SourceMed · Shelf #8347 in the ask interface

Calgary Sleep Apnea Quality of Life Index (SAQLI): three reports — the derivation record prints no coefficient; the measurement-properties study found a responsiveness index of 1.9 around a nasal CPAP trial and 2-week test–retest of 0.92; the Chinese factor analysis supported only two of the four domains' hypothesised loadings

Shelf #8347 · Lungs, breathing & sleep

MEASUREMENT PROPERTIES — responsiveness strong as an evaluative index, derivation coefficient-free in its record: responsiveness index 1.9 and effect size 1.1 around a nasal CPAP trial, much greater than the SF-36 domains and the Ferrans and Powers index, with 2-week test–retest reliability 0.92; the Chinese version was good to excellent on consistency, validity and responsiveness but its factor analysis found only the daily-functioning and symptom domains' items all loading on their hypothesised scales. Composition 3 reports — 1 programme development, 1 programme measurement-properties study (typed Clinical Trial at PubMed, counted on substance) and 1 independent language transport. The responsiveness limb is an instrument property, not evidence about CPAP itself

Stamped: 2026-11-28.

Evidence published: 1998–2004.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the SAQLI (Calgary Sleep Apnea Quality of Life Index — 35 items in four domains: daily functioning, social interactions, emotional functioning, and symptoms, with an optional fifth treatment-related-symptoms domain for intervention trials) — what did its development establish, what responsiveness and reliability did its measurement-properties study find around a CPAP trial, and what did the Chinese version find?

Balance of the evidence

Composition prints on the face: 3 reports — the Flemons group's own development (items selected from interviews with 113 sleep-apnoea patients and 50 snorers), the same programme's measurement-properties study run around a trial of nasal CPAP (its record states no sample size — N not documented, and none is printed), and a Chinese (Cantonese) transport in Hong Kong (106 patients cross-sectionally, 51 longitudinally). Documented samples total 113 + 50 + 106 + 51 across different counting roles (item-selection informants; cross-sectional and longitudinal validation samples) and are never pooled into one cohort. Distinct from pack #8346 (FOSQ): the SAQLI is apnoea-specific and carries an optional treatment-symptoms domain; the FOSQ measures functional outcomes of excessive sleepiness generally.

MeSH: Adult · Female · Focus Groups · Health Status Indicators* · Humans · Male · Middle Aged · Quality of Life* · Sleep Apnea Syndromes* · Surveys and Questionnaires* · Discriminant Analysis · Health Status Indicators · Patient Compliance · Polysomnography · Positive-Pressure Respiration* · Reproducibility of Results · Severity of Illness Index · Sleep Apnea Syndromes/physiopathology,therapy* · Surveys and Questionnaires · Cross-Cultural Comparison · Cross-Sectional Studies · Hong Kong · Patient Acceptance of Health Care · Psychometrics · Sleep Apnea, Obstructive/ethnology*,psychology,rehabilitation · Socioeconomic Factors

Cards (4)

Card 1 — Development (Flemons 1998, American Journal of Respiratory and Critical Care Medicine — programme report): 35 items in four domains selected by frequency × importance ranking from 113 sleep-apnoea patients and 50 snorers; the record prints no coefficient values

Study: Development report (programme — construction and validity claims; coefficient-free in the record)

Population: 113 patients with sleep apnea and 50 snorers, interviewed to identify and rank every item felt to influence quality of life, rating each on whether it was a problem and its importance; rank ordering was similar across strata of disease severity and between sexes.

Summary: Development (Flemons 1998, American Journal of Respiratory and Critical Care Medicine — programme report): 35 items in four domains selected by frequency × importance ranking from 113 sleep-apnoea patients and 50 snorers; the record prints no coefficient values

Result: Items for the final questionnaire were selected by the rank order of the frequency × importance product. The Calgary SAQLI has 35 questions in four domains — daily functioning, social interactions, emotional functioning, and symptoms — with a fifth domain, treatment-related symptoms, addable for clinical intervention trials. The record reports a high degree of internal consistency, face validity as judged by content experts and patients, and construct validity shown by positive correlations with the SF-36 and by score improvement in patients completing a 4-week trial of continuous positive airway pressure. It prints no numeric coefficient, and none is printed here.

Watch out: Programme-labelled: the Flemons group's own report. Every number on this pack comes from the measurement-properties and Chinese cards; this card establishes what the instrument is and how its items were chosen, nothing more.

Source: Flemons WW et al. Development of a disease-specific health-related quality of life questionnaire for sleep apnea. American journal of respiratory and critical care medicine. 1998. PMID: 9700127. Registry ID: none in the record. MeSH: Adult · Female · Focus Groups · Health Status Indicators* · Humans · Male · Middle Aged · Quality of Life* · Sleep Apnea Syndromes* · Surveys and Questionnaires*

Card 2 — Measurement properties (Flemons 2002, American Journal of Respiratory and Critical Care Medicine — around a nasal CPAP trial): responsiveness index 1.9 and effect size 1.1, much greater than the SF-36 and FPQLI; test–retest reliability 0.92 at 2 weeks

Study: Measurement-properties study (programme; TYPE-FLAG: typed Clinical Trial at PubMed — a measurement study run around a CPAP trial, counted on substance)

Population: Patients with sleep apnea studied three times before and 4 weeks after a trial of nasal continuous positive airway pressure, completing the SF-36, the Ferrans and Powers Quality of Life Index and a global quality-of-life assessment alongside the SAQLI; the record states no sample size — N not documented, and none is printed.

