SourceMed · Shelf #8310 in the ask interface

NEI VFQ-25 (25-item National Eye Institute Visual Function Questionnaire): development record prints no N and no coefficient; Proyecto VER population validation in 4,774 Hispanic persons found subscale alphas 0.65–0.86 and 25% Driving-scale non-response; Turkish version (n = 61) overall alpha 0.97 — 3 reports carded

Shelf #8310 · Eyes, skin, nose & allergy

MEASUREMENT PROPERTIES — supported as a cross-condition vision-related quality-of-life measure, with uneven subscale reliability in a general population: the development record establishes short–long form comparability qualitatively (no N or coefficient printed); Proyecto VER (n = 4,774) found subscale alphas 0.65–0.86, significantly lower scores at acuity worse than 20/40 on all scales, and 25% non-response on the Driving scale for non-vision reasons; the Turkish version (n = 61) found overall alpha 0.97 and subscale alphas 0.78–0.94; a measurement stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 1960–2005.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the NEI VFQ-25 (the 25-item National Eye Institute Visual Function Questionnaire — vision-related quality of life across general vision, ocular pain, near/distance activities, social functioning, mental health, role difficulties, dependency, driving, colour and peripheral vision) — what did its development establish against the 51-item field-test version, and what reliability and validity did the population-based Hispanic (Proyecto VER) and Turkish versions find?

Balance of the evidence

Composition prints on the face: 1 programme development report (TYPE-FLAG on its card: typed Clinical Trial for a prospective observational cohort; no total N or coefficient in its record) + 1 large population validation + 1 small clinic validation. Cross-points: VF-14 (#8312); the VFQ-25 limb inside the OSDI derivation (#8311) is a comparator limb there.

MeSH: Chronic Disease · Cohort Studies · Eye Diseases/physiopathology · Health Surveys · Humans · Middle Aged · National Institutes of Health (U.S.) · Ophthalmology · Prospective Studies · Psychometrics · Reproducibility of Results · Sickness Impact Profile* · Surveys and Questionnaires* · United States · Vision, Low/physiopathology · Visual Acuity/physiology* · Activities of Daily Living · Adult · Aged · Aged, 80 and over · Arizona/epidemiology · Female · Hispanic or Latino* · Male · Psychometrics/standards* · Vision Disorders/ethnology,physiopathology* · Vision Tests · Vision, Ocular/physiology* · Cross-Cultural Comparison · Cross-Sectional Studies · Eye Diseases/epidemiology,physiopathology* · Language · Quality of Life* · Turkey · Vision Tests/instrumentation*,methods

Cards (4)

Card 1 — Development (Mangione 2001, Arch Ophthalmol — prospective cohort across five chronic eye diseases, low vision and a no-disease reference sample at 11 practices and the NEI Clinical Center): subscales reliable; short–long form correlations high; record prints no total N and no coefficient

Study: Development study (prospective observational cohort; TYPE-FLAG as stated in people field)

Population: Persons aged ≥21 with age-related cataract, age-related macular degeneration, diabetic retinopathy, primary open-angle glaucoma, cytomegalovirus retinitis or low vision, plus a reference sample without eye disease at 7 of 12 sites; all completed the 51-item NEI VFQ from which the 25-item version was derived. Programme report: the Mangione/NEI group's own derivation. Typed Clinical Trial / Multicenter Study at PubMed for a prospective observational cohort (TYPE-FLAG). The record states no total sample size and no coefficient, and none is printed here.

Summary: Development (Mangione 2001, Arch Ophthalmol — prospective cohort across five chronic eye diseases, low vision and a no-disease reference sample at 11 practices and the NEI Clinical Center): subscales reliable; short–long form correlations high; record prints no total N and no coefficient

Result: Estimates of internal consistency indicate the NEI VFQ-25 subscales are reliable. Validity was supported by high correlations between the short- and long-form versions, between-group differences by disease and severity, and moderate-to-high correlations of the central-vision subscales with measured visual acuity. The authors conclude the 25-item version's reliability and validity are comparable to the 51-item field-test version.

Watch out: The derivation's claims are qualitative in its record — every number on this pack comes from the two validations and prints by version and population.

Source: Mangione CM et al. Development of the 25-item National Eye Institute Visual Function Questionnaire. Archives of ophthalmology (Chicago, Ill. : 1960). 2001. PMID: 11448327. Registry ID: none in the record. MeSH: Chronic Disease · Cohort Studies · Eye Diseases/physiopathology · Health Surveys · Humans · Middle Aged · National Institutes of Health (U.S.) · Ophthalmology · Prospective Studies · Psychometrics · Reproducibility of Results · Sickness Impact Profile* · Surveys and Questionnaires* · United States · Vision, Low/physiopathology · Visual Acuity/physiology*

Card 2 — Proyecto VER (Broman 2001, Invest Ophthalmol Vis Sci — population-based sample of 4,774 older Hispanic persons in Arizona, 99.7% completing): subscale alphas 0.65–0.86; Driving scale 25% non-response

Study: Validation study (population-based)

Population: 4,774 randomly sampled older Hispanic persons in Tucson and Nogales, Arizona, interviewed at home (majority in Spanish) with presenting acuity measured by ETDRS methods and a standardised eye examination.

