Bedside chest ultrasonography for pneumothorax — summary sensitivity 0.91 against supine chest radiography's 0.47 in the Cochrane trauma review, with the wider syntheses pooling ultrasonography sensitivity lower (0.88 and 78.6%) and specificity marginally below radiography's in every pool; 4 overlapping syntheses, no primary report
Shelf #8414 · Emergency & first hours
PREDICTIVE PERFORMANCE — ultrasonography is far more sensitive than supine radiography, with specificity marginally lower, on four overlapping syntheses and no primary report: Cochrane trauma primary analysis (9 studies, 410 pneumothorax patients of 1,271) gave chest ultrasonography by frontline non-radiologist physicians summary sensitivity 0.91 (95% CI 0.85–0.94) and specificity 0.99 (0.97–1.00) against supine radiography 0.47 (0.31–0.63) / 1.00 (0.97–1.00) — an absolute sensitivity difference of 0.44 (0.27–0.61) — with all studies at high or unclear risk of bias in at least one domain; the wider pools put ultrasonography sensitivity lower (0.88 in 2011; 78.6% (68.1–98.1) in 2013) and the trauma sign-level pool at 0.81 (0.71–0.88) for absent lung sliding/comet-tail artefacts, so pooled sensitivity itself disagrees across syntheses (0.79–0.91) and the disagreement, driven by sampling frame and operator, prints at weight; the comparator throughout is supine/plain radiography, not CT
Stamped: 2026-11-28.
Evidence published: 2011–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In emergency and acute-care patients, how accurately does bedside lung/chest ultrasonography detect pneumothorax against CT (or thoracostomy) compared with supine chest radiography — in the Cochrane paired-accuracy review in trauma, in the two general meta-analyses, and in the trauma systematic review that also pooled haemothorax?
Balance of the evidence
4 reports, all syntheses, no primary report: Chan 2020 (Cochrane, 13 paired trauma studies), Ding 2011 (meta-analysis across settings), Alrajab 2013 (13 studies meeting strict criteria) and Staub 2018 (19 prospective adult-trauma studies; 17 pneumothorax, 5 haemothorax). THE POOLS OVERLAP — the Cochrane trauma pool sits inside the wider meta-analyses — so no figure here is four independent confirmations, and pools print by synthesis, never merged. No report was refused. The haemothorax limb of Staub 2018 (sensitivity 0.60 (0.31–0.86), specificity 0.98, from 5 studies) prints as a secondary limb only. Cross-points in prose only: lung ultrasound for pneumonia is homed at pack #3875 and diaphragm/lung ultrasound for weaning prediction at pack #3131 — different questions.
MeSH: Bias · Confidence Intervals · Emergency Service, Hospital · Humans · Pneumothorax/diagnostic imaging*,etiology · Prospective Studies · Radiography, Thoracic/methods* · Sensitivity and Specificity · Supine Position* · Thoracic Injuries/complications* · Ultrasonography/methods* · Wounds, Nonpenetrating/complications · Wounds, Penetrating/complications · Pneumothorax/diagnostic imaging* · ROC Curve · Radiography, Thoracic · Ultrasonography · Radiography, Thoracic/standards · Hemothorax/diagnostic imaging*,etiology · Reproducibility of Results · Thoracic Injuries/complications*,diagnostic imaging · Ultrasonography*
Cards (5)
Card 1 — Cochrane paired-accuracy review in trauma (Chan 2020, Cochrane Database of Systematic Reviews — 13 paired studies; primary analysis 9 studies / 410 pneumothorax patients of 1,271): ultrasonography sensitivity 0.91 (95% CI 0.85–0.94), specificity 0.99 (0.97–1.00); supine radiography 0.47 (0.31–0.63) / 1.00 (0.97–1.00); absolute sensitivity difference 0.44 (0.27–0.61)
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)
Population: Trauma patients in the emergency department suspected of pneumothorax; index test chest ultrasonography by frontline non-radiologist physicians, comparator supine chest radiography, reference standard CT of the chest or tube thoracostomy. Primary analysis: 9 studies using patients as the unit of analysis (410 traumatic pneumothorax patients out of 1,271 patients); 4 further studies used lung fields and entered the secondary analysis only.
