SourceMed · Shelf #8281 in the ask interface

KDQOL (Kidney Disease Quality of Life instrument — SF-36 generic core plus kidney-disease-targeted scales) — development in 165 dialysis patients found internal consistency above 0.75 for 18 of 19 scales; the Korean KDQOL-SF validation reports reliability qualitatively with no coefficient in its record, and the Turkish KDQOL-SF 1.3 found test–retest alphas of 0.84 to 0.91

Shelf #8281 · Kidney, fluids & electrolytes

MEASUREMENT PROPERTIES — supported for the short form in two language validations, on a 1994-era long-form development base: development of the dialysis version in 165 patients from nine US centres found internal-consistency estimates for the 19 multi-item scales exceeding 0.75 for every scale except one, scale scores a quarter to a full standard deviation below general-population values, and 14 of 19 scales correlating significantly (p < 0.05) with hospital days in the prior 6 months; the Korean KDQOL-SF (164 haemodialysis and CAPD patients) reported test–retest and internal-consistency reliability as high and construct validity through SF-36 correlations — qualitatively, with no coefficient in its record and none printed from it; the Turkish KDQOL-SF 1.3 (82 dialysis patients) found total test–retest Cronbach's alpha 0.84 to 0.91 and dimension coefficients 0.75 to 0.91, with construct validity against the 15D instrument (best correlation physical functioning vs mobility r = −0.810) — long-form and short-form coefficients are never merged

Stamped: 2026-11-28.

Evidence published: 1994–2007.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the KDQOL (Kidney Disease Quality of Life instrument — an SF-36 generic core plus kidney-disease-targeted scales for dialysis patients, and its KDQOL-SF short form) — what did its development establish in 165 dialysis patients, and what reliability and validity did the Korean and Turkish KDQOL-SF versions find?

Balance of the evidence

Composition prints on the face: 3 reports — 1 programme derivation of the long-form dialysis version (Hays group, 1994) and 2 short-form (KDQOL-SF) language validations (Korean; Turkish KDQOL-SF 1.3). Total patients across reports: 165 + 164 + 82 = 411, reported per study. A fourth report (PMID 15785838, Brazilian KDQOL-SF 1.3 adaptation) was verified at mining and is recorded as corroboration only, not carded. The single pack hit for the instrument's full name elsewhere (#2646) is a trial pack using quality of life as background — discharged at question level.

MeSH: Adult · Aged · Aged, 80 and over · Evaluation Studies as Topic · Female · Health Services Research · Health Status Indicators* · Humans · Kidney Diseases/physiopathology,psychology*,therapy* · Male · Middle Aged · Population Surveillance · Quality of Life* · Renal Dialysis/psychology* · Reproducibility of Results · Surveys and Questionnaires/standards* · Cognition · Interpersonal Relations · Kidney Failure, Chronic/psychology*,therapy · Korea · Language · Peritoneal Dialysis, Continuous Ambulatory · Psychometrics · Quality of Life*/psychology · Renal Dialysis · Surveys and Questionnaires · Attitude to Health · Emotions · Fatigue · Health Status · Kidney Diseases/physiopathology*,psychology* · Pain · Social Behavior · Turkey

Cards (4)

Card 1 — Development of the dialysis version (Hays 1994, Quality of Life Research — 165 patients, nine US outpatient dialysis centres; programme report): internal consistency above 0.75 for 18 of 19 multi-item scales; 14 of 19 scales correlated significantly with hospital days

Study: Instrument development study (primary report; programme report)

Population: 165 individuals with kidney disease on dialysis (52% female; mean age 53 years, range 22 to 87; 47% White, 27% African-American, 11% Hispanic, 8% Asian, 4% Native American, 3% other) sampled from nine outpatient dialysis centres in Southern California, the Northwest and the Midwest, completing the KDQOL: a 36-item health survey as generic core plus kidney-targeted scales (symptoms/problems, effects and burden of kidney disease, cognitive function, work status, sexual function, quality of social interaction, sleep), social support, dialysis staff encouragement, patient satisfaction and an overall health rating.

Summary: Development of the dialysis version (Hays 1994, Quality of Life Research — 165 patients, nine US outpatient dialysis centres; programme report): internal consistency above 0.75 for 18 of 19 multi-item scales; 14 of 19 scales correlated significantly with hospital days

Result: Internal consistency reliability estimates for the 19 multi-item scales exceeded 0.75 for every measure except one. Mean scores on the 36-item health scales were lower than the general population by one-quarter (emotional well-being) to a full standard deviation (physical function, role limitations due to physical health, general health). Correlations of KDQOL scales with hospital days in the last 6 months were statistically significant (p < 0.05) for 14 of the 19 scales, and with number of medications currently taken for nine scales.

Watch out: A 1994-era US dialysis sample prints with its era: dialysis practice, case-mix and survival have changed since, and the development validates the long form — short-form performance cannot be read back from these coefficients.

