SourceMed · Shelf #8415 in the ask interface
Point-of-care ultrasonography for pleural effusion — sensitivity 94.54% and specificity 97.88% against radiography's 67.68% / 85.30% in the 2024 head-to-head meta-analysis, 93% / 96% against CT or drainage in the 2010 review, and 0.94 / 0.98 in the 2016 pool with extreme heterogeneity; 3 overlapping syntheses
Shelf #8415 · Lungs, breathing & sleep
PREDICTIVE PERFORMANCE — ultrasonography is consistently the more accurate test across three overlapping syntheses, with the reference standards differing between pools: the 2024 head-to-head meta-analysis (18 studies; TYPE-FLAG: typed Review only) gave point-of-care ultrasound sensitivity 94.54% (95% CI 91.74–97.34) and specificity 97.88% (95.77–99.99) against chest radiography 67.68% (58.29–77.08) / 85.30% (80.06–90.54), accuracy remaining high with less-trained operators; the 2010 review against CT or thoracic drainage (4 studies) gave sonography mean sensitivity 93% (89–96) and specificity 96% (95–98); the 2016 pool (12 studies / 1,554 subjects) gave ultrasonography 0.94 (0.88–0.97) / 0.98 (0.92–1.00) against radiography 0.51 (0.33–0.68) / 0.91 (0.68–0.98) with extreme heterogeneity (I² 84–93%) — the pairs are not estimates of the same quantity because their reference standards differ, and they print by synthesis, never merged
Stamped: 2026-11-28.
Evidence published: 2010–2024.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with suspected pleural effusion, how accurately does point-of-care / bedside ultrasonography detect pleural fluid against CT or drainage, compared with chest radiography — in the 2024 head-to-head meta-analysis, the Brazilian Cochrane-centre systematic review, and the 2016 screening-performance meta-analysis?
Balance of the evidence
3 reports, all syntheses: Zaki 2024 (18 studies; TYPE-FLAG typed Review only at PubMed although titled a systematic review and meta-analysis, counted on substance), Grimberg 2010 (Brazilian Cochrane Centre; 4 studies against CT or thoracic drainage) and Yousefifard 2016 (12 studies / 1,554 subjects). The syntheses overlap in primary studies and span 2010–2024 equipment generations. No report was refused. Cross-point in prose only: the pleural-effusion bedside-examination question is homed at pack #8266 — this pack is the device question, not the examination question.
MeSH: Humans · Pleural Effusion/diagnostic imaging* · Reproducibility of Results · Sensitivity and Specificity · Ultrasonography
Cards (4)
Card 1 — Head-to-head meta-analysis (Zaki 2024, The Ultrasound Journal — 18 studies; TYPE-FLAG: typed Review only at PubMed, counted on substance): point-of-care ultrasound sensitivity 94.54% (95% CI 91.74–97.34), specificity 97.88% (95.77–99.99); chest radiography 67.68% (58.29–77.08) / 85.30% (80.06–90.54)
Study: Systematic review and meta-analysis (synthesis, counted as a synthesis; TYPE-FLAG — typed Review only at PubMed)
Population: Patients in 18 eligible studies (of 1,642 articles found) comparing point-of-care ultrasound with chest radiography for pleural effusion; quality assessed with QUADAS-2. The record states no pooled patient total in its abstract.
Summary: Head-to-head meta-analysis (Zaki 2024, The Ultrasound Journal — 18 studies; TYPE-FLAG: typed Review only at PubMed, counted on substance): point-of-care ultrasound sensitivity 94.54% (95% CI 91.74–97.34), specificity 97.88% (95.77–99.99); chest radiography 67.68% (58.29–77.08) / 85.30% (80.06–90.54)
Result: Pooled point-of-care ultrasound sensitivity was 94.54% (95% CI 91.74–97.34) and specificity 97.88% (95.77–99.99), against radiography sensitivity 67.68% (58.29–77.08) and specificity 85.30% (80.06–90.54). Subgroup analysis: ultrasound in supine and upright positions had higher specificity (99%) than other positions; lateral decubitus radiography had higher sensitivity (96%) and specificity (99%) than other radiography positions; and accuracy remained high even when performed by physicians with less ultrasound training, as published.
Watch out: Position subgroups move both tests' figures substantially (lateral decubitus radiography reaches 96%/99%), so the headline pair describes the mixed-position pool, not every bedside protocol.
