SourceMed · Shelf #8416 in the ask interface

Inferior-vena-cava ultrasound for central venous pressure — pooled correlations are moderate (best r 0.68 for IVC diameter) and the synthesis's own verdict is that IVC measurement is NOT an acceptable surrogate for CVP; two small primaries in unlike populations (30 shock patients; 83 intubated patients) point the same correlational way; 1 synthesis + 2 primary studies

Shelf #8416 · Critical care & sepsis

PREDICTIVE PERFORMANCE — moderate correlations that the synthesis itself judges insufficient to stand in for CVP: the 37-paper / 2,843-case meta-analysis pooled correlation coefficients with catheter CVP of 0.68 for IVC diameter, 0.60 for inspiratory diameter, 0.54 for the collapsibility index and 0.44 for expiratory diameter, with no publication bias detected (P = 0.28) — AND the authors' own conclusion, printed here at full weight, that the study does not support IVC diameter measurement by ultrasonography as an acceptable surrogate for CVP; the two primaries are small and in unlike populations (30 emergency-department shock patients: caval index r = −0.721 two-dimensional / −0.647 M-mode; 83 intubated critically ill patients: inspiratory diameter r 0.1 as printed, collapsibility negatively correlated at unsigned r 0.68, P < 0.01) and must never be pooled; these are correlations, not sensitivity/specificity pairs, and no diagnostic pair may be manufactured from them

Stamped: 2026-11-28.

Evidence published: 1987–2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In critically ill and emergency patients, how well do bedside inferior-vena-cava ultrasound measurements — diameter, inspiratory/expiratory diameter and the collapsibility (caval) index — estimate central venous pressure measured by catheter or manometer?

Balance of the evidence

3 reports: 1 synthesis (Alavi-Moghaddam 2017, 37 papers / 2,843 cases) + 2 primary studies (Worapratya 2014, 30 shock patients with central catheters; Karacabey 2016, 83 intubated patients, CVP by U-tube manometer). The synthesis's unfavourable surrogacy verdict is this pack's honesty anchor and prints at full weight in the stamp, the synthesis card and here. No report was refused. Fluid-responsiveness prediction by IVC variation (a dynamic test against fluid challenge) is a different question and is not answered by these anchors.

MeSH: Central Venous Pressure/physiology* · Humans · Reproducibility of Results · Ultrasonography/methods* · Vena Cava, Inferior/diagnostic imaging*,physiopathology*

Cards (4)

Card 1 — Meta-analysis (Alavi-Moghaddam 2017, Acta Radiologica — 37 papers / 2,843 cases): correlations with CVP — IVC diameter 0.68, inspiratory diameter 0.60, collapsibility index 0.54, expiratory diameter 0.44; no publication bias (P = 0.28); AUTHORS' VERDICT: does NOT support IVC diameter by ultrasonography as an acceptable surrogate for CVP

Study: Systematic review and meta-analysis (synthesis, counted as a synthesis)

Population: 2,843 cases in 37 papers relating ultrasonographic inferior-vena-cava measurements to central venous pressure; quality assessed with the STROBE checklist, with meta-regression.

Summary: Meta-analysis (Alavi-Moghaddam 2017, Acta Radiologica — 37 papers / 2,843 cases): correlations with CVP — IVC diameter 0.68, inspiratory diameter 0.60, collapsibility index 0.54, expiratory diameter 0.44; no publication bias (P = 0.28); AUTHORS' VERDICT: does NOT support IVC diameter by ultrasonography as an acceptable surrogate for CVP

Result: The correlation coefficients between each of IVC diameter, inspiratory IVC, IVC collapsibility index and expiratory IVC with CVP were 0.68, 0.60, 0.54 and 0.44 respectively. There was no evidence of publication bias (P = 0.28); on meta-regression, male gender was an important source of heterogeneity (OR = 1.01; 95% CI 1–1.03), with higher correlations in men. The authors conclude: this study does not support the measurement of IVC diameter by ultrasonography as an acceptable surrogate variable to determine CVP among critical patients, as published.

Watch out: A correlation of 0.68 still leaves most of the variance in CVP unexplained — correlation is not surrogacy, which is exactly the authors' point; no sensitivity/specificity pair exists in this record and none may be derived from the correlations.

Source: Alavi-Moghaddam et al. Ultrasonography of inferior vena cava to determine central venous pressure: a meta-analysis and meta-regression. Acta radiologica (Stockholm, Sweden : 1987). 2017. PMID: 27557621. Registry ID: none in the record. MeSH: Central Venous Pressure/physiology* · Humans · Reproducibility of Results · Ultrasonography/methods* · Vena Cava, Inferior/diagnostic imaging*,physiopathology*

Card 2 — Emergency-department shock primary (Worapratya 2014, Open Access Emergency Medicine — prospective double-blind observational, 30 patients with shock and central catheters): caval index correlated with CVP at r = −0.721 (P = 0.000, two-dimensional) and r = −0.647 (P = 0.001, M-mode); caval-index cut-offs 30, 20 and 10 at CVP <10, 10–15 and >15 cm H₂O

Study: Prospective observational primary study

Population: 30 emergency-room patients presenting with shock who had a central venous catheter inserted; 17 (56.7%) were men. Caval index was calculated as the relative decrease in IVC diameter during the normal respiratory cycle.

