SourceMed · Shelf #8272 in the ask interface
SES-CD (Simple Endoscopic Score for Crohn's Disease) — development found interobserver kappa 0.791–1.000 across variables and correlation with the CDEIS of r = 0.920 in prospective validation; independent parallel scoring found SES-CD vs CDEIS Spearman r = 0.938 but only r = 0.473 against the CDAI and r = 0.525 against CRP; central readers showed intra-rater ICC 0.91 and inter-rater ICC 0.83
Shelf #8272 · Liver & gut
MEASUREMENT PROPERTIES — convergence with the incumbent CDEIS is strong, convergence with clinical activity and CRP is only moderate, and both limbs print: the programme development (reproducibility in 71 paired examinations, derivation in 70 patients, prospective validation in 121 different patients) found interobserver kappa 0.791–1.000 across the four variables and SES-CD correlation with the CDEIS of r = 0.920; independent prospective parallel scoring (86 patients, plus 32 with follow-up endoscopy) found SES-CD vs CDEIS Spearman r = 0.938, but SES-CD vs CDAI r = 0.473 and vs CRP r = 0.525, and change in endoscopic scores correlated between indices (r = 0.828) while failing to correlate with change in CDAI or CRP; central readers reviewing videos from 50 trial patients in triplicate showed SES-CD intra-rater ICC 0.91 (0.89–0.95) and inter-rater ICC 0.83 (0.75–0.88), with CDEIS–SES-CD correlation 0.92 — the validity evidence is agreement with the older CDEIS, not with an independent standard of mucosal disease, and responsiveness was expressly undetermined in the central-reader report
Stamped: 2026-11-28.
Evidence published: 2004–2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the SES-CD (Simple Endoscopic Score for Crohn's Disease — four endoscopic variables — ulcer size, ulcerated surface, affected surface, stenosis — each scored 0–3 across bowel segments) — what did its development establish against the CDEIS, how did it compare head-to-head in prospective parallel scoring, and how reliable is it among central readers?
Balance of the evidence
Composition: 3 reports — 1 programme derivation/prospective validation (the Daperno/D'Haens group's own report), 1 independent prospective parallel-scoring study, and 1 central-reader reliability study on video recordings from a biological-therapy induction trial (registry NCT01466374 in the record; TYPE-FLAG: typed Randomized Controlled Trial at PubMed although the carded content is a reliability study on recordings from that trial). The SEAS-CD enterographic score is a different, MRE-based instrument that uses SES-CD as its reference — it is not a SES-CD report and is counted nowhere.
MeSH: Adult · C-Reactive Protein/analysis · Crohn Disease/pathology* · Endoscopy, Gastrointestinal* · Female · Humans · Intestinal Mucosa/pathology · Male · Observer Variation · Prospective Studies · Reproducibility of Results · Severity of Illness Index · Ulcer/pathology · Aged · C-Reactive Protein/metabolism · Crohn Disease/metabolism,pathology* · Cross-Sectional Studies · Follow-Up Studies · Middle Aged · Prognosis · Young Adult · Consensus · Constriction, Pathologic/diagnostic imaging,etiology · Crohn Disease/complications,diagnostic imaging*,drug therapy · Severity of Illness Index* · Ulcer/diagnostic imaging,etiology · Video Recording
Cards (4)
Card 1 — Development and prospective validation (Daperno 2004, Gastrointestinal Endoscopy — programme report, the Daperno/D'Haens group's own): scoring reproducibility in 71 paired examinations (interobserver kappa 0.791–1.000 across variables), score derived in 70 patients and prospectively validated in 121 different patients, correlating with the CDEIS at r = 0.920
Study: Development and validation study (primary report; programme report — the Daperno/D'Haens group's own)
Population: Patients with Crohn's disease: reproducibility of the selected endoscopic parameters (ulcer size, ulcerated and affected surfaces, stenosis, each scored 0 to 3) was evaluated through 71 examinations in which the endoscopist was paired with an observer; the simplest score highly correlated with both the Crohn's Disease Endoscopic Index of Severity (CDEIS) and the Crohn's Disease Activity Index was derived for 70 patients and then prospectively validated in 121 different patients.
Summary: Development and prospective validation (Daperno 2004, Gastrointestinal Endoscopy — programme report, the Daperno/D'Haens group's own): scoring reproducibility in 71 paired examinations (interobserver kappa 0.791–1.000 across variables), score derived in 70 patients and prospectively validated in 121 different patients, correlating with the CDEIS at r = 0.920
Result: The interobserver agreement for all selected endoscopic variables was excellent (kappa coefficient 0.791–1.000). Based on multiple linear regression, the SES-CD resulted in the sum of the scores for ulcer size, ulcerated surface, affected surface and luminal narrowing. In the validation phase, a strong correlation was demonstrated between the SES-CD and the CDEIS (r = 0.920). In addition, the SES-CD was correlated to clinical parameters and serum C-reactive protein level (the record's abstract prints no coefficient for those limbs, and none is printed here). The authors conclude the SES-CD is a simple, reproducible and easy-to-use endoscopic scoring system for Crohn's disease.
