PRO-CTCAE patient-reported toxicity item library: four reports — a 124-item library for 78 symptomatic adverse events; 119 of 124 items met a construct-validity criterion in the US validation, but only 36 of 49 prespecified items reached test–retest ICC ≥ 0.7 and the Japanese version's mean reproducibility ICC was 0.63
Shelf #8343 · Cancer
MEASUREMENT PROPERTIES — item-level validity supported, reliability heterogeneous by item: in the US validation (975 enrolled, 940 completing visit 1), 119 of 124 items met at least one construct-validity criterion, but test–retest ICC reached ≥ 0.7 for only 36 of 49 prespecified items (median 0.76, range 0.53–0.96); the Japanese version's mean reproducibility ICC was 0.63; the preferred recall period is the past 7 days. Composition 4 reports — 1 programme development report written in Commentary form, 1 programme US validation, 1 Japanese transport and 1 recall-period study. The PRO-CTCAE is an item library with no total score; no library-level reliability figure exists and none may be printed
Stamped: 2026-11-28.
Evidence published: 2014–2017.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the PRO-CTCAE (the US National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events — a library of 124 items covering 78 symptomatic adverse events, each rated for frequency, severity and/or interference) — how was the library developed, what validity, reliability and responsiveness did the US validation find, what did the Japanese version find, and which recall period matches daily reporting?
Balance of the evidence
Composition prints on the face: 4 reports — the NCI programme's own development report (PMID 25265940, written in Commentary form and counted on substance as the development report; its record states no cognitive-interviewing sample size), the programme's US validation (975 enrolled; 940 at visit 1, 852 at visit 2), a Japanese transport (187 patients on systemic therapy) and a recall-period evaluation (127 patients). Documented quantitative samples total 975 + 187 + 127 = 1,289 patients; the development report's N is not documented and is never added. The instrument is an item library for trial adverse-event reporting, not a fixed questionnaire: the EORTC QLQ-C30 appears inside two anchors as the construct comparator — its own measurement home is pack #8332, cross-pointed in prose only. Clinician CTCAE grading is the reporting tradition this library was built to correct for underdetection; no card here is evidence about any drug's toxicity.
MeSH: Adverse Drug Reaction Reporting Systems* · Antineoplastic Agents/adverse effects* · Humans · National Cancer Institute (U.S.) · Neoplasms/drug therapy* · Patient Outcome Assessment · Self Report* · Surveys and Questionnaires · Terminology as Topic* · United States · Adult · Adverse Drug Reaction Reporting Systems/classification* · Aged · Aged, 80 and over · Ambulatory Care · Chemoradiotherapy/adverse effects* · Computers, Handheld · Drug-Related Side Effects and Adverse Reactions/classification*,etiology · Female · Male · Middle Aged · National Cancer Institute (U.S.)* · Neoplasms/diagnosis,drug therapy*,radiotherapy* · Quality of Life · Radiation Injuries/classification*,etiology · Radiotherapy/adverse effects · Reproducibility of Results · Self Report · Surveys and Questionnaires* · Time Factors · Treatment Outcome · Young Adult · Adverse Drug Reaction Reporting Systems/classification*,statistics & numerical data · Chemoradiotherapy/adverse effects · Mental Recall · Neoplasms*/drug therapy,radiotherapy · Patient Reported Outcome Measures*
Cards (5)
Card 1 — Development of the library (Basch 2014, Journal of the National Cancer Institute — programme report in Commentary form): 78 of 790 CTCAE adverse events judged suitable for patient self-report, rendered as 124 plain-language items
Study: Development report (programme — NCI group; TYPE-FLAG: typed Journal Article at PubMed and its abstract calls itself 'This Commentary'; counted on substance as the programme's development report)
Population: Patients on active cancer treatment with diverse educational, racial and geographic backgrounds took part in the cognitive interviewing that refined the items; the record states no sample size for that study — N not documented.
Summary: Development of the library (Basch 2014, Journal of the National Cancer Institute — programme report in Commentary form): 78 of 790 CTCAE adverse events judged suitable for patient self-report, rendered as 124 plain-language items
Result: A systematic evaluation of all 790 adverse events listed in the CTCAE identified 78 appropriate for patient self-reporting. For each, one to three plain-language items characterising frequency, severity and/or activity interference were created, rendering a library of 124 PRO-CTCAE items, refined in cognitive interviewing among patients on active treatment. The report states that favourable measurement properties — construct validity, reliability, responsiveness and between-mode equivalence — were determined prospectively in a demographically diverse treatment population; the quantitative study behind that summary is carded next and carries the numbers.
Watch out: Programme-labelled: the NCI group's own report, in Commentary form. No psychometric coefficient is printed from this record — the checkable numbers on this pack come from the validation, transport and recall cards.