Summary: Measurement properties (Flemons 2002, American Journal of Respiratory and Critical Care Medicine — around a nasal CPAP trial): responsiveness index 1.9 and effect size 1.1, much greater than the SF-36 and FPQLI; test–retest reliability 0.92 at 2 weeks

Result: The SAQLI had a very high responsiveness index of 1.9 and an effect size of 1.1, much greater than the domains of the SF-36 and the FPQLI. Longitudinal correlations with seven SF-36 domains ranged 0.24 to 0.54 in the predicted pattern. Baseline correlations ranged 0.36 to 0.71 with the SF-36, −0.26 with the Epworth Sleepiness Scale, 0.29 to 0.66 with the FPQLI and 0.61 with a global rating of quality of life. Test–retest reliability at 2 weeks was 0.92.

Watch out: TYPE-FLAG prints. The headline is responsiveness — an evaluative-instrument property measured around CPAP — and must never be read as evidence about CPAP's effectiveness. The missing sample size is a real gap in the record: the pack's strongest card is also its least countable.

Source: Flemons WW et al. Measurement properties of the calgary sleep apnea quality of life index. American journal of respiratory and critical care medicine. 2002. PMID: 11790647. Registry ID: none in the record. MeSH: Adult · Discriminant Analysis · Female · Health Status Indicators · Humans · Male · Middle Aged · Patient Compliance · Polysomnography · Positive-Pressure Respiration* · Quality of Life* · Reproducibility of Results · Severity of Illness Index · Sleep Apnea Syndromes/physiopathology,therapy* · Surveys and Questionnaires

Card 3 — Chinese (Cantonese) version (Mok 2004, Journal of Clinical Epidemiology — Hong Kong): consistency, validity and responsiveness good to excellent and more responsive than the SF-36, but factor analysis found only the daily-functioning and symptom domains' items all loading on their hypothesised scales

Study: Validation study (independent language transport)

Population: A cross-sectional sample of 106 Chinese patients with obstructive sleep apnea and a longitudinal sample of 51 patients in Hong Kong, completing the Chinese (Cantonese) SAQLI; the instrument was understood and seen as relevant by 97% of subjects.

Summary: Chinese (Cantonese) version (Mok 2004, Journal of Clinical Epidemiology — Hong Kong): consistency, validity and responsiveness good to excellent and more responsive than the SF-36, but factor analysis found only the daily-functioning and symptom domains' items all loading on their hypothesised scales

Result: Internal consistency, test–retest reliability, item-scale convergent validity and discriminatory validity, and construct validity were good to excellent, with construct validity confirmed by significant correlations with SF-36 subscale scores. However, factor analysis showed that only items of the daily-functioning and symptom domains all loaded on the hypothesised scales. Longitudinal data showed the SAQLI was more responsive than the SF-36 to changes after treatment.

Watch out: The factor limb prints at full weight beside the 'good to excellent' headline: in this transport, two of the four domains' internal structures were not confirmed as hypothesised. The record reports the consistency/validity findings as graded conclusions rather than coefficients, and none is printed from it.

Source: Mok WY et al. A Chinese version of the Sleep Apnea Quality of Life Index was evaluated for reliability, validity, and responsiveness. Journal of clinical epidemiology. 2004. PMID: 15196617. Registry ID: none in the record. MeSH: Adult · Cross-Cultural Comparison · Cross-Sectional Studies · Female · Health Status Indicators* · Hong Kong · Humans · Male · Middle Aged · Patient Acceptance of Health Care · Psychometrics · Quality of Life* · Reproducibility of Results · Sleep Apnea, Obstructive/ethnology*,psychology,rehabilitation · Socioeconomic Factors

Card 4 — Synthesis — an evaluative index whose proven strength is responsiveness; its derivation is unnumbered in the record and its four-domain structure was only half-confirmed in the Chinese transport

Study: Synthesis

Population: 3 reports carded: 1 programme development (113 patients + 50 snorers as item informants; no coefficients in its record), 1 programme measurement-properties study (N not documented in its record; TYPE-FLAG typed Clinical Trial) and 1 independent Chinese transport (106 cross-sectional + 51 longitudinal). No report was refused on this row.

Summary: Synthesis — an evaluative index whose proven strength is responsiveness; its derivation is unnumbered in the record and its four-domain structure was only half-confirmed in the Chinese transport

Result: The quantitative spine is one study: responsiveness index 1.9, effect size 1.1 and test–retest 0.92, with a convergent-correlation pattern (SF-36 0.36–0.71; global rating 0.61; ESS −0.26) in the predicted directions. The Chinese transport independently found the instrument acceptable, valid and more responsive than the SF-36, while its factor analysis confirmed only two of four domains. Stamp justification: MEASUREMENT PROPERTIES led by the responsiveness limb, with the coefficient-free derivation and the factor caveat inside the stamp — the shelf must not be read as four independently confirmed domain scores, nor as evidence about CPAP.

Watch out: Cross-points in prose only: the FOSQ (pack #8346) is the functional-outcomes neighbour across sleepiness disorders; the ESS (pack #8077) appears here only as a baseline comparator inside the measurement-properties anchor.

Source: Synthesis of the reports carded above; no additional source.