Watch out: The derivation target was correlation with the CDEIS itself — the score was built to reproduce the incumbent, so r = 0.920 is agreement with the instrument it simplifies, not validation against an independent standard of mucosal disease. The clinical-parameter and CRP limbs are asserted without coefficients in the record and carry no figures here.
Source: Daperno et al. Development and validation of a new, simplified endoscopic activity score for Crohn's disease: the SES-CD. Gastrointestinal endoscopy. 2004. PMID: 15472670. Registry ID: none in the record. MeSH: Adult · C-Reactive Protein/analysis · Crohn Disease/pathology* · Endoscopy, Gastrointestinal* · Female · Humans · Intestinal Mucosa/pathology · Male · Observer Variation · Prospective Studies · Reproducibility of Results · Severity of Illness Index · Ulcer/pathology
Card 2 — Prospective parallel scoring (Sipponen 2010, Inflammatory Bowel Diseases — independent study, 86 Crohn's patients scored with both indices at ileocolonoscopy plus 32 with follow-up endoscopy after therapy): SES-CD vs CDEIS Spearman r = 0.938, but SES-CD vs CDAI r = 0.473 and vs CRP r = 0.525; change in endoscopic scores correlated between indices (r = 0.828) while failing to correlate with change in CDAI or CRP
Study: Prospective comparative study (primary report, independent)
Population: 86 Crohn's disease patients, referred for ileocolonoscopy in a cross-sectional study, each endoscopy followed immediately by scoring with both the CDEIS and the SES-CD; after Crohn's therapy, a further 32 patients underwent follow-up endoscopy with both scorings. Serum C-reactive protein (CRP) was measured, and clinical activity was assessed using CDAI (the Crohn's Disease Activity Index).
Summary: Prospective parallel scoring (Sipponen 2010, Inflammatory Bowel Diseases — independent study, 86 Crohn's patients scored with both indices at ileocolonoscopy plus 32 with follow-up endoscopy after therapy): SES-CD vs CDEIS Spearman r = 0.938, but SES-CD vs CDAI r = 0.473 and vs CRP r = 0.525; change in endoscopic scores correlated between indices (r = 0.828) while failing to correlate with change in CDAI or CRP
Result: The CDEIS correlated significantly with the SES-CD (Spearman's r = 0.938, P < 0.0001). Correlations of the SES-CD with the CDAI, at r = 0.473, or CRP, at r = 0.525 (both P < 0.0001), were weaker. From inactive to severe, SES-CD grading correlated significantly with CDEIS grading (r = 0.859, P < 0.0001). Endoscopy score changes, baseline to follow-up, correlated significantly: r = 0.828 for delta-CDEIS against delta-SES-CD (P < 0.001), but did not correlate with delta-CDAI or delta-CRP (all P > 0.05). Both validated endoscopic scores and their changes, the authors conclude, demonstrated a close correlation, and for scoring endoscopic activity in clinical routine the SES-CD could replace the CDEIS.
Watch out: The weak limbs print at full weight beside the headline: an endoscopic score that tracks the CDEIS at 0.938 tracks symptoms (CDAI 0.473) and CRP (0.525) only moderately, and its change does not track change in either — endoscopic activity and clinical activity are different constructs on this evidence, and neither may be read off the other.
Source: Sipponen et al. Endoscopic evaluation of Crohn's disease activity: comparison of the CDEIS and the SES-CD. Inflammatory bowel diseases. 2010. PMID: 20848462. Registry ID: none in the record. MeSH: Adult · Aged · C-Reactive Protein/metabolism · Crohn Disease/metabolism,pathology* · Cross-Sectional Studies · Endoscopy, Gastrointestinal* · Female · Follow-Up Studies · Humans · Male · Middle Aged · Prognosis · Prospective Studies · Severity of Illness Index · Young Adult
Card 3 — Central-reader reliability (Khanna 2016, Gut — video recordings from 50 trial patients reviewed in triplicate by four central readers; TYPE-FLAG: typed Randomized Controlled Trial at PubMed although the carded content is a reliability study on recordings from an induction trial; registry NCT01466374 in the record): SES-CD intra-rater ICC 0.91 (0.89–0.95), inter-rater ICC 0.83 (0.75–0.88), standard error of measurement 2.42 (intra) and 3.07 (inter); CDEIS–SES-CD correlation 0.92
Study: Central-reader reliability study (primary report) — TYPE-FLAG: PubMed types it as a Randomized Controlled Trial; counted on substance as a reliability study on trial recordings
Population: Video recordings of colonoscopies obtained from 50 patients with Crohn's disease who participated in an induction trial of a biological therapy, triplicated and reviewed in random order by four central readers; intra-rater and inter-rater reliability assessed for the CDEIS, the SES-CD and a global evaluation of lesion severity (GELS), followed by a consensus process identifying common sources of disagreement.