Summary: Proyecto VER (Broman 2001, Invest Ophthalmol Vis Sci — population-based sample of 4,774 older Hispanic persons in Arizona, 99.7% completing): subscale alphas 0.65–0.86; Driving scale 25% non-response

Result: Internal consistency Cronbach alpha ranged 0.65–0.86 across multi-item scales. Adjusting for age and gender, participants with presenting acuity worse than 20/40 scored significantly lower on all scales. The highest non-response was the Driving scale, with 25% not driving for reasons other than vision problems. No significant reporting differences were found between the Spanish and English versions in the interviewer-controlled subset.

Watch out: A population sample, not a clinic sample: many respondents have no eye disease, which bounds the score distributions; the alpha low end of 0.65 is a real subscale in this population and prints. A quarter of respondents cannot answer the Driving scale for non-vision reasons.

Source: Broman AT et al. Psychometric properties of the 25-item NEI-VFQ in a Hispanic population: Proyecto VER. Investigative ophthalmology & visual science. 2001. PMID: 11222517. Registry ID: none in the record. MeSH: Activities of Daily Living · Adult · Aged · Aged, 80 and over · Arizona/epidemiology · Female · Hispanic or Latino* · Humans · Male · Middle Aged · Psychometrics/standards* · Reproducibility of Results · Sickness Impact Profile* · Surveys and Questionnaires* · Vision Disorders/ethnology,physiopathology* · Vision Tests · Vision, Ocular/physiology*

Card 3 — Turkish version (Toprak 2005, Ophthalmic Epidemiol — 61 patients with chronic eye disease): overall alpha 0.97, subscale alphas 0.78–0.94; WHOQOL-BREF correlations r = 0.26–0.68

Study: Validation study (language transport)

Population: 61 patients (mean age 60.9 ± 14.5 years) with cataract (57.4%), diabetic retinopathy (13.2%), macular degeneration (11.4%), glaucoma (9.8%) or degenerative myopia (8.2%). Small N (61) prints on the face.

Summary: Turkish version (Toprak 2005, Ophthalmic Epidemiol — 61 patients with chronic eye disease): overall alpha 0.97, subscale alphas 0.78–0.94; WHOQOL-BREF correlations r = 0.26–0.68

Result: Overall Cronbach alpha 0.97, subscale alphas 0.78–0.94. WHOQOL-BREF domain correlations with the NEI-VFQ 25 ranged r = 0.26–0.68. Patients with lower visual acuity had significantly lower index scores (p = 0.001).

Watch out: N = 61 across five diagnoses — per-diagnosis numbers are in single digits for some conditions, so the version's figures are whole-sample figures only.

Source: Toprak AB et al. Cross-validation of the Turkish version of the 25-item National Eye Institute Visual Functioning Questionnaire (NEI-VFQ 25). Ophthalmic epidemiology. 2005. PMID: 16033747. Registry ID: none in the record. MeSH: Cross-Cultural Comparison · Cross-Sectional Studies · Eye Diseases/epidemiology,physiopathology* · Female · Health Surveys · Humans · Language · Male · Middle Aged · National Institutes of Health (U.S.) · Ophthalmology · Quality of Life* · Reproducibility of Results · Sickness Impact Profile* · Surveys and Questionnaires* · Turkey · United States · Vision Tests/instrumentation*,methods · Visual Acuity/physiology*

Card 4 — Synthesis — 3 reports: 1 programme development report (no N or coefficient in its record) + 1 large population validation (n = 4,774) + 1 small clinic validation (n = 61)

Study: Synthesis

Population: Documented samples: 4,774 (population) and 61 (clinic); the derivation record states no total N. Never pooled — a general-population sample and a chronic-eye-disease clinic sample answer different questions.

Summary: Synthesis — 3 reports: 1 programme development report (no N or coefficient in its record) + 1 large population validation (n = 4,774) + 1 small clinic validation (n = 61)

Result: Composition: 1 programme development + 2 validations. The OSDI derivation's NEI VFQ-25 limb (pack #8311) is a comparator limb there, not carded here. Cross-points: VF-14 (#8312) is the cataract-specific function index and Catquest-9SF the Rasch-scaled cataract instrument; the VFQ-25 is the cross-condition vision-related quality-of-life standard.

Watch out: Subscale reliability is uneven (Proyecto VER alpha low end 0.65) and the Driving scale is unanswerable for a quarter of a general population — both print wherever subscale or driving scores are used.

Source: Synthesis of the reports carded above; no additional source.