Source: Hays RD et al. Development of the kidney disease quality of life (KDQOL) instrument. Quality of life research : an international journal of quality of life aspects of treatment, care and rehabilitation. 1994. PMID: 7841967. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Evaluation Studies as Topic · Female · Health Services Research · Health Status Indicators* · Humans · Kidney Diseases/physiopathology,psychology*,therapy* · Male · Middle Aged · Population Surveillance · Quality of Life* · Renal Dialysis/psychology* · Reproducibility of Results · Surveys and Questionnaires/standards*

Card 2 — Korean KDQOL-SF (Park 2007, The Tohoku Journal of Experimental Medicine — 164 haemodialysis and CAPD patients): test–retest and internal-consistency reliability reported high and construct validity supported — qualitatively, no coefficient in the record

Study: Validation study (Korean KDQOL-SF version)

Population: 164 patients on haemodialysis or continuous ambulatory peritoneal dialysis in Korean university dialysis centres, assessed for test–retest reliability, internal consistency and construct validity against the SF-36 scales and an overall health rating.

Summary: Korean KDQOL-SF (Park 2007, The Tohoku Journal of Experimental Medicine — 164 haemodialysis and CAPD patients): test–retest and internal-consistency reliability reported high and construct validity supported — qualitatively, no coefficient in the record

Result: Both test–retest reliability and internal consistency reliability were found to be high (the record reports this qualitatively and states no coefficient, and none is printed from it). The SF-36 scales were highly correlated with each other and with the overall health rating; the overall health rating correlated significantly with the kidney-targeted scales symptoms/problems, effects of kidney disease, burden of kidney disease and cognitive function (p < 0.001), and with quality of social interaction (p < 0.05).

Watch out: A coefficient-free validation: it supports the Korean short form's reliability and validity in the authors' judgement, but no number from it can be quoted, compared or pooled — and this pack does not borrow numbers from the Turkish study to fill the gap.

Source: Park HJ et al. Reliability and validity of the Korean version of Kidney Disease Quality of Life instrument (KDQOL-SF). The Tohoku journal of experimental medicine. 2007. PMID: 17409671. Registry ID: none in the record. MeSH: Adult · Aged · Cognition · Female · Humans · Interpersonal Relations · Kidney Failure, Chronic/psychology*,therapy · Korea · Language · Male · Middle Aged · Peritoneal Dialysis, Continuous Ambulatory · Psychometrics · Quality of Life*/psychology · Renal Dialysis · Reproducibility of Results · Surveys and Questionnaires

Card 3 — Turkish KDQOL-SF 1.3 (Yildirim 2007, Transplantation Proceedings — 82 dialysis patients, three Istanbul hospitals): total test–retest alpha 0.84 to 0.91; dimension coefficients 0.75 to 0.91, most above 0.80; construct validity against the 15D

Study: Validation study (Turkish KDQOL-SF 1.3 version)

Population: 82 patients on dialysis randomly selected from dialysis units of three educational and research hospitals in Istanbul (65% female; mean age 51 ± 12 years; median time on dialysis 3 years; primary renal failure glomerulonephritis 47%, hypertension 31%, diabetes 7%), completing the translated, back-translated Turkish KDQOL-SF 1.3 and the Turkish 15D.

Summary: Turkish KDQOL-SF 1.3 (Yildirim 2007, Transplantation Proceedings — 82 dialysis patients, three Istanbul hospitals): total test–retest alpha 0.84 to 0.91; dimension coefficients 0.75 to 0.91, most above 0.80; construct validity against the 15D

Result: The total test–retest reliability Cronbach's alpha coefficient was 0.84 to 0.91, with coefficients for the 19 dimensions ranging from 0.75 to 0.91 and most components above 0.80 (all P < .05). Construct validity against the 15D showed significant correlations between similar domains, the best being physical functioning vs mobility (r = −0.810), emotional well-being vs mental function (r = −0.784), sexual function vs sexual activity (r = −0.781), and patient satisfaction vs distress (r = −0.801).

Watch out: The smallest anchor in the pack (n = 82) carries the pack's only short-form coefficients; the negative signs on its best correlations reflect the 15D's opposite scoring direction and print as the record gives them.

Source: Yildirim A et al. Translation, cultural adaptation, initial reliability, and validation of the Kidney Disease and Quality of Life-Short Form (KDQOL-SF 1.3) in Turkey. Transplantation proceedings. 2007. PMID: 17275473. Registry ID: none in the record. MeSH: Attitude to Health · Emotions · Fatigue · Health Status · Humans · Kidney Diseases/physiopathology*,psychology* · Pain · Quality of Life* · Reproducibility of Results · Social Behavior · Surveys and Questionnaires · Turkey

Card 4 — Synthesis: a long-form development plus two short-form transports, one of them coefficient-free — 3 reports (1 programme derivation, 2 language validations)

Study: Synthesis

Population: 411 patients across the three reports (165 + 164 + 82), reported per study and never pooled; the Brazilian KDQOL-SF 1.3 adaptation (PMID 15785838) is corroboration only, not carded.

Summary: Synthesis: a long-form development plus two short-form transports, one of them coefficient-free — 3 reports (1 programme derivation, 2 language validations)

Result: The development supports the long form's internal consistency (above 0.75 for 18 of 19 scales) and its association with hospital use. The Turkish short-form validation supplies the quantitative short-form reliability (alphas 0.75–0.91). The Korean validation supports reliability and construct validity only qualitatively — its record carries no coefficient, which is printed on its face rather than filled in. No report was refused on this row. The stamp is MEASUREMENT PROPERTIES with the long-form/short-form boundary in the stamp sentence, because merging the two forms' coefficients is the error this pack exists to prevent.

Watch out: Quality-of-life instruments age with the treatment era that produced them; a 1994 dialysis development base should be cited with its era attached.

Source: Synthesis of the reports carded above; no additional source.