Summary: Emergency-department shock primary (Worapratya 2014, Open Access Emergency Medicine — prospective double-blind observational, 30 patients with shock and central catheters): caval index correlated with CVP at r = −0.721 (P = 0.000, two-dimensional) and r = −0.647 (P = 0.001, M-mode); caval-index cut-offs 30, 20 and 10 at CVP <10, 10–15 and >15 cm H₂O

Result: The correlation of CVP with the ultrasound caval index was r = −0.721 (P = 0.000) by two-dimensional mode and r = −0.647 (P = 0.001) by M-mode. Correlations of CVP with end-expiratory IVC diameter were r = 0.551 (P = 0.002) two-dimensional and r = 0.492 (P = 0.008) M-mode. The caval-index cut-off points were 30, 20 and 10 at CVP levels <10, 10–15 and >15 cm H₂O respectively, as published.

Watch out: Thirty spontaneously breathing shock patients in one emergency department — the strongest single correlation in this pack comes from its smallest, narrowest sample, and its cut-offs are unvalidated outside it.

Source: Worapratya et al. Correlation of caval index, inferior vena cava diameter, and central venous pressure in shock patients in the emergency room. Open access emergency medicine : OAEM. 2014. PMID: 27147880. Registry ID: none in the record. MeSH: none in the record

Card 3 — Intubated ICU primary (Karacabey 2016, Pakistan Journal of Medical Sciences — 83 intubated critically ill patients, CVP by U-tube manometer): inspiratory IVC diameter correlated only weakly (r 0.1 as printed) while collapsibility correlated negatively with CVP (coefficient printed unsigned, r 0.68, P < 0.01)

Study: Primary observational study

Population: 83 intubated critically ill patients (mean age 73.6 ± 11.2 years; most common diagnosis sepsis, 21 patients, 25.30%); patients under 18, not intubated, with abdominal pressure >12 mmHg or admitted for trauma were excluded. CVP was measured with a U-tube manometer.

Summary: Intubated ICU primary (Karacabey 2016, Pakistan Journal of Medical Sciences — 83 intubated critically ill patients, CVP by U-tube manometer): inspiratory IVC diameter correlated only weakly (r 0.1 as printed) while collapsibility correlated negatively with CVP (coefficient printed unsigned, r 0.68, P < 0.01)

Result: IVC inspiration measurements were statistically significantly correlated with CVP (r: 0.1, as printed in the record). IVC collapsibility measurements showed a negative correlation with CVP (p < 0.01, r: 0.68 — the record states the direction in words and prints the coefficient unsigned; the sign convention is flagged here, not resolved). The authors describe a strong correlation between CVP and IVC diameters and the collapsibility index and propose a new formula for evaluating CVP from their analyses, as published.

Watch out: A ventilated population — the opposite breathing physiology from the shock primary — and the inspiratory-diameter correlation (r 0.1) is near zero even as the authors' conclusion claims strength; the record's own numbers, not its conclusion sentence, govern here.

Source: Karacabey et al. A Non-invasive Method for Assessment of Intravascular Fluid Status: Inferior Vena Cava Diameters and Collapsibility Index. Pakistan journal of medical sciences. 2016. PMID: 27648024. Registry ID: none in the record. MeSH: none in the record

Card 4 — Synthesis: IVC ultrasound correlates moderately with CVP at best (pooled r 0.44–0.68 by measurement) and the carded synthesis's own verdict is that it is not an acceptable surrogate — the correlation/surrogacy split is the finding; 1 synthesis (37 papers / 2,843 cases) + 2 small primaries (30 + 83 patients)

Study: Synthesis

Population: Populations never pooled: the synthesis's mixed critical-care pool; 30 spontaneously breathing emergency-department shock patients; 83 intubated critically ill patients. Total primary N carded here is 113, inside a 2,843-case synthesis pool.

Summary: Synthesis: IVC ultrasound correlates moderately with CVP at best (pooled r 0.44–0.68 by measurement) and the carded synthesis's own verdict is that it is not an acceptable surrogate — the correlation/surrogacy split is the finding; 1 synthesis (37 papers / 2,843 cases) + 2 small primaries (30 + 83 patients)

Result: Pooled correlations: diameter 0.68, inspiratory 0.60, collapsibility index 0.54, expiratory 0.44 — with the synthesis concluding IVC diameter measurement is not an acceptable surrogate for CVP. Primaries: caval index r = −0.721 / −0.647 (shock, n = 30) with cut-offs 30/20/10 across CVP bands; inspiratory r 0.1 and unsigned collapsibility r 0.68 (intubated, n = 83). No report was refused. The stamp is PREDICTIVE PERFORMANCE carrying the not-a-surrogate verdict at full weight.

Watch out: Never convert these correlations into a rule for reading a patient's CVP off an IVC image, and never quote the primaries' stronger coefficients without their tiny, unlike populations beside them.

Source: Synthesis of the reports carded above; no additional source.