PRWE patient-rated wrist evaluation: three reports — development with test–retest ICCs above 0.90 in fracture patients, and a Dutch–German measurement-error limb putting the change needed to exceed noise at 20 to about 22.5 points on a 100-point scale
Shelf #8366 · Bones & joints
MEASUREMENT PROPERTIES — reliable and valid at group level, with a wide individual-patient error band: 3 reports (1 programme derivation + 2 independent validations); test–retest ICCs were above 0.90 at derivation, and alpha 0.96 with ICC 0.87 in the Dutch fracture validation — but two independent studies put the change needed to exceed measurement error at 20 points (smallest detectable change) and approximately 22.5 points (MDC95) on the 100-point scale, so individual-patient change below that band is within noise — a measurement-properties stamp, not a treatment stamp
Stamped: 2026-11-28.
Evidence published: 1998–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
What are the measurement properties of the PRWE (Patient-Rated Wrist Evaluation — 15 items: 5 on pain, 10 on function, scored to 100) — what did its development establish in distal-radius and scaphoid fracture patients, and what validity, reliability and measurement error did the Dutch distal-radius-fracture study and the German version find?
Balance of the evidence
Report composition prints: 3 reports — 1 programme derivation (PMID 9840793, the MacDermid group's own report, programme-labelled) + 2 independent validations (Dutch PMID 29330342; German PMID 19210869). Shared report, printed as shared: PMID 29330342 is carded here for its PRWE limb; its DASH limb is recorded as corroboration on the DASH pack #8365, where it is not counted. Recorded as corroboration, not counted: the French version (PMID 13679744, 2003 — evaluated in 20 patients for comprehension, a preliminary feasibility report with no coefficients of its own). No other report was refused on this row; no anchor is retracted, abstract-only or fenced.
MeSH: Activities of Daily Living · Carpal Bones/injuries* · Fractures, Closed* · Humans · Outcome Assessment, Health Care* · Pain Measurement* · Radius Fractures* · Reproducibility of Results · Wrist Injuries* · Aged · Carpometacarpal Joints/physiopathology · Cross-Cultural Comparison · Female · Germany · Language · Male · Middle Aged · Osteoarthritis/physiopathology*,psychology* · Psychometrics/standards* · Surveys and Questionnaires/standards* · Wrist Joint/physiopathology*
Cards (4)
Card 1 — Development (MacDermid 1998, Journal of Orthopaedic Trauma — items generated from a survey of 100 International Wrist Investigators, biomechanical literature and patient interviews; reliability study in 64 distal-radius and 35 scaphoid fracture patients, validity study in 101 distal-radius patients against the SF-36 and impairment measures at baseline and 2, 3 and 6 months): test–retest ICCs above 0.90, significant change over time (p < 0.01) and appropriate correlations with alternate pain/disability measures
Study: Development study (primary report) — programme derivation
Population: Patients with distal radius (n = 64) or scaphoid (n = 35) fractures in the reliability study, and 101 patients with distal radius fractures in the validity study; 100 members of the International Wrist Investigators were surveyed for item generation. Programme-labelled: the MacDermid group's own report.
Summary: Development (MacDermid 1998, Journal of Orthopaedic Trauma — items generated from a survey of 100 International Wrist Investigators, biomechanical literature and patient interviews; reliability study in 64 distal-radius and 35 scaphoid fracture patients, validity study in 101 distal-radius patients against the SF-36 and impairment measures at baseline and 2, 3 and 6 months): test–retest ICCs above 0.90, significant change over time (p < 0.01) and appropriate correlations with alternate pain/disability measures
Result: Patient opinions on pain and on ability to do activities of daily living and work were thought to be the most important dimensions to include; brevity and simplicity were seen as essential. A fifteen-item questionnaire (the PRWE) was designed to measure wrist pain and disability. Test-retest reliability was excellent (ICCs > 0.90). Validity assessment demonstrated that the instrument detected significant differences over time (p < 0.01) and was appropriately correlated with alternate forms of assessing parameters of pain and disability, as published. The abstract prints no numeric validity correlation.
