SourceMed · Shelf #8254 in the ask interface
Free thyroxine (FT4) and free triiodothyronine (FT3) reference intervals — assay-bound values from five populations: Finnish FT4 9.6–17.1 pmol/L, Chinese age-banded FT4 up to 21.22 pmol/L at 80–100 years, older men's FT4 compressed to 12.1–20.6 pmol/L, and four UK platforms giving 7.9–13.0 to 12.5–19.6 pmol/L on the same subjects
Shelf #8254 · Diabetes, glucose & metabolism
PHYSIOLOGY — ESTABLISHED — FT4/FT3 reference intervals are replicated across five populations, and every interval belongs to its assay: Finnish AutoDELFIA FT4 9.6–17.1 and FT3 4.3–7.5 pmol/L; Chinese Han age bands FT4 10.26–19.25 (19–64 y), 10.04–19.76 (65–79 y) and 9.79–21.22 pmol/L (80–100 y) with FT3 falling and the TSH upper limit rising with age; older Australian men (Roche Elecsys) FT4 compressed to 12.1–20.6 pmol/L (0.94–1.60 ng/dL) with TSH 0.64–5.9 mIU/L; and on the same UK subjects four platforms gave FT4 ranges from 7.9–13.0 (Beckman) to 12.5–19.6 pmol/L (Roche) — no interval prints without its platform, population and age band
Stamped: 2026-11-28.
Evidence published: 1997–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy adults, what are the reference intervals for serum free thyroxine (FT4) and free triiodothyronine (FT3) — how do the Finnish AutoDELFIA intervals, the Nordic NOBIDA intervals, the age-banded intervals in 5,345 Chinese adults and older people, the compressed FT4 interval in older Australian men, and the four-platform UK comparison differ, given that the intervals belong to their assay?
Balance of the evidence
Composition prints on the face: 5 primary reference-interval reports — Finland (AutoDELFIA; N not documented in the record, printed as such), the Nordic NOBIDA material (489 morning samples, Roche Modular E170; its record prints a TSH interval and the antibody-exclusion finding but no FT4 figure, and none is printed from it), 5,345 Chinese Han adults in three age bands, 3,885 Australian men aged 70–89 (411 very healthy subset), and a UK four-platform comparison (303 recruited, 261 analysed) carrying a 55-paper literature review inside the same report. Intervals are never merged across platforms or populations. Cross-points in prose only: TSH reference intervals are homed at packs #7255 and #7511; this pack homes the FT4/FT3 intervals. Physiology pack — no intervention stamp.
MeSH: Adult · Aged · Female · Fluorescence · Humans · Male · Middle Aged · Reagent Kits, Diagnostic* · Reference Values · Thyrotropin/blood* · Thyroxine/blood* · Triiodothyronine/blood* · Adolescent · Chemistry, Clinical/instrumentation*,methods*,standards · Health · Heparin/metabolism · Hospitals · Pregnancy · Thyroid Hormones/blood* · Age Factors · Aged, 80 and over · Asian People/genetics · Biological Assay · China/epidemiology · Ethnicity/genetics · Thyroid Diseases · Thyroid Function Tests/methods · Thyroid Hormones · Thyrotropin/analysis*,blood · Thyroxine/analysis*,blood · Triiodothyronine/analysis*,blood · Hyperthyroidism/blood,diagnosis · Hypothyroidism/blood,diagnosis · Prospective Studies · Thyroid Hormones/standards* · United Kingdom ·
Cards (6)
Card 1 — Finnish AutoDELFIA intervals (Taimela 1997, European Journal of Clinical Chemistry and Clinical Biochemistry — healthy Finnish adults; N not documented in the record): FT4 9.6–17.1 pmol/L, FT3 4.3–7.5 pmol/L, TSH 0.6–4.3 mIU/L
Study: Reference-interval study (primary report; N not documented in the record)
Population: Healthy adults in Finland measured on the AutoDELFIA time-resolved fluorescence immunoautomate; the record's abstract states no sample size — N not documented.
