VF-14 (Visual Function Index — 14 items, cataract functional impairment): development in 766 first-time cataract surgery patients, alpha 0.85; French version (n = 66) alpha 0.96, ICCs ≥ 0.80; international study (n = 1,407) alphas ≥ 0.84 with effect sizes 1.01–1.17 — its US limb (n = 766) overlaps the derivation cohort, printed as such — 3 reports carded
Shelf #8312 · Eyes, skin, nose & allergy
MEASUREMENT PROPERTIES — supported for cataract-specific functional impairment across four countries: development (n = 766) alpha 0.85, correlating more strongly with patients' trouble and satisfaction than with acuity; French version (n = 66) alpha 0.96 with fidelity, test–retest and interrater ICCs ≥ 0.80; international study (n = 1,407) alphas ≥ 0.84 at all sites, Vision-Related SIP correlations −0.68 (non-US) and −0.57 (US), and change effect sizes 1.01 (non-US) and 1.17 (US) in improvers — with the US limb (n = 766) overlapping the derivation cohort, printed as such; a measurement stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1960–1997.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the VF-14 (Visual Function Index — 14 items on vision-dependent activities, for functional impairment from cataract) — what did its development in 766 first-time cataract surgery patients establish, and what reliability and responsiveness did the French-language and four-country international studies find?
Balance of the evidence
Composition prints on the face: 1 programme derivation + 1 programme-linked international study (US limb n = 766 overlaps the derivation cohort — never counted as an independent US sample) + 1 independent language validation (shared report; its Cataract Symptom Score limb is a comparator limb). Cross-points: NEI VFQ-25 (#8310).
MeSH: Cataract/physiopathology* · Cataract Extraction · Cross-Sectional Studies · Factor Analysis, Statistical · Female · Humans · Linear Models · Male · Middle Aged · Severity of Illness Index* · Surveys and Questionnaires · Treatment Outcome · Vision, Ocular* · Adult · Aged · Aged, 80 and over · Cataract/classification,physiopathology* · Health Status Indicators · Language* · Predictive Value of Tests · Reproducibility of Results · Retrospective Studies · Vision Tests/methods* · Vision, Ocular/physiology* · Visual Acuity/physiology* · Cataract Extraction* · Longitudinal Studies · Patient Satisfaction · Sickness Impact Profile · Vision Tests/instrumentation*
Cards (4)
Card 1 — Development (Steinberg 1994, Arch Ophthalmol — 766 first-time cataract surgery patients from 70 ophthalmologists in Columbus, St Louis and Houston): alpha 0.85; correlated more strongly with trouble/satisfaction than acuity or the Sickness Impact Profile
Study: Development and performance study (programme report)
Population: 766 patients undergoing cataract surgery for the first time, recruited July–December 1991. Programme report: the Steinberg group's own derivation.
Summary: Development (Steinberg 1994, Arch Ophthalmol — 766 first-time cataract surgery patients from 70 ophthalmologists in Columbus, St Louis and Houston): alpha 0.85; correlated more strongly with trouble/satisfaction than acuity or the Sickness Impact Profile
Result: The VF-14 had high internal consistency (Cronbach's alpha = 0.85) and correlated more strongly with patients' overall self-rating of trouble and satisfaction with vision than did visual acuity measures or the Sickness Impact Profile. The VF-14 score was moderately correlated with visual acuity in the better eye (the record's wording; no coefficient printed for that correlation in the abstract's results as fetched, beyond the qualitative statement).
Watch out: A preoperative cross-sectional study in surgical candidates: its correlations describe patients already selected for surgery, not the general cataract population.
Source: Steinberg EP et al. The VF-14. An index of functional impairment in patients with cataract. Archives of ophthalmology (Chicago, Ill. : 1960). 1994. PMID: 8185520. Registry ID: none in the record. MeSH: Cataract/physiopathology* · Cataract Extraction · Cross-Sectional Studies · Factor Analysis, Statistical · Female · Humans · Linear Models · Male · Middle Aged · Severity of Illness Index* · Surveys and Questionnaires · Treatment Outcome · Vision, Ocular*
Card 2 — French-language version (Gresset 1997, Can J Ophthalmol — 66 completers of 71 recruited, cataracts or corneal opacities, Montreal): VF-14 alpha 0.96; fidelity, test–retest and interrater ICCs ≥ 0.80 — SHARED REPORT (its Cataract Symptom Score limb is a comparator limb)
Study: Validation study (language transport; shared report — CSS limb printed as shared)
Population: 71 patients with ocular media opacities at a Montreal teaching hospital recruited; 66 (41 French-speaking, 25 French- and English-speaking) completed telephone interviews 2 weeks apart. Small N (66) prints on the face.
