SourceMed · Shelf #8277 in the ask interface

GerdQ (six-item self-assessment questionnaire for gastro-oesophageal reflux disease) — diagnostic performance is modest in every report: sensitivity 65% and specificity 71% at development, sensitivity 66% / specificity 64% with negative predictive value only 22% in the Norwegian validation, and sensitivity 57.7% / specificity 48.9% in the Chinese study, whose authors concluded GerdQ alone cannot accurately diagnose GERD

Shelf #8277 · Liver & gut

MEASUREMENT PROPERTIES — a triage aid, not a diagnostic confirmation: across three reports the GerdQ performs at sensitivity about 58–66% and specificity about 49–71% — development (over 300 primary-care patients) sensitivity 65% and specificity 71%, similar to gastroenterologists' assessment; the Norwegian validation (169 patients, 81% reflux-oesophagitis prevalence) at cut-off ≥9 found sensitivity 66% (58 to 74) and specificity 64% (41 to 83), positive predictive value 92% (86 to 97) but negative predictive value only 22% (13 to 34); the Chinese study (636 patients) found sensitivity 57.7% and specificity 48.9% and concluded GerdQ alone cannot accurately diagnose GERD in that population — a negative GerdQ rules almost nothing out, and no card presents a GerdQ threshold as diagnostic confirmation

Stamped: 2026-11-28.

Evidence published: 2009–2014.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the diagnostic properties of the GerdQ (six-item self-assessment questionnaire for gastro-oesophageal reflux disease, built for primary care from the RDQ, GSRS and GIS item pools) — what accuracy did its development establish, and what sensitivity, specificity and predictive values did the Norwegian endoscopy/pH validation and the Chinese impedance study find?

Balance of the evidence

Composition prints on the face: 3 reports — the Dent/Jones group's own development (programme report; items drawn from the RDQ, GSRS and GIS pools), one independent endoscopy/pH validation (169 patients), and one Chinese diagnostic-accuracy study (636 patients, 352 with GERD; typed Clinical Trial at PubMed although the carded content is a diagnostic-accuracy comparison — TYPE-FLAG, counted on substance). Predictive values are prevalence-bound and print with the prevalence that produced them. Distinct from the GSRS, one of GerdQ's parent item pools, and from the RDQ — cross-points in prose only.

MeSH: Adult · Aged · Aged, 80 and over · Female · Gastroesophageal Reflux/diagnosis*,therapy · Humans · Male · Middle Aged · Primary Health Care · Research Design · Surveys and Questionnaires/standards* · Endoscopy/methods · Gastroesophageal Reflux/diagnosis*,drug therapy,psychology · Hydrogen-Ion Concentration · Severity of Illness Index* · Anti-Ulcer Agents/therapeutic use · Asian People · Biopsy · Electric Impedance · Endoscopes, Gastrointestinal/standards* · Esomeprazole/therapeutic use* · Esophageal pH Monitoring/standards* · Esophagus/pathology · Gastroesophageal Reflux/drug therapy*,pathology* · Mucous Membrane/pathology · Reproducibility of Results · Sensitivity and Specificity

Cards (4)

Card 1 — Development (Jones 2009, Alimentary Pharmacology & Therapeutics — over 300 primary-care patients; programme report): at the chosen threshold, sensitivity 65% and specificity 71% for GERD, similar to gastroenterologists' assessment

Study: Instrument development study (primary report; programme report)

Population: Over 300 primary-care patients in the analyses, with items selected from previously validated instruments (RDQ, GSRS and GIS) whose content validity and psychometric properties were documented, piloted in patient focus groups and moderated by qualitative interviews.

Summary: Development (Jones 2009, Alimentary Pharmacology & Therapeutics — over 300 primary-care patients; programme report): at the chosen threshold, sensitivity 65% and specificity 71% for GERD, similar to gastroenterologists' assessment

Result: ROC analysis indicated a sensitivity for GerdQ of 65% and a specificity of 71% for the diagnosis of GERD, similar to that achieved by gastroenterologists. The six-item tool was created as a diagnostic and management aid for primary care without initial specialist referral or endoscopy.

Watch out: 'Similar to gastroenterologists' is a comparison against clinical impression, not against endoscopy/pH reference standards — the development's accuracy figures are the optimistic end of this pack's range, and the programme is an industry-linked instrument programme.

Source: Jones R et al. Development of the GerdQ, a tool for the diagnosis and management of gastro-oesophageal reflux disease in primary care. Alimentary pharmacology & therapeutics. 2009. PMID: 19737151. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Gastroesophageal Reflux/diagnosis*,therapy · Humans · Male · Middle Aged · Primary Health Care · Research Design · Surveys and Questionnaires/standards*

Card 2 — Independent validation (Jonasson 2013, Alimentary Pharmacology & Therapeutics — 169 patients, endoscopy and pH-metry): cut-off ≥9 — sensitivity 66%, specificity 64%, PPV 92% but NPV only 22%

Study: Validation study — diagnostic accuracy

Population: 169 patients with symptoms suggestive of GERD without alarm features, undergoing upper endoscopy and, if normal, pH-metry, followed for 4 weeks with GerdQ completed blinded to the investigator at both visits; reflux oesophagitis or pathological acid exposure was the diagnostic reference, in a sample with 81% reflux-oesophagitis prevalence.