Summary: Finnish AutoDELFIA intervals (Taimela 1997, European Journal of Clinical Chemistry and Clinical Biochemistry — healthy Finnish adults; N not documented in the record): FT4 9.6–17.1 pmol/L, FT3 4.3–7.5 pmol/L, TSH 0.6–4.3 mIU/L
Result: Reference intervals: thyrotropin (TSH) 0.6–4.3 mIU/L, free thyroxine (FT4) 9.6–17.1 pmol/L, free triiodothyronine (FT3) 4.3–7.5 pmol/L. This was the first report of reference values in thyroidology using this automatic time-resolved fluorescence system.
Watch out: Assay-bound: these intervals belong to the AutoDELFIA platform and a 1997 Finnish population; they do not transfer to modern analysers. N not documented prints because the record states none.
Source: Taimela E et al. Reference intervals for serum thyrotropin, free thyroxine and free triiodothyronine in healthy adults in Finland, measured by an immunoautomate based on time-resolved fluorescence (AutoDELFIA). European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies. 1997. PMID: 9426351. Registry ID: none in the record. MeSH: Adult · Aged · Female · Fluorescence · Humans · Male · Middle Aged · Reagent Kits, Diagnostic* · Reference Values · Thyrotropin/blood* · Thyroxine/blood* · Triiodothyronine/blood*
Card 2 — Nordic NOBIDA intervals (Friis-Hansen 2008, Clinical Chemistry and Laboratory Medicine — 489 morning samples, Roche Modular E170): after antibody exclusion TSH 0.64–4.7 mIU/L; thyroid-hormone intervals showed only minor sex/country differences — no FT4 figure in the record
Study: Reference-interval study (primary report; FT4 limb coefficient-free in the record)
Population: 489 morning heparinised-plasma samples from healthy unmedicated Nordic adults (NOBIDA reference material), measured on Roche Modular E170 (TSH and thyroid hormones) and Brahms Kryptor (TPO antibodies).
Summary: Nordic NOBIDA intervals (Friis-Hansen 2008, Clinical Chemistry and Laboratory Medicine — 489 morning samples, Roche Modular E170): after antibody exclusion TSH 0.64–4.7 mIU/L; thyroid-hormone intervals showed only minor sex/country differences — no FT4 figure in the record
Result: After exclusion of TPO-antibody- and thyroglobulin-antibody-positive individuals, the TSH reference interval was 0.64 (0.61–0.72) to 4.7 (4.4–5.0) mIU/L, and the exclusion minimised sex and country differences in TSH. For the thyroid hormones there were only minor differences between Nordic populations and between men and women, and the intervals were unaffected by removal of antibody-positive samples. The record prints no FT4 interval figure, and none is printed from this card.
Watch out: Morning sampling and the Roche platform both push the TSH upper limit up (the authors say so) — 4.7 mIU/L is a property of this sampling and assay, not a universal ceiling. Heparinised plasma, not serum.
Source: Friis-Hansen L et al. Reference intervals for thyreotropin and thyroid hormones for healthy adults based on the NOBIDA material and determined using a Modular E170. Clinical chemistry and laboratory medicine. 2008. PMID: 18681828. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Chemistry, Clinical/instrumentation*,methods*,standards · Female · Health · Heparin/metabolism · Hospitals · Humans · Male · Middle Aged · Pregnancy · Reference Values · Thyroid Hormones/blood* · Thyrotropin/blood*
Card 3 — Chinese age-banded intervals (Xiong 2020, PLoS One — 5,345 healthy Chinese Han adults): FT4 10.26–19.25 pmol/L (19–64 y), 10.04–19.76 (65–79 y), 9.79–21.22 (80–100 y); FT3 falls and TSH upper limit rises with age (4.81 → 5.51 → 6.28 µIU/mL)
Study: Reference-interval study (primary report, age-banded)
Population: 5,345 healthy Chinese Han individuals in three age bands: 4,297 aged 19–64 years, 719 aged 65–79 years, 329 aged 80–100 years, measured on a fully automated analyser.
