Vancouver Scar Scale: four reports — the incumbent's internal consistency was unacceptable (alpha 0.49) at its head-to-head, and its modified forms' reliability depends on which scar area is rated and fails at hypertrophic sites

Shelf #8362 · Eyes, skin, nose & allergy

MEASUREMENT PROPERTIES — weak and site-dependent as published: 4 reports (1 SHARED head-to-head derivation report, carded also on pack #8361 for its POSAS limb, 20 patients / 49 scar areas + 1 scar-volume construct study printing no coefficient or N + 2 modified-VSS reliability studies, N = 30 each); the original scale's internal consistency was 0.49 (not acceptable), total mVSS inter-rater ICC was only 0.65–0.73 in a scar's 'best' area vs 0.85–0.88 in its 'worst', and mVSS intrarater ICC was acceptable (0.81) for normal scar but below the acceptable range at hypertrophic-scar sites — a measurement-properties stamp, not a treatment stamp

Stamped: 2026-11-28.

Evidence published: 2000–2013.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

What are the measurement properties of the Vancouver Scar Scale (VSS — the observer-rated burn scar scale scoring pigmentation, vascularity, pliability and height) — how did it compare with the POSAS observer scale at its head-to-head, how valid is it against scar volume over time, and how reliable are its modified (mVSS) forms between and within raters?

Balance of the evidence

Report composition prints: 4 counted reports — 1 shared head-to-head report (PMID 15253184, the POSAS development study, carded here for its Vancouver limb) + 1 construct-validity study against scar volume (PMID 10850901, whose record prints no coefficient and no scar N) + 2 modified-VSS (mVSS) reliability studies (PMIDs 23433706 and 18388577, N = 30 each). SHARED REPORT, printed as shared on both faces (coordinator adjudication, slate 35): PMID 15253184 is carded on pack #8361 for its POSAS limb and here for its VSS limb — a different limb of the same report on each pack. This pack's headline is weakness in the incumbent, printed at full weight: unacceptable internal consistency in the head-to-head, reliability that depends on which part of the scar is rated, and sub-acceptable intrarater reliability exactly where it matters (hypertrophic scar). Two of the four anchors rate MODIFIED (mVSS) forms, printed as modified wherever their figures are used — no card presents mVSS figures as properties of the original VSS. The instrumental limbs of PMID 18388577 (Cutometer, Mexameter, DermaScan C) are comparator limbs, not rowed instruments. Pack hits for the VSS as an outcome inside burn/scar intervention packs (#1270, #4049, #6939, #6941) are uses, discharged at question level.

MeSH: Adolescent · Adult · Aged · Attitude to Health · Burns/complications* · Cicatrix/classification*,etiology,pathology · Humans · Linear Models · Middle Aged · Observer Variation · Patients · Reproducibility of Results · Surveys and Questionnaires* · Cicatrix, Hypertrophic/classification*,etiology · Reference Values · Severity of Illness Index · Analysis of Variance · Cicatrix, Hypertrophic/classification*,diagnosis,etiology · Female · Male · Prospective Studies · Burns/complications,physiopathology*,surgery · Cicatrix, Hypertrophic/physiopathology* · Health Status Indicators · ROC Curve · Sensitivity and Specificity · Software · Wound Healing*

Cards (5)

Card 1 — Head-to-head inside the POSAS development study (Draaijers 2004, Plastic and Reconstructive Surgery — the VSS limb): internal consistency alpha 0.49, NOT acceptable; single-observer reliability r = 0.69; coefficient of variation 22%

Study: Validation study (primary report) — SHARED REPORT: carded also on pack #8361 for its POSAS limb, printed as shared on both faces

Population: 20 patients with 49 burn scar areas of 3 × 3 cm, each rated by four independent observers with the Vancouver Scar Scale and the POSAS observer scale, as the record states

Summary: Head-to-head inside the POSAS development study (Draaijers 2004, Plastic and Reconstructive Surgery — the VSS limb): internal consistency alpha 0.49, NOT acceptable; single-observer reliability r = 0.69; coefficient of variation 22%

Result: The Vancouver scale's internal consistency appeared not to be acceptable (Cronbach's alpha 0.49), against 0.76 for the POSAS patient scale and 0.69 for the POSAS observer scale in the same study. The reliability of the Vancouver scale completed by a single observer was r = 0.69 (observer scale 0.73), and its coefficient of variation was higher (22% vs 18%), i.e. worse agreement. The POSAS observer scale's concurrent validity was tested against the Vancouver scale (r = 0.89, p < 0.001) — the incumbent served as the reference standard for the challenger that outperformed it on consistency.