Source: Basch E et al. Development of the National Cancer Institute's patient-reported outcomes version of the common terminology criteria for adverse events (PRO-CTCAE). Journal of the National Cancer Institute. 2014. PMID: 25265940. Registry ID: none in the record. MeSH: Adverse Drug Reaction Reporting Systems* · Antineoplastic Agents/adverse effects* · Humans · National Cancer Institute (U.S.) · Neoplasms/drug therapy* · Patient Outcome Assessment · Self Report* · Surveys and Questionnaires · Terminology as Topic* · United States
Card 2 — US validity and reliability study (Dueck 2015, JAMA Oncology — 975 enrolled at 9 US centres): 119 of 124 items met at least one construct-validity criterion; test–retest ICC ≥ 0.7 for 36 of 49 prespecified items (median 0.76, range 0.53–0.96)
Study: Validation study (programme — US multicentre validation)
Population: 975 adults with cancer undergoing outpatient chemotherapy and/or radiation therapy at 9 US cancer centres and community practices; 940 (96.4%) completed PRO-CTCAE items at visit 1 and 852 at visit 2, 1–6 weeks apart; median age 59 years, 57.3% female, 17.1% with ECOG performance status 2 to 4.
Summary: US validity and reliability study (Dueck 2015, JAMA Oncology — 975 enrolled at 9 US centres): 119 of 124 items met at least one construct-validity criterion; test–retest ICC ≥ 0.7 for 36 of 49 prespecified items (median 0.76, range 0.53–0.96)
Result: All PRO-CTCAE items had at least one correlation in the expected direction with a QLQ-C30 scale (111 of 124, P < .05 for all), with stronger correlations for conceptually related domains; scores for 94 of 124 items were higher in the ECOG PS 2 to 4 group than the 0 to 1 group (58 of 124, P < .05 for all); overall 119 of 124 items met at least one construct-validity criterion. Test–retest reliability was 0.7 or greater for 36 of 49 prespecified items (median ICC 0.76, range 0.53–0.96). Correlations between item changes and corresponding QLQ-C30 scale changes were statistically significant for 27 prespecified items (median r = 0.43, range 0.10–0.56; all P ≤ .006). At least one symptom was reported by 938 of 940 participants (99.8%).
Watch out: The heterogeneity prints at full weight: 13 of the 49 prespecified items fell below ICC 0.7, so 'the PRO-CTCAE is reliable' is not a claim this pack makes — reliability is item-level. Programme validation by the developing group.
Source: Dueck AC et al. Validity and Reliability of the US National Cancer Institute's Patient-Reported Outcomes Version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE). JAMA oncology. 2015. PMID: 26270597. Registry ID: none in the record. MeSH: Adult · Adverse Drug Reaction Reporting Systems/classification* · Aged · Aged, 80 and over · Ambulatory Care · Antineoplastic Agents/adverse effects* · Chemoradiotherapy/adverse effects* · Computers, Handheld · Drug-Related Side Effects and Adverse Reactions/classification*,etiology · Female · Humans · Male · Middle Aged · National Cancer Institute (U.S.)* · Neoplasms/diagnosis,drug therapy*,radiotherapy* · Quality of Life · Radiation Injuries/classification*,etiology · Radiotherapy/adverse effects · Reproducibility of Results · Self Report · Surveys and Questionnaires* · Terminology as Topic* · Time Factors · Treatment Outcome · United States · Young Adult
Card 3 — Japanese version (Kawaguchi 2017, Journal of Patient-Reported Outcomes — 187 patients on systemic therapy): corresponding-item correlations with the QLQ-C30 r = 0.56–0.76, but mean reproducibility ICC 0.63, and clinician–patient discordance observed
Study: Validation study (independent language transport)
Population: 187 cancer patients receiving systemic therapy in Japan (mean age 62.4 years): 187 analysed for criterion validity, 80 for reproducibility and 100 for responsiveness.
Summary: Japanese version (Kawaguchi 2017, Journal of Patient-Reported Outcomes — 187 patients on systemic therapy): corresponding-item correlations with the QLQ-C30 r = 0.56–0.76, but mean reproducibility ICC 0.63, and clinician–patient discordance observed
Result: All patients responded to at least one symptom item (mean 16 items). The mean intraclass correlation coefficient for overall reproducibility of the Japanese PRO-CTCAE was 0.63 (SD 0.02). Correlation coefficients for corresponding items in the EORTC QLQ-C30 and the Japanese PRO-CTCAE were high (Pearson r = 0.56–0.76). Responsiveness analysis revealed significant dose–response trends (Jonckheere–Terpstra test, all ps < 0.001). Depending on the adverse event, a discrepancy was observed between clinician and patient evaluations — the underestimation the instrument exists to correct.