Summary: Chinese age-banded intervals (Xiong 2020, PLoS One — 5,345 healthy Chinese Han adults): FT4 10.26–19.25 pmol/L (19–64 y), 10.04–19.76 (65–79 y), 9.79–21.22 (80–100 y); FT3 falls and TSH upper limit rises with age (4.81 → 5.51 → 6.28 µIU/mL)
Result: Reference intervals by band — ages 19–64: FT3 3.40–6.44, FT4 10.26–19.25 pmol/L, TSH 0.50–4.81 µIU/mL; ages 65–79: FT3 3.01–5.91, FT4 10.04–19.76 pmol/L, TSH 0.54–5.51 µIU/mL; ages 80–100: FT3 2.82–5.57, FT4 9.79–21.22 pmol/L, TSH 0.31–6.28 µIU/mL. FT3 was lower and FT4 and TSH higher at age ≥65 than under 65.
Watch out: The oldest band (80–100 years) rests on 329 people and its FT4 upper limit (21.22 pmol/L) is the widest here — age-band intervals print by band and population, never as one adult range.
Source: Xiong J et al. Study of reference intervals for free triiodothyronine, free thyroxine, and thyroid-stimulating hormone in an elderly Chinese Han population. PloS one. 2020. PMID: 32970739. Registry ID: none in the record. MeSH: Adult · Age Factors · Aged · Aged, 80 and over · Asian People/genetics · Biological Assay · China/epidemiology · Ethnicity/genetics · Female · Humans · Male · Middle Aged · Reference Values · Thyroid Diseases · Thyroid Function Tests/methods · Thyroid Hormones · Thyrotropin/analysis*,blood · Thyroxine/analysis*,blood · Triiodothyronine/analysis*,blood
Card 4 — Older Australian men (Yeap 2017, Journals of Gerontology Series A — Health In Men Study, 3,885 men aged 70–89, Roche Elecsys): FT4 12.1–20.6 pmol/L (0.94–1.60 ng/dL) — compressed against the conventional 10–23 pmol/L; TSH 0.64–5.9 mIU/L; healthy-men intervals reclassified 8.0%
Study: Reference-interval study (primary report, older men only)
Population: 3,885 community-dwelling men aged 70–89 years; the 411 very healthy men (excellent/very good self-rated health, no major comorbidity) formed the strict reference subset.
Summary: Older Australian men (Yeap 2017, Journals of Gerontology Series A — Health In Men Study, 3,885 men aged 70–89, Roche Elecsys): FT4 12.1–20.6 pmol/L (0.94–1.60 ng/dL) — compressed against the conventional 10–23 pmol/L; TSH 0.64–5.9 mIU/L; healthy-men intervals reclassified 8.0%
Result: Whole-cohort 2.5th–97.5th centiles: TSH 0.64–5.9 mIU/L, FT4 12.1–20.6 pmol/L (0.94–1.60 ng/dL). In the 411 very healthy men: TSH 0.67–4.98 mIU/L, FT4 12.1–20.5 pmol/L (0.94–1.59 ng/dL). Against the conventional intervals (TSH 0.4–4.0 mIU/L, FT4 10–23 pmol/L) the older-men FT4 interval is compressed and the TSH interval shifted up. Applying the very-healthy-men intervals to the whole cohort reclassified 310 men (8.0%). Higher FT4 was associated with increased mortality; TSH was not.
Watch out: Men only, aged 70–89, one platform — the compressed FT4 interval must not be applied to women or younger adults. The mortality association is observational and prints as an association.