Watch out: A fracture-population derivation: its reliability was established in distal-radius and scaphoid fracture patients in one upper-extremity unit, and 'appropriately correlated' is the abstract's summary — no validity coefficient may be printed from this card. Measurement error was not quantified at derivation; the error figures come from the two later cards.
Source: MacDermid et al. Patient rating of wrist pain and disability: a reliable and valid measurement tool. Journal of orthopaedic trauma. 1998. PMID: 9840793. Registry ID: none in the record. MeSH: Activities of Daily Living · Carpal Bones/injuries* · Fractures, Closed* · Humans · Outcome Assessment, Health Care* · Pain Measurement* · Radius Fractures* · Reproducibility of Results · Wrist Injuries*
Card 2 — Dutch validation (Kleinlugtenbelt 2018, Bone & Joint Research — 119 patients (mean age 58, 74% female) with displaced distal radial fracture): one overall dimension found for the PRWE, Cronbach alpha 0.96, test–retest ICC 0.87, smallest detectable change 20 points, no floor/ceiling effects and good content validity — the authors concluding that despite validity and reliability the high SDC makes the PRWE (and the DASH, SDC 14) less useful for individual patients (shared report: its DASH limb is corroboration on pack #8365)
Study: Validation study (primary report) — shared report (PRWE limb carded here; DASH limb on pack #8365 as corroboration)
Population: 119 Dutch patients with a displaced distal radial fracture (mean age 58 years (SD 15), 74% female), completing the PRWE and DASH twice at a mean of six months post-fracture with a two-week interval, plus semi-structured content-validity interviews at 8–12 weeks. Shared report, printed as shared.
Summary: Dutch validation (Kleinlugtenbelt 2018, Bone & Joint Research — 119 patients (mean age 58, 74% female) with displaced distal radial fracture): one overall dimension found for the PRWE, Cronbach alpha 0.96, test–retest ICC 0.87, smallest detectable change 20 points, no floor/ceiling effects and good content validity — the authors concluding that despite validity and reliability the high SDC makes the PRWE (and the DASH, SDC 14) less useful for individual patients (shared report: its DASH limb is corroboration on pack #8365)
Result: One overall meaningful dimension was found for the PRWE and the DASH. Internal consistency was excellent for both (Cronbach's α 0.96 (PRWE) and 0.97 (DASH)). Test-retest reliability was good for the PRWE (ICC 0.87) and excellent for the DASH (ICC 0.91). The smallest detectable change was 20 for the PRWE and 14 for the DASH. No floor or ceiling effects were found, and content validity was good for both questionnaires. The authors conclude that due to the high SDC, the PRWE and DASH are less useful for individual patients with a distal radial fracture in clinical practice, as published.
Watch out: The load-bearing caveat of this pack: an SDC of 20 on a 0–100 scale means an individual patient's PRWE must move by more than a fifth of the scale before the change exceeds measurement error. The study is Dutch, single-fracture-type and assessed at about six months post-fracture; its error figure may not transfer to other wrist conditions or time points.
Source: Kleinlugtenbelt et al. Are the patient-rated wrist evaluation (PRWE) and the disabilities of the arm, shoulder and hand (DASH) questionnaire used in distal radial fractures truly valid and reliable? Bone & joint research. 2018. PMID: 29330342. Registry ID: none in the record. MeSH: none in the record
Card 3 — German version (John 2008, Clinical and Experimental Rheumatology — PRWE-G in 103 patients 6.2 years after resection-interposition arthroplasty for carpometacarpal osteoarthritis, 51 re-tested within 2 weeks): test–retest ICCs 0.78–0.87 across subscales and total, Cronbach alphas 0.92–0.97, typical error 8.1 points giving an MDC95 of approximately 22.5 points, correlation with the DASH r = 0.82 (p < 0.001), with the SF-36 physical component r = 0.53 and not at all with its mental component (r = 0.04)
Study: Validation study (primary report) — German language version
Population: 103 German-speaking patients who had undergone resection interposition arthroplasty for carpometacarpal (thumb-base) osteoarthritis approximately 6.2 years earlier, completing the PRWE-G, SF-36 and DASH with clinical hand-function assessment; 51 completed a second PRWE-G within 2 weeks for retest reliability.