Summary: Independent validation (Jonasson 2013, Alimentary Pharmacology & Therapeutics — 169 patients, endoscopy and pH-metry): cut-off ≥9 — sensitivity 66%, specificity 64%, PPV 92% but NPV only 22%

Result: At cut-off ≥9, sensitivity was 66% (95% CI 58 to 74) and specificity 64% (95% CI 41 to 83). The high prevalence produced a positive predictive value of 92% (95% CI 86 to 97) but a negative predictive value of only 22% (95% CI 13 to 34). Symptom resolution on PPI therapy had sensitivity 76% (95% CI 66 to 84) but specificity 33% (95% CI 17 to 53) for GERD, and did not predict GERD.

Watch out: The NPV limb prints at full weight: in this high-prevalence sample a negative GerdQ was wrong far more often than right, and predictive values move with prevalence — the 92% PPV must never be quoted without the 81% prevalence that produced it. The specificity interval (41 to 83) is wide because non-GERD patients were few.

Source: Jonasson C et al. Validation of the GerdQ questionnaire for the diagnosis of gastro-oesophageal reflux disease. Alimentary pharmacology & therapeutics. 2013. PMID: 23289763. Registry ID: none in the record. MeSH: Adult · Endoscopy/methods · Female · Gastroesophageal Reflux/diagnosis*,drug therapy,psychology · Humans · Hydrogen-Ion Concentration · Male · Middle Aged · Severity of Illness Index* · Surveys and Questionnaires/standards*

Card 3 — Chinese accuracy study (Zhou 2014, Journal of Digestive Diseases — 636 patients, 352 with GERD; TYPE-FLAG: typed Clinical Trial): GerdQ sensitivity 57.7% and specificity 48.9%; authors concluded GerdQ alone cannot accurately diagnose GERD in this population

Study: Diagnostic accuracy study — TYPE-FLAG: typed Clinical Trial at PubMed, counted on substance

Population: 636 patients with symptoms suspected of GERD undergoing endoscopy, 24-hour impedance-pH monitoring and biopsy intercellular-space measurement, with a 2-week esomeprazole test; 352 had GERD.

Summary: Chinese accuracy study (Zhou 2014, Journal of Digestive Diseases — 636 patients, 352 with GERD; TYPE-FLAG: typed Clinical Trial): GerdQ sensitivity 57.7% and specificity 48.9%; authors concluded GerdQ alone cannot accurately diagnose GERD in this population

Result: GerdQ sensitivity and specificity for diagnosing GERD were 57.7% and 48.9%. Impedance monitoring alone was 66.4% / 43.3%, rising to 93.7% sensitivity combined with pH monitoring. Dilated intercellular spaces (≥0.9 μm) were 61.2% / 56.1% and the PPI test 70.5% / 44.4%. The authors concluded that GerdQ score or PPI test alone cannot accurately diagnose GERD in a Chinese population suspected of GERD, and that definitive diagnosis still depends on endoscopy or 24-hour pH monitoring.

Watch out: The negative limb prints at full weight: this is the largest accuracy sample in the pack and the weakest GerdQ performance. A questionnaire developed in European primary care transported to a Chinese suspected-GERD population at near-chance specificity (48.9%).

Source: Zhou LY et al. Accuracy of diagnosing gastroesophageal reflux disease by GerdQ, esophageal impedance monitoring and histology. Journal of digestive diseases. 2014. PMID: 24528678. Registry ID: none in the record. MeSH: Adult · Anti-Ulcer Agents/therapeutic use · Asian People · Biopsy · Electric Impedance · Endoscopes, Gastrointestinal/standards* · Esomeprazole/therapeutic use* · Esophageal pH Monitoring/standards* · Esophagus/pathology · Female · Gastroesophageal Reflux/drug therapy*,pathology* · Humans · Male · Middle Aged · Mucous Membrane/pathology · Reproducibility of Results · Sensitivity and Specificity · Surveys and Questionnaires/standards*

Card 4 — Synthesis: modest accuracy everywhere, weakest where independently tested — 3 reports (1 programme development, 2 independent accuracy studies)

Study: Synthesis

Population: Over 300 primary-care patients (development), 169 validation patients and 636 accuracy-study patients — reported per study, never pooled into a combined sensitivity or specificity the sources do not print.

Summary: Synthesis: modest accuracy everywhere, weakest where independently tested — 3 reports (1 programme development, 2 independent accuracy studies)

Result: Sensitivity runs 57.7–66% and specificity 48.9–71% across the base, falling as the reference standard hardens and the setting moves away from the development population. The Norwegian NPV of 22% (at 81% prevalence) and the Chinese authors' 'cannot accurately diagnose' conclusion are the pack's honest headline beside the development's 65%/71%. No report was refused on this row. The stamp is MEASUREMENT PROPERTIES framed as triage, because that is the strongest claim the three records jointly support.

Watch out: GerdQ was designed to assist management in primary care, not to replace investigation; using a threshold as diagnostic confirmation — in either direction — is exactly what these three reports warn against.

Source: Synthesis of the reports carded above; no additional source.