Summary: French-language version (Gresset 1997, Can J Ophthalmol — 66 completers of 71 recruited, cataracts or corneal opacities, Montreal): VF-14 alpha 0.96; fidelity, test–retest and interrater ICCs ≥ 0.80 — SHARED REPORT (its Cataract Symptom Score limb is a comparator limb)
Result: French VF-14 internal consistency alpha 0.96 (Cataract Symptom Score 0.82). Fidelity to the English version, test–retest reproducibility and interrater agreement were all high (intraclass correlation coefficients ≥ 0.80). VF-14 scores correlated with five of the eight SF-36 subscales, and better-eye acuity correlated significantly with all four vision measures.
Watch out: The sample mixes cataract with corneal opacity and is small; telephone administration differs from the original mode and bounds direct comparability.
Source: Gresset J et al. Validation of French-language versions of the Visual Functioning Index (VF-14) and the Cataract Symptom Score. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 1997. PMID: 9047031. Registry ID: none in the record. MeSH: Adult · Aged · Aged, 80 and over · Cataract/classification,physiopathology* · Female · Health Status Indicators · Humans · Language* · Male · Middle Aged · Predictive Value of Tests · Reproducibility of Results · Retrospective Studies · Surveys and Questionnaires · Vision Tests/methods* · Vision, Ocular/physiology* · Visual Acuity/physiology*
Card 3 — International applicability (Alonso 1997, Ophthalmology — 1,407 first-eye cataract surgery patients: Manitoba 152, Denmark 291, Barcelona 198, United States 766; 1,284 at 4-month follow-up): alphas ≥ 0.84 at all sites; change effect sizes 1.01 (non-US) and 1.17 (US) — PROGRAMME-LINKED: the US limb (n = 766) overlaps the derivation cohort and is printed as such
Study: International validation study (programme-linked; US limb overlaps derivation cohort)
Population: 1,407 first-eye cataract surgery patients across four sites, evaluated before surgery and at 4 months; 1,284 (91.3%) completed follow-up. The US limb's N (766) and structure match the derivation cohort — treated as overlapping/programme-linked, never as a second independent US sample.
Summary: International applicability (Alonso 1997, Ophthalmology — 1,407 first-eye cataract surgery patients: Manitoba 152, Denmark 291, Barcelona 198, United States 766; 1,284 at 4-month follow-up): alphas ≥ 0.84 at all sites; change effect sizes 1.01 (non-US) and 1.17 (US) — PROGRAMME-LINKED: the US limb (n = 766) overlaps the derivation cohort and is printed as such
Result: Internal consistency alpha ≥ 0.84 at all sites. Correlation with the Vision-Related Sickness Impact Profile was r = −0.68 (non-US) and −0.57 (US); with better-eye acuity r = 0.40 and 0.27. In improvers after first-eye surgery, VF-14 change effect sizes were 1.01 (non-US) and 1.17 (US).
Watch out: Counting the US 766 twice — once as derivation and once as international validation — would double-count one cohort; this pack counts it once and prints the overlap. Responsiveness is shown in surgical improvers, the population the instrument was built for.
Source: Alonso J et al. International applicability of the VF-14. An index of visual function in patients with cataracts. Ophthalmology. 1997. PMID: 9160026. Registry ID: none in the record. MeSH: Aged · Cataract/physiopathology* · Cataract Extraction* · Female · Humans · Longitudinal Studies · Male · Middle Aged · Patient Satisfaction · Reproducibility of Results · Sickness Impact Profile · Treatment Outcome · Vision Tests/instrumentation* · Visual Acuity/physiology*
Card 4 — Synthesis — 3 reports: 1 programme derivation (n = 766), 1 programme-linked international study (n = 1,407, whose US limb of 766 overlaps the derivation cohort), 1 independent language validation (n = 66)
Study: Synthesis
Population: Unique documented patients: the international study's non-US limbs contribute 641 patients (152 + 291 + 198) beyond the derivation's 766; the French study adds 66. Totals are stated by limb, never pooled into a single N that double-counts the US cohort.
Summary: Synthesis — 3 reports: 1 programme derivation (n = 766), 1 programme-linked international study (n = 1,407, whose US limb of 766 overlaps the derivation cohort), 1 independent language validation (n = 66)
Result: Composition: 1 programme derivation + 1 programme-linked international study + 1 independent transport — printed as such, with the US-limb overlap on the face of its card, the balance and this synthesis. Cross-points: NEI VFQ-25 (#8310) is the cross-condition instrument; Catquest-9SF is the Rasch-scaled cataract successor. The VF-14 is cataract-specific by construction and its scores must not be presented as general vision-related quality of life.
Watch out: The derivation and the largest validation share a cohort; independence on this row comes from the non-US limbs (641 patients) and the small French study only.
Source: Synthesis of the reports carded above; no additional source.