Summary: Cochrane paired-accuracy review in trauma (Chan 2020, Cochrane Database of Systematic Reviews — 13 paired studies; primary analysis 9 studies / 410 pneumothorax patients of 1,271): ultrasonography sensitivity 0.91 (95% CI 0.85–0.94), specificity 0.99 (0.97–1.00); supine radiography 0.47 (0.31–0.63) / 1.00 (0.97–1.00); absolute sensitivity difference 0.44 (0.27–0.61)
Result: Summary sensitivity and specificity of chest ultrasonography were 0.91 (95% CI 0.85–0.94) and 0.99 (0.97–1.00); of supine chest radiography, 0.47 (0.31–0.63) and 1.00 (0.97–1.00). The absolute difference in sensitivity was 0.44 (0.27–0.61; P < 0.001); the absolute difference in specificity was −0.007 (−0.018 to 0.005, P = 0.35). In a hypothetical cohort of 100 patients at 30% prevalence, ultrasonography would miss 3 cases and overdiagnose 1, radiography would miss 16 with 0 overdiagnosed, as published.
Watch out: All studies were judged at high or unclear risk of bias in one or more domains (85% in patient selection), and radiography sensitivity was substantially heterogeneous across studies.
Source: Chan et al. Chest ultrasonography versus supine chest radiography for diagnosis of pneumothorax in trauma patients in the emergency department. The Cochrane database of systematic reviews. 2020. PMID: 32702777. Registry ID: none in the record. MeSH: Bias · Confidence Intervals · Emergency Service, Hospital · Humans · Pneumothorax/diagnostic imaging*,etiology · Prospective Studies · Radiography, Thoracic/methods* · Sensitivity and Specificity · Supine Position* · Thoracic Injuries/complications* · Ultrasonography/methods* · Wounds, Nonpenetrating/complications · Wounds, Penetrating/complications
Card 2 — General meta-analysis (Ding 2011, Chest — across settings): ultrasonography pooled sensitivity 0.88 / specificity 0.99 against radiography 0.52 / 1.00; non-radiologist ultrasonography 0.89 / 0.99; operator strongly associated with accuracy (relative diagnostic odds ratio 0.21 (0.05–0.96))
Study: Meta-analysis (synthesis, counted as a synthesis)
Population: Patients in eligible English-language studies comparing anterior-posterior chest radiography with transthoracic ultrasonography for pneumothorax diagnosis, across settings; the record states no pooled patient total in its abstract.
Summary: General meta-analysis (Ding 2011, Chest — across settings): ultrasonography pooled sensitivity 0.88 / specificity 0.99 against radiography 0.52 / 1.00; non-radiologist ultrasonography 0.89 / 0.99; operator strongly associated with accuracy (relative diagnostic odds ratio 0.21 (0.05–0.96))
Result: Pooled sensitivity and specificity were 0.88 and 0.99 for ultrasonography and 0.52 and 1.00 for radiography. For ultrasonography performed by clinicians other than radiologists, pooled sensitivity and specificity were 0.89 and 0.99. Meta-regression implied the operator is strongly associated with accuracy (relative diagnostic odds ratio, labelled relative, 0.21; 95% CI 0.05–0.96; P = .0455), and the summary ROC areas did not differ significantly between the two modalities, as published.
Watch out: The sROC areas did not differ significantly even though the pooled sensitivity did — the headline pair and the curve comparison are different summaries of the same pool and both print.
Source: Ding et al. Diagnosis of pneumothorax by radiography and ultrasonography: a meta-analysis. Chest. 2011. PMID: 21546439. Registry ID: none in the record. MeSH: Humans · Pneumothorax/diagnostic imaging* · ROC Curve · Radiography, Thoracic · Sensitivity and Specificity · Ultrasonography
Card 3 — General meta-analysis with strict criteria (Alrajab 2013, Critical Care — 13 studies): ultrasonography pooled sensitivity 78.6% (95% CI 68.1–98.1), specificity 98.4% (97.3–99.5); radiography 39.8% (29.4–50.3) / 99.3% (98.4–100)
Study: Meta-analysis (synthesis, counted as a synthesis)
Population: Patients in 13 articles meeting all inclusion criteria out of 601 reviewed (25 taken to detailed review); one study used lung sliding alone, 12 used lung sliding and comet-tail signs, and 6 also searched for the lung point.
Summary: General meta-analysis with strict criteria (Alrajab 2013, Critical Care — 13 studies): ultrasonography pooled sensitivity 78.6% (95% CI 68.1–98.1), specificity 98.4% (97.3–99.5); radiography 39.8% (29.4–50.3) / 99.3% (98.4–100)
Result: Ultrasonography had a pooled sensitivity of 78.6% (95% CI 68.1–98.1) and specificity of 98.4% (97.3–99.5); chest radiography had a pooled sensitivity of 39.8% (29.4–50.3) and specificity of 99.3% (98.4–100). Consecutive versus convenience sampling and trauma versus non-trauma setting were significant sources of heterogeneity, and subgroup analysis showed significant variation by operator and probe type, as published.
Watch out: This pool's ultrasonography sensitivity (78.6%) sits well below the Cochrane trauma figure (0.91) — sampling frame and setting drive the gap, so the two pools must never be averaged into one number.