Watch out: This is the developing (POSAS) group's own study, so the head-to-head was run by the challenger's programme — printed as such; the 0.49 figure is nonetheless the record's own published value for the VSS. Rated unit is the scar area (49) in 20 patients, never 49 patients.

Source: Draaijers LJ et al. The patient and observer scar assessment scale: a reliable and feasible tool for scar evaluation. Plastic and reconstructive surgery. 2004. PMID: 15253184. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Attitude to Health · Burns/complications* · Cicatrix/classification*,etiology,pathology · Humans · Linear Models · Middle Aged · Observer Variation · Patients · Reproducibility of Results · Surveys and Questionnaires*

Card 2 — Construct validity against scar volume (Nedelec 2000, Journal of Burn Care & Rehabilitation — scars followed monthly for at least 7 months): agreement, convergence, sensitivity to change and uncaptured parameters examined; proposed modifications — the record prints no coefficient and no scar N

Study: Construct-validity study (primary report)

Population: Burn scars evaluated monthly for a minimum of 7 months, with three scar-volume measurements and three independent VSS examiners per scar; N not documented in the record

Summary: Construct validity against scar volume (Nedelec 2000, Journal of Burn Care & Rehabilitation — scars followed monthly for at least 7 months): agreement, convergence, sensitivity to change and uncaptured parameters examined; proposed modifications — the record prints no coefficient and no scar N

Result: The data were used to establish (1) interrater agreement estimated by interclass correlation coefficient, (2) convergence validity against scar volume, (3) sensitivity of the assessments to discriminate changes in the scar over time, and (4) the prevalence of related parameters not currently captured by the VSS. The record prints no coefficient values and no number of scars, and none is printed here. The authors proposed several modifications to the scale, anticipating they would increase its reliability and validity, including through training in the scale's use.

Watch out: Coefficient-free record: this card supports the construct-validity programme qualitatively only. Any VSS–volume correlation quoted elsewhere does not come from this record and must not be printed from it.

Source: Nedelec B et al. Rating the resolving hypertrophic scar: comparison of the Vancouver Scar Scale and scar volume. The Journal of burn care & rehabilitation. 2000. PMID: 10850901. Registry ID: none in the record. MeSH: Burns/complications* · Cicatrix, Hypertrophic/classification*,etiology · Humans · Observer Variation · Reference Values · Reproducibility of Results · Severity of Illness Index

Card 3 — Modified VSS linked with %TBSA (Gankande 2013, Burns — 30 burn-scar patients, three raters): total mVSS inter-rater ICC only 0.65–0.73 ('fair to good') in the scar's BEST area but 0.85–0.88 ('excellent') in its WORST area

Study: Reliability study (primary report) — modified VSS (mVSS-TBSA), printed as modified

Population: 30 patients with burn scars; three raters scored pigmentation, vascularity, pliability and height for the 'best' and 'worst' areas of each scar and allocated scar %TBSA to severity categories, as the record states

Summary: Modified VSS linked with %TBSA (Gankande 2013, Burns — 30 burn-scar patients, three raters): total mVSS inter-rater ICC only 0.65–0.73 ('fair to good') in the scar's BEST area but 0.85–0.88 ('excellent') in its WORST area

Result: Total mVSS scores showed 'fair to good' agreement (ICC 0.65–0.73) in the 'best' area and 'excellent' agreement (ICC 0.85–0.88) in the 'worst' area. Individual-component weighted kappa ranged 0.44–0.84 (best) and 0.02–0.86 (worst). Determination of scar %TBSA had 'excellent' reliability (ICC 0.91–0.96). Misclassifications were observed for the total mVSS score in the 'worst' scar area and for %TBSA allocation in the lowest severity category, as published.

Watch out: These are MODIFIED-scale figures, not properties of the original VSS. Reliability is scar-area-dependent — the same raters agree well on the worst area and only fairly on the best — and component kappas fall as low as 0.02 in the worst area, so a total-score ICC must not be read onto the components.

