cardiac-surgery cohort), so the TAVR limb (AUC 0.66, O/E 1.23) is a transport failure printed as such, not a defect of the model in its own spectrum — and equally, the derivation's 0.8095 must never be quoted for TAVR. The two 2014 syntheses' pools overlap; this card's 13,856 are a subset population of the broader literature, never added to the 145,592.

Source: Biancari F et al. Meta-analysis on the performance of the EuroSCORE II and the Society of Thoracic Surgeons Scores in patients undergoing aortic valve replacement. Journal of cardiothoracic and vascular anesthesia. 2014. PMID: 25263775. Registry ID: none in the record. MeSH: Aortic Valve/surgery · Heart Valve Prosthesis Implantation/mortality* · Hospital Mortality · Humans · ROC Curve · Reproducibility of Results · Risk Assessment/methods,standards · Severity of Illness Index · Societies, Medical · Surgeons · Transcatheter Aortic Valve Replacement/mortality · Treatment Outcome

Card 4 — Synthesis: EuroSCORE II's verified base is one 2010 programme derivation with internal validation (AUC 0.8095, well calibrated in its own era) plus two overlapping syntheses that fix its transport profile — pooled AUC 0.792 and near-unity overall O/E in all cardiac surgery, decaying to AUC 0.70 with underprediction (O/E 1.15) in valve replacement and worst in TAVR (0.66 / 1.23), a population the model was not derived for. Calibration is era-bound: the model exists because its predecessor's calibration decayed, and its own will too

Study: Synthesis

Population: Synthesis of the 3 reports carded above: derivation 22,381 patients (validation subset 5,553); synthesis pools of 145,592 procedures (22 articles) and 13,856 valve patients (10 studies), overlapping each other and the derivation era — counted as syntheses, never added.

Summary: Synthesis: EuroSCORE II's verified base is one 2010 programme derivation with internal validation (AUC 0.8095, well calibrated in its own era) plus two overlapping syntheses that fix its transport profile — pooled AUC 0.792 and near-unity overall O/E in all cardiac surgery, decaying to AUC 0.70 with underprediction (O/E 1.15) in valve replacement and worst in TAVR (0.66 / 1.23), a population the model was not derived for. Calibration is era-bound: the model exists because its predecessor's calibration decayed, and its own will too

Result: The pattern across the base is discrimination that survives transport (0.81 → 0.79 pooled) better than calibration, which flips sign by subgroup (overprediction in isolated CABG, underprediction in high-risk and TAVR patients). Used as its evidence supports — a 2010-era benchmark for major cardiac surgery with local recalibration — EuroSCORE II performs well; quoted as a fixed constant, or carried into TAVR, the carded evidence itself refutes the figure.

Watch out: Composition discipline: 1 derivation + 2 syntheses is a synthesis-heavy base and prints as such — there is no large independent prospective validation report in the carded set. Cross-point in prose only: pack #7612 (POSSUM / P-POSSUM), the general/vascular operative-risk home; EuroSCORE II is cardiac-specific and the two must not be merged by search.

Source: Synthesis of the reports carded above; no additional source.