Source: Zaki et al. Advancement in pleura effusion diagnosis: a systematic review and meta-analysis of point-of-care ultrasound versus radiographic thoracic imaging. The ultrasound journal. 2024. PMID: 38261109. Registry ID: none in the record. MeSH: none in the record
Card 2 — Brazilian Cochrane-centre review (Grimberg 2010, São Paulo Medical Journal — 4 studies against CT or thoracic drainage): sonography mean sensitivity 93% (95% CI 89–96), specificity 96% (95–98)
Study: Systematic review with meta-analysis (synthesis, counted as a synthesis)
Population: Patients in 4 studies in which sonography for pleural effusion was tested against an acceptable reference standard — computed tomography or thoracic drainage. The record states no pooled patient total in its abstract.
Summary: Brazilian Cochrane-centre review (Grimberg 2010, São Paulo Medical Journal — 4 studies against CT or thoracic drainage): sonography mean sensitivity 93% (95% CI 89–96), specificity 96% (95–98)
Result: All four studies showed sonography had high sensitivity, specificity and accuracy for detecting pleural effusions; the mean sensitivity was 93% (95% CI 89% to 96%) and specificity was 96% (95% CI 95% to 98%), in different populations and clinical settings, as published.
Watch out: Only 4 studies, and this is the one pool whose reference standard is CT/drainage rather than a radiography-comparator design — its 93%/96% pair is not the same quantity as the other pools' pairs.
Source: Grimberg et al. Diagnostic accuracy of sonography for pleural effusion: systematic review. Sao Paulo medical journal = Revista paulista de medicina. 2010. PMID: 20676576. Registry ID: none in the record. MeSH: Humans · Pleural Effusion/diagnostic imaging* · Reproducibility of Results · Sensitivity and Specificity · Ultrasonography
Card 3 — Screening-performance meta-analysis (Yousefifard 2016, Emergency (Tehran) — 12 studies / 1,554 subjects): ultrasonography pooled sensitivity 0.94 (0.88–0.97), specificity 0.98 (0.92–1.00); radiography 0.51 (0.33–0.68) / 0.91 (0.68–0.98); heterogeneity I² 84–93%
Study: Meta-analysis (synthesis, counted as a synthesis)
Population: 1,554 subjects (58.6% male) in 12 studies of ultrasonography and radiography for detection of pleural effusion.
Summary: Screening-performance meta-analysis (Yousefifard 2016, Emergency (Tehran) — 12 studies / 1,554 subjects): ultrasonography pooled sensitivity 0.94 (0.88–0.97), specificity 0.98 (0.92–1.00); radiography 0.51 (0.33–0.68) / 0.91 (0.68–0.98); heterogeneity I² 84–93%
Result: Pooled sensitivity of ultrasonography was 0.94 (95% CI 0.88–0.97; I² = 84.23) and pooled specificity 0.98 (0.92–1.0; I² = 88.65), while radiography sensitivity was 0.51 (0.33–0.68; I² = 91.76) and specificity 0.91 (0.68–0.98; I² = 92.86). Ultrasonography sensitivity was higher when performed by an intensivist or a radiologist and with 5–10 MHz transducers, as published.
Watch out: Heterogeneity is extreme in every limb (I² 84–93%) — the pooled pairs are averages over materially different studies, and the operator/probe subgroup finding means the pool's 0.94 is not every operator's figure.
Source: Yousefifard et al. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis. Emergency (Tehran, Iran). 2016. PMID: 26862542. Registry ID: none in the record. MeSH: none in the record
Card 4 — Synthesis: bedside ultrasonography detects pleural fluid with sensitivity ~0.93–0.95 and specificity ~0.96–0.98 across three overlapping syntheses, clearly above radiography in the two head-to-head pools — but the pools use different reference standards and one is extremely heterogeneous
Study: Synthesis
Population: Pools as carded: 18 studies (2024, total not stated in the record); 4 studies against CT/drainage (2010, total not stated in the record); 12 studies / 1,554 subjects (2016). Pools overlap and print separately.
Summary: Synthesis: bedside ultrasonography detects pleural fluid with sensitivity ~0.93–0.95 and specificity ~0.96–0.98 across three overlapping syntheses, clearly above radiography in the two head-to-head pools — but the pools use different reference standards and one is extremely heterogeneous
Result: Ultrasonography pairs by synthesis: 94.54% / 97.88% (2024, vs radiography 67.68% / 85.30%); 93% / 96% (2010, against CT or drainage); 0.94 / 0.98 (2016, vs radiography 0.51 / 0.91, I² 84–93%). No report was refused. Cross-point in prose only: pleural-effusion examination signs at pack #8266. The stamp is PREDICTIVE PERFORMANCE with the standard-difference and heterogeneity caveats on its face.
Watch out: Do not merge the three pairs into one 'ultrasound accuracy' figure: the 2010 pair is measured against CT/drainage and the others inside radiography-comparator designs, and the 2016 pool's heterogeneity is extreme.
Source: Synthesis of the reports carded above; no additional source.