Watch out: The Japanese mean ICC of 0.63 sits below the US validation's median of 0.76 — a mean and a median over different item sets, printed as each record states them, never averaged. This record carries no MeSH in PubMed, and its source line says so.
Source: Kawaguchi T et al. The Japanese version of the National Cancer Institute's patient-reported outcomes version of the common terminology criteria for adverse events (PRO-CTCAE): psychometric validation and discordance between clinician and patient assessments of adverse events. Journal of patient-reported outcomes. 2017. PMID: 29757309. Registry ID: none in the record. MeSH: none in the record
Card 4 — Recall-period evaluation (Mendoza 2017, Clinical Trials — 127 patients, 27 items reported daily for 28 days): score differences from daily reporting grew with recall length (−0.20 at 1 week to −0.47 at 4 weeks); the preferred recall is the past 7 days
Study: Evaluation study (recall-period comparison against daily reporting)
Population: 127 English-speaking patients with cancer receiving chemotherapy and/or radiotherapy at four US cancer centres and affiliated community clinics (57% male; median age 57), completing 27 PRO-CTCAE items daily for 28 days and then weekly with 1-, 2-, 3- and 4-week recall.
Summary: Recall-period evaluation (Mendoza 2017, Clinical Trials — 127 patients, 27 items reported daily for 28 days): score differences from daily reporting grew with recall length (−0.20 at 1 week to −0.47 at 4 weeks); the preferred recall is the past 7 days
Result: The median of the 27 mean differences on the 5-point response scale, comparing the maximum daily rating with the longer-recall rating, was −0.20 for 1-week recall, −0.36 for 2 weeks, −0.45 for 3 weeks and −0.47 for 4 weeks (effect sizes −0.20 to −0.40). Median intraclass correlations against the maximum of daily ratings stayed stable: 0.70 (1 week), 0.74 (2 weeks), 0.72 (3 weeks) and 0.72 (4 weeks). The authors conclude a 1-week recall corresponds best to daily reporting and the preferred recall period is the past 7 days, with longer recalls carrying some information loss.
Watch out: Stable ICCs alongside growing mean differences is the finding: agreement statistics alone would hide the drift. The −0.20 to −0.47 differences are on the items' 5-point scale and print as such.
Source: Mendoza TR et al. Evaluation of different recall periods for the US National Cancer Institute's PRO-CTCAE. Clinical trials (London, England). 2017. PMID: 28545337. Registry ID: none in the record. MeSH: Adult · Adverse Drug Reaction Reporting Systems/classification*,statistics & numerical data · Aged · Antineoplastic Agents/adverse effects* · Chemoradiotherapy/adverse effects · Drug-Related Side Effects and Adverse Reactions/classification*,etiology · Female · Humans · Male · Mental Recall · Middle Aged · National Cancer Institute (U.S.) · Neoplasms*/drug therapy,radiotherapy · Patient Reported Outcome Measures* · Self Report · Time Factors · United States · Young Adult
Card 5 — Synthesis — a validated item library, not a validated total score: validity is broad (119 of 124 items), reliability is item-by-item, and recall beyond 7 days drifts
Study: Synthesis
Population: 4 reports carded: 1 programme development report (N not documented in its record), 1 programme US validation (975 enrolled), 1 Japanese transport (187) and 1 recall-period study (127) — documented quantitative samples total 1,289 patients.
Summary: Synthesis — a validated item library, not a validated total score: validity is broad (119 of 124 items), reliability is item-by-item, and recall beyond 7 days drifts
Result: The library's construction is systematic (78 of 790 CTCAE events rendered as 124 items) and its construct validity is broad, but the reliability picture is heterogeneous by construction: 36 of 49 prespecified items at ICC ≥ 0.7 in the US study, a mean reproducibility ICC of 0.63 in the Japanese version, and recall-period drift that grows from −0.20 (1 week) to −0.47 (4 weeks) against daily reporting. Stamp justification: MEASUREMENT PROPERTIES with the heterogeneity inside the stamp — a shelf printing a blanket 'reliable' claim, or any library-level total-score property, would contradict its own cards. No report was refused on this row; the companion measurement studies the development report summarises are represented by the Dueck validation carded here.
Watch out: Cross-points in prose only: the QLQ-C30 (pack #8332) is the comparator inside the US and Japanese anchors, not a shared anchor; the MSAS (pack #8342), MDASI (pack #8340) and ESAS (pack #8341) are symptom inventories with total/subscale scores — a different architecture from this item library, and their figures never transfer here.
Source: Synthesis of the reports carded above; no additional source.