Source: Alrajab et al. Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis. Critical care (London, England). 2013. PMID: 24060427. Registry ID: none in the record. MeSH: Humans · Pneumothorax/diagnostic imaging* · Radiography, Thoracic/standards · Ultrasonography
Card 4 — Trauma sign-level synthesis (Staub 2018, Injury — 19 prospective adult-trauma studies, reference standard CT; 17 pneumothorax, 5 haemothorax): absent lung sliding/comet-tail artefacts sensitivity 0.81 (0.71–0.88), specificity 0.98 (0.97–0.99), positive LR 67.9 (26.3–148), negative LR 0.18 (0.11–0.29), AUC 0.979; haemothorax limb sensitivity 0.60 (0.31–0.86), specificity 0.98
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)
Population: Adults with trauma in 19 prospective studies (17 assessing pneumothorax, 5 haemothorax); the reference standard was always chest tomography, alone or in parallel with chest radiography and observation of the chest tube. The review was previously registered (PROSPERO CRD42016048085, printed in the abstract).
Summary: Trauma sign-level synthesis (Staub 2018, Injury — 19 prospective adult-trauma studies, reference standard CT; 17 pneumothorax, 5 haemothorax): absent lung sliding/comet-tail artefacts sensitivity 0.81 (0.71–0.88), specificity 0.98 (0.97–0.99), positive LR 67.9 (26.3–148), negative LR 0.18 (0.11–0.29), AUC 0.979; haemothorax limb sensitivity 0.60 (0.31–0.86), specificity 0.98
Result: For pneumothorax, the absence of lung sliding and comet-tail artefacts — the most reported sonographic sign — had sensitivity 0.81 (95% CI 0.71–0.88), specificity 0.98 (0.97–0.99), positive likelihood ratio 67.9 (26.3–148) and negative LR 0.18 (0.11–0.29); overall chest-ultrasonography AUC was 0.979. For haemothorax (secondary limb), an echo-poor or anechoic pleural area had sensitivity 0.60 (0.31–0.86), specificity 0.98 (0.94–0.99), positive LR 37.5 (5.26–207.5), negative LR 0.40 (0.17–0.72) and AUC 0.953, as published.
Watch out: Overall methodological quality of the included studies was rated low by the authors, and the haemothorax pair rests on only 5 studies with a very wide sensitivity interval — a secondary limb, never the headline.
Source: Staub et al. Chest ultrasonography for the emergency diagnosis of traumatic pneumothorax and haemothorax: A systematic review and meta-analysis. Injury. 2018. PMID: 29433802. Registry ID: none in the record. MeSH: Emergency Service, Hospital · Hemothorax/diagnostic imaging*,etiology · Humans · Pneumothorax/diagnostic imaging*,etiology · Prospective Studies · Reproducibility of Results · Thoracic Injuries/complications*,diagnostic imaging · Ultrasonography*
Card 5 — Synthesis: bedside ultrasonography detects pneumothorax far more sensitively than supine radiography (pooled sensitivity 0.79–0.91 across syntheses against radiography's 0.40–0.52) at a small specificity cost (0.98–0.99 against 0.99–1.00) — on 4 overlapping syntheses and no primary report
Study: Synthesis
Population: Pools as carded: Cochrane trauma 1,271 patients (primary analysis); Ding across settings (total not stated in the record); Alrajab 13 strict-criteria studies; Staub 19 prospective trauma studies. The pools share primary studies and are never merged.
Summary: Synthesis: bedside ultrasonography detects pneumothorax far more sensitively than supine radiography (pooled sensitivity 0.79–0.91 across syntheses against radiography's 0.40–0.52) at a small specificity cost (0.98–0.99 against 0.99–1.00) — on 4 overlapping syntheses and no primary report
Result: Ultrasonography sensitivity by pool: 0.91 (Cochrane trauma), 0.88 (Ding), 78.6% (Alrajab), 0.81 for the absent-sliding sign (Staub). Radiography sensitivity by pool: 0.47, 0.52, 39.8%. Specificity: ultrasonography 0.98–0.99, radiography 0.99–1.00 — ultrasonography is marginally the less specific test in every pool. Operator and sampling frame are the named drivers of the spread. Haemothorax (secondary limb, 5 studies): 0.60 / 0.98. No report was refused. Cross-points in prose only: packs #3875 (lung ultrasound for pneumonia) and #3131 (weaning prediction). The stamp is PREDICTIVE PERFORMANCE with the overlap and the sensitivity disagreement on its face.
Watch out: Never quote a single 'ultrasound sensitivity for pneumothorax' without naming its pool — the syntheses disagree by more than ten points — and never present these four syntheses as four independent confirmations.
Source: Synthesis of the reports carded above; no additional source.