Summary: Central-reader reliability (Khanna 2016, Gut — video recordings from 50 trial patients reviewed in triplicate by four central readers; TYPE-FLAG: typed Randomized Controlled Trial at PubMed although the carded content is a reliability study on recordings from an induction trial; registry NCT01466374 in the record): SES-CD intra-rater ICC 0.91 (0.89–0.95), inter-rater ICC 0.83 (0.75–0.88), standard error of measurement 2.42 (intra) and 3.07 (inter); CDEIS–SES-CD correlation 0.92
Result: Intraclass correlation coefficients (ICCs) for intra-rater reliability for CDEIS, SES-CD and GELS were 0.89 (0.86 to 0.93), 0.91 (0.89 to 0.95) and 0.81 (0.77 to 0.89) respectively, with standard error of measurement (SEM) of 2.10, 2.42 and 1.15. The corresponding ICCs for inter-rater reliability were 0.71 (0.63 to 0.76), 0.83 (0.75 to 0.88) and 0.62 (0.52 to 0.70), with SEM of 3.42, 3.07 and 1.63. Correlation between CDEIS and GELS was 0.75, between SES-CD and GELS 0.74 and between CDEIS and SES-CD 0.92. The most common sources of disagreement were interpretation of superficial ulceration, definition of disease site at the ileocolonic anastomosis, assessment of anorectal lesions and grading severity of stenosis. The authors characterise central reading of both indices as having 'substantial' to 'almost perfect' reliability, while stating the responsiveness of these instruments is yet to be determined.
Watch out: Reliability among four trained central readers reviewing recordings is not reliability among routine endoscopists, and the inter-rater SEM of 3.07 points is material on this scale. Responsiveness was expressly undetermined in this report — reliability here must not be read as sensitivity to treatment change.
Source: Khanna et al. Reliability among central readers in the evaluation of endoscopic findings from patients with Crohn's disease. Gut. 2016. PMID: 25935574. Registry ID: ClinicalTrials.gov:NCT01466374. MeSH: Adult · Consensus · Constriction, Pathologic/diagnostic imaging,etiology · Crohn Disease/complications,diagnostic imaging*,drug therapy · Endoscopy, Gastrointestinal* · Female · Humans · Male · Middle Aged · Observer Variation · Reproducibility of Results · Severity of Illness Index* · Ulcer/diagnostic imaging,etiology · Video Recording · Young Adult
Card 4 — Synthesis — SES-CD reproduces the CDEIS reliably (r ≈0.92–0.94, central-reader ICCs 0.83–0.91) and tracks clinical activity and CRP only moderately (0.47–0.53); that is the whole validity claim
Study: Synthesis
Population: Composition restated: 3 reports — 1 programme derivation/validation (71 paired examinations; derivation 70 + validation 121 patients, phases of one programme study), 1 independent parallel-scoring study (86 + 32 patients) and 1 central-reader reliability study (recordings from 50 trial patients, NCT01466374). Phase and sample Ns are different counting units and are never added into a single cohort total.
Summary: Synthesis — SES-CD reproduces the CDEIS reliably (r ≈0.92–0.94, central-reader ICCs 0.83–0.91) and tracks clinical activity and CRP only moderately (0.47–0.53); that is the whole validity claim
Result: Two independent comparative limbs converge on the same convergence figure (SES-CD vs CDEIS r = 0.920 at derivation-validation and Spearman 0.938 in parallel scoring; 0.92 again among central readers), and reliability is good to excellent at every level tested (variable kappas 0.791–1.000; intra-rater ICC 0.91; inter-rater ICC 0.83). The counterweight prints at the same weight: correlations with the CDAI (0.473) and CRP (0.525) are moderate, and change in SES-CD did not correlate with change in either. No report was refused from this row's anchor set; the SEAS-CD enterographic instrument was excluded at mining as a different instrument. Stamp justification: MEASUREMENT PROPERTIES stated as convergence-with-incumbent plus reliability, with the moderate clinical/biomarker limbs and the undetermined responsiveness in the stamp sentence.
Watch out: The SES-CD's evidence is agreement with the older CDEIS — there is no independent standard of mucosal disease in any card, so a high SES-CD–CDEIS correlation cannot show either score measures true disease activity.
Source: Synthesis of the reports carded above; no additional source.