Summary: German version (John 2008, Clinical and Experimental Rheumatology — PRWE-G in 103 patients 6.2 years after resection-interposition arthroplasty for carpometacarpal osteoarthritis, 51 re-tested within 2 weeks): test–retest ICCs 0.78–0.87 across subscales and total, Cronbach alphas 0.92–0.97, typical error 8.1 points giving an MDC95 of approximately 22.5 points, correlation with the DASH r = 0.82 (p < 0.001), with the SF-36 physical component r = 0.53 and not at all with its mental component (r = 0.04)
Result: Test-retest reliability was acceptable for the pain and function subscales and the global score, with intraclass correlation coefficients of 0.78–0.87. Internal consistency was high (Cronbach's alphas 0.92–0.97). The typical error of measurement for the global score was 8.1 points, giving a minimal detectable change (MDC95) of approximately 22.5 points. PRWE-G scores correlated well with the DASH (r = 0.82, p < 0.001), less well with the SF-36 physical component summary (r = 0.53, p < 0.001) and not at all with its mental component summary (r = 0.04, p > 0.05), and moderately with clinical hand-function and grip/pinch measures (r = 0.30–0.59, p < 0.001), as published.
Watch out: The population differs from the other anchors — thumb-base osteoarthritis six years after arthroplasty, not wrist fracture — and its MDC95 of ~22.5 points independently corroborates the Dutch SDC of 20 in a different condition and language. The null correlation with the SF-36 mental component (r = 0.04) is discriminant evidence in the instrument's favour, printed as such, not as a failure.
Source: John et al. The patient-rated wrist evaluation (PRWE): cross-cultural adaptation into German and evaluation of its psychometric properties. Clinical and experimental rheumatology. 2008. PMID: 19210869. Registry ID: none in the record. MeSH: Aged · Carpometacarpal Joints/physiopathology · Cross-Cultural Comparison · Female · Germany · Humans · Language · Male · Middle Aged · Osteoarthritis/physiopathology*,psychology* · Psychometrics/standards* · Reproducibility of Results · Surveys and Questionnaires/standards* · Wrist Joint/physiopathology*
Card 4 — Synthesis (3 reports: 1 programme derivation + 2 independent validations): the PRWE is reliable and valid for group-level wrist outcome, and two independent studies agree that roughly 20–22.5 points of change are needed before an individual patient's change exceeds measurement error
Study: Synthesis
Population: Synthesis of the 3 reports carded above: the derivation (reliability 64 + 35 fracture patients; validity 101), the Dutch validation (119) and the German validation (103, 51 re-tested). Corroboration not counted: the French feasibility report (PMID 13679744, 20 patients, no coefficients of its own).
Summary: Synthesis (3 reports: 1 programme derivation + 2 independent validations): the PRWE is reliable and valid for group-level wrist outcome, and two independent studies agree that roughly 20–22.5 points of change are needed before an individual patient's change exceeds measurement error
Result: Derivation test–retest ICCs were above 0.90 with significant change over time (p < 0.01); the Dutch study found one overall dimension, alpha 0.96, ICC 0.87 and a smallest detectable change of 20 points; the German version found ICCs 0.78–0.87, alphas 0.92–0.97, a typical error of 8.1 points (MDC95 ≈ 22.5) and a DASH correlation of 0.82 with no mental-component correlation (0.04).
Watch out: Never interpret an individual PRWE change under ~20 points as real change on this evidence — that is the pack's headline, not a footnote. Cross-point in prose only: the DASH (pack #8365) is the region-level instrument validated head-to-head in the Dutch report; the BCTQ (pack #8367) is the carpal-tunnel-specific neighbour.