Source: Gankande TU et al. A modified Vancouver Scar Scale linked with TBSA (mVSS-TBSA): Inter-rater reliability of an innovative burn scar assessment method. Burns : journal of the International Society for Burn Injuries. 2013. PMID: 23433706. Registry ID: none in the record. MeSH: Adult · Analysis of Variance · Burns/complications* · Cicatrix, Hypertrophic/classification*,diagnosis,etiology · Female · Humans · Male · Middle Aged · Observer Variation · Prospective Studies · Reproducibility of Results · Severity of Illness Index

Card 4 — Intrarater reliability of the mVSS against instrumental measures (Nedelec 2008, Journal of Burn Care & Research — 30 burn survivors, single investigator): mVSS total ICC acceptable (0.81) for normal scar but BELOW the acceptable range at hypertrophic-scar sites

Study: Validation study (primary report) — modified VSS (mVSS), printed as modified; the instrumental limbs are comparator limbs

Population: 30 burn survivors; a single investigator evaluated four tissue types (severe hypertrophic scar, less severe hypertrophic scar, donor-site normal scar, and normal skin) with the mVSS and three instruments, as the record states

Summary: Intrarater reliability of the mVSS against instrumental measures (Nedelec 2008, Journal of Burn Care & Research — 30 burn survivors, single investigator): mVSS total ICC acceptable (0.81) for normal scar but BELOW the acceptable range at hypertrophic-scar sites

Result: The intraclass correlation for the total of the height, pliability and vascularity subscales of the mVSS was acceptable (0.81) for normal (donor-site) scar but below the acceptable range for the hypertrophic-scar sites. By comparison, the DermaScan C total thickness measurement (ICC > 0.82 at all sites) clearly discriminated hypertrophic scar from normal scar and normal skin; the Cutometer discriminated less well and the Mexameter erythema index did not discriminate hypertrophic from normal scar. The best cut-off points were 2.034 mm (DermaScan C total thickness) and 0.387 mm (Cutometer maximum deformation).

Watch out: Single-investigator intrarater design — it says nothing about agreement between raters. The failure point is precise: the mVSS total is reliable on normal scar and unreliable on the hypertrophic scars it chiefly exists to grade.

Source: Nedelec B et al. Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity. Journal of burn care & research : official publication of the American Burn Association. 2008. PMID: 18388577. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Burns/complications,physiopathology*,surgery · Cicatrix, Hypertrophic/physiopathology* · Female · Health Status Indicators · Humans · Male · Middle Aged · Observer Variation · ROC Curve · Reproducibility of Results · Sensitivity and Specificity · Software · Wound Healing*

Card 5 — Synthesis — VSS: the incumbent scale's published record is weak where it matters — unacceptable consistency, area-dependent agreement, and sub-acceptable reliability at hypertrophic sites

Study: Synthesis

Population: 4 counted reports: shared head-to-head 20 patients / 49 scar areas; scar-volume construct study (N not documented); mVSS-TBSA N = 30; mVSS intrarater N = 30. Original-scale and modified-scale figures are never merged

Summary: Synthesis — VSS: the incumbent scale's published record is weak where it matters — unacceptable consistency, area-dependent agreement, and sub-acceptable reliability at hypertrophic sites

Result: The original VSS's only counted head-to-head gives internal consistency 0.49 (not acceptable) and single-observer reliability 0.69; its construct-validity study against scar volume prints no coefficient to quote. The modified forms improve some figures (%TBSA ICC 0.91–0.96; worst-area total ICC 0.85–0.88) but remain area-dependent (best-area total 0.65–0.73; component kappa down to 0.02) and the mVSS total falls below acceptable intrarater reliability at hypertrophic-scar sites (acceptable 0.81 only for normal scar). The shared derivation (PMID 15253184) prints as shared on this pack and on pack #8361. The stamp is MEASUREMENT PROPERTIES — weak and site-dependent as published.

Watch out: Do not cite mVSS reliability as the original VSS's, do not quote a VSS–volume coefficient from the 2000 record (it prints none), and expect the weakest performance exactly on hypertrophic scars.

Source: Synthesis of the reports carded above; no additional source.