Source: Yeap BB et al. Reference Ranges for Thyroid-Stimulating Hormone and Free Thyroxine in Older Men: Results From the Health In Men Study. The journals of gerontology. Series A, Biological sciences and medical sciences. 2017. PMID: 27440910. Registry ID: none in the record. MeSH: Aged · Aged, 80 and over · Humans · Hyperthyroidism/blood,diagnosis · Hypothyroidism/blood,diagnosis · Male · Prospective Studies · Reference Values · Thyrotropin/blood* · Thyroxine/blood*
Card 5 — Four-platform UK comparison (Barth 2018, Annals of Clinical Biochemistry — 303 recruited, 261 analysed): FT4 central 95% ranges Abbott 10.6–15.5, Beckman 7.9–13.0, Roche 12.5–19.6, Siemens 11.8–19.0 pmol/L on the same subjects
Study: Reference-interval comparison study with systematic review (typed Systematic Review at PubMed; primary four-platform data counted on substance)
Population: 303 healthy UK adults recruited prospectively, 261 analysed after exclusions (age >65 and TPO-antibody positivity excluded); FT4 and TSH measured on four platforms in the same subjects, plus a systematic review of 55 published interval studies.
Summary: Four-platform UK comparison (Barth 2018, Annals of Clinical Biochemistry — 303 recruited, 261 analysed): FT4 central 95% ranges Abbott 10.6–15.5, Beckman 7.9–13.0, Roche 12.5–19.6, Siemens 11.8–19.0 pmol/L on the same subjects
Result: FT4 central 95% ranges: Abbott Architect 10.6–15.5, Beckman Unicel DxI 7.9–13.0, Roche Cobas 12.5–19.6, Siemens Advia Centaur XP 11.8–19.0 pmol/L. TSH ranges: Abbott 0.51–3.67, Beckman 0.57–3.60, Roche 0.60–4.31, Siemens 0.63–4.29 mIU/L. In the 55-paper literature review, method differences were significant for thyroxine but not for TSH. The authors conclude there is an urgent need for assay standardisation and that guidelines must reflect method-related differences until then.
Watch out: This card is the pack's headline: a Beckman FT4 of 13 pmol/L sits above its own range and mid-range on Roche — the same blood, four different 'normal' intervals. Intervals from different platforms must never be interchanged.
Source: Barth JH et al. Comparison of method-related reference intervals for thyroid hormones: studies from a prospective reference population and a literature review. Annals of clinical biochemistry. 2018. PMID: 28081637. Registry ID: none in the record. MeSH: Adult · Female · Humans · Male · Prospective Studies · Reference Values · Thyroid Hormones/standards* · United Kingdom
Card 6 — Synthesis — FT4/FT3 reference intervals are established physiology, but every interval belongs to its assay, its population and its age band
Study: Synthesis
Population: 5 reports carded: Finnish adults (N not documented in the record) + 489 Nordic samples + 5,345 Chinese adults + 3,885 older Australian men + 261 analysed UK adults (plus a 55-paper review inside the UK report, counted as part of that report).
Summary: Synthesis — FT4/FT3 reference intervals are established physiology, but every interval belongs to its assay, its population and its age band
Result: FT4 intervals cluster around a lower limit of ~10–12 pmol/L and an upper limit of ~17–21 pmol/L, but the spread is method-made: on the same UK subjects the four platforms gave 7.9–13.0 (Beckman) to 12.5–19.6 pmol/L (Roche). FT3 falls with age in the Chinese bands (upper limit 6.44 → 5.91 → 5.57 pmol/L) while the TSH upper limit rises (4.81 → 5.51 → 6.28 µIU/mL); in older men the FT4 interval compresses (12.1–20.6 pmol/L) and TSH shifts up (to 5.9 mIU/L). Stamp justification: PHYSIOLOGY — ESTABLISHED — the values are replicated across five populations, with the assay-binding printed as part of the physiology, not as a footnote.
Watch out: Cross-points in prose only: TSH-only reference intervals are homed at packs #7255 and #7511 — this pack's question is the FT4/FT3 intervals those shelves do not give, and their TSH limbs are not re-carded here. No interval on this pack may be printed without its platform.
Source: Synthesis of the reports carded above; no additional source.